Search NASA⌕ Search

SEARCH · Search NASA

Results for “High spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Nanometre-resolved observation of electrochemical microenvironment formation at the nanoparticle–ligand interface

The dynamic response of surface ligands on nanoparticles (NPs) to external stimuli critically determines the functionality of NP–ligand systems. For example, in electrocatalysis the collective dissociation of ligands on NP surfaces can lead to the creation of an NP/ordered-ligand interlayer, a microenvironment that is highly active and selective for CO 2 -to-CO conversion. However, the lack of in situ characterization techniques with high spatial resolution hampers a comprehensive molecular-level understanding of the mechanism of interlayer formation. Here, in this work, we utilize in situ infrared nanospectroscopy and surface-enhanced Raman spectroscopy, unveiling an electrochemical bias-induced consecutive bond cleavage mechanism of surface ligands leading to formation of the NP/ordered-ligand interlayer. This real-time molecular insight could influence the design of confined localized fields in multiple catalytic systems. Moreover, the demonstrated capability of capturing nanometre-resolved, dynamic molecular-scale events holds promise for the advancement of using controlled local molecular behaviour to achieve desired functionalities across multiple research domains in nanoscience.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A compendium of multi-omic sequence information from the Saanich Inlet water column

Marine oxygen minimum zones (OMZs) are widespread regions of the ocean that are currently expanding due to global warming. While inhospitable to most metazoans, OMZs are hotspots for microbial mediated biogeochemical cycling of carbon, nitrogen and sulphur, contributing disproportionately to marine nitrogen loss and climate active trace gas production. Our current understanding of microbial community responses to OMZ expansion is limited by a lack of time-resolved data sets linking multi-omic sequence information (DNA, RNA, protein) to geochemical parameters and process rates. Here, we present six years of time-resolved multi-omic observations in Saanich Inlet, a seasonally anoxic fjord on the coast of Vancouver Island, British Columbia, Canada that undergoes recurring changes in water column oxygenation status. This compendium provides a unique multi-omic framework for studying microbial community responses to ocean deoxygenation along defined geochemical gradients in OMZ waters.

Hawley, Alyse K. (ORCID:0000000235164043)↗

Unsupervised data mining in nanoscale x-ray spectro-microscopic study of NdFeB magnet

Novel developments in X-ray based spectro-microscopic characterization techniques have increased the rate of acquisition of spatially resolved spectroscopic data by several orders of magnitude over what was possible a few years ago. This accelerated data acquisition, with high spatial resolution at nanoscale and sensitivity to subtle differences in chemistry and atomic structure, provides a unique opportunity to investigate hierarchically complex and structurally heterogeneous systems found in functional devices and materials systems. However, handling and analyzing the large volume data generated poses significant challenges. Here we apply an unsupervised data-mining algorithm known as DBSCAN to study a rare-earth element based permanent magnet material, Nd 2 Fe 14 B. We are able to reduce a large spectro-microscopic dataset of over 300,000 spectra to 3, preserving much of the underlying information. Scientists can easily and quickly analyze in detail three characteristic spectra. Our approach can rapidly provide a concise representation of a large and complex dataset to materials scientists and chemists. For instance, it shows that the surface of common Nd 2 Fe 14 B magnet is chemically and structurally very different from the bulk, suggesting a possible surface alteration effect possibly due to the corrosion, which could affect the material’s overall properties.

36 MATERIALS SCIENCE↗

Diffusion in biofilms respiring on electrodes

The goal of this study was to measure spatially and temporally resolved effective diffusion coefficients (De) in biofilms respiring on electrodes. Two model electrochemically active biofilms, Geobacter sulfurreducens PCA and Shewanella oneidensis MR-1, were investigated. A novel nuclear magnetic resonance microimaging perfusion probe capable of simultaneous electrochemical and pulsed-field gradient nuclear magnetic resonance (PFG-NMR) techniques was used. PFG-NMR allowed for noninvasive, nondestructive, high spatial resolution in situ De measurements in living biofilms respiring on electrodes. The electrodes were polarized so that they would act as the sole terminal electron acceptor for microbial metabolism. We present our results as both two-dimensional De heat maps and surface-averaged relative effective diffusion coefficient (Drs) depth profiles. We found that (1) Drs decreases with depth in G. sulfurreducens biofilms, following a sigmoid shape; (2) Drs at a given location decreases with G. sulfurreducens biofilm age; (3) average De and Drs profiles in G. sulfurreducens biofilms are lower than those in S. oneidensis biofilms—the G. sulfurreducens biofilms studied here were on average 10 times denser than the S. oneidensis biofilms; and (4) halting the respiration of a G. sulfurreducens biofilm decreases the De values. Density, reflected by De, plays a major role in the extracellular electron transfer strategies of electrochemically active biofilms.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of extreme ultraviolet laser ablation mass spectrometry for actinide trace analysis and nanoscale isotopic imaging

