Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Reduction of hexavalent chromium by fasted and fed human gastric fluid. II. Ex vivo gastric reduction modeling

To extend previous models of hexavalent chromium [Cr(VI)] reduction by gastric fluid (GF), ex vivo experiments were conducted to address data gaps and limitations identified with respect to (1) GF dilution in the model; (2) reduction of Cr(VI) in fed human GF samples; (3) the number of Cr(VI) reduction pools present in human GF under fed, fasted, and proton pump inhibitor (PPI)-use conditions; and (4) an appropriate form for the pH-dependence of Cr(VI) reduction rate constants. Rates and capacities of Cr(VI) reduction were characterized in gastric contents from fed and fasted volunteers, and from fasted pre-operative patients treated with PPIs. Reduction capacities were first estimated over a 4-h reduction period. Once reduction capacity was established, a dual-spike approach was used in speciated isotope dilution mass spectrometry analyses to characterize the concentration-dependence of the 2nd order reduction rate constants. These data, when combined with previously collected data, were well described by a three-pool model (pool 1 = fast reaction with low capacity; pool 2 = slow reaction with higher capacity; pool 3 = very slow reaction with higher capacity) using pH-dependent rate constants characterized by a piecewise, log-linear relationship. These data indicate that human gastric samples, like those collected from rats and mice, contain multiple pools of reducing agents, and low concentrations of Cr(VI) (< 0.7 mg/L) are reduced more rapidly than high concentrations. The data and revised modeling results herein provide improved characterization of Cr(VI) gastric reduction kinetics, critical for Cr(VI) pharmacokinetic modeling and human health risk assessment. - Highlights: • SIDMS allows for measurement of Cr(VI) reduction rate in gastric fluid ex vivo • Human gastric fluid has three reducing pools • Cr(VI) in drinking water at < 0.7 mg/L is rapidly reduced in human gastric fluid • Reduction rate is concentration- and pH-dependent • A refined PK model is used to characterize inter-individual variability in Cr(VI) gastric reduction capacity.

60 APPLIED LIFE SCIENCES↗

Sensor for Boundary Shear Stress in Fluid Flow

The formation of scour patterns at bridge piers is driven by the forces at the boundary of the water flow. In most experimental scour studies, indirect processes have been applied to estimate the shear stress using measured velocity profiles. The estimations are based on theoretical models and associated assumptions. However, the turbulence flow fields and boundary layer in the pier-scour region are very complex and lead to low-fidelity results. In addition, available turbulence models cannot account accurately for the bed roughness effect. Direct measurement of the boundary shear stress, normal stress, and their fluctuations are attractive alternatives. However, most direct-measurement shear sensors are bulky in size or not compatible to fluid flow. A sensor has been developed that consists of a floating plate with folded beam support and an optical grid on the back, combined with a high-resolution optical position probe. The folded beam support makes the floating plate more flexible in the sensing direction within a small footprint, while maintaining high stiffness in the other directions. The floating plate converts the shear force to displacement, and the optical probe detects the plate s position with nanometer resolution by sensing the pattern of the diffraction field of the grid through a glass window. This configuration makes the sensor compatible with liquid flow applications.

Bao, Xiaoqi↗

Measurement of Critical Adsorption of Nitrogen near Its Liquid-vapor Critical Point

The density profile of a critical fluid near a solid surface is expected to show an universal shape. This is known as critical adsorption. The measurement of this effect, especially close to the critical point, is often obscured by gravity. We were able to separate the gravitational effect from critical adsorption by using two capacitors, one with a large gap and one with a small gap of approximately 2 m. Within the uncertainty in the measurement, our data, which ranges between 10(exp -3) to 2 x 10(exp -6) in reduced temperatures, is consistent with the predicted power law dependence. This work is carried out in collaboration with Rafael Garcia, Sarah Scheidemantel and Klaus Knorr. It is funded by NASA's office of Biological and Physical Researchunder.

