Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Application of IR imaging for free-surface velocity measurement in liquid-metal systems

Measuring free-surface, liquid-metal flow velocity is challenging to do in a reliable and accurate manner. This paper presents a non-invasive, easily calibrated method of measuring the surface velocities of open-channel liquid-metal flows using an IR camera. Unlike other spatially limited methods, this IR camera particle tracking technique provides full field-of-view data that can be used to better understand open-channel flows and determine surface boundary conditions. Lastly, this method could be implemented and automated for a wide range of liquid-metal experiments, even if they operate at high-temperatures or within strong magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting focusing lenses for the SSR-1 cryomodule of PXIE test stand at Fermilab

Five solenoid-based focusing lenses designed for use inside the SSR1 cryomodule of the PXIE test stand at Fermilab have been fabricated and tested. In addition to a focusing solenoid, each lens is equipped with a set of windings that generate magnetic field in the transverse plane and can be used in the steering dipole mode or as a skew quadrupole corrector. The lenses will be installed between superconducting cavities in the cryomodule, so getting sufficiently low fringe magnetic field was one of the main design requirements. Beam dynamics simulations indicated a need for high accuracy positioning of the lenses in the cryomodule, which triggered a study towards understanding uncertainties of the magnetic axis position relative to the geometric features of the lens. Furthermore, this report summarizes the efforts towards certification of the lenses, including results of performance tests, fringe field data, and uncertainty of the magnetic axis position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Participant Support for Speakers and Early-Career Scientists at the 2012 American Conference on Neutron Scattering (ACNS)

The ACNS provides a focal point for the North American neutron user community, strengthening ties within this diverse group, and promoting neutron research in related disciplines. The conference thus serves a dual role as both a national user meeting and a scientific meeting. As a venue for scientific exchange, the ACNS showcases recent results and provides a forum for scientific discussion of neutron-enabled research in fields as diverse as hard and soft condensed matter, liquids, biology, magnetism, engineering materials, chemical spectroscopy, crystal structure, elementary excitations, fundamental physics, and development of neutron instrumentation. This is achieved through a combination of invited oral presentations, contributed oral presentations, and poster sessions. Adequate opportunity for spontaneous discussion and collaboration is also built into the ACNS program in order to foster free exchange of new scientific ideas and the potential for use of powerful neutron scattering methods beyond the current realms of application. The sixth American Conference on Neutron Scattering (ACNS 2012) provided essential information on the breadth and depth of current neutron-related research worldwide. A strong program of plenary, invited and contributed talks showcased recent scientific results in neutron science in a wide range of fields, including soft and hard condensed matter, biology, chemistry, energy and engineering applications, and neutron physics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fiber optic sensing for strain and temperature

Fiber optic sensing for strain and temperature. This presentation reports the status of the R&D work performed at FNAL on a novel diagnostic tool for superconducting magnet based on fiber optics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

0.4- to 10-GHz airborne electromagnetic-environment survey of United States urban areas

An airborne electromagnetic-environment survey of some U.S. metropolitan areas measured terrestrial emissions within the broad-frequency spectrum from 0.4 to 10 GHz. A Cessna 402 commercial aircraft was fitted with both nadir-viewing and horizon-viewing antennas and instrumentation, including a spectrum analyzer, a 35-mm continuous-film camera, and a magnetic-tape recorder. Most of the flights were made at a nominal altitude of 10,000 ft, and Washington, Baltimore, Philadelphia, New York, and Chicago were surveyed. The 450- to 470-MHz land-mobile UHF band is especially crowded, and the 400- to 406-MHz space bands are less active. Test measurements obtained up to 10 GHz are discussed. Sample spectrum-analyzer photographs were selected from a total of 5750 frames representing 38 hours of data.

Taylor, R. E.↗

Magnetic deflection ion mass spectrometer experiment for atmosphere explorer

The magnetic ion mass spectrometer was carried aboard Atmosphere Explorer C and Atmosphere Explorer D. The instrument measures the relative abundance of ionic species with very high sensitivity and very high mass resolution. Thus isotopic ratios for various ion species can be examined and minor ion species such as O(++), N(++), and H(+) can be detected when their relative abundance is very small. These instruments functioned with no critical internal failures but the premature loss of the AE-D spacecraft after only a few months of operation has led to an emphasis of scientific achievement from AE-C. The very long lifetime of AE-C coupled with the prolonged time that this spacecraft spent near the F-region peak led to the accumulation of very large count numbers in the channeltron detectors.

Hoffman, J. H.↗

In Situ Data

In-situ planetary data include all measurements made by a wide variety of instruments whose sensors are exposed directly to the planetry environment. Typical measurements include those of magnetic fields, energetic particle densities and energy distributions, plasma wave characteristics, ionospheric and neutral gas densities, temperatures, composition and motions. A large body of scientists in the United States, and the world, are involved in research using in-situ data. Many of these scientists are associated with Mission investigations groups which provide specific types of in-situ data. These groups, in the course of data analysis, use data provided by similar groups. The interdisciplinary nature of these investigations fosters exchange and reliance upon one another for data is heavy. To a lesser extent, correlative data sets are obtained from the National Space Science Data Center (NSSDC). However, the data entries often have limited temporal and spatial resolution, are of uncertain quality, and are usually available only for measurements that are several years old.