The purpose of this research was to characterize Extreme Ultraviolet Time-of-Flight (EUV TOF) Laser Ablation Mass Spectrometry for high spatial resolution elemental and isotopic analysis. We compare EUV TOF results with Secondary Ionization Mass Spectrometry (SIMS) to orient the EUV TOF method within the overall field of analytical mass spectrometry. Using the well-characterized NIST 61x glasses, we show that the EUV ionization approach produces relatively few molecular ion interferences in comparison to TOF SIMS. We demonstrate that the ratio of element ion to element oxide ion is adjustable with EUV laser pulse energy and that the EUV TOF instrument has a sample utilization efficiency of 0.014%. The EUV TOF system also achieves a lateral resolution of 80 nm and we demonstrate this lateral resolution with isotopic imaging of closely spaced particles or uranium isotopic standard materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous electrical recording of cardiac electrophysiology and contraction on chip

Prevailing commercialized cardiac platforms for in vitro drug development utilize planar microelectrode arrays to map action potentials, or impedance sensing to record contraction in real time, but cannot record both functions on the same chip with high spatial resolution. We report a novel cardiac platform that can record cardiac tissue adhesion, electrophysiology, and contractility on the same chip. The platform integrates two independent yet interpenetrating sensor arrays: a microelectrode array for field potential readouts and an interdigitated electrode array for impedance readouts. Together, these arrays provide real-time, non-invasive data acquisition of both cardiac electrophysiology and contractility under physiological conditions and under drug stimuli. Furthermore, we cultured human induced pluripotent stem cell-derived cardiomyocytes as a model system, and used to validate the platform with an excitation–contraction decoupling chemical. Preliminary data using the platform to investigate the effect of the drug norepinephrine are combined with computational efforts. Finally, this platform provides a quantitative and predictive assay system that can potentially be used for comprehensive assessment of cardiac toxicity earlier in the drug discovery process.

59 BASIC BIOLOGICAL SCIENCES↗

The GAPS programme at TNG

Neptunes represent one of the main types of exoplanets and have chemical-physical characteristics halfway between rocky and gas giant planets. Therefore, their characterization is important for understanding and constraining both the formation mechanisms and the evolution patterns of planets. We investigate the exoplanet candidate TOI-1422 b, which was discovered by the TESS space telescope around the high proper-motion G2 V star TOI-1422 (V = 10.6 mag), 155 pc away, with the primary goal of confirming its planetary nature and characterising its properties. We monitored TOI-1422 with the HARPS-N spectrograph for 1.5 yr to precisely quantify its radial velocity (RV) variation. We analyse these RV measurements jointly with TESS photometry and check for blended companions through high-spatial resolution images using the AstraLux instrument. We estimate that the parent star has a radius of R$_\star$ = 1.019 -0.013 +0.014 R ⊙ , and a mass of M$_\star$ = 1.019 -0.013 +0.014 M ⊙ . Our analysis confirms the planetary nature of TOI-1422 b and also suggests the presence of a Neptune-mass planet on a more distant orbit, the candidate TOI-1422 c, which is not detected in TESS light curves. The inner planet, TOI-1422 b, orbits on a period of P b = 12.9972 ± 0.0006 days and has an equilibrium temperature of T eq,b = 867 ± 17 K. With a radius of R b = 3.96 -0.11 +0.13 R ⊕ , a mass of M b = 9.0 -2.0 +2.3 M ⊕ and, consequently, a density of ρ b = 0.795 -0.235 +0.290 g cm -3 , it can be considered a warm Neptune-sized planet. Compared to other exoplanets of a similar mass range, TOI-1422 b is among the most inflated, and we expect this planet to have an extensive gaseous envelope that surrounds a core with a mass fraction around 10% – 25% of the total mass of the planet. The outer non-transiting planet candidate, TOI-1422 c, has an orbital period of P c = 29.29 -0.20 +0.21 days, a minimum mass, M c sin i, of 11.1 -2.3 +2.6 M ⊕ , an equilibrium temperature of T eq,c = 661 ± 13 K and, therefore, if confirmed, could be considered as another warm Neptune.

