Search NASA⌕ Search

SEARCH · Search NASA

Results for “Maintainability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Active Suspension Parameters Identification: An Algebraic Approach and its Application to Suspension Travel Control

The parameters of an active suspension need to be identified online, such that the suspension control system can be adapted to mechanical wear and load change. Recursive least squares and observer-based methods are frequently utilized to fulfill this purpose. However, they can yield slow parameter identification due to their asymptotic nature. We propose an algebraic identifier to estimate the parameters of an active suspension online, which does not maintain an asymptotic convergence phase. Simulation results demonstrate the effectiveness of the proposed algebraic approach.

Wang, Zejiang↗

The mechanisms, dynamics, and implications of self-sealing and CO 2 resistance in wellbore cements

Here, this study analyzes the dynamics and mechanisms of the interactions of carbonated brine with hydrated-Portland-cement; in particular, the study focuses on self-sealing, a process whereby hydrated-Portland cement reacts with carbonated brine to for silica and calcium carbonate in sufficient quantities to seal the flow pathway. The analysis is based on a comprehensive set of reactive-transport simulations that explore the complex coupled dynamics between the fluid flow and mineral reactions that underlie self-sealing, and it relies heavily on the synthesis of the extensive body of work on wellbore integrity that has been conducted over the past decade. The analysis explores a large chemical and mineralogical diversity and a wide range in physical conditions and flow regimes, attempting to assess the robustness of the analysis. Self-sealing conditions arise over a wide range in cement properties and reservoir conditions. Although some properties and conditions promote a stronger self-sealing response, self-sealing occurs for a wide range of Ca:Si ratios in cement and for various reservoir fluid compositions. Self-sealing conditions move along a wellbore proportional to the flux of the leaking carbonated brine, and the reaction zone spreads out proportional to the fluid velocity, where volumetric flux and velocity are related by porosity (flux = velocity * porosity). However, self-sealing conditions can be maintained in a specific section of a wellbore by controlling the pressure drive and/or effective wellbore permeability, which in turn can limit the flux and velocity of any leaking fluid. Finally, the phases produced by hydrating Portland cement represent a carbonic cement that will react with a carbonated brine to produce end products (calcium carbonate and silica) that can maintain integrity in the presence of carbonic acid. Lastly, the attributes that make hydrated Portland cement phases a carbonic cement are required for self-sealing.

58 GEOSCIENCES↗

High-performance SO 2 -depolarized electrolysis cell using advanced polymer electrolyte membranes

Three different proton conducting polymeric membrane materials (Nafion® 115, Nafion® 212, and sulfonated Diels-Alder polyphenylene [SDAPP]) were evaluated for use in SO 2 -depolarized electrolyzers for the production of hydrogen via the hybrid sulfur cycle. Their performance was measured using different water feed strategies to minimize overpotential losses while maintaining high product acid concentration. Both thin membranes (Nafion® 212 and SDAPP) showed performance superior to that of the thicker Nafion® 115. Here, the SDAPP membrane electrode assembly (MEA) performed well at higher acid concentrations, maintaining low ohmic and kinetic overpotentials. Finally, short-term (100-h) stability tests under constant current conditions showed minimal degradation for the SDAPP and Nafion® 212 MEAs. SDAPP MEA performance approached the targets needed to make the hybrid sulfur cycle a competitive process for hydrogen production (product acid concentration ≥65 wt% H 2 SO 4 at ≤ 0.6-V cell potential and ≥0.5 A-cm –2 current density).

08 HYDROGEN↗

Optimization of key energy and performance metrics for drug product manufacturing

During the development of pharmaceutical manufacturing processes, detailed systems-based analysis and optimization are required to control and regulate critical quality attributes within specific ranges, to maintain product performance. As discussions on carbon footprint, sustainability, and energy efficiency are gaining prominence, the development and utilization of these concepts in pharmaceutical manufacturing are seldom reported, which limits the potential of pharmaceutical industry in maximizing key energy and performance metrics. Based on an integrated modeling and techno-economic analysis framework previously developed by the authors, this study presents the development of a combined sensitivity analysis and optimization approach to minimize energy consumption while maintaining product quality and meeting operational constraints in a pharmaceutical process. The optimal input process conditions identified were validated against experiments and good agreement resulted between simulated and experimental data. Here, the results also allowed for a comparison of the capital and operational costs for batch and continuous manufacturing schemes under nominal and optimized conditions. Using the nominal batch operations as a basis, the optimized batch operation results in a 71.7% reduction of energy consumption, whereas the optimized continuous case results in an energy saving of 83.3%.

