Prevention of a wrong-location misadministration through the use of an intradepartmental incident learning system

Purpose: A series of examples are presented in which potential errors in the delivery of radiation therapy were prevented through use of incident learning. These examples underscore the value of reporting near miss incidents. Methods: Using a departmental incident learning system, eight incidents were noted over a two-year period in which fields were treated 'out-of-sequence,' that is, fields from a boost phase were treated, while the patient was still in the initial phase of treatment. As a result, an error-prevention policy was instituted in which radiation treatment fields are 'hidden' within the oncology information system (OIS) when they are not in current use. In this way, fields are only available to be treated in the intended sequence and, importantly, old fields cannot be activated at the linear accelerator control console. Results: No out-of-sequence treatments have been reported in more than two years since the policy change. Furthermore, at least three near-miss incidents were detected and corrected as a result of the policy change. In the first two, the policy operated as intended to directly prevent an error in field scheduling. In the third near-miss, the policy operated 'off target' to prevent a type of error scenario that it was not directly intended to prevent. In this incident, an incorrect digitally reconstructed radiograph (DRR) was scheduled in the OIS for a patient receiving lung cancer treatment. The incorrect DRR had an isocenter which was misplaced by approximately two centimeters. The error was a result of a field from an old plan being scheduled instead of the intended new plan. As a result of the policy described above, the DRR field could not be activated for treatment however and the error was discovered and corrected. Other quality control barriers in place would have been unlikely to have detected this error. Conclusions: In these examples, a policy was adopted based on incident learning, which prevented several errors, at least one of which was potentially severe. These examples underscore the need for a rigorous, systematic incident learning process within each clinic. The experiences reported in this technical note demonstrate the value of near-miss incident reporting to improve patient safety.

60 APPLIED LIFE SCIENCES↗

SU-E-T-644: Evaluation of Angular Dependence Correction for 2D Array Detector Using for Quality Assurance of Volumetric Modulated Arc Therapy

Purpose: To evaluate the angular dependence correction for Matrix Evolution 2D array detector in quality assurance of volumetric modulated arc therapy(VMAT). Methods: Total ten patients comprising of different sites were planned for VMAT and taken for the study. Each plan was exposed on Matrix Evolution 2D array detector with Omnipro IMRT software based on the following three different methods using 6MV photon beams from Elekta Synergy linear accelerator. First method, VMAT plan was delivered on Matrix Evolution detector as it gantry mounted with dedicated holder with build-up of 2.3cm. Second, the VMAT plan was delivered with the static gantry angle on to the table mounted setup. Third, the VMAT plan was delivered with actual gantry angle on Matrix Evolution detector fixed in Multicube phantom with gantry angle sensor and angular dependence correction were applied to quantify the plan quality. For all these methods, the corresponding QA plans were generated in TPS and the dose verification was done for both point and 2D fluence analysis with pass criteria of 3% dose difference and 3mm distance to agreement. Results: The measured point dose variation for the first method was observed as 1.58±0.6% of mean and SD with TPS calculated. For second and third method, the mean and standard deviation(SD) was observed as 1.67±0.7% and 1.85±0.8% respectively. The 2D fluence analysis of measured and TPS calculated has the mean and SD of 97.9±1.1%, 97.88±1.2% and 97.55±1.3% for first, second and third methods respectively. The calculated two-tailed Pvalue for point dose and 2D fluence analysis shows the insignificance with values of 0.9316 and 0.9015 respectively, among the different methods of QA. Conclusion: The qualitative evaluation of angular dependence correction for Matrix Evolution 2D array detector shows its competency in accuracy of quality assurance measurement of composite dose distribution of volumetric modulated arc therapy.

