Search NASA⌕ Search

SEARCH · Search NASA

Results for “Impact loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Case Study: Hybridizing Nuclear Energy Systems in the U.S.

This case study was presented at the ICTP-IAEA VIRTUAL Course on Nuclear-Renewable Integrated Energy Systems: Phenomenology, Research and Development. It provides preliminary results on an analysis of hybridizing the two nuclear power plants owned by Xcel Energy and located in Minnesota. The analysis extends previous analyses that provided only price-taker results. Those assume adjusting the generation sold to the grid does not impact locational marginal electricity prices nor do they estimate impacts on the total net cost to serve the load. This presentation summarizes the new technique that was developed to both optimize the size and operations of the hybridized system and the resulting impacts on the grid when it is operated optimally.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Powerloads on the front end components and the duct of the heating and diagnostic neutral beam lines at ITER

The heating and current drive beam lines (HNB) at ITER are expected to deliver ∼16.7 MW power per beam line for H beams at 870 keV and D beams at 1 MeV during the H-He and the DD/DT phases of ITER operation respectively. On the other hand the diagnostic neutral beam (DNB) line shall deliver ∼2 MW power for H beams at 100 keV during both the phases. The path lengths over which the beams from the HNB and DNB beam lines need to be transported are 25.6 m and 20.7 m respectively. The transport of the beams over these path lengths results in beam losses, mainly by the direct interception of the beam with the beam line components and reionisation. The lost power is deposited on the surfaces of the various components of the beam line. In order to ensure the survival of these components over the operational life time of ITER, it is important to determine to the best possible extent the operational power loads and power densities on the various surfaces which are impacted by the beam in one way or the other during its transport. The main factors contributing to these are the divergence of the beamlets and the halo fraction in the beam, the beam aiming, the horizontal and vertical misalignment of the beam, and the gas profile along the beam path, which determines the re-ionisation loss, and the re-ionisation cross sections. The estimations have been made using a combination of the modified version of the Monte Carlo Gas Flow code (MCGF) and the BTR code. The MCGF is used to determine the gas profile in the beam line and takes into account the active gas feed into the ion source and neutraliser, the HNB-DNB cross over, the gas entering the beamline from the ITER machine, the additional gas atoms generated in the beam line due to impacting ions and the pumping speed of the cryopumps. The BTR code has been used to obtain the power loads and the power densities on the various surfaces of the front end components and the duct modules for different scenarios of ITER operation. The gas profile and the magnetic field distribution for each scenario has been considered in these evaluations. The worst case power loads and power densities for each surface have been used to study their thermo-mechanical behaviour and manufacturing feasibility. The details of these calculations and results obtained are presented and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WECC Variable Generation Planning Reference Book: Appendices

The document titled “WECC Variable Generation Planning Reference Book”. This book is divided into two volumes; one is the main document (volume 1)and the other is appendices (volume 2). The main document is a collection of the best practices and the information regarding the application and impact of variables generation on power system planning. This volume (appendices) has additional information on the following topics: Probabilistic load flow problems. 2. Additional useful indices. 3. high-impact low-frequency (HILF) events. 4. Examples of wide-area nomograms. 5. Transmission line ratings, types of dynamic rating methods. 6. Relative costs per MW-km of different electric power transmission technologies. 7. Ultra-high voltage (UHV) transmission. 8.High voltage direct current (VSC-HVDC). 9. HVDC. 10. Rewiring of existing transmission lines. 11. High-temperature low sag (HTLS) conductors. 12. The direct method and energy functions for transient stability analysis in power systems. 13.Blackouts caused by voltage instability. 14. Algorithm for parameter continuation predictor-corrector methods. 15. Approximation techniques available for security regions. 16. Impacts of wind power on power system small signals stability. 17. FIDVR. 18. FACTS. 19. European planning standard and practices. 20. International experience in wind and solar energy sources. 21. Western Renewable Energy Zones (WREZ). 22. various energy storage technologies. 23. demand response. 24. BA consolidation and cooperation options. 25. generator power management requirements and 26. European planning guidelines.