79 ASTRONOMY AND ASTROPHYSICS↗

MUSE adaptive-optics spectroscopy confirms dual active galactic nuclei and strongly lensed systems at sub-arcsec separation

The novel Gaia multi peak (GMP) technique has proven to be able to successfully select dual and lensed active galactic nuclei (AGN) candidates at sub-arcsecond separations. Both populations are important because dual AGN represent one of the central, still largely untested, predictions of ΛCDM cosmology, and compact lensed AGN allow us to probe the central regions of the lensing galaxies. In this work, we present high-spatial-resolution spectroscopy of 12 GMP-selected systems. We used the adaptive-optics assisted integral-field spectrograph MUSE at the VLT to resolve each system and investigate the nature of each component. All targets show the presence of two components confirming the GMP selection. We classify 4 targets as dual AGN, 3 as lensed quasar candidates, and 5 as a chance alignment of a star and an AGN. With separations ranging from 0.30″ to 0.86″, these dual and lensed systems are among the most compact systems discovered to date at z > 0.5. This is the largest sample of distant dual AGN with sub-arcsecond separations ever presented in a single paper.

Scialpi, M. (ORCID:0009000651004986)↗

Use of imaging plates at near saturation for high energy density particles

Since an imaging plate (IP) is sensitive to electron, ion, and x rays, it can be used as a detector for laser plasma experiment using ultraintense laser. Moreover, an IP has the advantageous features such as high sensitivity, wide dynamic range, and high spatial resolution. Even though IP itself has a considerable wide dynamic range up to 10{sup 5}, the IP data have appeared often saturated at an IP reading device. We propose a reading technique by inserting optical density filters so that an apparently saturated IP data can be saved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photothermal excitation and laser Doppler velocimetry of higher cantilever vibration modes for dynamic atomic force microscopy in liquid

The authors present an optically based method combining photothermal excitation and laser Doppler velocimetry of higher cantilever vibration modes for dynamic atomic force microscopy in liquid. The frequency spectrum of a silicon cantilever measured in water over frequencies ranging up to 10 MHz shows that the method allows us to excite and detect higher modes, from fundamental to fifth flexural, without enhancing spurious resonances. By reducing the tip oscillation amplitude using higher modes, the average tip-sample force gradient due to chemical bonds is effectively increased to achieve high-spatial-resolution imaging in liquid. The method's performance is demonstrated by atomic resolution imaging of a mica surface in water obtained using the second flexural mode with a small tip amplitude of 99 pm; individual atoms on the surface with small height differences of up to 60 pm are clearly resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluorescent X-Ray Computed Tomography towards Molecular Imaging: Proof-of-Concept Experiments

By means of fluorescent x-ray computed tomography (FXCT) one can detect and image a distribution of non-radioactive imaging agent, e.g., iodine, in a biomedical subject at a high spatial resolution, so it can be a novel molecular imaging modality. We have been studying an FXCT system using synchrotron radiation for in-vivo imaging brains of small animals such as mouse, or rat. For the purpose, we propose a fast FXCT imaging method based on the novel geometry. In this study, we prove the feasibility of this concept and investigate its imaging properties, including spatial and contrast resolutions and quantitativeness, by imaging an acrylic phantom and a normal mouse brain using a preliminary imaging system with monochromatic synchrotron x rays.

60 APPLIED LIFE SCIENCES↗

Quantitative compositional analysis and strain study of InAs quantum wires with InGaAlAs barrier layers

Quantitative compositional analysis of InAs quantum wires deposited between In{sub 0.53}Ga{sub 0.37}Al{sub 0.1}As barrier layers grown on InP substrates was performed by electron energy loss spectrometry and energy dispersive x-ray spectrometry. An indium-rich region in the center of the wire, with decreasing indium concentration toward the interface with the barrier layers, was observed from indium concentration maps for individual quantum wires. 'Stripelike' contrast modulation was observed in diffraction contrast transmission electron microscope images of the In{sub 0.53}Ga{sub 0.37}Al{sub 0.1}As barrier layer immediately above the quantum wires. The contrast originated from indium compositional modulations in the upper barrier layer as confirmed by electron energy loss spectrometry and the modulation is attributed to the presence of an inhomogeneous elastic strain field generated by the buried quantum wires. These results suggest that quantitative analysis of the composition and strain distributions at very high spatial resolution provides insights necessary to further model the physical properties and to understand the growth of these nanostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Hard x-ray response of pixellated CdZnTe detectors