59 BASIC BIOLOGICAL SCIENCES↗

Simple Carotid-Sparing Intensity-Modulated Radiotherapy Technique and Preliminary Experience for T1-2 Glottic Cancer

Purpose: To investigate the dosimetry and feasibility of carotid-sparing intensity-modulated radiotherapy (IMRT) for early glottic cancer and to report preliminary clinical experience. Methods and Materials: Digital Imaging and Communications in Medicine radiotherapy (DICOM-RT) datasets from 6 T1-2 conventionally treated glottic cancer patients were used to create both conventional IMRT plans. We developed a simplified IMRT planning algorithm with three fields and limited segments. Conventional and IMRT plans were compared using generalized equivalent uniform dose and dose-volume parameters for in-field carotid arteries, target volumes, and organs at risk. We have treated 11 patients with this simplified IMRT technique. Results: Intensity-modulated radiotherapy consistently reduced radiation dose to the carotid arteries (p < 0.05) while maintaining the clinical target volume coverage. With conventional planning, median carotid V35, V50, and V63 were 100%, 100%, and 69.0%, respectively. With IMRT planning these decreased to 2%, 0%, and 0%, respectively (p < 0.01). Radiation planning and treatment times were similar for conventional radiotherapy and IMRT. Treatment results have been excellent thus far. Conclusions: Intensity-modulated radiotherapy significantly reduced unnecessary radiation dose to the carotid arteries compared with conventional lateral fields while maintaining clinical target volume coverage. Further experience and longer follow-up will be required to demonstrate outcomes for cancer control and carotid artery effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Weekly Replanning for Intensity-Modulated Radiotherapy of Cervix Cancer

Purpose: The adoption of intensity-modulated radiotherapy (IMRT) to treat cervical malignancies has been limited in part by complex organ and tumor motion during treatment. This study explores the limits of a highly adaptive, small-margin treatment scenario to accommodate this motion. In addition, the dosimetric consequences of organ and tumor motion are modeled using a combination of deformable registration and fractional dose accumulation techniques. Methods and Materials: Thirty-three cervix cancer patients had target volumes and organs-at-risk contoured on fused, pretreatment magnetic resonance-computed tomography images and weekly magnetic resonance scans taken during treatment. The dosimetric impact of interfraction organ and target motion was compared for two hypothetical treatment scenarios: a 3-mm margin plan with no replanning, and a 3-mm margin plan with an automated replan performed on the updated weekly patient geometry. Results: Of the 33 patients, 24 (73%) met clinically acceptable target coverage (98% of the clinical target volume receiving at least 95% of the prescription dose) using the 3-mm margin plan without replanning. The range in dose to 98% of the clinical target volume across all patients was 7.9% of the prescription dose if no replanning was performed. After weekly replanning, this range was tightened to 2.6% of the prescription dose and all patients met clinically acceptable target coverage while maintaining organ-at-risk dose sparing. Conclusions: The dosimetric impact of anatomical motion underscores the challenges of applying IMRT to treat cervix cancer. An appropriate adaptive strategy can ensure target coverage for small-margin IMRT treatments and maintain favorable organ-at-risk dose sparing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-Dose Neoadjuvant External Beam Radiation Therapy for Soft Tissue Sarcoma

