Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inlets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Status Report on the High-Temperature Steam Electrolysis Plant Model Developed in the Modelica Framework (FY17)

This report has been prepared as part of an effort to design and build a modeling and simulation (M&S) framework to assess the economic viability of a nuclear-renewable hybrid energy system (N-R HES). In order to facilitate dynamic M&S of such an integrated system, research groups in multiple national laboratories have been developing various subsystems as dynamic physics-based components using the Modelica programming language. In fiscal year 2015 (FY15), Idaho National Laboratory (INL) performed a dynamic analysis of two region-specific N-R HES configurations, including the gas-to-liquid (natural gas to Fischer-Tropsch synthetic fuel) and brackish water reverse osmosis desalination plants as industrial processes. In FY16, INL developed two additional subsystems in the Modelica framework: (1) a high-temperature steam electrolysis (HTSE) plant as a high priority industrial plant to be integrated with a light water reactor (LWR) within an N-R HES and (2) a gas turbine power plant as a secondary energy supply. In FY17, five new components (i.e., a feedwater pump, a multi-stage compression system, a sweep-gas turbine, flow control valves, and pressure control valves) have been incorporated into the HTSE system proposed in FY16, aiming to better realistically characterize all key components of concern. Special attention has been given to the controller settings based on process models (i.e., direct synthesis method), aiming to improve process dynamics and controllability. A dynamic performance analysis of the improved LWR/HTSE integration case was carried out to evaluate the technical feasibility (load-following capability) and safety of such a system operating under highly variable conditions requiring flexible output. The analysis (evaluated in terms of the step response) clearly shows that the FY17 model resulted in superior output responses with much smaller settling times and less oscillatory behavior in response to disturbances in the electric load than those observed with the FY16 model. Simulation results involving several case studies show that the suggested control scheme could maintain the controlled variables (including the steam utilization factor, cathode stream inlet composition, and temperatures and pressures of the process streams at various locations) within desired limits under various plant operating conditions. The results also indicate that the proposed HTSE plant could provide operational flexibility to participate in energy management at the utility scale by dynamically optimizing the use of excess plant capacity within an N-R HES.

08 HYDROGEN↗

Final Report: Utilizing Alternative Fuel Ignition Properties to Improve SI and CI Engine Efficiency

Experimental and modeling studies were completed to explore leveraging physical and chemical fuel properties for improved thermal efficiency of internal combustion engines. Fundamental studies of the ignition chemistry of ethanol and iso-octane blends and constant volume spray chamber studies of gasoline and diesel sprays supported the core research effort which used several reciprocating engine platforms. Single cylinder spark ignition (SI) engine studies were carried out to characterize the impact of ethanol/gasoline, syngas (H 2 and CO)/gasoline and other oxygenate/gasoline blends on engine performance. The results of the single-cylinder engine experiments and other data from the literature were used to train a GT Power model and to develop a knock criteria based on reaction chemistry. The models were used to interpret the experimental results and project future performance. Studies were also carried out using a state of the art, direct injection (DI) turbocharged multi- cylinder engine with piezo-actuated fuel injectors to demonstrate the promising spray and spark timing strategies from single-cylinder engine studies on the multi-cylinder engine. Key outcomes and conclusions of the studies were: 1. Efficiency benefits of ethanol and gasoline fuel blends were consistent and substantial (e.g. 5-8% absolute improvement in gross indicated thermal efficiency (GITE)). 2. The best ethanol/gasoline blend (based on maximum thermal efficiency) was determined by the engine hardware and limits based on component protection (e.g. peak in-cylinder pressure or maximum turbocharger inlet temperature) – and not by knock limits. Blends with <50% ethanol delivered significant thermal efficiency gains with conventional SI hardware while maintain good safety integrity to the engine hardware. 3. Other compositions of fuel blends including syngas (H 2 and CO) and other dilution strategies provided significant efficiency gains as well (e.g. 5% absolute improvement in ITE). 4. When the combination of engine and fuel system is not knock limited, multiple fuel injection events maintain thermal efficiency while improving engine-out emissions (e.g. CO, UHC, and particulate number).

