Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Time-Dependent Reversible-Irreversible Deformation Threshold Determined Explicitly by Experimental Technique

Structural materials for the design of advanced aeropropulsion components are usually subject to loading under elevated temperatures, where a material's viscosity (resistance to flow) is greatly reduced in comparison to its viscosity under low-temperature conditions. As a result, the propensity for the material to exhibit time-dependent deformation is significantly enhanced, even when loading is limited to a quasi-linear stress-strain regime as an effort to avoid permanent (irreversible) nonlinear deformation. An understanding and assessment of such time-dependent effects in the context of combined reversible and irreversible deformation is critical to the development of constitutive models that can accurately predict the general hereditary behavior of material deformation. To this end, researchers at the NASA Glenn Research Center at Lewis Field developed a unique experimental technique that identifies the existence of and explicitly determines a threshold stress k, below which the time-dependent material deformation is wholly reversible, and above which irreversible deformation is incurred. This technique is unique in the sense that it allows, for the first time, an objective, explicit, experimental measurement of k. The underlying concept for the experiment is based on the assumption that the material s time-dependent reversible response is invariable, even in the presence of irreversible deformation.

Castelli, Michael G.↗

Intelligent uranium fission converter for neutron production on the periphery of the nuclear reactor core (MARIA reactor in Swierk - Poland)

The multipurpose, high flux research reactor MARIA in Otwock - Swierk is an open-pool type, water and beryllium moderated and graphite reflected. There are two not occupied experimental H1 and H2 horizontal channels with complex of empty rooms beside them. Making use of these two channels is not in conflict with other research or commercial employing channels. They can work simultaneously, moreover commercial channels covers the cost of reactor working. Such conditions give beneficial possibility of creating epithermal neutron stand for researches in various field at the horizontal channel H2 of MARIA reactor (co-organization of research at H1 channel is additionally planned). At the front of experimental channels the neutron flux is strongly thermalized - neutrons with energies above 0.625 eV constitute only ∼2% of the total flux. This thermalized neutron flux will be used to achieve high flux of epithermal neutrons at the level of 2x10{sup 9} n cm{sup -2}s{sup -1} by uranium neutron converter (fast neutron production - conversion of reactor core thermal neutrons to fast neutrons - and then filtering, moderating and finally cutting of unwanted gamma radiation). The intelligent converter will be placed in the reactor pool, near the front of the H2 channel. It will replace one graphite block at the periphery of MARIA graphite reflector. The converter will consist of 20 fuel elements - low enriched uranium plates. A fuel plate will be a part which will measure 110 mm wide by 380 mm long and will consist of a thin layer of uranium sealed between two aluminium plates. These plates, once assembled, form the fuel element used in converter. The plates will be positioned vertically. There are several important requirements which should be taken into account at the converter design stage: -maximum efficiency of the converter for neutrons conversion, -cooling of the converter need to be integrated with the cooling circuit of the reactor pool and if needed equipped with self-cooling system (enhanced comparing to the cooling properties inherent with regular rector pool water flows), -proper cooling conditions can be ensured by an appropriate water flow, so the resistance to flow has to be optimised, -the requirement of the minimum resistance to water flow leads to the openwork design of the fuel element separator, which, on the other hand, has to be strong enough to ensure the needed strength for mechanical load due to the fuel weight and forces associated with the water flow, -the possibility of changing beam and flux qualities by rotating the converter or repositioning the converter plates by moving or replacing with another materials. In order to minimize the neutron activation of the fuel in the converter, the possibility was predicted to remove the converter and to replace it with an aluminium dummy for the time when the beam at the channel H2 is not used. This means that both, the converter and the dummy, have to be easily removable from the converter socket. There has to be also the place in the water pool, near the research stand or in technological pool, where the converter can be safely stored (this place have to be proper for operation with plates i.e. changing amount of plates). Thermal and neutron load of the fuel plates in the converter will be inhomogeneous. In order to equalize these loads, the converter should be designed in such way that it would be possible to change the order of fuel plates. Moreover replacing the amount of the plates gives the opportunity to obtain different fluxes of neutrons (quantitatively and qualitatively i.e. energetically). The project of the converter is based on Monte Carlo calculation concerning neutron production and on Computational Fluid Dynamics (CFD) i.e. modelling of converter for thermodynamical aspects. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Universal Mechanism of Viscoplastic Deformation of Metallic Materials Far from Thermodynamics Equilibrium