Purpose: For soft tissue sarcoma, neoadjuvant external beam radiation therapy (EBRT) to 50 Gy has the same local control (LC) and overall survival as postoperative radiation therapy (PORT) to 60 Gy, but with increased wound complications. We examined whether low-dose neoadjuvant EBRT would decrease acute toxicity while maintaining LC. Methods and Materials: From 1971 to 2008, 1,765 patients with nonmetastatic soft tissue sarcoma were treated with radiation therapy at Massachusetts General Hospital. We identified 42 patients treated with low-dose neoadjuvant EBRT (median, 20 Gy; range, 16-26) followed by surgical resection and PORT. PORT included EBRT (25 patients; median, 40 Gy; range, 20-56.2), brachytherapy (13 patients; median, 42 Gy; range, 26-50), and intraoperative radiation therapy (IORT) (4 patients; median, 12.5 Gy; range, 8-20). The median total dose was 63.3 Gy (range, 28-78.4). Results: Median follow-up was 36 months (range, 4-318). Severe acute wound complications were reported in 15 patients (36%) and correlated to PORT technique (16% EBRT, 69% brachytherapy, 50% IORT, p = 0.004). The 5-year LC was 73% and correlated to PORT technique (68% EBRT, 100% brachytherapy, 50% IORT, p = 0.03) and histology (p = 0.05), with a trend to improvement if >60 Gy (p = 0.10). The 5-year overall survival was 65% and correlated to extent of resection (p < 0.001) and margin status (p < 0.001). Conclusions: Despite using low-dose neoadjuvant EBRT, we report a high rate of severe acute wound complications that was strongly associated with brachytherapy. Modification of the brachytherapy technique may decrease acute toxicity while maintaining excellent local control. Further study must be conducted before recommending broader application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Insulin-Like Growth Factor-1 Preserves Salivary Gland Function After Fractionated Radiation

Purpose: Radiotherapy for head-and-neck cancer consists of fractionated radiation treatments that cause significant damage to salivary glands leading to chronic salivary gland dysfunction with only limited prevention and treatment options currently available. This study examines the feasibility of IGF-1 in preserving salivary gland function following a fractionated radiation treatment regimen in a pre-clinical model. Methods and Materials: Mice were exposed to fractionated radiation, and salivary gland function and histological analyses of structure, apoptosis, and proliferation were evaluated. Results: In this study, we report that treatment with fractionated doses of radiation results in a significant level of apoptotic cells in FVB mice after each fraction, which is significantly decreased in transgenic mice expressing a constitutively active mutant of Akt1 (myr-Akt1). Salivary gland function is significantly reduced in FVB mice exposed to fractionated radiation; however, myr-Akt1 transgenic mice maintain salivary function under the same treatment conditions. Injection into FVB mice of recombinant insulin-like growth factor-1 (IGF-1), which activates endogenous Akt, suppressed acute apoptosis and preserved salivary gland function after fractionated doses of radiation 30 to 90 days after treatment. FVB mice exposed to fractionated radiation had significantly lower levels of proliferating cell nuclear antigen-positive salivary acinar cells 90 days after treatment, which correlated with a chronic loss of function. In contrast, FVB mice injected with IGF-1 before each radiation treatment exhibited acinar cell proliferation rates similar to those of untreated controls. Conclusion: These studies suggest that activation of IGF-1-mediated pathways before head-and-neck radiation could modulate radiation-induced salivary gland dysfunction and maintain glandular homeostasis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fibroblast Growth Factor 2-A Predictor of Outcome for Patients Irradiated for Stage II-III Non-Small-Cell Lung Cancer

