Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gradient Limiters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Microstructural Characterization of Nb$_3$Sn Thin Films Using FIB Tomography

The accelerating gradient of N b3Sn superconducting radiofrequency (SRF) cavities is currently limited, and the underlying cause remains an open question in the field. One leading hypothesis attributes this limitation to the presence of tin-deficient regions within the N b3Sn coating, which can suppress the superheating field. Due to the relatively large coherence length of N b3Sn, defects near the surface may significantly interact with the RF field. However, these subsurface defects have proven difficult to characterize. This research aims to investigate the structure and distribution of subsurface Sn deficient regions to better understand their influence on cavity performance. We employ focused ion beam (FIB) tomography to analyze the subsurface microstructure of N b3Sn thin films. This technique enables threedimensional reconstruction of both the tin distribution and the grain structure within the film. By correlating Sn content with grain structure, we find that Sn deficient regions are more prevalent that previously thought. However, the Sn deficient regions are consistently located below the surface of the film where RF fields are strongly attenuated by supercurrent screening and are likely not a limiting factor for cavity performance

Viklund, Eric [Fermilab]↗

Toward continuum gyrokinetic study of high-field mirrors

High-temperature superconducting (HTS) magnetic mirrors under development exploit strong fields with high mirror ratio to compress loss cones and enhance confinement and may offer cheaper, more compact fusion power plant candidates. This new class of devices could exhibit largely unexplored interchange and gradient-driven modes. Such instabilities, and methods to stabilize them, can be studied with gyrokinetics, given the strong magnetization and prevalence of kinetic effects. Our focus here is to (a) determine if oft-used gyrokinetic models for open field lines produce the electron-confining (Pastukhov) electrostatic potential and (b) examine and address challenges faced by gyrokinetic codes in studying HTS mirrors. Here, we show that a one-dimensional limit of said models self-consistently develops a potential qualitatively approaching the analytical Pastukhov level. Additionally, we describe the computational challenges of studying high mirror ratios with open field line gyrokinetic solvers and offer a force softening method to mitigate small time steps needed for time integration in colossal magnetic field gradients produced by HTS coils, providing a 19X speedup.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Dimits Shift in More Realistic Gyrokinetic Plasma Turbulence Simulations

In simulations of turbulent plasma transport due to long wavelength, (k⊥pi ≤ 1), electrostatic drift-type instabilities we find that a nonlinear upshift of the effective threshold persists. This `Dimits shift' represents the difference between the linear threshold, at the onset of instability, and the nonlinear threshold, where transport increases suddenly as the driving temperature gradient is increased. As the drive increases, the magnitudes of turbulent eddies and zonal ows grow until the zonal flows become nonlinearly unstable to 'tertiary' modes and their sheared ows no longer grow fast enough to strongly limit eddy size. The tertiary mode threshold sets the effective nonlinear threshold for the heat transport, and the Dimits shift arises when this occurs at a zonal flow magnitude greater than that needed to limit transport near the linear threshold. Nextgeneration tokamaks will likely benefit from the higher effective threshold for turbulent transport, and transport models should incorporate suitable corrections to linear thresholds. These gyrokinetic simulations are more realistic than previous reports of a Dimits shift because they include nonadiabatic electron dynamics, strong collisional damping of zonal flows, and finite electron and ion collisionality together with realistic shaped magnetic geometry. Reversing previously reported results based on idealized adiabatic electrons, we find that increasing collisionality reduces the heat flux because collisionality reduces the nonadiabatic electron drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase-Field Modeling of Solute Precipitation and Dissolution

A phase-field approach to the dynamics of liquid-solid interfaces that evolve due to precipitation and/or dissolution is presented. For the purpose of illustration and comparison with other methods, phase field simulations were carried out assuming first order reaction (dissolution/precipitation) kinetics. In contrast to solidification processes controlled by a temperature field that is continuous across the solid/liquid interface (with a discontinuous temperature gradient) precipitation/dissolution is controlled by a solute concentration field that is discontinuous at the solid/liquid interface. The sharp-interface asymptotic analysis of the phase-field equations for solidification [Karma and Rappel, Phys. Rev. E57 (1998) 4342] has been modified for precipitation/dissolution processes to demonstrate that the phase-field equations converge to the proper sharp-interface limit. The mathematical model has been validated for a one-dimensional precipitation/dissolution problem by comparison with the analytical solution.

