Search NASA⌕ Search

SEARCH · Search NASA

Results for “LABORATORY EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

The Acoustic Emission signal acquired by the microphones placed in the CABRI test device along the fourteen last R.I.A. experiments: an example of reproducible research in nuclear science

The CABRI facility is an experimental nuclear reactor of the French Atomic Energy Commission. It is located at the Cadarache Research Centre in southern France and it is designed to act as a support to the French nuclear infrastructure. The purpose of the new testing programme termed, 'CABRI International Programme' (CIP) is to study the behaviour of PWR-type fuel rods at high burnup, equipped with an 'advanced' cladding, under Reactivity Initiated Accident (RIA) conditions (such as the scenario of a control rod ejection). Within the framework of this programme, piloted and funded by the French Institute of Nuclear Radioprotection and Safety (IRSN), ten tests are to be conducted with a frequency of two tests per year. The LPRE laboratory of the CEA which is in charge of the Preparation, realisation and breakdown of the test results studies the possibility to set up a new test analysis based on the processing of signals coming from sensors placed within the test equipment. During the experimental phase, the behaviour of the fuel element generates acoustic waves which can be detected by two microphones placed upstream and downstream of the test device. Studies showed the interest to realize temporal and spectral analyses on these signals by showing the existence of signatures which can be correlated with physical phenomena as the rod failure or the test shutdown (i.e. scram). The work presented in this article results from the will to consolidate these studies. Since the main phenomenon to be tracked is the fuel rod failure, the aim would be to highlight specific events which would have been precursors of the rod failure in order to use in the future these signals for further interpretation. Such an antecedent works resumption leads to a better understanding of the experimental needs and constitutes a good initial state to prepare the new very fast digital data acquisition systems. Although all the raw data are accessible in the form of text files, analyses and graphics representations were not straightforward to reproduce from the ancient studies since that, on one hand, people who were in charge of the original work left the laboratory and on the other hand because it is not easy when the time passes, even with our own work, to be able to remember the steps of data manipulations and the exact setup: - During the ancient experiments the use of analog data acquisition systems required to digitize tapes to be able to realize computer treatments. That had had for consequence to lose the initial dating. This one must be correctly edited to do temporal comparisons. - Analyses require functions for calculations whose parameters has to be well-known to reach the same results. We thus wished to manage our workflow in the idea that it can be easily reproducible on all the experiments. The object of the work presented in this article was to put in practice this strong bind between the data, treatments and generation of the document in order not to hesitate to do the iteration principle in action. We do not have to be afraid by the data driven analyses. According to the philosophy of the literate programming, the text of the technical document is woven with the computer code that produces all the printed output as tables, graphs for the study eliminating hence the unrealistic cut and paste. This difficulty is not specific to the nuclear domain. For many years, researchers have been worked out solutions to this mundane issue. And, presently, new technologies and high-level programming languages offer us actual answers. We will firstly present the tools applied in our laboratory to implement this workflow, then we will describe the global perception carried out to continue the study of the Acoustic Emission signals recorded by the two microphones during the fourteen last CABRI R.I.A. test.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data Sharing Report for the Quantification of Removable Activity in Various Surveillance and Maintenance Facilities at the Oak Ridge National Laboratory Oak Ridge TN