Purpose: The prognostic value of the tumor cell expression of the fibroblast growth factor 2 (FGF-2) in patients with non-small-cell lung cancer (NSCLC) is unclear. The present study investigated the effect of tumor cell expression of FGF-2 on the outcome of 60 patients irradiated for Stage II-III NSCLC. Methods and Materials: The effect of FGF-2 expression and 13 additional factors on locoregional control (LRC), metastasis-free survival (MFS), and overall survival (OS) were retrospectively evaluated. These additional factors included age, gender, Karnofsky performance status, histologic type, histologic grade, T and N category, American Joint Committee on Cancer stage, surgery, chemotherapy, pack-years, smoking during radiotherapy, and hemoglobin during radiotherapy. Locoregional failure was identified by endoscopy or computed tomography. Univariate analyses were performed with the Kaplan-Meier method and the Wilcoxon test and multivariate analyses with the Cox proportional hazard model. Results: On univariate analysis, improved LRC was associated with surgery (p = .017), greater hemoglobin levels (p = .036), and FGF-2 negativity (p <.001). On multivariate analysis of LRC, surgery (relative risk [RR], 2.44; p = .037), and FGF-2 expression (RR, 5.06; p <.001) maintained significance. On univariate analysis, improved MFS was associated with squamous cell carcinoma (p = .020), greater hemoglobin levels (p = .007), and FGF-2 negativity (p = .001). On multivariate analysis of MFS, the hemoglobin levels (RR, 2.65; p = .019) and FGF-2 expression (RR, 3.05; p = .004) were significant. On univariate analysis, improved OS was associated with a lower N category (p = .048), greater hemoglobin levels (p <.001), and FGF-2 negativity (p <.001). On multivariate analysis of OS, greater hemoglobin levels (RR, 4.62; p = .002) and FGF-2 expression (RR, 3.25; p = .002) maintained significance. Conclusions: Tumor cell expression of FGF-2 appeared to be an independent negative predictor of LRC, MFS, and OS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Comparison of Combined Intensity-Modulated Radiotherapy (IMRT) and Proton Therapy Versus IMRT Alone for Pelvic and Para-Aortic Radiotherapy in Gynecologic Malignancies

Purpose: To perform a dosimetric comparison of intensity-modulated radiotherapy (IMRT), passive scattering proton therapy (PSPT), and intensity-modulated proton therapy (IMPT) to the para-aortic (PA) nodal region in women with locally advanced gynecologic malignancies. Methods and Materials: The CT treatment planning scans of 10 consecutive patients treated with IMRT to the pelvis and PA nodes were identified. The clinical target volume was defined by the primary tumor for patients with cervical cancer and by the vagina and paravaginal tissues for patients with endometrial cancer, in addition to the regional lymph nodes. The IMRT, PSPT, and IMPT plans were generated using the Eclipse Treatment Planning System and were analyzed for various dosimetric endpoints. Two groups of treatment plans including proton radiotherapy were created: IMRT to pelvic nodes with PSPT to PA nodes (PSPT/IMRT), and IMRT to pelvic nodes with IMPT to PA nodes (IMPT/IMRT). The IMRT and proton RT plans were optimized to deliver 50.4 Gy or Gy (relative biologic effectiveness [RBE)), respectively. Dose-volume histograms were analyzed for all of the organs at risk. The paired t test was used for all statistical comparison. Results: The small-bowel V{sub 20}, V{sub 30}, V{sub 35}, andV{sub 40} were reduced in PSPT/IMRT by 11%, 18%, 27%, and 43%, respectively (p < 0.01). Treatment with IMPT/IMRT demonstrated a 32% decrease in the small-bowel V{sub 20}. Treatment with PSPT/IMRT showed statistically significant reductions in the body V{sub 5-20}; IMPT/IMRT showed reductions in the body V{sub 5-15}. The dose received by half of both kidneys was reduced by PSPT/IMRT and by IMPT/IMRT. All plans maintained excellent coverage of the planning target volume. Conclusions: Compared with IMRT alone, PSPT/IMRT and IMPT/IMRT had a statistically significant decrease in dose to the small and large bowel and kidneys, while maintaining excellent planning target volume coverage. Further studies should be done to correlate the clinical significance of these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigating the FLASH Effect in a Rat Brain Organotypic Model With a Novel High-Energy Electron Beam