58 GEOSCIENCES↗

Resolve survey photometry and volume-limited calibration of the photometric gas fractions technique

We present custom-processed ultraviolet, optical, and near-infrared photometry for the REsolved Spectroscopy of a Local VolumE (RESOLVE) survey, a volume-limited census of stellar, gas, and dynamical mass within two subvolumes of the nearby universe (RESOLVE-A and RESOLVE-B). RESOLVE is complete down to baryonic mass ∼10{sup 9.1−9.3} M{sub ⊙}, probing the upper end of the dwarf galaxy regime. In contrast to standard pipeline photometry (e.g., SDSS), our photometry uses optimal background subtraction, avoids suppressing color gradients, and employs multiple flux extrapolation routines to estimate systematic errors. With these improvements, we measure brighter magnitudes, larger radii, bluer colors, and a real increase in scatter around the red sequence. Combining stellar mass estimates based on our optimized photometry with the nearly complete H i mass census for RESOLVE-A, we create new z = 0 volume-limited calibrations of the photometric gas fractions (PGF) technique, which predicts gas-to-stellar mass ratios (G/S) from galaxy colors and optional additional parameters. We analyze G/S-color residuals versus potential third parameters, finding that axial ratio is the best independent and physically meaningful third parameter. We define a “modified color” from planar fits to G/S as a function of both color and axial ratio. In the complete galaxy population, upper limits on G/S bias linear and planar fits. We therefore model the entire PGF probability density field, enabling iterative statistical modeling of upper limits and prediction of full G/S probability distributions for individual galaxies. These distributions have two-component structure in the red color regime. Finally, we use the RESOLVE-B 21 cm census to test several PGF calibrations, finding that most systematically under- or overestimate gas masses, but the full probability density method performs well.

79 ASTRONOMY AND ASTROPHYSICS↗

The North Atlantic circulation in the early 1980s - An estimate from inversion of a finite-difference model

A finite-difference model of the North Atlantic is constructed for the purpose of making an estimate of the circulation through an inverse calculation. The data base is eclectic, and includes hydrography, oxygen, nutrients, current meter and float records, atmospheric momentum, heat and water vapor transfers, as well as estimates of certain integral fluxes. Owing to the available hydrographic database, the model resolution is restricted to 1 deg at best, and is much coarser in many aspects. This limited resolution is a major obstacle to accurate estimates of climatological fluxes. In its final form, there are about 9000 constraints in 29,000 formal unknowns plus 9000 noise unknowns. The system is solved as a tapered least-squares system by a sparse conjugate gradient algorithm. With the exception of a few float velocities, all constraints are found to be consistent within error estimates. The model produces estimates of large-scale fluxes and flux divergences for all conventional properties including heat and nutrients as well as carbon dioxide and alkalinity. Meridional fluxes of carbon are found to be indistinguishable from zero, whereas the North Atlantic tends to export nutrients to the south, but carry heat to the north. Traditional oceanographic depictions of the circulation through combination of nonsynoptic data into steady models may have reached their useful limit in the present calculation, as the conflicts between the data and physical requirements become quantitatively apparent.

Martel, Francoise↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dosimetric quality, accuracy, and deliverability of modulated radiotherapy treatments for spinal metastases