07 ISOTOPE AND RADIATION SOURCES↗

SU-D-BRD-07: Evaluation of the Effectiveness of Statistical Process Control Methods to Detect Systematic Errors For Routine Electron Energy Verification

Purpose: To evaluate the ability of statistical process control methods to detect systematic errors when using a two dimensional (2D) detector array for routine electron beam energy verification. Methods: Electron beam energy constancy was measured using an aluminum wedge and a 2D diode array on four linear accelerators. Process control limits were established. Measurements were recorded in control charts and compared with both calculated process control limits and TG-142 recommended specification limits. The data was tested for normality, process capability and process acceptability. Additional measurements were recorded while systematic errors were intentionally introduced. Systematic errors included shifts in the alignment of the wedge, incorrect orientation of the wedge, and incorrect array calibration. Results: Control limits calculated for each beam were smaller than the recommended specification limits. Process capability and process acceptability ratios were greater than one in all cases. All data was normally distributed. Shifts in the alignment of the wedge were most apparent for low energies. The smallest shift (0.5 mm) was detectable using process control limits in some cases, while the largest shift (2 mm) was detectable using specification limits in only one case. The wedge orientation tested did not affect the measurements as this did not affect the thickness of aluminum over the detectors of interest. Array calibration dependence varied with energy and selected array calibration. 6 MeV was the least sensitive to array calibration selection while 16 MeV was the most sensitive. Conclusion: Statistical process control methods demonstrated that the data distribution was normally distributed, the process was capable of meeting specifications, and that the process was centered within the specification limits. Though not all systematic errors were distinguishable from random errors, process control limits increased the ability to detect systematic errors using routine measurement of electron beam energy constancy.

07 ISOTOPE AND RADIATION SOURCES↗

Megavoltage cone beam CT near surface dose measurements: potential implications for breast radiotherapy

Purpose: Cone beam computed tomography (CBCT) is fast becoming standard on modern linear accelerators. CBCT increases the dose to regions within and outside the treatment field, potentially increasing secondary cancer induction and toxicity. This study quantified megavoltage (MV) CBCT skin dose and compared it to skin dose delivered during standard tangential breast radiotherapy.Method: Dosimetry was performed both in- and out-of-field using thermoluminescent dosimeters (TLDs) and a metal-oxide-semiconductor-field-effect-transistor (MOSFET) detector specifically designed for skin dosimetry; these were placed superficially on a female anthropomorphic phantom. Results: The skin dose from a single treatment fraction ranged from 0.5 to 1.4 Gy on the ipsilateral breast, 0.031-0.18 Gy on the contralateral breast, and 0-0.02 Gy in the head and pelvic region. An 8 MU MV CBCT delivered a skin dose that ranged from 0.02 to 0.05 Gy in the chest region and was less than 0.01 Gy in the head and pelvis regions. One MV CBCT per fraction was found to increase the out-of-field skin dose from both the CBCT and the treatment fields by approximately 20%. The imaging dose as a percentage of treatment doses in the ipsilateral breast region was 3% for both dosimeters.Conclusion: Imaging increases the skin dose to regions outside the treatment field particularly regions immediately adjacent the target volume. This small extra dose to the breasts should be considered when developing clinical protocols and assessing dose for clinical trials.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-578: Characterization of Vidar DosimetryPro Advantage RED Scanner with Application to SBRT and SRS QA