Chan, Moses↗

Pore size effects on the sorption of supercritical carbon dioxide in mesoporous CPG-10 silica

Excess sorption isotherms of supercritical carbon dioxide in mesoporous CPG-10 silica glasses with nominal pore sizes of 75 (7.5 nm) and 350 (35 nm) were measured gravimetrically at 35 C and 50 C and pressures of 0-200 bar. Formation of broad maxima in the excess sorption was observed at fluid densities below the bulk critical density. Positive values of excess sorption were measured at bulk densities below about 0.65-0.7 g/cm3, whereas zero and negative values were obtained at higher densities, indicating that the interfacial fluid becomes less dense than the corresponding bulk fluid at high fluid densities. A shift of the excess sorption peak position to higher fluid density is found with increasing pore width. The excess sorption of CO2 normalized to the specific surface area is higher for the 35 nm pore size material, suggesting pore confinement effects. Conversely, the pore volume normalized excess sorption is higher for the 7.5 nm pore size material. Assessment of mean pore density reveals regions of constant pore fluid density, located between the excess sorption peak and the adsorption/depletion transition. Both materials exhibit such regions of constant mean pore fluid density as a function of bulk CO2 density at the lower temperature of 35 C, but not at 50 C. The results of this study suggest that the CO2 storage capacity in quartz-rich reservoirs is higher for sites with low temperature and rock textures characterized by narrow pores with high surface to volume ratios.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highlights of the Zeno Results from the USMP-2 Mission

The Zeno instrument, a High-precision, light-scattering spectrometer, was built to measure the decay rates of density fluctuations in xenon near its liquid-vapor critical point in the low-gravity environment of the U.S. Space Shuttle. Eliminating the severe density gradients created in a critical fluid by Earth's gravity, we were able to make measurements to within 100 microKelvin of the critical point. The instrument flew for fourteen days in March, 1994 on the Space Shuttle Columbia, STS-62 flight, as part of the very successful USMP-2 payload. We describe the instrument and document its performance on orbit, showing that it comfortably reached the desired 3 microKelvin temperature control of the sample. Locating the critical temperature of the sample on orbit was a scientific challenge; we discuss the advantages and short-comings of the two techniques we used. Finally we discuss problems encountered with making measurements of the turbidity of the sample, and close with the results of the measurement of the decay rates of the critical-point fluctuations.

Gammon, Robert W.↗

Diffusivity Measured as a Function of Concentration

Optical diagnostic techniques have become an integral part of many measurements in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used to measure optical wave fronts for lens testing and combustion and fluid flow diagnostics. One such instrument is the point diffraction interferometer (PDI), which is considered to be robust because it has a common-path design. However, the PDI is difficult to align and has limited measurement range for liquid phase applications. Interferometry and schlieren techniques have been widely used for many years for gas flow visualization.

Rashidnia, Nasser↗

Tracking interface and common curve dynamics for two-fluid flow in porous media

Pore-scale studies of multiphase flow in porous medium systems can be used to understand transport mechanisms and quantitatively determine closure relations that better incorporate microscale physics into macroscale models. Multiphase flow simulators constructed using the lattice Boltzmann method provide a means to conduct such studies, including both the equilibrium and dynamic aspects. Moving, storing, and analyzing the large state space presents a computational challenge when highly-resolved models are applied. We present an approach to simulate multiphase flow processes in which in-situ analysis is applied to track multiphase flow dynamics at high temporal resolution. We compute a comprehensive set of measures of the phase distributions and the system dynamics, which can be used to aid fundamental understanding and inform closure relations for macroscale models. The measures computed include microscale point representations and macroscale averages of fluid saturations, the pressure and velocity of the fluid phases, interfacial areas, interfacial curvatures, interface and common curve velocities, interfacial orientation tensors, phase velocities and the contact angle between the fluid-fluid interface and the solid surface. Test cases are studied to validate the approach and illustrate how measures of system state can be obtained and used to inform macroscopic theory.