33 ADVANCED PROPULSION SYSTEMS↗

An Investigation into Solution Verification for CFD-DEM

This report presents the study of the convergence behavior of the computational fluid dynamicsdiscrete element method (CFD-DEM) method, specifically National Energy Technology Laboratory’s (NETL) open source MFiX code (MFiX-DEM) with a diffusion based particle-tocontinuum filtering scheme. In particular, this study focused on determining if the numerical method had a solution in the high-resolution limit where the grid size is smaller than the particle size. To address this uncertainty, fixed particle beds of two primary configurations were studied: i) fictitious beds where the particles are seeded with a random particle generator, and ii) instantaneous snapshots from a transient simulation of an experimentally relevant problem. Both problems considered a uniform inlet boundary and a pressure outflow. The CFD grid was refined from a few particle diameters down to 1/6 th of a particle diameter. The pressure drop between two vertical elevations, averaged across the bed cross-section was considered as the system response quantity of interest. A least-squares regression method was used to extrapolate the grid-dependent results to an approximate “grid-free” solution in the limit of infinite resolution. The results show that the diffusion based scheme does yield a converging solution. However, the convergence is more complicated than encountered in simpler, single-phase flow problems showing strong oscillations and, at times, oscillations superimposed on top of globally non-monotonic behavior. The challenging convergence behavior highlights the importance of using at least four grid resolutions in solution verification problems so that (over-determined) regression-based extrapolation methods may be applied to approximate the grid-free solution. The grid-free solution is very important in solution verification and VVUQ exercise in general as the difference between it and the reference solution largely determines the numerical uncertainty. By testing different randomized particle configurations of the same general problem (for the fictitious case) or different instances of freezing a transient simulation, the numerical uncertainties appeared to be on the same order of magnitude as ensemble or time averaging uncertainties. By testing different drag laws, almost all cases studied show that model form uncertainty in this one, very important closure relation was larger than the numerical uncertainty, at least with a reasonable CFD grid, roughly five particle diameters. In this study, the diffusion width (filtering length scale) was mostly set at a constant of six particle diameters. A few exploratory tests were performed to show that similar convergence behavior was observed for diffusion widths greater than approximately two particle diameters. However, this subject was not investigated in great detail because determining an appropriate filter size is really a validation question which must be determined by comparison to experimental or highly accurate numerical data. Future studies are being considered targeting solution verification of transient simulations as well as validation of the filter size with direct numerical simulation data.

97 MATHEMATICS AND COMPUTING↗

Internally Cooled Turbine Rotor for Small Gas Turbine

In collaboration with Brayton Energy LLC, ORNL worked to develop the necessary processing science for the high-gamma prime Ni-base superalloy CM247 for advanced small turbine applications. Preliminary monotonic testing indicated the behavior of electron beam melted (EBM) CM247 achieved similar properties of the cast counterpart. Brayton has applied these results to both radial and small axial turbine rotor designs. Preliminary results indicate that measurable increases in turbine inlet temperature may be achieved while respecting aerodynamic constraints.

42 ENGINEERING↗

Analysis of Dust Samples Collected from an In-Service Interim Storage System at the Maine Yankee Nuclear Site.