The article gives results of structure formation in metallic materials after different types of deformation: tungsten after rolling, nickel after thermal cycling and nickel single crystal after rolling, aluminum single crystal after cyclic tension and aluminum alloys (D16, 2024-T3) after impulsive load. We used optical and electron microscopy methods for investigation of deformation structure formation and molecular dynamics method for computer modeling of the processes of plastic deformation (LAMMPS software). The following quantitative parameters were calculated during the simulation: energy of pair interaction, temperature, total cumulative pressure, stress tensor and pressure tensor. The study shows that the plastic flow of metallic materials with any initial structure at certain loading stage can be carried out by homogeneous mass transfer through channels with a liquid-like structure, from which follows that the dislocation mechanism of plastic deformation of crystals has a limited field of application. The main role has a synergistic structure formation in the conditions of distance from thermodynamic equilibrium. The relaxation processes proceed intensively after and during the process of destruction. The results of modeling have shown the possibility of forming channels of hydrodynamic flow without the participation of defects in the initial material.

36 MATERIALS SCIENCE↗

A method for modeling finite-core vortices in wake-flow calculations

A numerical method for computing nonplanar vortex wakes represented by finite-core vortices is presented. The approach solves for the velocity on an Eulerian grid, using standard finite-difference techniques; the vortex wake is tracked by Lagrangian methods. In this method, the distribution of continuous vorticity in the wake is replaced by a group of discrete vortices. An axially symmetric distribution of vorticity about the center of each discrete vortex is used to represent the finite-core model. Two distributions of vorticity, or core models, are investigated: a finite distribution of vorticity represented by a third-order polynomial, and a continuous distribution of vorticity throughout the wake. The method provides for a vortex-core model that is insensitive to the mesh spacing. Results for a simplified case are presented. Computed results for the roll-up of a vortex wake generated by wings with different spanwise load distributions are presented; contour plots of the flow-field velocities are included; and comparisons are made of the computed flow-field velocities with experimentally measured velocities.

Stremel, P. M.↗

Evaluation of a CFD Method for Aerodynamic Database Development using the Hyper-X Stack Configuration

A computational fluid dynamic (CFD) study is performed on the Hyper-X (X-43A) Launch Vehicle stack configuration in support of the aerodynamic database generation in the transonic to hypersonic flow regime. The main aim of the study is the evaluation of a CFD method that can be used to support aerodynamic database development for similar future configurations. The CFD method uses the NASA Langley Research Center developed TetrUSS software, which is based on tetrahedral, unstructured grids. The Navier-Stokes computational method is first evaluated against a set of wind tunnel test data to gain confidence in the code s application to hypersonic Mach number flows. The evaluation includes comparison of the longitudinal stability derivatives on the complete stack configuration (which includes the X-43A/Hyper-X Research Vehicle, the launch vehicle and an adapter connecting the two), detailed surface pressure distributions at selected locations on the stack body and component (rudder, elevons) forces and moments. The CFD method is further used to predict the stack aerodynamic performance at flow conditions where no experimental data is available as well as for component loads for mechanical design and aero-elastic analyses. An excellent match between the computed and the test data over a range of flow conditions provides a computational tool that may be used for future similar hypersonic configurations with confidence.

Parikh, Paresh↗

Validation of new and existing methods for time-domain simulations of turbulence and loads

We seek to obtain a second-by-second match between the simulated and measured structural loads of a utility-scale wind turbine. To obtain the one-to-one load simulations, we start with the furthest upstream component of the modeling chain: the turbulent inflow. We consider new and existing methods to generate constrained-turbulence flow fields. The new method is based on large-eddy simulations (LES) and machine learning (ML). The existing methods include Kaimal-based TurbSim and the superstatistical wind field model. The inflow measurements used to constrain these simulations are obtained with a nacelle-mounted scanning lidar. We compare the flow fields for the different inflow simulation approaches and validate their associated load predictions against measurements collected in the Rotor Aero-dynamics, Aeroelastics, and Wake (RAAW) field campaign. We find that the rotor-position control developed for this study is key in enabling the time match between measurements and simulations. When this control approach is used, the load simulation performance tracks with the inflow simulation fidelity, with LES+ML yielding errors ≤ 4% for the damage-equivalent loads of flapwise bending moment, and tower fore-aft bending moments.