Purpose: To use Gafchromic EBT3 film to quantify key dosimetric characteristics of the Vidar DosimetryPro Advantage RED film scanner for use in SBRT/SRS QA, by analyzing scanner uniformity and dose sensitivity. Method: Gafchromic EBT3 film was used in this study. Films were irradiated using 6MV FFF and 10MV FFF beams from a Varian Edge linear accelerator, with setup of 100cm SAD at depth 5 cm. Nine doses were delivered per film, with calibration dose ranges of 1–10 Gy and 3–24 Gy for 6MV FFF, and 3–27 Gy for 10MV FFF. Films were scanned with the long side of the film parallel to the detector array. Dose calibration curves were fitted to a 3rd degree polynomial. The derivative of a calibration curve was taken to determine the scanner’s sensitivity per dose delivered (OD/Gy). Scanner non-uniformity was calculated in 2 dimensions by taking the mean of standard deviation in each row and column. Absolute dose SRS/SBRT Gamma analyses were performed with passing criteria of 3% and 1mm DTA. For comparison, Gamma analyses were also performed using an Epson Expression 10000 XL. Results: Uniformity for the Vidar scanner was 0.37% +/− 0.03% in the perpendicular to scan direction and 0.67% +/− 0.05% in the parallel to scan direction, with an overall uniformity of 0.52% +/− 0.03%. Epson red channel uniformity was 0.85% +/− 0.05% and 0.88% +/− 0.08% for the green channel. The Vidar average dose sensitivity from 1–10 Gy was 0.112 OD/Gy and 0.061 OD/Gy for 3–24 Gy. SBRT/SRS Gamma pass rates were 97.8 +/− 1.4 for Vidar and 97.5 +/− 1.4 for Epson. Conclusion: The Vidar scanner has 41% less non-uniformity compared to Epson XL10000 green channel. The dose sensitivity is 2–3 time greater for the Vidar scanner compared to the Epson in the SRS/SBRT dose range of 5–24 Gy.

60 APPLIED LIFE SCIENCES↗

Verification of dosimetric accuracy on the TrueBeam STx: Rounded leaf effect of the high definition MLC

Purpose: The dosimetric leaf gap (DLG) in the Varian Eclipse treatment planning system is determined during commissioning and is used to model the effect of the rounded leaf-end of the multileaf collimator (MLC). This parameter attempts to model the physical difference between the radiation and light field and account for inherent leakage between leaf tips. With the increased use of single fraction high dose treatments requiring larger monitor units comes an enhanced concern in the accuracy of leakage calculations, as it accounts for much of the patient dose. This study serves to verify the dosimetric accuracy of the algorithm used to model the rounded leaf effect for the TrueBeam STx, and describes a methodology for determining best-practice parameter values, given the novel capabilities of the linear accelerator such as flattening filter free (FFF) treatments and a high definition MLC (HDMLC). Methods: During commissioning, the nominal MLC position was verified and the DLG parameter was determined using MLC-defined field sizes and moving gap tests, as is common in clinical testing. Treatment plans were created, and the DLG was optimized to achieve less than 1% difference between measured and calculated dose. The DLG value found was tested on treatment plans for all energies (6 MV, 10 MV, 15 MV, 6 MV FFF, 10 MV FFF) and modalities (3D conventional, IMRT, conformal arc, VMAT) available on the TrueBeam STx. Results: The DLG parameter found during the initial MLC testing did not match the leaf gap modeling parameter that provided the most accurate dose delivery in clinical treatment plans. Using the physical leaf gap size as the DLG for the HDMLC can lead to 5% differences in measured and calculated doses. Conclusions: Separate optimization of the DLG parameter using end-to-end tests must be performed to ensure dosimetric accuracy in the modeling of the rounded leaf ends for the Eclipse treatment planning system. The difference in leaf gap modeling versus physical leaf gap dimensions is more pronounced in the more recent versions of Eclipse for both the HDMLC and the Millennium MLC. Once properly commissioned and tested using a methodology based on treatment plan verification, Eclipse is able to accurately model radiation dose delivered for SBRT treatments using the TrueBeam STx.

60 APPLIED LIFE SCIENCES↗

SU-E-T-211: Induced Release of Nanocarrier Encapsulated Chemotherapeutic Drugs Using Proton Radiotherapy Beams