The U.S. Department of Energy (DOE) Oak Ridge Office of Environmental Management (OR-EM) requested that Oak Ridge Associated Universities (ORAU), working under the Oak Ridge Institute for Science and Education (ORISE) contract, provide technical and independent waste management planning support using American Recovery and Reinvestment Act (ARRA) funds. Specifically, DOE OR-EM requested that ORAU plan and implement a sampling and analysis campaign targeting potential removable radiological contamination that may be transferrable to future personal protective equipment (PPE) and contamination control materials—collectively referred to as PPE throughout the remainder of this report—used in certain URS|CH2M Oak Ridge, LLC (UCOR) Surveillance and Maintenance (S&M) Project facilities at the Oak Ridge National Laboratory (ORNL). Routine surveys in Bldgs. 3001, 3005, 3010, 3028, 3029, 3038, 3042, 3517, 4507, and 7500 continuously generate PPE. The waste is comprised of Tyvek coveralls, gloves, booties, Herculite, and other materials used to prevent worker exposure or the spread of contamination during routine maintenance and monitoring activities. This report describes the effort to collect and quantify removable activity that may be used by the ORNL S&M Project team to develop radiation instrumentation “screening criteria.” Material potentially containing removable activity was collected on smears, including both masselin large-area wipes (LAWs) and standard paper smears, and analyzed for site-related constituents (SRCs) in an analytical laboratory. The screening criteria, if approved, may be used to expedite waste disposition of relatively clean PPE. The ultimate objectives of this effort were to: 1) determine whether screening criteria can be developed for these facilities, and 2) provide process knowledge information for future site planners. The screening criteria, if calculated, must be formally approved by Federal Facility Agreement parties prior to use for ORNL S&M Project PPE disposal at the Environmental Management Waste Management Facility (EMWMF). ORAU executed the approved sampling and analysis plan (SAP) (DOE 2013) while closely coordinating with ORNL S&M Project personnel and using guidelines outlined in the Waste Handling Plan for Surveillance and Maintenance Activities at the Oak Ridge National Laboratory, DOE/OR/01-2565&D2 (WHP) (DOE 2012). WHP guidelines were followed because the PPE waste targeted by this SAP is consistent with that addressed under the approved Waste Lot (WL) 108.1 profile for disposal at EMWMF—this PPE is a “future waste stream” as defined in the WHP. The SAP presents sampling strategy and methodology, sample selection guidelines, and analytical guidelines and requirements necessary for characterizing future ORNL S&M Project PPE waste. This report presents a review of the sample and analysis methods including data quality objectives (DQOs), required deviations from the original design, summary of field activities, radiation measurement data, analytical laboratory results, a brief presentation of results, and process knowledge summaries.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energetics and Dynamics of Electron Transfer and Proton Transfer in Dissociation of Metal III (salen)-Peptide Complexes in the Gas Phase

Time- and collision energy-resolved surface-induced dissociation (SID) of ternary complexes of CoIII(salen)+, FeIII(salen)+, and MnIII(salen)+ with several angiotensin peptide analogs was studied using a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) specially equipped to perform SID experiments. Time-resolved fragmentation efficiency curves (TFECs) were modeled using an RRKM-based approach developed in our laboratory. The approach utilizes a very flexible analytical expression for the internal energy deposition function that is capable of reproducing both single-collision and multiple-collision activation in the gas phase and excitation by collisions with a surface. The energetics and dynamics of competing dissociation pathways obtained from the modeling provides important insight on the competition between proton transfer, electron transfer, loss of neutral peptide ligand, and other processes that determine gas-phase fragmentation of these model systems. Similar fragmentation behavior was obtained for various CoIII(salen)-peptide systems of different angiotensin analogs. In contrast, dissociation pathways and relative stabilities of the complexes changed dramatically when cobalt was replaced with trivalent iron or manganese. We demonstrate that the electron transfer efficiency is correlated with redox properties of the metalIII(salen) complexes (Co > Fe > Mn), while differences in the types of fragments formed from the complexes reflect differences in the modes of binding between the metal-salen complex and the peptide ligand. RRKM modeling of time- and collision energy-resolved SID data suggests that the competition between proton transfer and electron transfer during dissociation of CoIII(salen)-peptide complexes is mainly determined by differences in entropy effects while the energetics of these two pathways are very similar.

Environmental Molecular Sciences Laboratory↗

Response Surfaces for Key Controlled Variables in a Hybrid Solid Oxide Fuel Cell/Gas Turbine System

Hybrid generation systems have been extensively modeled as a first step toward the development of automatic controls for the system. In most cases, it is impossible to validate mathematical models against real hardware because only a handful of hardware systems exist in the world. Data taken from the existing hardware has demonstrated significant nonlinearity, complex coupling between controlled variables, and sometimes non-intuitive behavior. This work exploits the capability of the HyPer hardware test bed at the National Energy Technology Laboratory (NETL) to generate data from a real recuperated gas turbine coupled with hardware simulations of a fuel cell cathode and appropriate ancillary equipment. Prior work has characterized the system only over a limited range of its operating envelope, due to the inability to manipulate multiple control inputs simultaneously. The work presented here fills the gaps using data from a 34 factorial experiment to generate quasi-continuous response surfaces describing the operating state space of the HyPer system. Polynomial correlation functions have been fitted to the data with excellent agreement. Relationships between the control inputs and critical state variables such as cathode mass flow, cathode temperature, turbine inlet and exhaust temperatures and other key system parameters are presented.