Makarov, Yuri V.↗

Estuarine nutrient pollution impact reduction assessment through euphotic zone avoidance/bypass considerations

The feasibility of reducing nutrient pollution impact by redirecting the effluent to depths below the euphotic zone was investigated for the deep estuarine Puget Sound region of the Salish Sea in the Pacific Northwest of America. The hypothesis tested was that the thickness of the outflow layer in deep estuaries may be greater than the euphotic zone depth, allowing a fraction of nutrients to be exported out passively through the layers immediately below. The euphotic zone depth in Puget Sound varies from 8 to 25 m while the depth of the outflow layer can reach up to ≈ 60 m. Outfall relocation strategies were tested on 99% of the anthropogenic nutrient loads currently delivered to Puget Sound. The impact was quantified using the previously established biophysical Salish Sea Model, using gross primary production and exposure to low dissolved oxygen (DO) levels as the metric (< 2 mg/L for hypoxia and < 5 mg/L for impairment). Eliminating nutrient pollution (above natural) from rivers and wastewater reduced hypoxia exposure by 8.1% and 11.2%, respectively. Relocating the outfalls to deeper waters resulted in improvements, but only in the sill-less sub-basins such as Whidbey, where hypoxia and DO impairment exposure decreased (7.9% and 6.8%, respectively). The presence of multiple sills and circulation cells in Puget Sound resulted in increased exposure and rendered nutrient bypass goals unfeasible as originally envisioned. However, an alternate nutrient export pathway was identified through bottom exchange flow out of Puget Sound via Whidbey Basin and Deception Pass. An unexpected reduction in the exchange outflow magnitude (≈ 4%) due additional (22%) freshwater discharged to the estuary bottom was also noted. The potential loss in circulation strength due to rerouting of natural surface freshwater through submerged deep-water outfalls is identified as a new unforeseen anthropogenic impact.

54 ENVIRONMENTAL SCIENCES↗

Mars dust-driven tides and their impact on the thermosphere

It has been known since the early Mariner 6, 7, and 9 missions that dust loading of the lower atmosphere and the subsequent aerosol heating during dusty periods impacts the martian middle and upper atmospheres. A quantitative measure of this lower atmosphere forcing was obtained by the Viking 1 and 2 landers, from which observed amplitudes of semidiurnal surface-pressure oscillations were correlated with normal-incidence dust optical depths. It appears that the dominant semidiurnal mode is a good indicator of global dust content or mean dust optical depth, especially during dust storm events. A classical tidal model that reproduces the surface pressure oscillations measured by these Viking landers in 1977 was used to calculate tidal amplitudes and phases up to approximately 43 km. These tidal characteristics were calculated for various dust optical depth conditions ranging from typical dusty periods to global dust storm times. Reasonable extrapolations can be made to higher altitudes if one assumes that the vertically propagating tidal modes continue to grow without dissipation or breaking. It is very likely that gravity waves also play an important role in the structure and dynamics of the middle atmosphere of Mars, since the large topographical relief should produce vigorous gravity wave fluxes. Semidiurnal tidal modes, significantly enhanced by lower atmosphere dust-induced heating, may indeed propagate to the Mars thermosphere (approximately less than 100 km) before breaking and generating turbulence. The preferential enhancement of the semidiurnal tides during dust storm onset is primarily due to the elevation of the tidal heating source in a very dusty atmosphere. The (2,2) semidiurnal tidal tidal mode was shown to have the largest variation with dust optical depth, as measured by Viking lander instruments. Also, the (2,2) mode has the largest vertical wavelength of all the semidiurnal tidal modes, and thus is most likely to penetrate into the thermosphere before breaking and to modify the largely in situ solar-driven behavior otherwise expected. The tides may also be partially responsible for determining the height of the martian homopause (approximately 125 km).

