Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Qubit addressing using hyperfine-interaction control by an electric field in a magnetic crystal

We demonstrate experimentally the hyperfine-interaction control by an electric field, which is the operating principle of the addressable qubit operation in a silicon-based solid-state quantum computer in a new quantum computer system, a magnetic crystal. The transferred hyperfine field at a F{sup -} nucleus caused by neighboring Mn{sup 2+} electron spins in an antiferromagnetic MnF{sub 2} single crystal was measured by {sup 19}F nuclear magnetic resonance (NMR) with an external electric field applied along the [110] crystal direction. The electric field splits the {sup 19}F NMR peak into two resolved lines that come from the F nuclei located at geometrically equivalent sites. A line splitting of 56 kHz was achieved at an electric field of 3.4 V/{mu}m. One of the F{sup -} nuclear spins could be flipped selectively by a composite radio-frequency pulse while leaving the other unchanged, thereby demonstrating qubit addressing via electric field control of the hyperfine interaction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identification and Quantification of Technetium Species in Hanford Waste Tank AN-102

Technetium-99 (Tc) generated from the fission of 235U and 239Pu in high yields is one of the most difficult contaminants to be addressed at the U.S. Department of Energy Hanford Site. In strongly alkaline solutions typifying Hanford tank waste, Tc exists as pertechnetate (TcO4-) (oxidation state VII) as well as in reduced forms (oxidation state < VII) collectively known as non-pertechnetate species. Designing strategies for effective Tc management, including separation and immobilization, necessitates understanding the molecular structure of the non- pertechnetate species and their identification in the actual tank waste samples, which would facilitate development of new treatment technologies effective for dissimilar Tc species. Toward this objective, a spectroscopic library of the Tc(I) [fac-Tc(CO)3]+ and Tc(IV, VII) compounds was generated using a range of techniques and applied to the characterization of the actual tank waste supernatant collected from the tank 241-AN-102 at Hanford, WA. A sample of the 241-AN-102 tank waste supernatant was processed to adjust Na concentration to about 5.6 M and remove 137Cs by spherical resorcinol-formaldehyde (sRF) ion exchange resin. Cesium-loaded sRF column was eluted with 0.5 M HNO3. As received AN-102, Cs-depleted AN-102 effluent, and sRF eluate fractions were comprehensively characterized for chemical composition and speciation of Tc using 99Tc nuclear magnetic resonance spectroscopy and X-ray absorption spectroscopy. It was demonstrated for the first time that non-pertechnetate Tc present in the 241-AN-102 tank waste is composed of several low-valent Tc species, including the Tc(I) [fac-Tc(CO)3]+ and Tc(IV) compounds. This is the second experimental observation of the [fac-Tc(CO)3]+ species in the Hanford tank waste and the first demonstration of multiple forms of non-pertechnetate species existing simultaneously in the waste, cumulatively highlighting their importance for the waste processing.

Low Activity Waste (LAW), High Level Waste, nuclea↗

Three-Dimensional Charge Density Wave Order in YBa2Cu3O6.67 at High Magnetic Fields

Charge density wave (CDW) correlations have been shown to universally exist in cuprate superconductors. However, their nature at high fields inferred from nuclear magnetic resonance is distinct from that measured by x-ray scattering at zero and low fields. Here we combine a pulsed magnet with an x-ray free electron laser to characterize the CDW in YBa2Cu3O6.67 via x-ray scattering in fields up to 28 Tesla. While the zero-field CDW order, which develops below T ~ 150 K, is essentially two-dimensional, at lower temperature and beyond 15 Tesla, another three-dimensionally ordered CDW emerges. The field-induced CDW onsets around the zero-field superconducting transition temperature, yet the incommensurate inplane ordering vector is field-independent. This implies that the two forms of CDW and hightemperature superconductivity are intimately linked.