30 DIRECT ENERGY CONVERSION↗

Automated Measurement and Signaling Systems for the Transactional Network

The Transactional Network Project is a multi-lab activity funded by the US Department of Energy's Building Technologies Office. The project team included staff from Lawrence Berkeley National Laboratory, Pacific Northwest National Laboratory and Oak Ridge National Laboratory. The team designed, prototyped and tested a transactional network (TN) platform to support energy, operational and financial transactions between any networked entities (equipment, organizations, buildings, grid, etc.). PNNL was responsible for the development of the TN platform, with agents for this platform developed by each of the three labs. LBNL contributed applications to measure the whole-building electric load response to various changes in building operations, particularly energy efficiency improvements and demand response events. We also provide a demand response signaling agent and an agent for cost savings analysis. LBNL and PNNL demonstrated actual transactions between packaged rooftop units and the electric grid using the platform and selected agents. This document describes the agents and applications developed by the LBNL team, and associated tests of the applications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Smart Grid Enabled EVSE

The combined team of GE Global Research, Federal Express, National Renewable Energy Laboratory, and Consolidated Edison has successfully achieved the established goals contained within the Department of Energy’s Smart Grid Capable Electric Vehicle Supply Equipment funding opportunity. The final program product, shown charging two vehicles in Figure 1, reduces by nearly 50% the total installed system cost of the electric vehicle supply equipment (EVSE) as well as enabling a host of new Smart Grid enabled features. These include bi-directional communications, load control, utility message exchange and transaction management information. Using the new charging system, Utilities or energy service providers will now be able to monitor transportation related electrical loads on their distribution networks, send load control commands or preferences to individual systems, and then see measured responses. Installation owners will be able to authorize usage of the stations, monitor operations, and optimally control their electricity consumption. These features and cost reductions have been developed through a total system design solution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fiscal Year 2021 Filtration of Hanford Tank 241-AP-107 Supernatant Samples Obtained at Prototypic Tank Level and Filtered at 16 °C

Bench-scale filtration testing of 8.5 liters of supernatant from Hanford waste tank 241-AP-107, chilled to 16 °C, was conducted using a backpulse dead-end filter (BDEF) filtration system equipped with a feed vessel and a Mott inline filter Model 6610 (Media Grade 5) in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. This was done to assess the impact of a lower sampling location within the tank as well the lowered filtration temperature on supernatant stability and fouling. The as-received samples were transferred to 1.5-liter poly bottles and held at 16 °C for approximately 1 week prior to filtration. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft 2 to match the prototypic operation of the TSCR system. During the initial period of filtration, the differential pressure required to effect filtration at 0.065 gpm/ft 2 increased until it reached 2 psid [the Tank Side Cesium Removal (TSCR) action limit] at 26 hours. After this, the filter was backpulsed to dislodge accumulated solids and reduce this pressure differential. An additional eight backpulses were conducted during the initial filtration period; each time, the target pressure was reached sooner than during the previous interval. Volume filtered decreased from 0.9 to 0.03 m 3 /m 2 over the course of 14 processing hours. After the ninth backpulse, the backpulse frequency had become unsustainable, and it was decided to perform an extensive filter cleaning. The filter was cleaned by draining the chilled AP-107 feed into chilled holding containers, introducing 0.1 M NaOH into the feed vessel, and recirculating the NaOH through the system for 20 minutes before allowing the system to soak for 2 hours without temperature control. A measurable decrease in filter resistance during this recirculation indicated that the 0.1 M NaOH was likely dissolving some of the solids that had deposited on the filter. Post cleaning, the filter resistance was effectively restored to initial conditions as the initial transmembrane pressure was restored to original levels. However, resumed processing of the AP-107 feed at 16 °C continued to result in an increased rate of filter resistance. An additional five backpulses were conducted (four during feed processing, one during subsequent cleaning) before the conclusion of the test. Solids concentrated from the backpulse solutions displayed sodium oxalate-type phases, Al-oxides and sodium Al-oxides/carbonates, iron oxides, and Ca-bearing phases (calcite). The scanning electron microscopy analyses also revealed a large distribution of particles, with some particles, notably sodium phosphate dodecahydrate, having diameters close to 0.5 mm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fiscal Year 2022. Filtration of Hanford Tank 241-AP-101 Supernatant at 16 °C