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for S and S IMRT based in the algorithm proposed by Kung et.al. Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS and S and S IMRT modality. A 6MV photon beam produced by a Primus linear accelerator equipped with an Optifocus MLC was used. TPS dose calculation algorithms were pencil beam and Monte Carlo. 230 IMRT treatments plans were selected for the study. The software was written under MALTLAB environment. Treatment plans were imported by the software using RTP format. Field fluences were reconstructed adding all segments.The algorithm implemented in the software calculates the dose at a reference point as the sum of primary and scatter dose. The primary dose is obtained by masking the fluence map with a circle of radius 1cm. The scatter dose is obtained through a shaped ring mask around the previous circle with a thickness of 0.5cm; the rings are increased one after another with constant thickness until cover the entire map of influence. The dosimetric parameters Sc, Sp and TPR vary depending on radio, the transmission effect of the MLC, inverse square law and dose profile are used for the calculation. Results: The average difference between measured and independent calculated dose was 0.4% ± 2.2% [−6.8%, 6.4%]. For 91% of the studied plans the difference was less than 3%. The difference between the measured and TPS dose with pencilbeam algorithm was 2.6% ± 1.41% [−2.0%, 5.6%] and Monte Carlo algorithm was 0.4% ± 1.5% [−4.9%, 3.7%]. The differences obtained are comparable to that obtained with the ionization chamber and TPS. Conclusion: The developed software is suitable for use in S and S IMRT dose calculation. This application is open and can be downloading under request.

60 APPLIED LIFE SCIENCES↗

SU-E-T-115: Analysis of Patient Specific QA for VMAT by Disease Site and Planning-Delivery System Using the ScandiDos Delta4 Phantom

Purpose: To evaluate patient specific quality assurance (PSQA) for the delivery of volumetric modulated arc therapy (VMAT) by disease site. To compare planning-delivery system (PDS) PSQA pass rates in a dual vendor institution. Methods: PSQA is performed for VMAT plans using a ScandiDos Delta4 phantom. Verification plans are calculated using Varian Eclipse and Elekta Monaco treatment planning systems (TPS) for patients treated using Varian Truebeam and Elekta linear accelerators respectively. Individual arcs are delivered to the Delta4 phantoms and assessed using the gamma index pass criterion(3% Dose Deviation(DD%), 3mm Distance to Agreement(DTA),10% dose threshold and 90% gamma index). Results: A total of 287 VMAT plans and 680 arcs were analyzed. The passing rates for VMAT QA plans were 95% and 98% for head/neck and pelvis/prostate plans respectively, and 100% for chest/abdomen, spine, lung Stereotactic Body Radiotherapy (SBRT) and Stereotactic Radiosurgery(SRS) plans. Average gamma indices were: (99 ± 2) % for pelvis/prostate, chest/abdomen and lung SBRT plans, (97 ± 4) % for head and neck plans and (98 ± 3) % for spine plans. The average DD% and DTA pass rates ranged from 82% to 90% and 98% to 99% respectively for plans in different disease sites. Paired t-test analysis (two tails) indicated no significant differences in the gamma indices between plans delivered using different PDS; the P values were: 0.08, 0.45, and 0.94 for lung SBRT, head/neck and pelvis/prostate plans respectively. The statistical power for comparing PDS in different disease sites with an alpha of 0.05 is 1. Conclusion: The Gamma indices based on 3% DD%, 3 mm DTA and 10% dose threshold for the VMAT QA plans in all disease sites were well above 90%, suggesting the possibility of using a more stringent PSQA criterion. No significant differences were observed in the QA of VMAT plans delivered using different PDS.

60 APPLIED LIFE SCIENCES↗

SU-E-J-167: Improvement of Time-Ordered Four Dimensional Cone-Beam CT; Image Mosaicing with Real and Virtual Projections