17 WIND ENERGY↗

Loading and Regeneration Analysis of a Diesel Particulate Filter with a Radio Frequency-Based Sensor

Accurate knowledge of diesel particulate filter (DPF) loading is critical for robust and efficient operation of the combined engine-exhaust aftertreatment system. Furthermore, upcoming on-board diagnostics regulations require on-board technologies to evaluate the status of the DPF. This work describes the application of radio frequency (RF) based sensing techniques to accurately measure DPF soot levels and the spatial distribution of the accumulated material. A 1.9L GM turbo diesel engine and a DPF with an RF-sensor were studied. Direct comparisons between the RF measurement and conventional pressure-based methods were made. Further analysis of the particulate matter loading rates was obtained with a mass-based soot emission measurement instrument (TEOM). Comparison with pressure drop measurements show the RF technique is unaffected by exhaust flow variations and exhibits a high degree of sensitivity to DPF soot loading and good dynamic response. Additional computational and experimental work further illustrates the spatial resolution of the RF measurements. Based on the experimental results, the RF technique shows significant promise for improving DPF control enabling optimization of the combined engine-aftertreatment system for improved fuel economy and extended DPF service life.

33 ADVANCED PROPULSION SYSTEMS↗

Experimental and analytical studies of a model helicopter rotor in hover

A benchmark test to aid the development of various rotor performance codes was conducted. Simultaneous blade pressure measurements and tip vortex surveys were made for a wide range of tip Mach numbers including the transonic flow regime. The measured tip vortex strength and geometry permit effective blade loading predictions when used as input to a prescribed wake lifting surface code. It is also shown that with proper inflow and boundary layer modeling, the supercritical flow regime can be accurately predicted.

Caradonna, F. X.↗

Investigation of the tip clearance flow inside and at the exit of a compressor rotor passage. II - Turbulence properties

The flow in the tip clearance region of a compressor rotor is highly turbulent due to the strong interaction of the leakage flow with the annulus wall boundary layer. This paper deals with the turbulence properties of the flow in the tip clearance region of a moderately loaded compressor rotor. The experimental results reported in this paper were obtained using a two-sensor hot-wire probe in combination with an ensemble averaging technique. Blade-to-blade distribution of the axial and tangential turbulence intensities at various radial locations and ten axial locations (four inside the blade passage and the remaining six outside the passage) were derived from this data. Isointensity contours in the clearance region at various radial locations were also obtained from the experimental data. A region of very high turbulence intensities was indicated at the half-chord location from these results. The turbulence intensity profiles also indicated that the leakage flow travels toward the midpassage before rolling up. The turbulence is almost isotropic beyond three-quarter chord downstream of the trailing edge.

Pandya, A.↗

A Two-Step Load Disaggregation Algorithm for Quasi-static Time-series Analysis on Actual Distribution Feeders

This paper focuses on developing a two-step load disaggregation method for conducting quasi-static time-series analysis using actual distribution feeder data. This can help utilities conduct power flow studies using smart meter measurements to assess the impact of high penetration of distributed energy resources. In the first step, load profiles of residential and commercial buildings obtained from smart meter data are used to match the load profile at the feeder head. This step will determine the number of residential and commercial loads on the feeder. The second step is to allocate the selected load profiles to each load node based on its transformer rating. This allows each load node to have its own load profile and the aggregation of those nodal load profiles matches closely to the metered feeder load shape at the substation. This algorithm is validated using smart meter data and the SCADA data of a real feeder. We compared the performance of the proposed method with the traditional load allocation method (i.e. use the feeder load shape for all subsequent load nodes scaling by the transformer capacities) when conducting quasi-static power flow studies. Results show that the proposed algorithm matches the utility data well and the obtained voltage profiles reveal more voltage dynamics than using the conventional load allocation method. (PDF) A Two-Step Load Disaggregation Algorithm for Quasi-static Time-series Analysis on Actual Distribution Feeders.

load disaggregation, load shape, quasi-static, tim↗

The effect of circumferential distortion on fan performance at two levels of blade loading