Bougher, Stephen W.↗

Recent development in the design, testing and impact-damage tolerance of stiffened composite panels

Structural technology of laminated filamentary-composite stiffened-panel structures under combined inplane and lateral loadings is discussed. Attention is focused on: (1) methods for analyzing the behavior of these structures under load and for determining appropriate structural proportions for weight-efficient configurations; and (2) effects of impact damage and geometric imperfections on structural performance. Recent improvements in buckling analysis involving combined inplane compression and shear loadings and transverse shear deformations are presented. A computer code is described for proportioning or sizing laminate layers and cross-sectional dimensions, and the code is used to develop structural efficiency data for a variety of configurations, loading conditions, and constraint conditions. Experimental data on buckling of panels under inplane compression is presented. Mechanisms of impact damage initiation and propagation are described.

Williams, J. G.↗

TPSAS-NF1676L-13678-DND

An area that shows promise in enhancing structural integrity of aircraft and aerospace structures is integral stitched composite technology. The most recent generation of this technology is the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept. The goal of the PRSEUS concept is to provide damage-containment capability for composite structures while reducing overall structural weight. The National Aeronautics and Space Administration, the Boeing Company, and the Federal Aviation Administration (FAA) have partnered in an effort to assess the damage-containment features of a full-scale curved PRSEUS panel using the FAA Full-Scale Aircraft Structural Test Evaluation and Research facility. The background, test plan, fixture modifications, pre-test analysis, and planned experimental procedure were presented at the 2011 Aircraft Airworthiness and Sustainment Conference. This follow-on paper and presentation will provide details of the experimental procedure, test results, nondestructive inspection results, and preliminary test analysis comparison. The test program included three phases of loading and inspections: Phase I, as-built; Phase II, with barely visible impact damage (BVID); and Phase III, with a two-bay notch severing the central stiffener. Axial tension, internal pressure, and combined axial tension and internal pressure load conditions were applied during each phase using load levels that demonstrate compliance with the strength, deformation, and damage-tolerance requirements of Title 14 Code of Federal Regulations Part 25. Pressure loads were based on an operating pressure of 9.2 psi, designated as 1P, and the axial loads were based on a design limit load (DLL) of 227 kip. The Phase I test results provided a baseline. First, 50 percent limit-load levels were applied for each of the three load cases to verify proper load introduction and repeatability by examining strain and displacement results. Next, three limit-load cases were applied: limit pressure of 12.2 psi (1.33 P), axial DLL of 227 kip, and combined 1P pressure and axial DLL. Linear strain and displacement results were observed in all load cases. For Phase-II testing, the panel was impacted to introduce BVID with an energy of 40 ft-lb, with the impact located between the central stringer stitch line and flange edge. The impact created non-penetrating visual damage with fiber breaks and delamination between the skin and stringer flange. Limit-load conditions were applied followed by pressure overload of 18.4 psi (2P) and ultimate load conditions, defined as 1.5 times DLL. Inspections were performed after each load case; no damage growth was observed. For Phase-III testing, a two-bay notch was machined severing the central stiffener. The panel was then subjected to limit-load conditions, followed by combined 1P pressure while increasing axial tension load to catastrophic failure. As limit combined loads were approached, damage initiation was observed in the form of 45? splitting at 1P + 79% DLL. Axial loading was increased to 1P + 150 percent DLL causing damage to propagate to the adjacent stringer flanges. Damage was contained within the two-bay region by the stitching rows up to 1P + 176% DLL. Axial load was further increased until catastrophic failure, when a stringer rod failed at 1P + 192% DLL. These test results further verify the damage containment features of the PRSEUS concept and suggest its appropriateness for future flight vehicles.