Bench-scale filtration testing of ~9 liters of supernatant from Hanford waste tank 241-AP-101, chilled to 16 °C, was conducted using a backpulse dead-end filter (BDEF) filtration system equipped with a feed vessel and a Mott inline filter Model 6610 (Media Grade 5) in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. This was done to assess the performance of the anticipated third feed to the Tank Side Cesium Removal (TSCR) system. The as-received samples were diluted to the target sodium concentration and transferred to 1.5-liter polyethylene bottles and held at 16 °C for approximately 1 week prior to filtration. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft 2 to match the prototypic operation of the TSCR system. During filtration, the differential pressure required to effect filtration at 0.065 gpm/ft 2 increased little over the filtration campaign and never reached 2 psid (the TSCR action limit). This indicates that the TSCR filter should perform well when processing AP-101 supernatant. After completing filtration of the AP-101 feed, the filter was cleaned. Solids concentrated from the backpulse solutions displayed sodium nitrate-type phases, aluminum and silicon phases reported as cancrinite or nitrate-cancrinite, a mixed chromium-aluminum oxide, iron oxides, and Ca-bearing phases (calcite). Scanning electron microscopy analyses showed that the average particle size was 0.5 micron.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hot Cell Manipulator Inventory and Recommendations

During the spring of 2021 repeated manipulator failures in the hot cells of Building 7920 contributed to significant delays in Californium-252 ( 252 Cf) mission execution and loss of rapidly decaying 252Cf product. At the same time, funds became available in the 252 Cf program budget for equipment purchases and upgrades. Accordingly, the 252 Cf program manager requested (1) an inventory of the manipulators used in six Oak Ridge National Laboratory (ORNL) buildings (7920, 7930, 4501, 3047, 3025E, and 3525), (2) an inventory of spare manipulators, and (3) a recommendation on whether to invest 252 Cf funds to purchase additional or upgraded manipulators.

07 ISOTOPE AND RADIATION SOURCES↗

Operational and Mission Highlights A Monthly Summary of Top Achievements: September 2022

Associate Laboratory Director for Plutonium Infrastructure Mark Anthony and a procurement team visited three glovebox fabricators the week of Aug. 23, 2022, to discuss equipment procurement options and assess the vendors’ production capability, factory conditions, and safety records. The team determined that all three fabricators can produce complex gloveboxes and meet Nuclear Quality Assurance-1 standards.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

EV Champion Training Webinar 1: ZEV and EV Charging Fundamentals [Slides]

The Electric Vehicle (EV) Champion Training Series, hosted by the National Renewable Energy Laboratory (NREL), is tailored for fleet managers, facility managers, and other stakeholders involved in the deployment of EVs and charging stations. This series equips participants with the skills and knowledge necessary to become subject matter experts in EV implementation. This is the first training in a four-part series and serves as an introductory training. This training covers fundamental topics such as EV and charging technology, utility basics, and financial considerations for EVs. Additionally, this session introduces the Federal Fleet ZEV Ready Center framework, a one-stop location for federal fleet electrification resources. Participants will gain a solid foundation to support the effective deployment and management of EVs and their infrastructure. Visit the Federal Fleet ZEV Ready Center website to learn more about the ZEV Ready Center process. EV Champion Training Webinar 1: ZEV and EV Charging Fundamentals will enable attendees to: Identify EV and EV charging technology fundamentals; Recognize EV market and GSA Schedule options; Identify utility basics, incentives, and rates as they relate to EV charging; and Identify methods to calculate life cycle costs for EVs and gasoline vehicles.