Gerber, S.↗

Improving NMR Protein Structure Quality by Rosetta Refinement: A Molecular Replacement Study

The structure of human protein HSPC034 has been determined by both solution nuclear magnetic resonance (NMR) spectroscopy and X-ray crystallography. Refinement of the NMR structure ensemble, using a Rosetta protocol in the absence of NMR restraints, resulted in significant improvements not only in structure quality, but also in molecular replacement (MR) performance with the raw X-ray diffraction data using MOLREP and Phaser. This method has recently been shown to be generally applicable with improved MR performance demonstrated for eight NMR structures refined using Rosetta (Qian et al., Nature 2007;450:259–264). Additionally, NMR structures of HSPC034 calculated by standard methods that include NMR restraints have improvements in the RMSD to the crystal structure and MR performance in the order DYANA, CYANA, XPLOR-NIH, and CNS with explicit water refinement (CNSw). Further Rosetta refinement of the CNSw structures, perhaps due to more thorough conformational sampling and/or a superior force field, was capable of finding alternative low energy protein conformations that were equally consistent with the NMR data according to the Recall, Precision, and F-measure (RPF) scores. On further examination, the additional MR-performance shortfall for NMR refined structures as compared with the X-ray structure were attributed, in part, to crystal-packing effects, real structural differences, and inferior hydrogen bonding in the NMR structures. A good correlation between a decrease in the number of buried unsatisfied hydrogen-bond donors and improved MR performance demonstrates the importance of hydrogen-bond terms in the force field for improving NMR structures. The superior hydrogen-bond network in Rosetta-refined structures demonstrates that correct identification of hydrogen bonds should be a critical goal of NMR structure refinement. Inclusion of nonbivalent hydrogen bonds identified from Rosetta structures as additional restraints in the structure calculation results in NMR structures with improved MR performance.

Environmental Molecular Sciences Laboratory↗

Gamma ray irradiated silicon nanowires: An effective model to investigate defects at the interface of Si/SiOx

The effect of gamma ray irradiation on silicon nanowires was investigated. Here, an additional defect emerged in the gamma-ray-irradiated silicon nanowires and was confirmed with electron spin resonance spectra. {sup 29}Si nuclear magnetic resonance spectroscopy showed that irradiation doses had influence on the Q{sup 4} unit structure. This phenomenon indicated that the unique core/shell structure of silicon nanowires might contribute to induce metastable defects under gamma ray irradiation, which served as a satisfactory model to investigate defects at the interface of Si/SiOx.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atomic magnetic gradiometer for room temperature high sensitivity magnetic field detection

A laser-based atomic magnetometer (LBAM) apparatus measures magnetic fields, comprising: a plurality of polarization detector cells to detect magnetic fields; a laser source optically coupled to the polarization detector cells; and a signal detector that measures the laser source after being coupled to the polarization detector cells, which may be alkali cells. A single polarization cell may be used for nuclear magnetic resonance (NMR) by prepolarizing the nuclear spins of an analyte, encoding spectroscopic and/or spatial information, and detecting NMR signals from the analyte with a laser-based atomic magnetometer to form NMR spectra and/or magnetic resonance images (MRI). There is no need of a magnetic field or cryogenics in the detection step, as it is detected through the LBAM.

47 OTHER INSTRUMENTATION↗

Magnetic leverage effects in amorphous SmCo/CoAlZr heterostructures

Although magnetic heterostructures are the basis of many magnetic technologies, the mechanisms involved in magnetization reversals in such structures are not fully understood, especially in amorphous multilayers. Here, we report on the SmCo/CoAlZr system and exploit resonant magnetic x-ray scattering to probe the element specific magnetization reversals. When combined into a tri-layer structure, two different switching fields and reversal mechanisms are observed for the Sm and Co sub-lattices. We argue that the decoupling of the sub-lattices arises from the local distribution of atomic species within the amorphous matrix leading to a strong magnetic leverage effect and exchange pinning. The decoupling arises due to strong interactions between regions of high Co density which span the interface. The relatively sparse interactions between Sm and Co induce a localized pinning of the Co-rich areas, resulting in an exchange bias in minor loops and an enhanced coercivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synthesis and Characterization of Comb and Centipede Multigraft Copolymers P n BA- g -PS with High Molecular Weight Using Miniemulsion Polymerization