In July, 2016, the Electric Power Research Institute and industry partners performed a field test at the Maine Yankee Nuclear Site, located near Wiscasset, Maine. The primary goal of the field test was to evaluate the use of robots in surveying the surface of an in-service interim storage canister within an overpack; however, as part of the demonstration, dust and soluble salt samples were collected from horizontal surfaces within the interim storage system. The storage system is a vertical system made by NAC International, consisting of a steel-lined concrete overpack containing a 304 stainless steel (SS) welded storage canister. The canister did not contain spent fuel but rather greater-than-class-C waste, which did not generate significant heat, limiting airflow through the storage system. The surfaces that were sampled for deposits included the top of the shield plug, the side of the canister, and a shelf at the bottom of the overpack, just below the level of the pillar on which the canister sits. The samples were sent to Sandia National Laboratories for analysis. This report summarizes the results of those analyses. Because the primary goal of the field test was to evaluate the use of robots in surveying the surface of the canister within the overpack, collection of dust samples was carried out in a qualitative fashion, using paper filters and sponges as the sampling media. The sampling focused mostly on determining the composition of soluble salts present in the dust. It was anticipated that a wet substrate would more effectively extract soluble salts from the surface that was sampled, so both the sponges and the filter paper were wetted prior to being applied to the surface of the metal. Sampling was accomplished by simply pressing the damp substrate against the metal surface for two minutes, and then removing it. It is unlikely that the sampling method quantitatively collected dust or salts from the metal surface; however, both substrates did extract a significant amount of material. The paper filters collected both particles, trapped within the cellulose fibers of the filter, and salts, while the sponges collected only the soluble salts, with very few particles. Upon delivery to Sandia, both collection media were analyzed using the same methods. The soluble salts were leached from the substrates and analyzed via ion chromatography, and insoluble minerals were analyzed by scanning electron microscopy and energy dispersive X-ray spectroscopy. The insoluble minerals were found to consist largely of terrestrially-derived mineral fragments, dominantly quartz and biotite. Large (mm-sized) aggregates of calcium carbonate, calcium silicate, and calcium aluminum silicate were also present. The aggregates had one flat, smooth surface and one well crystallized surface, and were interpreted to be efflorescence on the inside of the overpack and in the vent, formed by seepage of cement pore fluids through joints in the steel liner of the overpack. Such efflorescence was commonly observed during the boroscope inspection of the storage system at the site. The material may have flaked off and fallen to the point where the dust was collected, or may have brushed off onto the sponges when the robot was retrieved through the inlet vent. Chemical analysis showed that the soluble salts on the shield plug were Ca- and Na-rich, with lesser K and minor Mg; the anionic component was dominated by SO 4 and Cl, with minor amounts of NO 3 . The cation composition of the soluble salts from the overpack shelf and the canister surface was similar to the filter samples, but the anions differed significantly, being dominantly NO 3 with lesser Cl and only trace SO 4 . The salts appear to represent a mixture of sea-salts (probably partially converted to nitrates and sulfates by particle-gas conversion reactions) and continental salt aerosols. Ammonium, a common component in continental aerosols, was not observed and may have been lost by degassing from the canister surface or after collection during sample storage and transportation. The demonstration at Maine Yankee has shown that the robot and sampling method used for the test can successfully be used to collect soluble salts from metal surfaces within an interim storage system overpack. The results were consistent from sample to sample, suggesting that a representative sample of the soluble salts was being collected. However, it is unlikely that the salt samples collected here represent quantitative sampling of the salts on the surfaces evaluated; for that reason, chloride densities per unit area are not presented here. It should also be noted that the relevance to storage systems at the site that contain SNF may be limited, because a heat- generating canister will result in greater airflow through the overpack, affecting dust deposition rates and possibly salt compositions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coiled Tube Gas Heaters For Nuclear Gas-Brayton Power Conversion