30 DIRECT ENERGY CONVERSION↗

A laser velocimeter system for large-scale aerodynamic testing

A unique laser velocimeter was developed that is capable of sensing two orthogonal velocity components from a variable remote distance of 2.6 to 10 m for use in the 40- by 80-Foot and 80- by 120-Foot Wind Tunnels and the Outdoor Aerodynamic Research Facility at Ames Research Center. The system hardware, positioning instrumentation, and data acquisition equipment are described in detail; system capabilities and limitations are discussed; and expressions for systematic and statistical accuracy are developed. Direct and coupled laboratory measurements taken with the system are compared with measurements taken with a laser velocimeter of higher spatial resolution, and sample data taken in the open circuit exhaust flow of a 1/50-scale model of the 80- by 120-Foot Wind Tunnel are presented.

Reinath, M. S.↗

A laser velocimeter system for the Ames 40- by 80-foot and 80by 120-foot wind tunnels

A unique laser velocimeter has been developed that is capable of sensing two orthogonal velocity components from a variable remote distance of 2.6 to 10 m for use in the Ames 40- by 80-Foot and 80- by 120-Foot wind tunnels, as well as in the Ames Outdoor Aerodynamic Research Facility. The system hardware, positioning instrumentation, and data acquisition equipment are described in detail. System capabilities and limitations are discussed, and expressions for systematic and statistical accuracy are developed. Direct and coupled laboratory measurements of a turbulent swirling flow are compared with measurements taken with a laser velocimeter of higher spatial resolution. Sample measurements taken in the open-circuit exhaust flow of the 80- by 120-Foot Wind Tunnel 1/50-scale model are presented.

Reinath, M. S.↗

Centimeter-level relative positioning with GPS

Although the Global Positioning System (GPS) was designed primarily for real-time navigation and positioning applications at the decameter level of accuracy, the GPS has been used to determine all three relative position coordinates of fixed points with centimeter-level accuracy, when the distance between the points has been of the order of 10 km. For intersite distances less than 1 km the uncertainty is about 3 mm, and for distances greater than 10 km the uncertainty in each coordinate is about 1-2 ppm of the distance. These results have been obtained with commercially available production equipment (Macrometer model V-1000 interferometric surveyors) operated by regular surveying personnel under real field conditions, not just by university scientists under ideal laboratory conditions. Techniques that promise to reduce the uncertainty to 0.1 ppm for distances greater than 10 km are being developed.

Counselman, C. C., III↗

Study of Plasma Motor Generator (PMG) tether system for orbit reboost

Detailed designs were produced for a 2 kW plasma motor generator tether system based largely on existing hardware and hardware designs. Specifically, the hollow cathode design and electronics are derived from ion propulsion equipment. A prototype tether was constructed and will be tested for deployment, strength, resistance to breakage and abrasion and electrical properties. In addition, laboratory development models of the electronics will be used to operate two plasma motor generator hollow cathode assemblies with this tether to verify electrical performance parameters for the complete system. Results show that a low cost demonstration of a plasma motor generator tether system appears to be feasible by the middle of the 1990s.

Source record↗

GENESIS 2: Advanced lunar outpost

Advanced, second-generation lunar habitats for astronauts and mission specialists working on the Moon are investigated. The work was based on design constraints set forth in previous publications. Design recommendations are based on environmental response to the lunar environment, habitability, safety, near-term technology, replaceability and modularity, and suitability for NASA lunar research missions in the early 21st century. Scientists, engineers, and architects from NASA/JSC, Wisconsin aeronautical industry, and area universities gave technical input and offered critiques at design reviews throughout the process. The recommended design uses a lunar lava tube, with construction using a combination of Space Station Freedom-derived modules and lightweight Kevlar-laminate inflatables. The outpost includes research laboratories and biotron, crew quarters and support facility, mission control, health maintenance facility, and related areas for functional and psychological requirements. Furniture, specialized equipment, and lighting are included in the design analysis.

Moore, Gary T.↗

Compound Separation

Jet Propulsion Laboratory developed a new one-step liquid-liquid extraction technique which cuts processing time, reduces costs and eliminates much of the equipment required. Technique employs disposable extraction columns, originally developed as an aid to the Los Angeles Police Department, which allow more rapid detection of drugs as part of the department's drug abuse program. Applications include medical treatment, pharmaceutical preparation and forensic chemistry. NASA waived title to Caltech, and Analytichem International is producing Extubes under Caltech license.

Source record↗