Cancer often metastasizes to the vertebra, and such metastases can be treated successfully using simple, static posterior or opposed-pair radiation fields. However, in some cases, including when re-irradiation is required, spinal cord avoidance becomes necessary and more complex treatment plans must be used. This study evaluated 16 sample intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment plans designed to treat 6 typical vertebral and paraspinal volumes using a standard prescription, with the aim of investigating the advantages and limitations of these treatment techniques and providing recommendations for their optimal use in vertebral treatments. Treatment plan quality and beam complexity metrics were evaluated using the Treatment And Dose Assessor (TADA) code. A portal-imaging–based quality assurance (QA) system was used to evaluate treatment delivery accuracy, and radiochromic film measurements were used to provide high-resolution verification of treatment plan dose accuracy, especially in the steep dose gradient regions between each vertebral target and spinal cord. All treatment modalities delivered approximately the same doses and the same levels of dose heterogeneity to each planning target volume (PTV), although the minimum PTV doses in the vertebral plans were substantially lower than the prescription, because of the requirement that the plans meet a strict constraint on the dose to the spinal cord and cord planning risk volume (PRV). All plans met required dose constraints on all organs at risk, and all measured PTV-cord dose gradients were steeper than planned. Beam complexity analysis suggested that the IMRT treatment plans were more deliverable (less complex, leading to greater QA success) than the VMAT treatment plans, although the IMRT plans also took more time to deliver. The accuracy and deliverability of VMAT treatment plans were found to be substantially increased by limiting the number of monitor units (MU) per beam at the optimization stage, and thereby limiting beam modulation complexity. The VMAT arcs that were optimized with MU limitation had higher QA pass rates as well as higher modulation complexity scores (less complexity), lower modulation indices (less modulation), lower MU per beam, larger beam segments, and fewer small apertures than the VMAT arcs that were optimized without MU limitation. It is recommended that VMAT treatments for vertebral volumes, where the PTV abuts or surrounds the spinal cord, should be optimized with MU limitation. IMRT treatments may be preferable to the VMAT treatments, for dosimetry and deliverability reasons, but may be inappropriate for some patients because of their increased treatment delivery time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optical metrology for testing an all-composite 2-meter diameter mirror

The Herschel Space Observatory (formerly known as FIRST) consists of a 3.5 m space telescope designed for use in the long IR and sub-milimeter wavebands. To demonstrate the viability of a carbon fiber composite telescope for this application, Composite Optics Incorporated (COI) manufactured a fast (f/1), large (2 m), lightweight (10.1 kg/m squared) demonstration mirror. A key challenge in demonstrating the performance of this novel mirror was to characterize the surface accuracy at cryogenic (70 K) temperatures. A wide variety of optical metrology techniques were investigated and a brief survey of empirical test results and limitations of the various techniques will be presented in this paper. Two complementary infrared (IR)techniques operating at a wavelength of 10.6 microns were chosen for further development: (1) IR Twyman-Green Phase Shifting Interferometry (IR PSI) and (2) IR Shack-Hartmann (IR SH) Wavefront Sensing. Innovative design modifications made to an existing IR PSI to achieve high-resolution, scannable, infrared measurements of the composite mirror are described. The modified interferometer was capable of measuring surface gradients larger than 350 microradians. The design and results of measurements made with a custom-built IR SH Wavefrong Sensor operating at 10.6 microns are also presented. A compact experimental setup permitting simultaneous operation of both the IR PSI and IR SH tools is shown. The advantages and the limitations of the two key IR metrology tools are discussed.

IR metrology phase shifting interferometry Shack-H↗

Charge fingerprint in relation to mineralogical composition of Quaternary volcanic ash along a climatic gradient on Java Island, Indonesia

We studied the relationship between the mineralogical composition and surface charge properties of representative Quaternary volcanic ash soils, classified as Andosols, along an East-West sequence on Java Island in Indonesia. Most of the studied soils have a limited ability to retain cations under their forest or grass vegetation. The surface charge properties of these soils are mainly controlled by the relative amounts of nanocrystalline minerals, mainly allophane and to a lesser extent ferrihydrite, in addition to organic matter (especially Al- and Fe-humus complexes), crystalline Fe oxides, gibbsite, and layer silicates (e.g., halloysite, smectite, kaolinite). Based on the composition of their clay fraction, the studied soils can be grouped in two categories: (i) allophane-poor Andosols of East Java, which contain a considerable amount of either halloysite or a mixture of 2:1 and 1:1 layer silicates; and (ii) allophane-rich Andosols dominated either by kaolinitic clays, gibbsitic material or a mixture of 1:1 and 2:1 layer silicate clays, which are more prominent in West and also occur in Central Java. Differences between both groups are attributed mainly to more pronounced seasonality in East Java, with variations in parent ash composition, becoming more acidic from east to west, as subordinate factor. The more severely leaching environment in West Java results in a higher degree of desilication , which led to a higher point of zero net charge (PZNC) and pHo in the allophane-rich soils. The soils belonging to this group exhibit extreme variable charge characteristics, and a net ‘positive’ variable surface charge at soil pH.