This project developed an alternative design for heat exchangers for application to heating supercritical carbon dioxide (S-CO 2 ) or air for power conversion. We have identified an annular coiled tube bundle configuration–where hot sodium enters tubes from multiple vertical inlet manifold pipes, flows in a spiral pattern radially inward and downward, and then exits into an equal number of vertical outlet manifold pipes–as a potentially attractive option. The S-CO 2 gas or air flows radially outward through the tube bundle. Coiled tube gas heaters (CTGHs) are expected to have excellent thermal shock, long-term thermal creep, in-service inspection, and reparability characteristics, compared to alternative options. CTGHs have significant commonality with modern nuclear steam generators. Extensive experience exists with the design, manufacture, operation, in-service inspection and maintenance of nuclear steam generators. The U.S. Nuclear Regulatory Commission also has extensive experience with regulatory guidance documented in NUREG 0800. CTGHs leverage this experience and manufacturing capability. The most important difference between steam generators and gas-Brayton cycles such as the S-CO 2 cycle is that the heat exchangers must operate with counter flow with high effectiveness to minimize the pinch-point temperature difference between the hot liquid coolant and the heated gas. S-CO 2 -cycle gas heaters also operate at sufficiently elevated temperatures that time dependent creep is important and allowable stresses are relatively low. Designing heat exchangers to operate in this regime requires configurations that minimize stresses and stress concentrations. The cylindrical tubes and cylindrical manifold pipes used in CTGHs are particularly effective geometries. The first major goal of this research project was to develop and experimentally validate a detailed, 3-D multi-phase (gas-solid-liquid) heat transport model for CTGHs, using methods similar to earlier UCB multi-scale models for PCHEs, which will enable optimization of CTGH designs with respect to the number of manifold pipes, S-CO 2 and sodium circulating power, and other design parameters. CTGHs are relatively novel because the tubes loaded in compression as well as the manifold pipes which form the tube sheets. The second major goal of the experimental and modeling effort was to optimize the assembly and heat treatment of the tube-to-tubesheet joints, using a novel tapered joint configuration, and to develop diffusion-bonded joints with high shear strength and creep resistance, as has been done in other applications for tapered plugs. The project would also conduct creep testing of these tubesheet joints in pressurized furnaces under prototypical conditions of stress and temperature, however this was not feasible due to numerous hinderances. Detailed microstructural investigations was conducted on the diffusion bond interface, while the bond strength was evaluated by tensile testing. The mechanical testing quantified the overall strength of the bond and measured the pull out force as well as long term behavior, which complemented the microstructural analysis and gave a complete understanding of the diffusion bond.

30 DIRECT ENERGY CONVERSION↗

High-resolution time-resolved experiments on mixing and entrainment of buoyant jets in stratified environments