97 MATHEMATICS AND COMPUTING↗

Measurement of pressure gradients near the interface in the viscous fingering instability

The viscous fingering instability, which forms when a less-viscous fluid invades a more-viscous one within a confined geometry, is an iconic system for studying pattern formation. For both miscible and immiscible fluid pairs the growth dynamics change after the initial instability onset and the global structures, typical of late-time growth, are governed by the viscosity ratio. Here we introduce an experimental technique to measure flow throughout the inner and outer fluids. This probes the existence of a new length scale associated with the local pressure gradients around the interface and allows us to compare our results to the predictions of a previously proposed model for late-time finger growth. Published by the American Physical Society 2024

Physics↗

Experimental Combustion Dynamics Behavior of a Multi-Element Lean Direct Injection (LDI) Gas Turbine Combustor

An experimental investigation of the combustion dynamic characteristics of a research multi-element lean direct injection (LDI) combustor under simulated gas turbine conditions was conducted. The objective was to gain a better understanding of the physical phenomena inside a pressurized flametube combustion chamber under acoustically isolated conditions. A nine-point swirl venturi lean direct injection (SV-LDI) geometry was evaluated at inlet pressures up to 2,413 kPa and non-vitiated air temperatures up to 867 K. The equivalence ratio was varied to obtain adiabatic flame temperatures between 1388 K and 1905 K. Dynamic pressure measurements were taken upstream of the SV-LDI, in the combustion zone and downstream of the exit nozzle. The measurements showed that combustion dynamics were fairly small when the fuel was distributed uniformly and mostly due to fluid dynamics effects. Dynamic pressure fluctuations larger than 40 kPa at low frequencies were measured at 653 K inlet temperature and 1117 kPa inlet pressure when fuel was shifted and the pilot fuel injector equivalence ratio was increased to 0.72.

dynamics↗

Determination of high temperature strains using a PC based vision system

With the widespread availability of video digitizers and cheap personal computers, the use of computer vision as an experimental tool is becoming common place. These systems are being used to make a wide variety of measurements that range from simple surface characterization to velocity profiles. The Sub-Pixel Digital Image Correlation technique has been developed to measure full field displacement and gradients of the surface of an object subjected to a driving force. The technique has shown its utility by measuring the deformation and movement of objects that range from simple translation to fluid velocity profiles to crack tip deformation of solid rocket fuel. This technique has recently been improved and used to measure the surface displacement field of an object at high temperature. The development of a PC based Sub-Pixel Digital Image Correlation system has yielded an accurate and easy to use system for measuring surface displacements and gradients. Experiments have been performed to show the system is viable for measuring thermal strain.

Mcneill, Stephen R.↗

Measurement of Two-Phase Flow and Heat Transfer Parameters using Infrared Thermometry

A novel technique to measure heat transfer and liquid film thickness distributions over relatively large areas for two-phase flow and heat transfer phenomena using infrared (IR)thermometry is described. IR thermometry is an established technology that can be used to measure temperatures when optical access to the surface is available in the wavelengths of interest. In this work, a midwave IR camera (3.6-5.1 microns) is used to determine the temperature distribution within a multilayer consisting of a silicon substrate coated with a thin insulator. Since silicon is largely transparent to IR radiation, the temperature of the inner and outer walls of the multilayer can be measured by coating selected areas with a thin, IR opaque film. If the fluid used is also partially transparent to IR, the flow can be visualized and the liquid film thickness can be measured. The theoretical basis for the technique is given along with a description of the test apparatus and data reduction procedure. The technique is demonstrated by determining the heat transfer coefficient distributions produced by droplet evaporation and flow boiling heat transfer.

Kim, Tae-Hoon↗

Role of Fluid and Temperature in Fracture Mechanics and Coupled THMC Processes for Enhanced Geothermal Systems

The ability to sustain high energy extraction efficiency from Enhanced Geothermal Systems (EGS) is affected by the ability to measure, characterize, and predict the effect of different perturbations that arise from fluid injection rates, fluid temperature, and shut-in conditions on existing and stimulated fracture systems throughout a subsurface reservoir’s lifecycle. The difficulty arises from limited knowledge of the interaction of fluid and temperature driven fractures with frictional interfaces that govern local deformation and frictional behavior in the surrounding rock. Thermo-poro-mechanical coupled processes tend to dominate this interaction and strongly affect the permeability and local stress distributions that impact efficiency and prevent optimal stimulation conditions over multi-decadal time frames.