Andrew Bergan↗

Interaction between Heat Pump Water Heaters or Other Internal Point Source Loads and a Central Heating System

Water heating represents approximately 18% of residential energy consumption, or 4.6 quadrillion Btus of source energy use annually (EIA 2009). Heat pump water heaters (HPWHs) offer an efficient option for residential water heating, with the ability to reduce water heating energy consumption by up to 63%. Previous research has demonstrated the laboratory performance of HPWHs and has shown savings of 43 to 62% on water heating energy consumption are possible, based on field tests (Ecotope 2015). In order to achieve such high efficiencies, HPWHs employ a refrigeration cycle to move heat from the ambient air into the water. Therefore, when HPWHs are installed in conditioned space, they will remove heat from that space which can help the HVAC system in the cooling season and require additional energy from the HVAC system in the heating season. This project provides an unbiased evaluation of the space conditioning interactions between a HPWH and the heating system in several locations throughout the home to further our understanding of the impact that HPWHs have on space conditioning loads. This report explores the HPWH interaction factor from several perspectives: (1) a theoretical analysis, (2) a review of previous literature, and (2) an experimental assessment. The experiments were conducted in PNNL’s side-by-side Lab Homes, which provide a platform for evaluating energy-saving and grid-responsive technologies in a controlled environment. The PNNL Lab Homes are two factory-built homes installed on PNNL’s campus in Richland, Washington. The homes represent existing homes, which account for approximately 99% of occupied homes in the U.S. These 1500 ft2 homes have three bedrooms, two bathrooms, and are equipped with 7.7 HSPF heat pump and an electric forced air furnace. Both homes have R-22 floors, R-11 walls and R-22 ceiling insulation levels, with double-pane clear glass windows. The results of this experiment verified that the energy use of the HVAC system increases as a point source cooling load, like a HPWH, is moved closer to the thermostat. The opposite is also true, as a point source heating load is moved closer to the thermostat, the heating load decreases. The results show between 30-40% difference between the interaction that this type of load has when it is placed in the master bathroom compared to the living room for the PNNL Lab Homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiscale Effects Masked the Impact of the COVID-19 Pandemic on Electricity Demand in the United States

Shelter-in-place orders and business closures related to COVID-19 changed the hourly profile of electricity demand and created an unprecedented source of uncertainty for the grid. The potential for continued shifts in electricity profiles has implications for electricity sector investment and operating decisions that maintain reserve margins and provide grid reliability. This study reveals that understanding this uncertainty requires an understanding of the underlying drivers at the customer-class scale. This paper utilizes three datasets to compare the impacts of COVID-19 on electricity consumption across a range of spatiotemporal and customer scales. At the utility/customer-class scale, COVID-19-induced shutdowns in the spring of 2020 shifted weekday residential load profiles to resemble weekend profiles from previous years. Total commercial loads declined, but the commercial diurnal load profile was unchanged. With only total loads available at the balancing authority scale, the apparent impact of COVID-19 was smaller during the summer due in part to phased re-opening and spatial variability in re-opening, but there were still clear variations once total loads were broken down zonally. Monthly data at the state scale showed an increase in state-level residential electricity sales, a decrease in commercial sales, and a small net decrease in total sales in most states from April-August 2020. Analyses that focus on total load or a single scale may miss important changes that become apparent when the load is broken down regionally or by customer class.

COVID-19, electricity demand, multiscale, Commonwe↗

Hypervelocity Impact Test Facility: A gun for hire

An affordable technique has been developed to duplicate the types of impacts observed on spacecraft, including the Shuttle, by use of a certified Hypervelocity Impact Facility (HIF) which propels particulates using capacitor driven electric gun techniques. The fully operational facility provides a flux of particles in the 10-100 micron diameter range with a velocity distribution covering the space debris and interplanetary dust particle environment. HIF measurements of particle size, composition, impact angle and velocity distribution indicate that such parameters can be controlled in a specified, tailored test designed for or by the user. Unique diagnostics enable researchers to fully describe the impact for evaluating the 'targets' under full power or load. Users regularly evaluate space hardware, including solar cells, coatings, and materials, exposing selected portions of space-qualified items to a wide range of impact events and environmental conditions. Benefits include corroboration of data obtained from impact events, flight simulation of designs, accelerated aging of systems, and development of manufacturing techniques.