Fluid jets interacting with a stratified layer play an important role in the safety of several reactor designs. In the containment of nuclear power plants, fluid jets dominate the transport and mixing of gaseous species and consequent hydrogen distribution in case of a severe accident. The mixing phenomena in the containment are driven by buoyant high-momentum injections (jets) and low momentum injection plumes. Mixing near the postulated break is initially dominated by high flow velocities. Plumes with moderate flow velocities are instead relevant in the break compartment during the long-term pressurization phase, or in any of the apertures between two connected compartments if the mass flows are sufficiently high and the density differences between efflux and ambient are sufficiently low. Phenomena of interest include free plumes (as produced by the efflux from the break compartment in a larger room or directly from a break flow), wall plumes (such those produced by low mass flows through inter-compartment apertures), and propagating stratification fronts in the ambient (for any stably stratified conditions). These phenomena have been highly ranked about nuclear reactor design, especially regarding of safety protocols. During a Pressurized Thermal Shock (PTS) scenario, the interaction between the cold ECCS injection plume and the stratified fluid present in the cold (or hot) leg is important in order to determine the temperature at the time-dependent temperature at the inlet of the reactor pressure vessel (RPV) and the potential to cause a thermal shock on the RPV wall. In sodium-cooled fast reactors (SFRs), core channels are typically hydro-dynamically isolated so that there exists a considerable temperature variation at the exit of adjacent fuel assemblies. All the above phenomena are characterized by the interaction of buoyant jets with the stratified flow. In stratified layers baroclinic forces create significant redistribution of turbulent kinetic energy and scales, which leads to anisotropy. This important physical phenomenon is highly three dimensional and is challenging to capture even with high-fidelity CFD simulations, due in part to lack of sufficiently resolved validation data. Furthermore, the experimental data available in the open literature do not feature the level of fidelity needed for an extensive validation of turbulence models in lower order CFD. To shed new lights into the crucial phenomena object of the present research project, it was proposed to conduct coordinated experiments and simulations at the University of Michigan and the George Washington University. The project has resulted in an experimental database of high-resolution time-resolved measurements of jets in uniform and stratified environments. The novel experimental data will be used to validate computational fluid dynamic (CFD) codes, including both Large Eddy Simulations (LES) and unsteady Reynolds-averaged Navier-Stokes equations (URANS) methodologies. In the Experimental and Multiphase flow (ECMF) laboratory at Univerisity of Michigan, we built two experimental facilities to investigate also the effect of scaling. The first facility, DESTROJER (DEnsity Stratified Turbulent ROund free Jet ExpeRiment), featuring a contoured jet nozzle with a diameter of D=12.7mm and a 1m×1m×1m cubic tank, which is made of acrylic glass for optical access. The ratio between the tank width and the nozzle diameter is equal to 78, which ensures that there is no direct interaction between the jet and the side walls. A second, modular experimental facility, features three different tank sizes of size 10×10×30, 20×20×30, 30×30×30 cm3 respectively (all tanks have the same height of 30 cm), and a jet diameter of 2mm. For the modular facility, tank-to-nozzle ratio of 50, 100, and 150 are obtained respectively. Experiments with different-density jet impactions and sharp interface with a density difference of 3.16% In the Laboratory at George Washington University, complementary experiments have been carried out at a facility featuring the same dimensions as DESTROYER. Experiments with different jet diameters have been carried out as well. High-resolution time-resolved measurements have been performed at all facilities using high-speed particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF). In this way, simultaneous measurements of velocity and density fields have been carried out. At the University of Michigan, wire-mesh sensors have been designed and built to gather high-resolution, time-dependent data of the stratified front in the tank. These measurements are important to provide accurate initial conditions for the CFD simulations. An important outcome of the project has been the development of novel techniques to achieve refractive index matching (RIM) of acqueous solutions with high density differences. RIM is crucial if optical techniques such as PIV are used to measure velocity fields. Previous to this project, experiments up to 3% density difference had been reported in the literature. With the methodology developed in this project, we have been able to push the envelop to density differences up to 9%. The experiments have been used to validate Reynolds Averaged Navier-Stokes (RANS) turbulence models and Large Eddy Simulations (LES) models. Both NEK5000 and the commercial CFD code STAR-CCM+ have been used. The experimental data will be made available to the community through the NE-KAMS databasehave been successfully conducted in the scaled facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Hybrid Membranes for Next Generation PEMFC Automotive Applications

The objective of this proposal is to fabricate a low cost high performance hybrid inorganic/polymer membrane that has a proton area specific resistance (ASR) < 0.02 ohm cm 2 at the operating temperature of an automotive fuel cell stack (95 - 120°C) at low inlet RH <50% with good mechanical and chemical durability. Additionally the membrane will be optimized for low hydrogen and oxygen crossover with high electrical ASR at all temperatures and adequate proton ASR at lower temperatures. We also seek to gain valuable insights into rapid proton transport at the limit of proton hydration. Additional research will be performed to incorporate the membrane into a 50 cm 2 membrane electrode assembly (MEA). The materials at the start of this project are at a TRL of 2, as we have shown that they have proton conductivity under high and dry conditions, but we have not yet consistently shown that they will function in an operational fuel cell. At the project’s end the materials will be at a TRL of 4 and will be integrated into an MEA, demonstrating that they can function with electrodes as a single fuel cell.

30 DIRECT ENERGY CONVERSION↗

Evaluation of flow and heat transfer inside lean pre-mixed combustor systems under reacting flow conditions