Purpose: In the previous study, we developed time-ordered fourdimensional (4D) cone-beam CT (CBCT) technique to visualize nonperiodic organ motion, such as peristaltic motion of gastrointestinal organs and adjacent area, using half-scan reconstruction method. One important obstacle was that truncation of projection was caused by asymmetric location of flat-panel detector (FPD) in order to cover whole abdomen or pelvis in one rotation. In this study, we propose image mosaicing to extend projection data to make possible to reconstruct full field-of-view (FOV) image using half-scan reconstruction. Methods: The projections of prostate cancer patients were acquired using the X-ray Volume Imaging system (XVI, version 4.5) on Synergy linear accelerator system (Elekta, UK). The XVI system has three options of FOV, S, M and L, and M FOV was chosen for pelvic CBCT acquisition, with a FPD panel 11.5 cm offset. The method to produce extended projections consists of three main steps: First, normal three-dimensional (3D) reconstruction which contains whole pelvis was implemented using real projections. Second, virtual projections were produced by reprojection process of the reconstructed 3D image. Third, real and virtual projections in each angle were combined into one extended mosaic projection. Then, 4D CBCT images were reconstructed using our inhouse reconstruction software based on Feldkamp, Davis and Kress algorithm. The angular range of each reconstruction phase in the 4D reconstruction was 180 degrees, and the range moved as time progressed. Results: Projection data were successfully extended without discontinuous boundary between real and virtual projections. Using mosaic projections, 4D CBCT image sets were reconstructed without artifacts caused by the truncation, and thus, whole pelvis was clearly visible. Conclusion: The present method provides extended projections which contain whole pelvis. The presented reconstruction method also enables time-ordered 4D CBCT reconstruction of organs with non-periodic motion with full FOV without projection-truncation artifacts. This work was partly supported by the JSPS Core-to-Core Program(No. 23003). This work was partly supported by JSPS KAKENHI 24234567.

60 APPLIED LIFE SCIENCES↗

Sci—Thur PM: Imaging — 03: A novel Čerenkov detector based on air-spaced light guiding taper for megavoltage x-ray imaging

Electronic Portal Imaging Devices (EPIDs) have been used in radiation therapy and are still needed on linear accelerators (Linacs) equipped with kilovoltage cone beam CT (kV-CBCT) or MRI systems. Recently a new concept of a high quantum efficiency (QE) Čerenkov Portal Imaging Device (CPID) for MV x-ray imaging in radiation therapy was introduced. It relies on Čerenkov effect for x-ray detection. The proposed design consisted of a matrix of optical fibres aligned with the incident x-rays and coupled to an active matrix flat panel imager (AMFPI) for image readout. A weakness of such design is that too few Čerenkov light photons reach the AMFPI for each incident x-ray and an AMFPI with an avalanche gain is required. In this work we propose to replace the optical fibers in the CPID with light guides without a cladding layer that are suspended in air. The air between the light guides takes on the role of the cladding layer found in a regular optical fiber. Since air has a significantly lower refractive index, a much superior light collection efficiency is achieved. Our Monte Carlo studies have shown that the modified new CPID has a QE more than an order of magnitude greater than that of current clinical systems and yet a spatial resolution similar to that of current flat-panel based EPIDs. Furthermore it has been demonstrated that the new CPID does not require an avalanche gain in the AMFPI and is quantum noise limited at dose levels corresponding to a single Linac pulse.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A diamond target for megavoltage cone-beam CT

Purpose: To determine the properties of a megavoltage cone-beam CT system using the unflattened beam from a sintered diamond target at 4 and 6 MV. Methods: A sintered diamond target was used in place of a graphite target as part of an imaging beam line (an unflattened beam from a graphite target) installed on a linear accelerator. The diamond target, with a greater density than the graphite target, permitted imaging at the lower beam energy (4 MV) required with the graphite target and the higher beam energy (6 MV) conventionally used with the tungsten/stainless steel target and stainless steel flattening filter. Images of phantoms and patients were acquired using the different beam lines and compared. The beam spectra and dose distributions were determined using Monte Carlo simulation. Results: The diamond target allowed use of the same beam energy as for treatment, simplifying commissioning and quality assurance. Images acquired with the diamond target at 4 MV were similar to those obtained with the graphite target at 4 MV. The slight reduction in low energy photons due to the higher-Z sintering material in the diamond target had minimal effect on image quality. Images acquired at 6 MV with the diamond target showed a small decrease in contrast-to-noise ratio, resulting from a decrease in the fraction of photons in the beam in the energy range to which the detector is most sensitive. Conclusions: The diamond target provides images of a similar quality to the graphite target. Diamond allows use of the higher beam energy conventionally used for treatment, provides a higher dose rate for the same beam current, and potentially simplifies installation and maintenance of the beam line.