For this study, comb and centipede multigraft copolymers, poly(n-butyl acrylate)-g-polystyrene (PnBA-g-PS) with PnBA backbones and PS side chains, were synthesized via high-vacuum anionic polymerization and miniemulsion polymerization. Single-tailed and double-tailed PS macromonomers were synthesized by anionic polymerization and Steglich esterification. Subsequently, the copolymerization of each macromonomer and nBA was carried out in miniemulsion, and multigraft copolymers were obtained. The latex particles of multigraft copolymers were characterized using dynamic light scattering. The molecular weights of macromonomers and multigraft copolymers were analyzed by size exclusion chromatography. Moreover, the molecular weights and structures of macromonomers were investigated by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and 1H nuclear magnetic resonance spectroscopy. The weight contents of PS in comb and centipede multigraft copolymers were calculated by 1H nuclear magnetic resonance spectroscopy. The thermal properties of multigraft copolymers were characterized by thermogravimetric analysis and differential scanning calorimetry. The microphase separation of multigraft copolymers was observed by atomic force microscopy and transmission electronic microscopy. Rheological measurements showed that comb and centipede multigraft copolymers have elastic properties when the weight content of PS side chains is 26–32 wt %. Centipede multigraft copolymers possess better elastic properties than comb multigraft copolymers with the similar weight content of PS. In conclusion, these findings are similar to previous results on poly(isoprene-g-polystyrene) comb and centipede copolymers made by anionic polymerization.

36 MATERIALS SCIENCE↗

Paths from weak to strong coupling in NMR

J-coupled nuclear magnetic resonance (NMR) spectroscopy in the strong coupling regime at low magnetic field (10{sup -7} T <B<10{sup -3} T) is more complex than at high field (B>10{sup -3} T) and at ultralow field (B<10{sup -7} T). We show that several upper and lower boundaries B{sub i}{sup up} and B{sub i}{sup low} of the magnetic field B exist, where the complexity of J-coupled NMR spectra changes in terms of the number of lines. The index i=1,2,... for B{sub i}{sup up} at high field specifies the perturbation order of the dominating Zeeman interaction and for B{sub i}{sup low} at ultralow field the perturbation order of the dominating J-coupling interaction. Mathematical expressions for these boundaries are derived for the case of a J-coupled S-I{sub N} group where S and I are rare and abundant spins (1/2) and N counts the abundant spins I. The entire B-field range can further be delineated into two weak coupling regimes, one at high field with B{sub 2}{sup up}<B<B{sub 1}{sup up} (10{sup -3} T <B<10{sup 2} T), one at low field with B{sub 1}{sup low}<B<B{sub 2}{sup low}(10{sup -8} T <B<10{sup -7} T), and a strong coupling regime with B{sub 2}{sup low}<B<B{sub 2}{sup up} (10{sup -7} T <B<10{sup -3} T). The corresponding NMR spectra for the S-I{sub N} group are investigated by experiment and by simulation. In the strong coupling regime, the maximum number of lines is (N+1){sup 2}. In the weak coupling regime B{sub 1}{sup low}<B<B{sub 2}{sup low} at low field, symmetric multiplet structures group around the frequencies 0, J, (3/2)J, 2J, (5/2)J, etc. These spectra determine the structure of the S-I{sub N} group unambiguously and are in dual correspondence to the weakly coupled spectra at high field. High-resolution NMR spectroscopy at ultralow field may open up new ways for chemical analysis by small and mobile instruments with many applications in science and technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microwave and THz sensing using slab-pair-based metamaterials