The objective of the present work was to develop methodologies to measure heat transfer within a reacting gas turbine combustor. To accomplish this, an optically accessible research combustor system was designed and constructed at Virginia Tech, capable of operating at 650 K inlet temperature, maximum air mass flow rates of 1.3 kg/s, and flame temperatures over 1800 K. Flow and heat transfer measurements at non-reacting and reacting conditions were carried out for Reynolds numbers (Re) with respect to the combustor diameter ranging from ~11 500 to ~140 000 (depending on the condition). Particle Image Velocimetry (PIV) was used to measure the non-reacting flow field within the burner, leading to the identification of coherent structures in the flow that accounted for over 30% of the flow fluctuation kinetic energy along the swirling jet shear layers. The capability of infrared (IR) thermography to image surface temperatures through a fused silica (quartz) glass was demonstrated at non-reacting conditions. IR thermography was then used to measure the non-reacting steady state heat transfer along the combustor liner. A peak in heat transfer was identified at ~1 nozzle diameter downstream of the combustor dome plate. The peak Nusselt number along the liner was over 18 times higher than that predicted from fully developed turbulent pipe flow correlations, which have traditionally been used to estimate flame side combustor heat transfer. For the reacting measurements, a novel time-dependent heat transfer methodology was developed that allowed for the investigation of transient heat loads, including those occurring during engine ignition and shutdown. The methodology was validated at non-reacting conditions, by comparing results from an experiment with changing flow temperature, to the results obtained at steady state. The difference between the time-dependent and the steady state measurements were between 3% and 17.3% for different mass flow conditions. The time-dependent methodology was applied to reacting conditions for combustor Reynolds numbers of ~12 000 and ~24 000. At an equivalence ratio of ~0.5 and a combustor Reynolds number of ~12 000, the peak heat load location in reaction was shifted downstream by 0.2 nozzle diameters compared to the non-reacting cases. At higher equivalence ratios, and more visibly at a Reynolds number of ~24 000, the heat transfer distribution along the combustor liner exhibited two peaks, upstream and downstream of the impingement location (X/DN = 0.8-1.0 and X/DN ≈ 2.5). Reacting PIV was performed at Re = 12 000 showing the presence of a strong corner recirculation, which could potentially convect reactants upstream of the impingement point, leading to the double peak structure observed. The methodologies developed have provided insight into heat transfer within gas turbine combustors. The methods can be used to explore additional conditions and expand the dataset beyond what is presented, to fully characterize reacting combustor heat transfer.

42 ENGINEERING↗

Improvements in the reactor core isolation cooling (RCIC) pump model

As part of the efforts to understand the unexpected “self-regulating” mode of the RCIC (Reactor Core Isolation Cooling) systems that was observed during the Fukushima accidents and to extend BWR RCIC and PWR AFW (Auxiliary Feed Water) operational range and flexibility, mechanistic models for the Terry turbine are being developed and tested with the RELAP-7 code to simulate the RCIC system. In the previous work, we developed a set of analytical models for the normal working conditions, as well as the two-phase off-design conditions, of the RCIC system, based on Sandia’s original work. An under-expanded jet model was developed to replace the CFD-based reduced-order model in the Sandia work to obtain the velocity and thermodynamic conditions of the turbine stator inlet. The models include both an adiabatic expansion process inside the nozzle and a free expansion process outside of the nozzle to ambient pressure. For the two-phase off-design conditions, two well-established choking models were used - the Isentropic Homogenous Equilibrium Model (IHEM) and Moody’s model. The new twophase Terry turbine model used the choking models to calculate the mass flow rate, the critical pressure at the nozzle throat, and steam quality. The two-phase nozzle expansion model was also developed by considering the vapor phase with a similar model for the single-phase case with the assumption that the liquid phase would slip along the wall with a much slower speed and will not contribute to the impulse on the rotor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Iodobutane Deep Bed Adsorption Test Report