Single stage fans designed for two levels of pressure ratio or blade loading (rotor tip D-factor of 0.43 and 0.54) were subjected to screen-induced circumferential distortions of 90-degree extent. Both fan rotors were designed for a blade tip speed of 425 m/sec, blade solidity of 1.3 and a hub-to-tip radius ratio of 0.5. Circumferential measurements of total pressure, temperature, static pressure, and flow angle were obtained at the hub, mean and tip radii at five axial stations (three between the screen and rotor and behind rotor and stator blade rows). Rotor loading level did not appear to have a significant influence on rotor response to distorted flow. Losses in overall pressure ratio due to distortion were most severe in the stator hub region of the more highly loaded stage. At the near stall operating condition tip and hub regions of (either) rotor demonstrated different response characteristics to the distorted flow. No effect of loading was apparent on interactions between rotor and upstream distorted flow fields.

Hartmann, M. J.↗

Structural Analysis Findings of Open Spelter Socket Cable Terminations

A three-dimensional nonlinear finite element model of a representative open spelter socket termination was developed to examine the underlying mechanics of load transfer from a structural cable through the termination, the sensitivity of the joint design to wire brooming, zinc material nonlinearity, contact friction between the zinc and socket, voids within the zinc, and, finally, the effects of repeated loading on the joint. Primary factors affecting open spelter socket design are cast zinc plastic flow, depth of zinc slug seating, and quality of wire brooming. Zinc plasticity and proper brooming allows for efficient load transfer by developing confining pressure on the broomed wires in the narrow part of the socket, which keep the wires from pulling out of the zinc and shift failure to occur outside the socket. Highest wire stresses in the cable occur in the outer ring adjacent to the termination. While industry use of stay cables are typically designed to carry less than half the rated breaking force in aggregate, the constituent stresses within the zinc and the wires have the potential to exceed their respective allowable in operation and should be evaluated for fatigue- and creep-critical applications.

Pavel Babuska↗

Optimization of a Centrifugal Impeller Design Through CFD Analysis

This paper discusses the procedure, approach and Rocketdyne CFD results for the optimization of the NASA consortium impeller design. Two different approaches have been investigated. The first one is to use a tandem blade arrangement, the main impeller blade is split into two separate rows with the second blade row offset circumferentially with respect to the first row. The second approach is to control the high losses related to secondary flows within the impeller passage. Many key parameters have been identified and each consortium team member involved will optimize a specific parameter using 3-D CFD analysis. Rocketdyne has provided a series of CFD grids for the consortium team members. SECA will complete the tandem blade study, SRA will study the effect of the splitter blade solidity change, NASA LeRC will evaluate the effect of circumferential position of the splitter blade, VPI will work on the hub to shroud blade loading distribution, NASA Ames will examine the impeller discharge leakage flow impacts and Rocketdyne will continue to work on the meridional contour and the blade leading to trailing edge work distribution. This paper will also present Rocketdyne results from the tandem blade study and from the blade loading distribution study. It is the ultimate goal of this consortium team to integrate the available CFD analysis to design an advanced technology impeller that is suitable for use in the NASA Space Transportation Main Engine (STME) fuel turbopump.

Chen, W. C.↗

Load Shed Recovery With Transmission Switching and Intentional Islanding Methods After (N-2) Line Contingencies

Changing power system configuration may result in load shed recovery (LSR) because topology change can provide power flow control in meshed network. Some topologies may favor generation redispatch as compared to others and can eliminate line congestion which leads to LSR. One of the known methods for topology change is called transmission switching (TS) and research conducted in the past showed that TS is an effective means of mitigating load shedding. Another method of topology control is intentional islanding (IIS). In this manuscript, we explore IIS as a potential solution for LSR. IIS based on generator coherency has been presented in literature for mitigating cascading failures. However, IIS has not been explored solely as a LSR mechanism. In this paper, we compare the LSR based on IIS with well known LSR algorithm based on TS. The comparison is performed for IEEE 39-bus system and IEEE 118- bus system. The results show that IIS has a potential to perform better than TS in terms of computational efficiency and LSR.