Pyrak-Nolte, Laura [Purdue Univ., West Lafayette, ↗

Sensors for Using Times of Flight to Measure Flow Velocities

Thin-film sensors for measuring flow velocities in terms of times of flight are undergoing development. These sensors are very small and can be mounted flush with surfaces of airfoils, ducts, and other objects along which one might need to measure flows. Alternatively or in addition, these sensors can be mounted on small struts protruding from such surfaces for acquiring velocity measurements at various distances from the surfaces for the purpose of obtaining boundary-layer flow-velocity profiles. These sensors are related to, but not the same as, hot-wire anemometers. Each sensor includes a thin-film, electrically conductive loop, along which an electric current is made to flow to heat the loop to a temperature above that of the surrounding fluid. Instantaneous voltage fluctuations in segments of the loop are measured by means of electrical taps placed at intervals along the loop. These voltage fluctuations are caused by local fluctuations in electrical resistance that are, in turn, caused by local temperature fluctuations that are, in turn, caused by fluctuations in flow-induced cooling and, hence, in flow velocity. The differential voltage as a function of time, measured at each pair of taps, is subjected to cross-correlation processing with the corresponding quantities measured at other pairs of taps at different locations on the loop. The cross-correlations yield the times taken by elements of fluid to travel between the pairs of taps. Then the component of velocity along the line between any two pairs of taps is calculated simply as the distance between the pairs of taps divided by the travel time. Unlike in the case of hot-wire anemometers, there is no need to obtain calibration data on voltage fluctuations versus velocity fluctuations because, at least in principle, the correlation times are independent of the calibration data.

Fralick, Gutave↗

Constant-temperature anemometry measurements in hypersonic boundary layers

One of the major unresolved issues in fluid dynamics is the nature of apparent stresses, called Reynolds stresses, which occur in turbulent boundary layers. In hypersonic boundary layers, the flow physics is further complicated by the large temperature and density fluctuations and the concomitant contamination of the Reynold stresses by fictitious terms. Because of the severe flow environment and the extraordinary demands on sensors and instruments, the turbulence characteristics of hypersonic boundary layers were studied in only a cursory fashion. The plans for supersonic (HSCT) and hypersonic (NASP) vehicles made supersonic flow physics one of the critical pacing technologies in aerospace science. In particular, experimental data are needed to verify candidate computer models and to reach an important understanding of the turbulence physics. The presented research is the start of a substantial effort to refine existing instrumentation and develop experimental techniques to measure the various component of the Reynolds stress in hypersonic boundary layers.

Spina, Eric F.↗

A Diethylene Glycol Condensation Particle Counter for Rapid Sizing of sub-3 nm Atmospheric Clusters

AbstractThis paper describes the modification of a laminar flow, thermally diffusive universal-fluid condensation particle counter (standard operation: 50% detection efficiency at 5 nm) to rapidly measure the size distribution of sub 3 nm aerosol. Sub 3 nm detection was achieved by using diethylene glycol as the working fluid, which enabled high instrument super-saturations while minimizing homogenous nucleation of the working fluid; a detection efficiency of 50% was achieved at 1.6 nm with laboratory-generated ammonium sulfate aerosol. Rapid aerosol sizing beneath 3 nm was achieved by inverting the measured grown droplet size distribution (1 second sampling) to recover the sampled aerosol size distribution. The developed inversion algorithm utilizes analytical kernel functions determined from the instrument response to pseudo-monodisperse ammonium sulfate aerosol from 1.5 nm to 20 nm, generated by a high resolution DMA and a nano DMA. The inversion algorithm was tested numerically with assumed, idealized aerosol size distributions consistent with observed new particle formation events, yielding reasonable agreement between inverted and assumed aerosol size distributions below 3 nm. Furthermore, this technique provides a measure of the aerosol size assuming an aerosol composition identical to that of the aerosol used to generate the experimentally determined kernel function.