Johnson, Calvin R.↗

Operational impacts of high penetration solar power on a real-world distribution feeder

Higher penetration of solar photovoltaic (PV), with their uncontrollable generation variability, imposes various grid stability challenges on distribution system operation. The primary problem is significant voltage rise in the distribution feeder that forces existing voltage control devices such as on-load tap-changers and line voltage regulators to operate more frequently. The consequence is the deterioration of the operating life of the voltage control mechanism. The objective of this paper is to investigate the voltage impact of increased penetration of PV systems on distribution load tap changer operations. Both steady-state and quasi-static power flow analyses have been conducted to assess the impact on load tap changes under different solar PV penetration levels. Two real-world distribution feeder circuits are used as a test system in this study. Simulations are carried out for up to one-year period with 1-minute time step using OpenDSS. A comparison study was performed to investigate potential voltage rise issues in the network by increasing total PV penetration from 0 to 100% in the feeder. Results show significant increase in the total number of tap operations as solar PV penetration increases. Impacts on nodal voltages and feeder net power are also presented.

Dong, Jin↗

A superelement methodology for coupled loads analysis of Space Station Freedom

A technique for calculating the effects of on-orbit loads on the structural dynamics of the International Space Station is developed on the basis of MSC/NASTRAN superelement solution sequences. The complexity of the Space Station program with its multiple configurations, international partners, and contractors is stressed, and the impact of this complexity on the dynamic-load analysis process is indicated. The MSC/NASTRAN-based approach is outlined, and its application to two versions of the Permanent Manned Capability configuration is described in detail, including component mode synthesis, GFSC/FLAME coupled-loads analysis (with components from the system FEM model or from the Work Package), and ISI/MATRIX-X generation of closed-loop forcing functions. The results of these sample analyses are presented in extensive tables and graphs and briefly characterized.

Del Basso, Steve↗

Comparison of Fuel Loading Pattern Optimization Results using Exhaustive Search for Fresh Fuels and Local Search for Burned Fuels

Fuel loading pattern optimization is a combinatorial optimization problem from the mathematical point of view. However, exhaustive search is impractical because enormous computational cost is necessary due to huge search space. For this reason, various optimization methods have been developed so far, but no methods are able to guarantee to reach the optimum solution. In the present study, search space is divided into subspaces using key parameters that well represent characteristics of a loading pattern and then promising subspaces are extensively searched. In the present method, balance between division of a search space into subspaces and a search method used in a subspace is essential. For example, when the number of division is set to be one, it is equivalent to the exhaustive search thus is impractical. Similarly, when the division to subspaces is too coarse, an optimum (or near optimum) solution cannot be found through local search in each subspace since design space of a subspace is still too large. Contrary, if division to subspaces is too fine, number of subspaces becomes to large thus promising subspaces cannot be found. In the present study, search space is divided focusing on the location of fresh fuel assemblies with gadolinia since it has significant impact on core characteristics. Number of possible loading patterns of gadolinia bearing fresh fuel assemblies is not very large thus exhaustive search is possible. Local fine search is executed by considering location of burned fuels for each loading pattern of gadolinia bearing fresh fuel assembly. If the same solution is obtained by multiple local searches starting from different initial burnt fuel locations (but the same loading patterns for gadolinia bearing fresh fuel assemblies), the obtained solution is highly likely the optimum in the subspace. In more general, the present method is based on the 'divide and conquer' approach, which is familiar in the optimization field. Namely, after division of search space into subspaces and then promising subspace is searched. Once the promising subspace is found, the subspace is further subdivided into subspaces and repeat the above procedures. This method would be efficient when appropriate balance between search space division method and performance of local search is achieved. The previous works utilizes the similar approach. In reference [1], exhaustive search in small region in a core is carried out focusing on loading patterns of gadolinia bearing fresh fuel assemblies. In reference [2], rough exhaustive search based on the 'batch-wise' loading pattern is performed with the assist of the linear programming. By contrast, in the present study, exhaustive search is carried out for loading patterns of gadolinia bearing fresh fuel assemblies. The random Multi-start Local Search (MSLS) with the direct search or the exhaustive binary swap is used to find out optimal solutions in a subspace, which consists of loading patterns having the same arrangement of gadolinia bearing fresh fuel assemblies. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of Graft Molecular Weight and Density on the Mechanical Properties of Polystyrene-Grafted Cellulose Nanocrystal Films