The Department of Energy (DOE) Nuclear Technology Research and Development (NTRD) Program Material Recovery and Waste Form Development (MRWFD) Campaign Off-gas Sigma Team has supported research and development on iodine control and iodine waste forms for the past several years. As a part of this on-going research, two deep-bed iodobutane adsorption tests have been performed with higher NO x levels. High (>1,000) iodine decontamination factors (DFs, the ratios of the inlet iodine concentrations divided by the outlet iodine concentrations, when the gas flowrate is constant) were achieved with both the silver aerogel and silver zeolite sorbents. The iodine adsorption mass transfer zone (the depth of the sorbent bed in which adsorption is occurring at any specific time) for these tests was estimated at 4 inches for both sorbents under the test conditions. Silver utilization for silver aerogel sorbent reached 41% (up to 12 g adsorbed iodine per 100 g silver aerogel sorbent), while silver utilization reached 43% (up to 6.8 g adsorbed iodine per 100 g silver zeolite sorbent). These values are generally consistent with results for prior methyl iodide adsorption tests. The results also indicate that, during iodine adsorption process, the organic iodide molecule decomposes so that the iodine can be adsorbed. Even when sorbent breakthrough is reached, the organic iodide molecule continues to decompose; and the unadsorbed iodine that passes through bed is no longer in the form of the original organic iodide; but in the form of iodine compounds that are soluble in NaOH solutions, such as HI or I 2 . This research and development has included iodine adsorption tests using a laboratory-scale test system containing segmented fixed beds of iodine adsorbents in series. Non-radioactive synthetic gas mixtures were blended from air, nitrogen, NO, NO 2 , water, and the target iodine compounds to represent dissolver off-gas (DOG) streams from used nuclear fuel aqueous reprocessing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RELAP5-3D Pre-test Prediction for High Temperature Test Facility Test PG-26

The RELAP5-3D computer code has been used to perform a pre-test prediction for Test PG-26 in the High Temperature Test Facility at Oregon State University. Test PG-26 will simulate a pressurized conduction cooldown transient following a trip of the primary coolant system gas circulator. The facility is initialized with a steady-state power of 700 kW and prototypic core inlet and outlet helium coolant temperatures of 259 and 687°C, respectively. Sensitivity calculations addressed the flow coastdown time, the reactor cavity cooling system flow rate and temperature, and decay power.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Global Value Chain and Manufacturing Analysis on Geothermal Power Plant Turbines

Currently, geothermal project developers customize the size of the power plant to fit the resource being developed. The turbine is designed and sized to optimize efficiency and resource utilization for electricity production; most often, other power plant components are then chosen to complement the turbine design. These custom turbine designs demand one-off manufacturing processes, which result in higher manufacturing setup costs, longer lead-times, and higher capital costs overall in comparison to larger-volume line manufacturing processes. In contrast, turbines produced in standard increments, manufactured in larger volumes, could result in lower costs per turbine. In this study, we developed a manufacturing cost model to identify requirements for equipment, facilities, raw materials, and labor. Then we used discounted cash flow (DCF) analysis to calculate the minimum sustainable price (MSP). We analyzed three different cases 1) 1 MWe geothermal ORC turboexpander 2) 5 MWe ORC turboexpander and 3) 20 MWe geothermal steam turbine, and calculated the cost of manufacturing the major components, such as the impellers/blades, shaft/rotor, nozzles, inlet guide lanes, disks, and casings. The results showed that MSP could highly vary between 893 /kW and 30 /kW based on turbine size, standardization and volume of manufacturing. The analysis also showed that the economy of scale applies both to the size of the turbine and the number manufactured in a single run. As an example, the unit price of a 5 MW standard design turbine could be 150 /W cheaper than the custom design. Sensitivity analysis indicated that these savings come largely from reduced labor costs for design and engineering and manufacturing setup. In addition to manufacturing cost savings, there is a delivery time saving up to 10 months, which could have a positive effect to construction financing operation time. Another advantage of these standard turbines is their adaptability to different geothermal systems by operating at off-design conditions. We also modeled off-design turbine efficiencies within the commercially-favorable operating range of a standard ORC compared to custom-designed ORC equipment. Than we used these performance calculations and power output capacities in a discounted cash flow (DCF) analysis of plant operations and financing, thereby creating representative techno economic models of a total geothermal power plant. I this scope we used NREL's System Advisor model (SAM) and performed DCF analysis of standard and custom design turbines using results from IPSEpro over range of temperatures of interest. In this scope 63 different off-design cases were analyzed. This helped us to answer the question; 'Can today's capital cost savings compensate the future revenue losses due to lower electricity generation?' The results showed that, the net capital cost savings for the modeled 5 MW case study may reach up to plus 1,298,672. Also, the difference between NPV of standard design and custom design turbine could reach up to 733,940. To sum up, when all the things mentioned above are taken into consideration, it can be said that, the standard turbines are competitive over a wide range of temperatures and flow rates and the give positive NPV differences for certain cases near their design point.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cold Box Testing