54 ENVIRONMENTAL SCIENCES↗

Imaging and quantification of spreading and trapping of carbon dioxide in saline aquifers using meter-scale laboratory experiments

The role of capillary forces during buoyant migration of CO 2 is critical toward plume immobilization within the postinjection phase of a geological carbon sequestration operation. However, the inherent heterogeneity of the subsurface makes it very challenging to evaluate the effects of capillary forces on the storage capacity of these formations and to assess in situ plume evolution. To overcome the lack of accurate and continuous observations at the field scale and to mimic vertical migration and entrapment of realistic CO 2 plumes in the presence of a background hydraulic gradient, we conducted two unique long-term experiments in a 2.44 m × 0.5 m tank. X-ray attenuation allowed measuring the evolution of a CO 2 -surrogate fluid saturation, thus providing direct insight into capillarity-dominated and buoyancy-dominated flow processes occurring under successive drainage and imbibition conditions. The comparison of saturation distributions between two experimental campaigns suggests that layered-type heterogeneity plays an important role on nonwetting phase (NWP) migration and trapping, because it leads to (i) longer displacement times (3.6 months versus 24 days) to reach stable trapping conditions, (ii) limited vertical migration of the plume (with center of mass at 39% versus 55% of aquifer thickness), and (iii) immobilization of a larger fraction of injected NWP mass (67.2% versus 51.5% of injected volume) as compared to the homogenous scenario. Finally, while these observations confirm once more the role of geological heterogeneity in controlling buoyant flows in the subsurface, they also highlight the importance of characterizing it at scales that are below seismic resolution (1–10 m).

54 ENVIRONMENTAL SCIENCES↗

Overcoming the sensitivity vs. throughput tradeoff in Coulter counters: A novel side counter design

We report microfabricated Coulter counters are attractive for point of care (POC) applications since they are label free and compact. However, these approaches inherently suffer from a trade off between sample throughput and sensitivity. The counter measures a change in impedance due to displaced fluid volume by passing cells, and thus the counter's signal increases with the fraction of the sensing volume displaced. Reducing the size of the sensing region requires reductions in volumetric throughput in the absence of increased hydraulic pressure and sensor bandwidth. The risk of mechanical clog formation, rendering the counter inoperable, increases markedly with reductions in the size of the constriction aperture. We present here a microfluidic coplanar Coulter counter device design that overcomes the problem of constriction clogging while capable of operating in microfluidic channels filled entirely with highly conductive sample. The device utilizes microfabricated planar electrodes projecting into one side of the microfluidic channel and is easily integrated with upstream electronic, hydrodynamic, or other focusing units to produce efficient counting which could allow for dramatically increased volumetric and sample throughput. The design lends itself to simple, cost effective POC applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laboratory evaluation of cyclic underground hydrogen storage in the Temblor sandstone of the San Joaquin Basin, California

Underground Hydrogen Storage (UHS) in depleted oil and gas reservoirs could provide a cost-effective solution to balance seasonal fluctuations in renewable energy generation. However, data and knowledge on UHS at subsurface conditions are limited so it is difficult to estimate how effective this type of storage could be. In this study, we perform high pressure experiment to measure the effectiveness of cyclic hydrogen (H 2 ) storage in a specimen of Temblor sandstone retrieved from the San Joaquin Basin of California. Our experiment mimics reservoir pressure conditions to measure H 2 -brine relative permeability and fluid-rock interactions over the course of ten charging and discharging cycles. Initial gas breakthrough occurred at 15 % to 25 % H2 saturation in the specimen with 3 % NaCl brine as the resident fluid. Continuing injecting to 4 pore volumes (PV) of H 2 yielded an asymptotic H 2 saturation of 38 % to 41 %, a level often referred to as the irreducible gas saturation based on two-phase flow. The boundary condition in this study mimics the near wellbore region, which experiences bi-directional H 2 flow. This bi-directional flow led to evaporative drying of the specimen resulting in 94 % H 2 saturation at the end of 10th cycle. This indicates that cyclic flow and evaporative drying can lead to more efficient reservoir storage where a larger fraction of the reservoir porosity is usable to store H 2 . The produced gas stream consisted of H 2 mixed with 8 % to 22 % H 2 O, indicating formation dry-out by evaporation. Meanwhile, produced water chemistry indicated calcite and silicate dissolution, with calcite sourced from fossil fragments. This led to a loss of cementation and weakened the rock sample. Combined, our results indicate dry-out, compaction, increased H 2 saturation, rock weakening, and permeability loss during cyclic UHS. Overall, we anticipate that the combined effects should lead to higher than anticipated UHS storage efficiency per volume of sandstone reservoir rock.

08 HYDROGEN↗