Source record↗

A measurement of the absolute flux of cosmic-ray electrons

A balloon-borne superconducting magnet spectrometer was used to measure the absolute flux of cosmic-ray electrons. The instrument consisted of a gas Cerenkov detector, a momentum spectrometer, and a lead-scintillator shower counter. In order to determine electron flux in the interstellar medium, observed fluxes for energy loss in the atmosphere and the payload were corrected, taking into account solar modulation effects and bremsstrahlung energy losses. Fluxes were measured at an average atmospheric depth of 5.8 g/sq cm, and the solar modulation was 300 MeV. A cosmic-ray electron flux of 367 E to the exp(3.15 + or -0.2) per sq m/sr s GeV was obtained in the energy range 4.5-63.5 GeV. The uncertainty of the absolute (electron-positron) flux was 10 percent. A summary of the electron data is given in a table.

Golden, R. L.↗

Studying antiprotons from balloons and Space Station

Experimental measurements are proposed to determine the existence of cosmic antiprotons and to differentiate between various hypothetical origins for them. The balloon-borne experiment proposed by Balasubrahmanyan et al. (1983) for detecting 50-220-MeV antiprotons and measuring their energy distribution is described; the astrophysical significance of antiproton measurements is considered; the antiproton/proton ratios predicted by various cosmic-ray and exotic models are presented graphically; and the performance required of a Space Station superconducting-magnet detector for the 10-1000-GeV range is discussed. It is concluded that an instrument with 0.3-sq m sr geometry could distinguish (at a 5-sigma level) between hypotheses with spectral-exponent separation of 0.1 in observing time about 1 month, assuming a spectral exponent as steep as E to the -3rd.

Ormes, J. F.↗

Design of the polarimeter for the Solar Activity Measurements Experiments (SAMEX) vector magnetograph

A design concept developed for a polarimeter on the vector magnetograph of the SAMEX satellite that would be very sensitive to solar vector magnetic fields is described. A description of the Poincare sphere is presented, along with the instrument scientific requirements, to provide an understanding of how the polarimeter design has been selected. It is shown that the design goal of a polarimetric sensitivity of 0.0001 can be achieved in the linear measurements using a hybrid analyzer. It is also noted that the systematic errors that produce linear crosstalk into the circular measurement will require the use of the redundant polarization measurements for in-flight calibrations and corrections of the data.

West, E. A.↗

The Ulysses mission

The Ulysses mission is unique in the history of the exploration of solar system by spacecraft. The path followed by Ulysses will make it possible, for the first time, to explore the heliosphere within a few astronomical units of the sun over the full range of heliographic latitudes, thereby providing the first characterization of the uncharted third heliospheric dimension. Advanced scientific instrumentation carried on board the spacecraft is designed to measure the properties of the heliospheric magnetic field, the solar wind, the sun/wind interface, solar radio bursts and plasma waves, solar energetic particles and galactic cosmic rays, solar X-rays, and interplanetary/interstellar neutral gas and dust. Ulysses will also be used to detect cosmic gamma-ray bursts and search for gravitational waves. The mission, a collaboration between ESA and NASA, was launched in October 1990 and employs a Jupiter gravity-assist to achieve the trajectory extending to high solar latitudes. The paper describes the characteristics of the Ulysses mission in order to establish a framework within which to better understand the objectives and goals of the scientific investigations.

Wenzel, K.-P.↗

Satellite Studies of Ionospheric Electric Fields and Neutral Winds

We have studied mid- and low-latitude electrodynamic and neutral thermospheric dynamic processes using measurements on board the AE-E, DE-2, and UARS (Upper Atmosphere Research Satellite) satellites, and global convection and general circulation models. These studies have determined the morphology of the equatorial zonal electric fields, the response of equatorial plasma irregularities to magnetospheric disturbances, and the time dependent response of the mid- and low latitude electric fields to magnetospheric disturbances. We have also used extensive F region zonal and meridional wind data obtained by Wind Imaging Interferometer (WINDII) instrument on board the UARS to study the latitudinal dependence of daytime disturbance winds during magnetically disturbed periods and the general characteristics of the global thermospheric disturbance wind system during geomagnetically active periods. This project has supported the PhD thesis research of John Emmert.

Fejer, Bela G.↗

CIV Polarization Measurements using a Vacuum Ultraviolet Fabry-Perot Interferometer

Marshall Space Flight Center's (MSFC) is developing a Vacuum Ultraviolet (VUV) Fabry-P rot Interferometer that will be launched on a sounding rocket for high throughput, high-cadence, extended field of view CIV (155nm) measurements. These measurements will provide (i) Dopplergrams for studies of waves, oscillations, explosive events, and mass motions through the transition region, and, (ii), polarization measurements to study the magnetic field in the transition region. This paper will describe the scientific goals of the instrument, a brief description of the optics and the polarization characteristics of the VUV Fabry P rot.