61 RADIATION PROTECTION AND DOSIMETRY↗

A novel off-axis scanning method for an enlarged ellipse cone-beam computed tomography field of view

Purpose: Current on-board imaging systems commonly used by modern linear accelerators (LINACs) have a limited field of view (FOV) for a cone-beam CT (CBCT) scan, which is typically less than 50 cm. Consequently, truncation artifacts often occur for large patients. The goal of this work is to investigate a novel method to increase the FOV for current on-board CBCT systems. Methods: When a large patient is scanned with CBCT, any region outside the FOV is only partially sampled within a short range of projection angles, and at other angles no x-ray beams may pass through that region. To increase the sampling rate for the region outside the FOV, we have designed a new source trajectory by shifting the center of rotation during a CBCT scan. This resulted in a reduced sampling rate at the central area and increased sampling rate at the edges. The tradeoff led to a more balanced sampling for an enlarged FOV. An iterative algorithm was also developed to reconstruct the CT image under the new sampling scheme using a compressed sensing technique. Results: The method was validated by numerical simulations mimicking a Varian Trilogy CBCT system, and it was found that artifact-free images could be obtained with the FOV as large as 80 cm. Conclusions: The new CT scanning trajectory can be easily realized under current clinical setup with little modification of the control system, and this can be useful for treating obese patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-465: Implementation of An Automated Collision Detection Program Using Open Source Software for the Pinnacle Treatment Planning System

Purpose: Potential collisions between the gantry head and the patient or table assembly are difficult to detect in most treatment planning systems. We have developed and implemented a novel software package for the representation of potential gantry collisions with the couch assembly at the time of treatment planning. Methods: Physical dimensions of the Varian Edge linear accelerator treatment head were measured and reproduced using the Visual Python display package. A script was developed for the Pinnacle treatment planning system to generate a file with the relevant couch, gantry, and isocenter positions for each beam in a planning trial. A python program was developed to parse the information from the TPS and produce a representative model of the couch/gantry system. Using the model and the Visual Python libraries, a rendering window is generated for each beam that allows the planner to evaluate the possibility of a collision. Results: Comparison against heuristic methods and direct verification on the machine validated the collision model generated by the software. Encounters of <1 cm between the gantry treatment head and table were visualized as collisions in our virtual model. Visual windows were created depicting the angle of collision for each beam, including the anticipated table coordinates. Visual rendering of a 6 arc trial with multiple couch positions was completed in under 1 minute, with network bandwidth being the primary bottleneck. Conclusion: The developed software allows for quick examination of possible collisions during the treatment planning process and helps to prevent major collisions prior to plan approval. The software can easily be implemented on future planning systems due to the versatility and platform independence of the Python programming language. Further integration of the software with the treatment planning system will allow the possibility of patient-gantry collision detection for a range of treatment machines.

60 APPLIED LIFE SCIENCES↗

SU-E-T-95: Delivery Time Estimator

Purpose: The development and testing of a tool for the inclusion of delivery time as a parameter in plan optimization. Methods: We developed an algorithm that estimates the time required for the machine and personnel movements required to deliver a treatment plan on a linear accelerator. We included dose rate, leaf motion, collimator motion, gantry motion, and couch motions (including time to enter the room to rotate the couch safely). Vault-specific parameters to account for time to enter and perform couch angle adjustments were also included. This algorithm works for static, step and shoot IMRT, and VMAT beams photon beams and for fixed electron beams. This was implemented as a script in our treatment planning system. We validated the estimator against actual recorded delivery time from our R and V system as well as recorded times from our IMRT QA delivery. Results: Data was collected (Figure 1) for 12 treatment plans by examining the R and V beam start times, and by manually timing the QA treatment for a reference, but the QA measurements were only significant to the nearest minute. The average difference between the estimated and R and V times was 15%, and 11% when excluding the major outliers. Outliers arose due to respiratory aides and gating techniques which could not be accounted for in the estimator. Conclusion: Non-mechanical factors such as the time a therapist needs to walk in and out of the room to adjust the couch needed to be fine-tuned and cycled back into the algorithm to improve the estimate. The algorithm has been demonstrated to provide reasonable and useful estimates for delivery time. This estimate has provided a useful additional input for clinical decision-making when comparing several potential radiation treatment options.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-210: Independent MU Dose Calculation Software for S and S IMRT Using Modified Clarkson Integration Sector

