Buckling and failure characteristics of graphite-polyimide shear panels
The buckling and failure characteristics of unstiffened, blade stiffened, and hat stiffened graphite-polyimide shear panels are described. The picture frame shear test is used to obtain shear stress-strain data at room temperature and at 316 deg C. The experimental results are compared with a linear buckling analysis, and the specimen failure modes are described. The effect of the 316 deg C test temperature on panel behavior are discussed.