42 ENGINEERING↗

Characterization of self-magnetic pinch radiographic diode performance on RITS-6 at Sandia National Laboratories. II. Coupling between the inductive voltage adder and the SMP load

The self-magnetic pinch (SMP) diode is a type of radiographic diode used to generate an intense electron beam for radiographic applications. At Sandia National Laboratories, SMP was the diode load for the six-cavity radiographic integrated test stand inductive voltage adder (IVA) driver operated in a magnetically insulated transmission line (MITL). The MITL contributes a flow current in addition to the current generated within the diode itself. Extensive experiments with a MITL of 40Ω load impedance [T. J. Renk et al., Phys. Plasmas 29, 023105 (2022)] indicate that the additional flow current leads to results similar to what might be expected from a conventional high-voltage interface driver, where flow current is not present. However, when the MITL flow impedance was increased to 80 Ω, qualitatively different diode behavior was observed. This includes large retrapping waves suggestive of an initial coupling to low impedance as well as diode current decreasing with time even as the total current does not. A key observation is that the driver generates total current (flow + diode) consistent with the flow impedance of the MITL used. The case is made in this paper that the 80Ω MITL experiments detailed here can only be understood when the IVA-MITL-SMP diode is considered as a total system. Additionally, the constraint of fixed total current plus the relatively high flow impedance limits the ability of the diode (whether SMP or other type) to act as an independent load. An unexpected new result is that in tracking the behavior of the electron strike angle on the converter as a function of time, we observed that the conventional cIV x “Radiographic” radiation scaling (where x~2.2) begins to break down for voltages above 8 MV, and cubic scaling is required to recover accurate angle tracking.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources: Preprint

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

61 RADIATION PROTECTION AND DOSIMETRY↗

Flow strength of tantalum under ramp compression to 250 GPa

A magnetic loading technique was used to study the strength of polycrystalline tantalum ramp compressed to peak stresses between 60 and 250 GPa. Velocimetry was used to monitor the planar ramp compression and release of various tantalum samples. A wave profile analysis was then employed to determine the pressure-dependence of the average shear stress upon unloading at strain rates on the order of 10{sup 5} s{sup −1}. Experimental uncertainties were quantified using a Monte Carlo approach, where values of 5% in the estimated pressure and 9–17% in the shear stress were calculated. The measured deviatoric response was found to be in good agreement with existing lower pressure strength data as well as several strength models. Significant deviations between the experiments and models, however, were observed at higher pressures where shear stresses of up to 5 GPa were measured. Additionally, these data suggest a significant effect of the initial material processing on the high pressure strength. Heavily worked or sputtered samples were found to support up to a 30% higher shear stress upon release than an annealed material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of turbulence and thermophysical fluid properties on cavitation erosion predictions in channel flow geometries

Cavitation and cavitation-induced erosion have been observed in fuel injectors in regions of high acceleration and low pressure. Although these phenomena can have a large influence on the performance and lifetime of injector hardware, questions still remain on how these physics should be accurately and efficiently represented within a computational fluid dynamics model. While several studies have focused on the validation of cavitation predictions within canonical and realistic injector geometries, it is not well documented what influence the numerical and physical parameters selected to represent turbulence and phase change will have on the predictions for cavitation erosion propensity and severity. In this work, a range of numerical and physical parameters are evaluated within the mixture modeling approach in CONVERGE to understand their influence on predictions of cavitation, condensation and erosion. Particular attention is paid to grid resolution, turbulence model and near-wall treatment, fuel surrogate properties, and non-condensable gas content. Assessment of cavitation predictions are conducted through comparison of measured and predicted mass flow rates and cavitation probability distributions for flow through a channel with a sharp inlet. Predictions for hydrodynamic impact loading and cavitation erosion are compared with the experimentally measured incubation period and critical site for erosion. Based on these findings, recommendations are provided for modeling turbulent cavitating flows, using the single fluid mixture modeling approach, to improve predictions for cavitation-induced erosion. In particular, to capture the fluid dynamic phenomena characterizing cavitation cloud formation, development and shedding, a Large Eddy simulation with grid resolution as fine as 2.50 μm is recommended. The assumed concentration of non-condensable gas content is observed to have a strong influence on the predicted cavitation erosion severity, which motivates the need for dissolved gas concentration measurements for future cavitation erosion experimental studies. Using the best practices established in this work, good agreement is achieved between the measured and predicted cavitation parameters, as well as the critical site for cavitation-induced erosion.

Magnotti, Gina Maureen↗