The objective of this document is to conduct and record heat transfer calculations for a Cold Test Box. The Cold Test Box is constructed of three layers of insulating foam with an inlet and outlet port that allows a spherical object housed inside the box to be temperature-controlled by closed-loop cold air convection from a Cincinnati Sub-Zero Thermal Cooling Unit (TCU).

42 ENGINEERING↗

Results of Magnesium in Rain Water Sampling

Lawrence Livermore National Laboratory (LLNL) is regulated under California's Industrial General Permit (IGP) under SIC code 4953 (Hazardous Waste Facilities). According to the IGP, facilities under this SIC code must sample for magnesium in their industrial stormwater runoff. In the 2015-2016 stormwater year, LLNL entered level 1 status for magnesium. In the 2016-2017 stormwater year, LLNL added filter inserts and filter rolls to storm-basin inlets but still exceeded the Numeric Action Level (NAL) and entered Level 2 status for magesium. LLNL's 2017 Level 2 Exceedance Response Action (ERA) technical report, demonstrated that the high magnesium levels are from natural processes occurring in the surrounding geology instead of anthropogenic or industrial activity. LLNL found the source of magnesium is caused from eroded minderal phases and likely dry deposition of air particulates (Esser, 2016). To further investigate the source of magnesium and to strengthen LLNL's conclusion that elevated magnesium concentrations are from natural sources, LLNL conducted sampling events to analyse the magnesium levels in direct rainfall.

54 ENVIRONMENTAL SCIENCES↗

An Uncertainty Quantification of the Computational Fluid Dynamics Solution to the Modeling of the Contact Point in a Wire-Wrapped Fuel Assembly

An uncertainty quantification and sensitivity analysis of the turbulent flow in a wire-wrapped pin bundle to the contact-point model and the inlet conditions is presented. Three geometries are considered in this work that are an infinitely large bundle (single subchannel with periodic boundary conditions in the stream-wisedirection), a 7-pin bundle and a 19-pin bundle. The response functions of this study are the friction factor, thevorticity and the mixing parameters. The results show that the friction factor is not sensitive to the contact-point model. The vorticity shows a strong dependency to the inclusion of prismatic layers near the wall boundaries. Results for the mixing parameters are inconclusive. A variance-based sensitivity analysis(Sobol indices) indicates that the influence of the contact-point model on the variance of the friction factor decreases when increasing the size of the bundle. Other response functions (vorticity and mixing parameters)show little sensitivity to the size of the bundle.

42 ENGINEERING↗

sCO 2 Cycle Analysis – Preliminary Results

This is a presentation on a '10 MWe sCO 2 Demo analysis'. The sCO 2 cycle modeled is a Recompression Brayton Cycle. A baseline cycle is base on a series of parameters that were assumed as reasonable from preliminary runs and know literature values. Sensitivities to key parameters were then made. These included pressure ratio, system pressure drop, minimum recuperator temperature approach., and turbine inlet temperature. The idea of cost surrogate variables is also introduced.

42 ENGINEERING↗

Techno-economic Evaluation of Utility-Scale Power Plants Based on the Indirect sCO 2 Brayton Cycle - Report

This report presents the results of a techno-economic analysis (TEA) of a coal-fired utility scale power plant based on the indirect supercritical carbon dioxide (sCO 2 ) Brayton cycle using an oxy-fired circulating fluidized bed (CFB). A baseline plant configuration was examined as well as three variations to the sCO 2 power cycle examining the impact of reheat (Rht), main compressor intercooling (IC), and a combination of reheat and main compressor intercooling (RhtIC). Each plant configuration was assessed at two turbine inlet temperatures of 620 °C and 760 °C.

20 FOSSIL-FUELED POWER PLANTS↗