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for S and S IMRT based in the algorithm proposed by Kung et.al. Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS and S and S IMRT modality. A 6MV photon beam produced by a Primus linear accelerator equipped with an Optifocus MLC was used. TPS dose calculation algorithms were pencil beam and Monte Carlo. 230 IMRT treatments plans were selected for the study. The software was written under MALTLAB environment. Treatment plans were imported by the software using RTP format. Field fluences were reconstructed adding all segments.The algorithm implemented in the software calculates the dose at a reference point as the sum of primary and scatter dose. The primary dose is obtained by masking the fluence map with a circle of radius 1cm. The scatter dose is obtained through a shaped ring mask around the previous circle with a thickness of 0.5cm; the rings are increased one after another with constant thickness until cover the entire map of influence. The dosimetric parameters Sc, Sp and TPR vary depending on radio, the transmission effect of the MLC, inverse square law and dose profile are used for the calculation. Results: The average difference between measured and independent calculated dose was 0.4% ± 2.2% [−6.8%, 6.4%]. For 91% of the studied plans the difference was less than 3%. The difference between the measured and TPS dose with pencilbeam algorithm was 2.6% ± 1.41% [−2.0%, 5.6%] and Monte Carlo algorithm was 0.4% ± 1.5% [−4.9%, 3.7%]. The differences obtained are comparable to that obtained with the ionization chamber and TPS. Conclusion: The developed software is suitable for use in S and S IMRT dose calculation. This application is open and can be downloading under request.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-19: A Comparison of the Dosimetric Effects of Brass Mesh and Superflab Boluses

Purpose: We compared the dosimetric effects of brass mesh (Whiting and Davis, Attleboro Falls, MA) and Superflab (CNMC, Nashville, TN) boluses to verify equivalence between the two. Brass mesh bolus may be a convenient alternative to traditional bolus as it better conforms to the skin surface. Methods: Measurements were taken using a 6MV 10×10cm field produced by an Infinity linear accelerator (Elekta, Stockholm, Sweden) in a solid water phantom using a parallel plate ion chamber (Model 96035, Keithley Instruments, Cleveland, OH). Measurements compared 0.5cm and 1cm of Superflab to one to six layers of brass bolus mesh. Measurements were performed at depths from 0cm (‘skin’) to 10cm. Oblique beams were not studied. Results: Four layers of brass mesh were equivalent to 0.5cm Superflab within 5% at all depths. Six layers of brass compares most favorably with 0.5cm Superflab, with doses at all depths within 3%. Six layers of brass were not fully equivalent to 1cm Superflab, although the agreement was within 5% for depths greater than 3mm. Surface dose was 12% lower than 1cm Superflab. Surface dose can be up to 34% different between Superflab and brass mesh, but is less than 5% different with 4–6 layers of brass when compared to 0.5cm Superflab. To achieve surface dose agreement better than 5% compared to 1cm Superflab, more than 6 layers would be needed. The attenuation at depth was a maximum of 0.17cm per layer. Conclusion: Between four and six layers of brass mesh can be equivalent to 0.5cm Superflab, depending on the level of agreement desired. Equivalence within 5% at all depths to 1cm Superflab was not achieved even with six layers. This data agrees with measurements taken by Utsunomiya et al. (2010). More point measurements at shallower depths should be taken prior to clinical implementation of brass bolus mesh.