Ultrahigh dose rate (FLASH) radiation therapy is reported to reduce normal tissue toxicity while maintaining tumor control; however, mechanism(s) remain obscure. To study FLASH mechanisms in brain tissue, we developed a novel experimental platform featuring a specialized high-energy electron linear accelerator, High Intensity Gamma Ray Source (HIGS), paired with an organotypic ex vivo brain metastasis model. We varied interpulse spacing to modulate the mean dose rate (MDR) of our unique 35 MeV electron beam, while maintaining extremely high instantaneous dose rate (IDR). We characterized dosimetry and targeting accuracy of the FLASH beam with film dosimetry. We combined this FLASH beam with an organotypic rat brain slice/breast carcinoma coculture model of brain metastasis to assess effects on normal and neoplastic tissues. Live-cell and bioluminescence imaging demonstrated cancer cell growth effects, whereas normal tissue responses and immune activation were assessed using live-cell imaging, cytokine profiles, and confocal microscopy. Here, we performed comparison experiments with 20 MeV electrons from a Varian clinical linear accelerator (VCLA) using conventional dose rates. The highest IDR of the FLASH beam to date was 20.7 ± 0.6 MGy/s, with maximum MDR of 20.7 MGy/s delivered in 1 pulse of 1 µs duration. Beam targeting was accurate to <1 mm and reproducible. HIGS-FLASH and VCLA dose rates equivalently decreased cancer cell growth. HIGS-FLASH irradiation significantly increased tumor necrosis factor α and fractalkine levels and confocal microscopy revealed distinct changes in microglial morphology slices suggesting microglia activation. Our novel experimental platform produces extremely high dose rates and rapid normal/neoplastic tissue readouts for mechanistic research into the effects of FLASH radiation in the brain. HIGS-FLASH irradiation induces comparable cancer cell growth inhibition but differential effects on cytokines and microglial morphology, suggesting that acute innate immune responses may be involved in FLASH normal tissue effects in the brain.

Kay, Tyler V. [Duke University, Durham, NC (United↗

Asynchronous aging and turnover of human circulating and tissue-resident memory T cells across sites

Memory T cells are maintained in tissues as circulating effector-memory (T EM ) and tissue-resident (T RM ) populations for protective immunity, though the role of site and subset in memory persistence remains undefined. Here, in this work, we investigated age-associated dynamics of human T cells in lymphoid organs, mucosal sites, and blood over 10 decades of life using retrospective radiocarbon ( 14 C) birth dating, along with cellular, transcriptome, and epigenetic profiling. Memory T cells across peripheral sites exhibited continuous turnover with mean lifespans of 1–2 years, while the spleen contained longer-lived T cells. Over age, T EM cells expressed senescent markers and a GZMK transcriptional signature, while T RM cells maintained site-specific resident phenotypes without exhibiting features of senescence. Both T EM and T RM cells showed age-associated DNA hypomethylation, though T RM cells exhibited more epigenetically regulated genes. Together, our findings reveal asynchronous aging of human memory T cells by subset and site, as well as persistence of T RM cells without immunosenescence.

T cells↗

Continuous recovery of high-purity Kraft lignin from black liquor via simultaneous, liquid-phase acidification and purification

Here, a key advantage of the Sequential Liquid-Lignin Recovery and Purification (SLRP) process for the recovery of lignin from Kraft black liquor is the precipitation of a solvated, “liquid-lignin” phase (vs. the typical solid) during the CO 2 acidification step. Here, we have discovered that this lignin can also be maintained in a solvated state during the H 2 SO 4 acidification step if aqueous acetic acid from the Aqueous Lignin Purification with Hot Agents (ALPHA) process is incorporated into the H 2 SO 4 solution. As the liquid-lignin is converted from its salt form at pH = 9.5 to its acid form at pH = 2.5, the lignin initially solvated with water becomes solvated and thus liquefied with the organic–water solution. Maintaining the lignin in a solvated liquid state has two advantages: (1) the entire SLRP + ALPHA process, from starting black liquor to final lignin product, can be operated continuously; and (2) mass transfer of metals impurities out of the liquid-lignin phase is significantly enhanced, resulting in both a cleaner Kraft lignin product (~2000 ppm Na and 0.5-1.0 % ash) and reduced water washing.

09 BIOMASS FUELS↗

Energy-efficient cooperative resource allocation and task scheduling for Internet of Things environments