West, Edward↗

CIV Polarization Measurements Using a Vacuum Ultraviolet Fabry Perot

Marshall Space Flight Center's (MSFC) is developing a Vacuum Ultraviolet (VUV) Fabry Perot that will be launched on a sounding rocket for high throughput, high-cadence, extended field of view CIV (155nm) measurements. These measurements will provide (i) Dopplergrams for studies of waves, oscillations, explosive events, and mass motions through the transition region, and, (ii), polarization measurements to study the magnetic field in the transition region. This paper will describe the scientific goals of the instrument, a brief description of the optics and the polarization characteristics of the VUV Fabry Perot.

West, Edward A.↗

SSR1 Cryomodule Design PXIE

Fermilab is planning to design and build a Project X Injector Experiment (PXIE), a cw linac, as a means of validating the Project X concept, reducing technical risks, and obtaining experience in the design and operation of a superconducting pr oton linac. The overall facility will include an ion source, low and medium-energy beam transport sections, a radio frequency quadrupole, and two cryomodules containing superconducting cavities. One will contain nine half-wave resonators operating at 162. 5 MHz and six superconducting solenoids. The second will contain eight single spoke resonators (SSR1) operating at 325 MHz and four superconducting solenoids. This paper describes the design of the cryomodule being developed to house the 325 MHz single sp oke resonators. Each of the main cryomodule systems will be described; cryogenic systems and instrumentation, cavity and solenoid positioning and alignment, conduction-cooled current leads, RF input couplers, magnetic shielding, cold-to-warm beam tube tra nsitions, interfaces to interconnecting equipment and adjacent modules, as well as the overall assembly procedure.

43 PARTICLE ACCELERATORS↗

Application of partially coherent wavefront propagation calculations for design of coherence-preserving synchrotron radiation beamlines

Ultra-low emittance third-generation synchrotron radiation (SR) sources, such as NSLS-II and MAX-IV, will offer excellent opportunities for further development of experimental techniques exploiting X-ray coherence. However, even in these new SR sources, the radiation produced by relativistic electrons (in undulators, wigglers and bending magnets) will remain only partiallycoherent in the X-ray spectral range. 'Extraction' of 'coherent portion' of the radiation flux and its transport to sample without loss of coherence must be performed by dedicated SR beamlines, optimized for particular types of experiments. Detailed quantitative prediction of partially coherent X-ray beam properties at propagation through optical elements, which is required for the optimization of such beamlines, can only be obtained from accurate and efficient physical-optics based numerical simulations. Examples of such simulations, made for NSLS-II beamlines, using 'Synchrotron Radiation Workshop' (SRW) computer code, are presented. Special attention is paid to the numerical analysis of the basic properties of partially coherent undulator radiation beam and its distinctions from the Gaussian beam. Performance characteristics of importance for particular beamlines, such as radiation spot size and flux at sample vs size of secondary source aperture for high-resolution microscopy beamlines, are predicted by the simulations.

43 PARTICLE ACCELERATORS↗

Whistler mode waves and the electron heat flux in the solar wind: cluster observations

The nature of the magnetic field fluctuations in the solar wind between the ion and electron scales is still under debate. Using the Cluster/STAFF instrument, we make a survey of the power spectral density and of the polarization of these fluctuations at frequencies f in [1, 400] Hz, during five years (2001-2005), when Cluster was in the free solar wind. In ∼10% of the selected data, we observe narrowband, right-handed, circularly polarized fluctuations, with wave vectors quasi-parallel to the mean magnetic field, superimposed on the spectrum of the permanent background turbulence. We interpret these coherent fluctuations as whistler mode waves. The lifetime of these waves varies between a few seconds and several hours. Here, we present, for the first time, an analysis of long-lived whistler waves, i.e., lasting more than five minutes. We find several necessary (but not sufficient) conditions for the observation of whistler waves, mainly a low level of background turbulence, a slow wind, a relatively large electron heat flux, and a low electron collision frequency. When the electron parallel beta factor β {sub e∥} is larger than 3, the whistler waves are seen along the heat flux threshold of the whistler heat flux instability. The presence of such whistler waves confirms that the whistler heat flux instability contributes to the regulation of the solar wind heat flux, at least for β {sub e∥} ≥ 3, in slow wind at 1 AU.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of fast cooling pulsed magnets at the Wuhan National High Magnetic Field Center

Pulsed magnets with fast cooling channels have been developed at the Wuhan National High Magnetic Field Center. Between the inner and outer sections of a coil wound with a continuous length of CuNb wire, G10 rods with cross section 4 mm × 5 mm were inserted as spacers around the entire circumference, parallel to the coil axis. The free space between adjacent rods is 6 mm. The liquid nitrogen flows freely in the channels between these rods, and in the direction perpendicular to the rods through grooves provided in the rods. For a typical 60 T pulsed magnetic field with pulse duration of 40 ms, the cooling time between subsequent pulses is reduced from 160 min to 35 min. Subsequently, the same technology was applied to a 50 T magnet with 300 ms pulse duration. The cooling time of this magnet was reduced from 480 min to 65 min.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