In this work, polymer-grafted nanoparticle (PGN) films were prepared from polystyrene (PS) grafted to rodlike cellulose nanocrystals (MxG-CNC-g-PS) with a controllable grafting density (0.03–0.25 chains/nm 2 ) and molecular weight (5–60 kg/mol). These nanorod-based PGNs are solution- and melt-processible, permitting access to one-component composite films with high nanofiller loadings (with up to 55 wt %). The impact of both grafted polymer density and molecular weight on the mechanical properties of the films was investigated and related to the polymer brush conformation: concentrated polymer brush (CPB), semidilute polymer brush (SDPB), or CPB core with SDPB corona (CPB/SDPB). The rubbery regime storage modulus (above $T_g$) showed 2 orders of magnitude increase, maximizing at a low degree of polymerization (N) and low grafting density (σ). Fracture toughness was maximized in samples with the grafted polymer in the SDPB or CPD/SDPB (higher N and relatively low σ) regime and showed enhancement relative to PS of molecular weight similar to the graft. In line with prior computation predictions, optimizing for both rubbery modulus and fracture toughness in such nanorod-based PGN films requires the polymers in the SDPB regime and CNC loading levels (ca. 50–60 wt %) that are difficult to attain in more traditional two-component CNC composites.

36 MATERIALS SCIENCE↗

Investigation of Membrane Chemical Degradation as a Function of Catalyst Platinum Loading

Membrane chemical degradation is one of many factors that can impact fuel cell durability. Additionally, the fuel cell’s lifetime heavily depends on the membrane and its ability to maintain chemical and mechanical integrity. Previous studies indicate that chemical degradation is due to the formation of hydroxyl radicals that attack the polymer structure resulting in membrane thinning, pinhole formation, and the release of fluoride and sulfate ions. Membrane durability was investigated using ultra-low Pt electrode loadings (≤ 0.1 mg Pt cm -2 ). Accelerated stress testing (US-DOE protocols) demonstrated that the degradation rate was found to increase with higher Pt loadings. This is most likely due to more heterogeneous sites for radical formation due to hydrogen crossover to the cathode. We also explored membrane degradation rates while varying catalyst layer thickness, ionomer to carbon ratio, and types of carbon support. All of the aforementioned variables impact the membrane degradation rates.

25 ENERGY STORAGE↗

Bombardment of planetary rings by meteoroids - General formulation and effects of Oort Cloud projectiles

A general solution is obtained for the angular distribution of the intensity and velocity of interplanetary projectiles impinging on a planetary ring system. Three significant results emerge from the solution: (1) a variation with orbital longitude is demonstrated in the impact velocity-weighted impact rate of the planetary rings' cometary meteoroids; (2) the angular distribution of ejecta intensity due to the bombardment of a planetary ring by interplanetary meteoroids is determined; and (3) the radial drift velocity due to both simple mass-loading and aberration-induced asymmetry in the impact rate is calculated for a planetary ring of arbitrary optical depth. Attention is given to results for projectiles with Oort Cloud-type orbits.