60 APPLIED LIFE SCIENCES↗

SU-F-J-21: Clinical Evaluation of Surface Scanning Systems in Different Treatment Locations

Purpose: To reduce imaging dose in fractionated IGRT, the ability of optical surface imaging systems (OSIS) to detect setup errors was tested. Therefore, clinical studies to evaluate for different treatment locations setup corrections derived by OSIS in comparison with x-ray image guidance in fractionated radiation therapy was performed. Methods: The setup correction accuracy of an OSIS system (AlignRT, VisionRT, London, UK) will be analysed for the 4 tumour locations Pelvis, Upper Abdomen, Thorax and Breast, 20 patients for each location in comparison to a different system (Sentinel, C-RAD, SE). For each patient, the setup corrections of the cone-beam computed tomography (CBCT) of an Elekta Versa HD linear accelerator (Elekta, Crawley, UK) is considered as gold-standard and then compared with those of the OSIS for the first ten fractions retrospectively. There were no clinical decisions made based on the surrogate system. For the OSIS, the reference surface is highly important as it represents the actual ground truth. It can be obtained either with the system itself or the surface structure delineated in the planning CT can be imported via DICOM interface. In this paper, the first results for the treatment region thorax are presented. The reference image modalities were compared. Results: Table 1 displays the difference between the setup corrections obtained with OSIS and CBCT in lateral (LAT), longitudinal (LNG) and vertical (VRT) direction for the DICOM reference image. While the median deviations are within a few millimeters, some outliers showed large deviations. Generally, the mean deviation as well as the spread was smallest in lateral and largest in vertical direction. Conclusion: Although the system allows fast, simple and non-invasive determination of setup corrections, it should be evaluated treatment region dependant. Therefore, the study is ongoing. The application of OSIS may help to reduce the imaging dose for the patient. We gratefully acknowledge the support by our colleagues from the Radiological University Clinic Heidelberg, where the study was performed. This work was funded by the Federal Ministry of Education and Research (BMBF) Germany, grant number 01IB13001B.

60 APPLIED LIFE SCIENCES↗

SU-E-T-199: How Number of Control Points Influences the Dynamic IMRT Plan Quality and Deliverability

Purpose: To study the influence of number of control points on plan quality and deliverability. Methods: Five previously treated patients of carcinoma of rectum were selected. Planning target volume (PTV) and organs at risk (OARs) i.e. bladder and bowel were contoured. Dynamic IMRT plans (6MV, 7-fields, 45Gy/25 fractions and prescribed at 95% isodose) were created in Eclipse (Varian medical system, Palo Alto, CA) treatment planning system (TPS) for Varian CL2300C/D linear-accelerator. Base plan was calculated with 166 control points, variable mode (Eclipse Default). For generating other plans, all parameters were kept constant, only number of control points (Fixed mode) was varied as follows: 100, 166 and 200. Then, plan quality was analyzed in terms of maximum and mean dose received by the PTV and OARs. For plan deliverability, TPS calculated fluence was verified with I’matriXX (IBA Dosimetry, Germany) array and compared with TPS dose-plane using gamma index criteria of 3% dose difference and 3mm distance to agreement (DTA). Total number of monitor units (MU) required to deliver a plan was also noted. Results: The maximum variation for the PTV maximum with respect to eclipse default control point (166) was 0.28% (0.14Gy). Similarly, PTV mean varied only up to 0.22 %( 0.11Gy). Bladder maximum and bladder mean varied up to 0.51% (0.24Gy) and 0.16% (0.06Gy). The variation for the bowel maximum and bowel mean was also only 0.39% (0.19Gy) and 0.33% (0.04Gy). Total MU was within 0.32 % (4MU). Average gamma pass rate using different control points for five patients are 98.75±0.33%, 99.37±0.09%, 99.29±0.12%, 98.14±0.13% and 99.25±0.14% respectively. Conclusion: Slight variation (<1%) in PTV and OARs maximum and mean doses was observed with varying number of control points. Monitor unit was also not varied much. Reducing number of control points did not showed any comprise in plan deliverability in terms of gamma index pass rate.

60 APPLIED LIFE SCIENCES↗