In recent years, the development of cadmium zinc telluride (CdZnTe) detectors for x-ray and gamma ray spectrometry has grown rapidly. The good room temperature performance and the high spatial resolution of pixellated CdZnTe detectors make them very attractive in space-borne x-ray astronomy, mainly as focal plane detectors for the new generation of hard x-ray focusing telescopes. In this work, we investigated on the spectroscopic performance of two pixellated CdZnTe detectors coupled with a custom low noise and low power readout application specific integrated circuit (ASIC). The detectors (10x10x1 and 10x10x2 mm{sup 3} single crystals) have an anode layout based on an array of 256 pixels with a geometric pitch of 0.5 mm. The ASIC, fabricated in 0.8 mum BiCMOS technology, is equipped with eight independent channels (preamplifier and shaper) and characterized by low power consumption (0.5 mW/channel) and low noise (150-500 electrons rms). The spectroscopic results point out the good energy resolution of both detectors at room temperature [5.8% full width at half maximum (FWHM) at 59.5 keV for the 1 mm thick detector; 5.5% FWHM at 59.5 keV for the 2 mm thick detector) and low tailing in the measured spectra, confirming the single charge carrier sensing properties of the CdZnTe detectors equipped with a pixellated anode layout. Temperature measurements show optimum performance of the system (detector and electronics) at T=10 deg.C and performance degradation at lower temperatures. The detectors and the ASIC were developed by our collaboration as two small focal plane detector prototypes for hard x-ray multilayer telescopes operating in the 20-70 keV energy range.

36 MATERIALS SCIENCE↗

Polymer/carbon nanotube composite patterns via laser induced forward transfer

Direct and high spatial resolution printing of polymer/carbon nanotube (CNT) composite layers has been demonstrated by means of laser induced forward transfer (LIFT). Laser irradiation of composite target materials, such as poly(acrylic acid)/CNT and polyvinylpyrrolidone/CNT, enabled dry deposition of well resolved composite pixels onto glass substrates. The dispersion of the CNT into the deposited composite pixels was investigated by transmission electron microscopy. The LIFT technique was also employed for the accurate deposition of polymer/CNT composite pixels onto aluminum microelectrodes for the fabrication of chemical sensors based on polymer/CNT compounds.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Multifrequency continuous wave terahertz spectroscopy for absolute thickness determination

We present a tunable multifrequency continuous wave terahertz spectrometer based on two laser diodes, photoconductive antennas, and a coherent detection scheme. The system is employed to determine the absolute thickness of samples utilizing a proposed synthetic difference frequency method to circumvent the 2pi uncertainty known from conventional photomixing systems while preserving a high spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simple hard x-ray ''nanoslit'' for measuring wavefront intensity

A new method is proposed for nanoscale hard x-ray measurements. This method uses a reflection on a heavy-metal wire that functions as a single slit with a nanoscale aperture for a parallel x-ray beam. This ''nanoslit'' can be used to perform high-spatial-resolution measurements of the intensity distribution of a wavefront that diverges from an aperture. In experiments, Fresnel fringes generated by a rectangular aperture were measured using a 300-{mu}m-diameter platinum wire as the nanoslit. In these experiments, the finest fringes with a period of 26 nm could be successfully resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of X-ray Beam Position Monitors for Superconducting Wiggler

For the development of an X-ray beam position monitor (XBPM) for the superconducting wiggler (SW) at the NSRRC, two XBPM are installed in the SW front end. The blades of the XBPM were manufactured with material of three types; tungsten, Glidcop and aluminium, to test the effect of the material on the performance of the XBPM. These three materials are compared with blades of molybdenum that were previously installed. The vibration and thermal expansion of the pillar of a XBPM affects the position reading of the XBPM. For pillars of XBPM of various designs, each type has a distinct thermal isolating material and is filled with a separate damping material for comparison. The design requirements of these XBPM include high spatial resolution of the monitor and mechanical stability of the structure with a large thermal load. The design, fabrication and measurement results are presented here.

43 PARTICLE ACCELERATORS↗