Utami, S. R.↗

Diffusiophoresis in one-dimensional solute gradients

Here, the diffusiophoretic motion of suspended colloidal particles under one-dimensional solute gradients is solved using numerical and analytical techniques. Similarity solutions are developed for the injection and withdrawal dynamics of particles into semi-infinite pores. Furthermore, a method of characteristics formulation of the diffusion-free particle transport model is presented and integrated to realize particle trajectories. Analytical solutions are presented for the limit of small particle diffusiophoretic mobility Γ p relative to the solute diffusivity D s for particle motions in both semi-infinite and finite domains. Results confirm the build up of local maxima and minima in the propagating particle front dynamics. The method of characteristics is shown to successfully predict particle motions and the position of the particle front, although it fails to accurately predict suspended particle concentrations in the vicinity of sharp gradients, such as at the particle front peak seen in some injection cases, where particle diffusion inevitably plays an important role. Results inform the design of applications in which the use of applied solute gradients can greatly enhance particle injection into and withdrawal from pores.

36 MATERIALS SCIENCE↗

Soret Effect Study on High-Pressure CO 2 -Water Solutions Using UV-Raman Spectroscopy and a Concentric-Tube Optical Cell

Spatially resolved deep-UV Raman spectroscopy was applied to solutions of CO 2 and H 2 O (or D 2 O), which were subject to a temperature gradient in a thermally regulated high-pressure concentric-tube Raman cell in an attempt to measure a Soret effect in the vicinity of the critical point of CO 2 . Although Raman spectra of solutions of CO 2 dissolved in D 2 O at 10 MPa and temperatures near the critical point of CO 2 had adequate signal-to-noise and spatial resolution to observe a Soret effect with a Soret coefficient with magnitude of |S T | > 0.03, no evidence for an effect of this size was obtained for applied temperature gradients up to 19⁰C. The presence of 1 M NaCl did not make a difference. In contrast, the concentration of CO 2 dissolved in H 2 O was shown to vary significantly across the temperature gradient when excess CO 2 was present, but the results could be explained simply by the variation in CO 2 solubility over the temperature range and not to kinetic factors. For mixtures of D 2 O dissolved in scCO 2 at 10 MPa and temperatures close to the critical point of CO 2 , the Raman peaks for H 2 O were too weak to measure with confidence even at the limit of D 2 O solubility.

99 GENERAL AND MISCELLANEOUS↗

Towards catchment classification in data-scarce regions

Assessing spatial variation in hydrologic processes can help to inform freshwater management and advance ecological understanding, yet many areas lack sufficient flow records on which to base classifications. Seeking to address this challenge, we apply concepts developed in data-rich settings to public, global data in order to demonstrate a broadly replicable approach to characterizing hydrologic variation. The proposed approach groups the basins associated with reaches in a river network according to key environmental drivers of hydrologic conditions. This initial study examines Colorado (USA), where long-term streamflow records permit comparison to previously distinguished flow regime types, and the Republic of Ecuador, where data limitations preclude such analysis. The flow regime types assigned to gages in Colorado corresponded reasonably well to the classes distinguished from environmental features. The divisions in Ecuador reflected major known biophysical gradients while also providing a higher resolution supplement to an existing depiction of freshwater ecoregions. Although freshwater policy and management decisions occur amidst uncertainty and imperfect knowledge, this classification framework offers a rigorous and transferrable means to distinguish catchments in data-scarce regions. The maps and attributes of the resulting ecohydrologic classes offer a departure point for additional study and data collection programs such as the placement of stations in under-monitored classes, and the divisions may serve as a preliminary template with which to structure conservation efforts such as environmental flow assessments.

13 HYDRO ENERGY↗

Proteomic profiling of human plasma exosomes identifies PPAR{gamma} as an exosome-associated protein

Exosomes are nanovesicles that are released from cells as a mechanism of cell-free intercellular communication. Only a limited number of proteins have been identified from the plasma exosome proteome. Here, we developed a multi-step fractionation scheme incorporating gel exclusion chromatography, rate zonal centrifugation through continuous sucrose gradients, and high-speed centrifugation to purify exosomes from human plasma. Exosome-associated proteins were separated by SDS-PAGE and 66 proteins were identified by LC-MS/MS, which included both cellular and extracellular proteins. Furthermore, we identified and characterized peroxisome proliferator-activated receptor-{gamma} (PPAR{gamma}), a nuclear receptor that regulates adipocyte differentiation and proliferation, as well as immune and inflammatory cell functions, as a novel component of plasma-derived exosomes. Given the important role of exosomes as intercellular messengers, the discovery of PPAR{gamma} as a component of human plasma exosomes identifies a potential new pathway for the paracrine transfer of nuclear receptors.