Here in this work the sensing capability of an artificial magnetic metamaterial based on pairs of metal slabs is demonstrated, both theoretically and experimentally, in the microwave regime. The demonstration is based on transmission measurements and simulations monitoring the shift of the magnetic resonance frequency as one changes a thin dielectric layer placed between the slabs of the pairs. Strong dependence of the magnetic resonance frequency on both the permittivity and the thickness of the dielectric layer under detection was observed. The sensitivity to the dielectrics' permittivity (ε) is larger for dielectrics of low ε values, which makes the approach suitable for sensing organic materials also in the THz regime. Finally, the capability of our approach for THz sensing is also demonstrated through simulations.

36 MATERIALS SCIENCE↗

A novel electron gun for inline MRI-linac configurations

Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0.5 T magnet without capture efficiency reduction below the experimental value in zero field. In this range of linac displacements, the electron beam generated by the new gun geometry is more effectively injected into the linac in the presence of an external magnetic field, resulting in approximately 20% increase of the target current compared to the original gun geometry behavior at zero field. The new gun geometry can generate and accelerate electron beams in external magnetic fields without current loss for fields higher than 0.11 T. The new electron-gun geometry is robust enough to function in the fringe fields of the other two magnets with a target current loss of no more than 16% with respect to the current obtained with no external magnetic fields. Conclusions: In this work, a specially designed electron gun was presented which can operate in the presence of axisymmetric strong magnetic fringe fields of MRI magnets. Computer simulations show that the electron gun can produce high quality beams which can be injected into a straight through linac such as Varian 600C and accelerated with more efficiency in the presence of the external magnetic fields. Also, the new configuration allows linac displacements along the magnet axis in a range equal to the diameter of the imaging spherical volume of the magnet under consideration. The new electron gun-linac system can function in the fringe field of a MRI magnet if the field strength at the cathode position is higher than 0.11 T. The capture efficiency of the linac depends on the magnetic field strength and the field gradient. The higher the gradient the better the capture efficiency. The capture efficiency does not degrade more than 16%.

43 PARTICLE ACCELERATORS↗

New Window into the Human Body

Michael Vannier, MD, a former NASA engineer, recognized the similarity between NASA's computerized image processing technology and nuclear magnetic resonance. With technical assistance from Kennedy Space Center, he developed a computer program for Mallinckrodt Institute of Radiology enabling Nuclear Magnetic Resonance (NMR) to scan body tissue for earlier diagnoses. Dr. Vannier feels that "satellite imaging" has opened a new window into the human body.

Source record↗

The suppression effect of external magnetic field on the high-power microwave window multipactor phenomenon

To suppress the surface multipactor phenomenon and improve the transmitting power of the high-power microwave window, the application of external magnetic fields is theoretically analyzed and simulated. A Monte Carlo algorithm is used to track the secondary electron trajectories and study the multipactor scenario on the surface of a cylinder window. It is confirmed that over-resonant magnetic fields (an external magnetic field whose magnitude is slightly greater than that of a resonant magnetic field) will generate a compensating trajectory and collision, which can suppress the secondary electron avalanche. The optimal value of this external magnetic field that will avoid the multipactor phenomenon on cylinder windows is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estradiol associations with brain functional connectivity in postmenopausal women