Offloading Internet of Things (IoT) tasks to the cloud for further processing might not always lead to an optimal execution time, particularly in situations such as resource contention, under-provisioning, over-provisioning, and fragmentation. In addition, dynamically optimizing the number of Virtual Machines (VMs) for resource scheduling in order to meet application requirements remains a major research challenge. Further, existing resource scheduling algorithms focus primarily on minimizing operational costs while maximizing resource sharing and utilization. Considering energy utilization as part of the resource allocation and scheduling process as an optimization objective for maintaining load balancing has often been neglected. To address these challenges and more, we propose a cooperative energy-aware resource allocation and scheduling strategy based on a Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS) multi-criteria decision-making method. Here we used the Grid Workloads Archive dataset to evaluate our proposed approach named TOPREAL. Experimental results with respect to the allocation of VM resources when considering processing a large segment of tasks indicate that TOPREAL outperforms existing algorithms in terms of energy savings, with an average improvement of 40.25%, while maintaining an average improvement of 16.21% when it comes to execution time. Results also demonstrate that our method can save an average of 78.06 processing hours and 63,215kJ of energy when compared to existing scheduling algorithms. These results demonstrate the effectiveness of our proposed model and the viability of using multi-criteria decision-making techniques such as TOPSIS to solve the resource allocation and scheduling problem in edge environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robust constrained tension control for high-precision roll-to-roll processes

Tension control is critical for maintaining good product quality in most roll-to-roll (R2R) production systems. Previous work has primarily focused on improving the disturbance rejection performance of tension controllers. Here, a robust linear parameter-varying model predictive control (LPV-MPC) scheme is designed to enhance the tension tracking performance of a pilot R2R system for deposition of materials used in flexible thin film applications. The performance of a tension controller may degrade due to disturbances associated with model uncertainties and the slowly-changing dynamics in R2R systems. We introduce a method that separately treats these two sources of disturbance. The controller utilizes an incremental model to eliminate the errors caused by the mismatch between the nominal model and the actual system. A tube-based MPC formulation combined with scheduled parameters adequately updates models and corrects for the time-varying dynamics. Constraints on the rated motor torque are incorporated in the MPC to maintain the controller reliability and avoid machine failures. We illustrate the operation of our control algorithm through simulation of an actual R2R system. The controller outperforms the benchmarks in terms of fast transient response and offset-free tension tracking. Furthermore, it also demonstrates immunity from variations due to parametric uncertainties.

42 ENGINEERING↗

Implementation of a hybrid particle code with a PIC description in r–z and a gridless description in ϕ into OSIRIS

For many plasma physics problems, three-dimensional and kinetic effects are very important. However, such simulations are very computationally intensive. Fortunately, there is a class of problems for which there is nearly azimuthal symmetry and the dominant three-dimensional physics is captured by the inclusion of only a few azimuthal harmonics. Recently, it was proposed [1] to model one such problem, laser wakefield acceleration, by expanding the fields and currents in azimuthal harmonics and truncating the expansion. The complex amplitudes of the fundamental and first harmonic for the fields were solved on an r–z grid and a procedure for calculating the complex current amplitudes for each particle based on its motion in Cartesian geometry was presented using a Marder's correction to maintain the validity of Gauss's law. In this paper, we describe an implementation of this algorithm into OSIRIS using a rigorous charge conserving current deposition method to maintain the validity of Gauss's law. We show that this algorithm is a hybrid method which uses a particles-in-cell description in r–z and a gridless description in ϕ. We include the ability to keep an arbitrary number of harmonics and higher order particle shapes. Examples for laser wakefield acceleration, plasma wakefield acceleration, and beam loading are also presented and directions for future work are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using hybrid implicit Monte Carlo diffusion to simulate gray radiation hydrodynamics

This work describes how to couple a hybrid Implicit Monte Carlo Diffusion (HIMCD) method with a Lagrangian hydrodynamics code to evaluate the coupled radiation hydrodynamics equations. This HIMCD method dynamically applies Implicit Monte Carlo Diffusion (IMD) [1] to regions of a problem that are opaque and diffusive while applying standard Implicit Monte Carlo (IMC) [2] to regions where the diffusion approximation is invalid. We show that this method significantly improves the computational efficiency as compared to a standard IMC/Hydrodynamics solver, when optically thick diffusive material is present, while maintaining accuracy. Two test cases are used to demonstrate the accuracy and performance of HIMCD as compared to IMC and IMD. The first is the Lowrie semi-analytic diffusive shock [3]. The second is a simple test case where the source radiation streams through optically thin material and heats a thick diffusive region of material causing it to rapidly expand. We found that HIMCD proves to be accurate, robust, and computationally efficient for these test problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