60 APPLIED LIFE SCIENCES↗

Finite-volume scheme for anisotropic diffusion

In this paper, we apply a special finite-volume scheme, limited to smooth temperature distributions and Cartesian grids, to test the importance of connectivity of the finite volumes. The area of application is nuclear fusion plasma with field line aligned temperature gradients and extreme anisotropy. We apply the scheme to the anisotropic heat-conduction equation, and compare its results with those of existing finite-volume schemes for anisotropic diffusion. Also, we introduce a general model adaptation of the steady diffusion equation for extremely anisotropic diffusion problems with closed field lines.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dosimetric Verification of Intensity Modulated Radiation Therapy of 172 Patients Treated for Various Disease Sites: Comparison of EBT Film Dosimetry, Ion Chamber Measurements, and Independent MU Calculations

Three independent dose verification methods for intensity modulated radiation therapy (IMRT) were evaluated. Planar IMRT dose distributions were delivered to EBT film and scanned with the Epson Expression 1680 flatbed scanner. The measured dose distributions were then compared to those calculated with a Pinnacle treatment planning system. The IMRT treatments consisted of 7 to 9 6-MV beams for different treatment sites. The films were analyzed using FilmQA (3cognition LLC, Great Neck, NY) software. Comparisons between measured and calculated dose distributions are reported as dose difference (DD) (pixels within {+-} 5%), distance to agreement (DTA) (3 mm), as well as gamma values ({gamma}) (dose = {+-} 3%, distance = 2 mm). Point dose measurements with an ion chamber at isocenter were compared to dose calculated at that point. An independent monitor units (MUs) calculation program was also used for verification. For the film dose distributions, DD values varied from 92% to 97%, with head-and-neck and lung treatments showing lower values. Gamma varied from 93% to 98%, and DTA was well above 99%. The isocenter dose measurements deviated from 0.008 to 0.028 from the calculated dose. The larger deviations were attributed to high-dose gradients at the isocenter. RadCalc MU calculations gave differences from 0.027 to 0.079. The larger differences observed were for beams crossing large areas of heterogeneous tissue and were attributed to the limitations of the simple path-length correction method employed in RadCalc. In conclusion, the 3 independent verification methods for each IMRT patient at our institution demonstrated very good agreement between measurements and calculations and gave us the confidence that our IMRT treatments are delivered accurately.

61 RADIATION PROTECTION AND DOSIMETRY↗

Exchange of Ions across the TiN/TaO x Interface during Electroformation of TaO x -Based Resistive Switching Devices

The valence change model describes the resistive switching in metal oxide-based devices as due to electroreduction of the oxide and subsequent electromigration of oxygen vacancies. Here, we present cross-sectional X-ray energy-dispersive spectroscopy elemental maps of Ta, O, N, and Ti in electroformed TiN/TaO 2.0 /TiN structures. O, N, and Ti were exchanged between the anode and the functional oxide in devices formed at high power (~1 mW), but the exchange was below the detection limit at low power (<0.5 mW). All structures exhibit a similar Ta-enriched and O-depleted filament formed by the elemental segregation in the functional oxide by the temperature gradient. The elemental interchange is interpreted as due to Fick’s diffusion caused by high temperatures in the gap of the filament and is not an essential part of electroformation.

36 MATERIALS SCIENCE↗

Evaporated CdSe for Efficient Polycrystalline CdSeTe Thin-Film Solar Cells

Recent progress has shown that alloying cadmium telluride (CdTe) with cadmium selenide (CdSe) to create a CdSexTe1-x (CdSeTe) gradient region can significantly boost the performance of polycrystalline CdSeTe thin-film solar cells. However, improper CdSeTe alloying might introduce problematic band alignment and deleterious voids at the front interface, limiting the benefit maximization of this technique. Here, we show that the CdSe layers deposited by thermal evaporation result in CdSeTe cells with a higher performance than the sputtered CdSe. This is because evaporated CdSe can avoid the formation of voids at the front interface, producing improved front junction quality with suppressed front junction nonradiative recombination. The champion cell using evaporated CdSe demonstrated a power conversion efficiency (PCE) of 19.7%, much higher than 18.1% in the cell using sputtered CdSe.

cadmium selenide↗