Abstract Objective Previous studies have found that estrogens play a role in functional connectivity in the brain; however, little research has been done regarding how estradiol is associated with functional connectivity in postmenopausal women. The purpose of this study was to examine the relationship between estradiol and functional connectivity in postmenopausal women. Methods Structural and blood oxygenation level–dependent resting-state magnetic resonance imaging scans of 88 cognitively healthy postmenopausal individuals were obtained along with blood samples collected the same day as the magnetic resonance imaging to assess hormone levels. We generated connectivity values in CONN toolbox version 20.b, an SPM-based software. Results A regression analysis was run using estradiol level and regions of interest (ROI), including the hippocampus, parahippocampus, dorsolateral prefrontal cortex, and precuneus. Estradiol level was found to enhance parahippocampal gyrus anterior division left functional connectivity during ROI-to-ROI regression analysis. Estradiol enhanced functional connectivity between the parahippocampal gyrus anterior division left and the precuneus as well as the parahippocampal gyrus anterior division left and parahippocampal gyrus posterior division right. An exploratory analysis showed that years since the final menstrual period was related to enhanced connectivity between regions within the frontoparietal network. Conclusions These results illustrated the relationship between estradiol level and functional connectivity in postmenopausal women. They have implications for understanding how the functioning of the brain changes for individuals after menopause that may eventually lead to changes in cognition and behavior in older ages.

Obstetrics & Gynecology↗

Effect of magnetic perturbations on turbulence-flow dynamics at the L-H transition on DIII-D

Detailed 2D turbulence measurements from the DIII-D tokamak provide an explanation for how resonant magnetic perturbations (RMPs) raise the L-H power threshold P LH [P. Gohil et al. , Nucl. Fusion 51 , 103020 (2011)] in ITER-relevant, low rotation, ITER-similar-shape plasmas with favorable ion ∇ B direction. RMPs simultaneously raise the turbulence decorrelation rate Δ ω D and reduce the flow shear rate ω shear in the stationary L-mode state preceding the L-H transition, thereby disrupting the turbulence shear suppression mechanism. RMPs also reduce the Reynolds stress drive for poloidal flow, contributing to the reduction of ω shear . On the ~100 μ s timescale of the L-H transition, RMPs reduce Reynolds-stress-driven energy transfer from turbulence to flows by an order of magnitude, challenging the energy depletion theory for the L-H trigger mechanism. In contrast, non-resonant magnetic perturbations, which do not significantly affect P LH , do not affect Δ ω D and only slightly reduce ω shear and Reynolds-stress-driven energy transfer.<

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Open-Access, Low-Magnetic-Field MRI System for Lung Research

An open-access magnetic resonance imaging (MRI) system is being developed for use in research on orientational/gravitational effects on lung physiology and function. The open-access geometry enables study of human subjects in diverse orientations. This system operates at a magnetic flux density, considerably smaller than the flux densities of typical other MRI systems, that can be generated by resistive electromagnet coils (instead of the more-expensive superconducting coils of the other systems). The human subject inhales air containing He-3 or Xe-129 atoms, the nuclear spins of which have been polarized by use of a laser beam to obtain a magnetic resonance that enables high-resolution gas space imaging at the low applied magnetic field. The system includes a bi-planar, constant-current, four-coil electromagnet assembly and associated electronic circuitry to apply a static magnetic field of 6.5 mT throughout the lung volume; planar coils and associated circuitry to apply a pulsed magnetic-field-gradient for each spatial dimension; a single, detachable radio-frequency coil and associated circuitry for inducing and detecting MRI signals; a table for supporting a horizontal subject; and electromagnetic shielding surrounding the electromagnet coils.

Mair, Ross W.↗

MR-Guided Focused Ultrasound for the Treatment of Uterine Fibroids

Magnetic resonance imaging-guided focused ultrasound (MRgFUS) ablation of uterine fibroids provides a minimally invasive outpatient technique for targeting and treating symptomatic uterine fibroids. Magnetic resonance imaging provides a guidance platform that has high temporal and spatial resolution for guiding, as well as thermal monitoring of the procedure. The high-intensity focused ultrasound provides a mechanism for delivering large amounts of energy directly into the fibroid without causing detrimental effects to the nontarget tissues. Early and intermediate follow-up of patients treated with MRgFUS provided promising results on the efficacy of the technique for providing symptom relief to patients. As more long-term follow-up data are published, the efficacy of this technique can be compared to more invasive surgical and minimally invasive catheter treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