Cuzzi, Jeffrey N.↗

Computer Modeling of Sand Transport on Mars Using a Compart-Mentalized Fluids Algorithm (CFA)

It has been postulated that aeolian transport on Mars may be significantly different from that on Earth. From laboratory experiments simulating martian grain transport [2], it has been observed that (saltating) grains striking the bed can cause hundreds of secondary reptation trajectories when impact occurs at speeds postulated for Mars. Some of the ballistically induced trajectories "die ouf' and effectively join the ranks on the creep population that is merely nudged along by impact. Many of the induced reptation trajectories, however, are sufficiently high for the grains to become part of the saltation load (it is irrelevant to the boundary layer how a grain attained its initial lift force). When these grains, in turn, strike the surface, they too are capable of inducing more reptating grains. This cascading effect has been discussed in connection with terrestrial aeolian transport in an attempt to dispel the notion that sand motion is divisible only into creep and saltation loads. On Earth, only a few grains are splashed by impact. On Mars, it may be hundreds. We developed a computer model to address this phenomenon because there are some important ramifications: First, this ratio may mean that martian aeolian transport is dominated by reptation flux rather than saltation. On Earth, the flux would be a roughly balanced mixture between reptation/creep and saltation. On Venus, there would be no transport other than by saltation. In other words, an understanding of planetary aeolian processes may not be necessarily understood by extrapolating from the "Earth case", with only gravity and atmospheric density/viscosity being considered as variables. Second, the reptation flux on Mars may be self sustaining, so that little input is required by the wind once transport has been initiated. The number of grains saturating the boundary layer near the bed may mean that average grain speed on Mars might conceivably be less than that on Earth. This would say much for models of sand comminution on Mars. A multiple-grain transport model using just the equations of grain motion describing lift and drag is impossible to develop owing to stochastic effects --the very effects we wish to model. Also, unless we were to employ supercomputing techniques and extremely complex computer codes that could deal with millions of grains simultaneously, it would also be difficult to model grain transport if we attempted to consider every grain in motion. No existing computer models were found that satisfactorily used the equations of motion to arrive at transport flux numbers for the different populations of saltation and reptation. Modeling all the grains in a transport system was an intractable problem within our resources, and thus we developed what we believe to be a new modeling approach to simulating grain transport. The CFA deals with grain populations, but considers them to belong to various compartmentalized fluid units in the boundary layer. In this way, the model circumvents the multigrain problem by dealing primarily with the consequences of grain transport --momentum transfer between air and grains, which is the physical essence of a dynamic grain-fluid mixture. We thus chose to model the aeolian transport process as a superposition of fluids. These fluids include the air as well as particle populations of various properties. The prime property distinguishing these fluids is upward and downward grain motion. In a normal saltation trajectory, a grain's downwind velocity increases with time, so a rising grain will have a smaller downwind velocity than a failing grain. Because of this disparity in rising and falling grain proper-ties, it seemed appropriate to track these as two separate grain populations within the same physical space. The air itself can be considered a separate fluid superimposed within and interacting with the various grain-cloud "fluids". Additional informaiton is contained in the original.

Marshall, J.↗

Building Energy Systems as Behind-the-Meter Resources for Grid Services: Intelligent load control and transactive control and coordination

To mitigate the impacts of climate change, significant reductions in emissions from all sectors of the economy are needed. The electricity generation sector has embarked on an ambitious plan to include renewable generation as part of its decarbonization efforts, and many cities and states are mandating all-electric buildings. While renewable resources will reduce emissions, they are not dispatchable, they vary temporally, and their generation is uncertain. Under these conditions, traditional approaches to managing grid reliability, where supply follows demand, will not be efficient and may not be cost-effective. Further, there is a more efficient alternative for balancing the supply–demand imbalance and for absorbing variability and uncertainty of renewable energy using distributed energy resources (DERs) as opposed to reserve generation. Because buildings consume more than 75% of total U.S. annual electricity consumption, behind-the-meter (BTM) DERs have a load flexibility of 77 GW of power and 90 GWh of virtual energy storage capacity nationwide (Kalsi, 2017). Therefore, some portion of the supply–demand imbalance can be met by these DERs at a lower cost compared to business-as-usual solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