Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Applications of XPS in the characterization of Battery materials

In this study, technological development requires reliable power sources where energy storage devices are emerging as a critical component. Wide range of energy storage devices, Redox-flow batteries (RFB), Lithium ion based batteries (LIB), and Lithium-sulfur (LSB) batteries are being developed for various applications ranging from grid-scale level storage to mobile electronics. Material complexities associated with these energy storage devices with unique electrochemistry are formidable challenge which needs to be address for transformative progress in this field. X-ray photoelectron spectroscopy (XPS) - a powerful surface analysis tool - has been widely used to study these energy storage materials because of its ability to identify, quantify and image the chemical distribution of redox active species. However, accessing the deeply buried solid-electrolyte interfaces (which dictates the performance of energy storage devices) has been a challenge in XPS usage. Herein we report our recent efforts to utilize the XPS to gain deep insight about these interfaces under realistic conditions with varying electrochemistry involving RFB, LIB and LSB.

25 ENERGY STORAGE↗

Experimental characterization of magnetic materials for the magnetic shielding of cryomodules in particle accelerators

The magnetic properties of two important passive magnetic shielding materials (A4K and Amumetal) for accelerator applications, subjected to various processing and heat treatment conditions are studied comprehensively over a wide range of temperatures: from cryogenic to room temperature. Furthermore, we analyze the effect of processing on the extent of degradation of the magnetic properties of both materials and investigate the possibility of restoring these properties by re-annealing.

43 PARTICLE ACCELERATORS↗

SU-E-J-210: Characterizing Tissue Equivalent Materials for the Development of a Dual MRI-CT Heterogeneous Anthropomorphic Phantom Designed Specifically for MRI Guided Radiotherapy Systems

Purpose: MRI guided radiotherapy (MRIgRT) is an emerging technology which will eventually require a proficient quality auditing system. Due to different principles in which MR and CT acquire images, there is a need for a multi-imaging-modality, end-to-end QA phantom for MRIgRT. The purpose of this study is to identify lung, soft tissue, and tumor equivalent substitutes that share similar human-like CT and MR properties (i.e. Hounsfield units and relaxation times). Methods: Materials of interested such as common CT QA phantom materials, and other proprietary gels/silicones from Polytek, SmoothOn, and CompositeOne were first scanned on a GE 1.5T Signa HDxT MR. Materials that could be seen on both T1-weighted and T2-weighted images were then scanned on a GE Lightspeed RT16 CT simulator and a GE Discovery 750HD CT scanner and their HU values were then measured. The materials with matching HU values of lung (−500 to −700HU), muscle (+40HU) and soft tissue (+100 to +300HU) were further scanned on GE 1.5T Signa HDx to measure their T1 and T2 relaxation times from varying parameters of TI and TE. Results: Materials that could be visualized on T1-weighted and T2-weighted images from a 1.5T MR unit and had an appropriate average CT number, −650, −685, 46,169, and 168 HUs were: compressed cork saturated with water, Polytek Platsil™ Gel-00 combined with mini styrofoam balls, radiotherapy bolus material, SmoothOn Dragon-Skin™ and SmoothOn Ecoflex™, respectively. Conclusion: Post processing analysis is currently being performed to accurately map T1 and T2 values for each material tested. From previous MR visualization and CT examinations it is expected that Dragon-Skin™, Ecoflex™ and bolus will have values consistent with tissue and tumor substitutes. We also expect compressed cork statured with water, and Polytek™-styrofoam combination to have approximate T1 and T2 values suitable for lung-equivalent materials.

60 APPLIED LIFE SCIENCES↗

Raman Spectroscopy Characterization of Nuclear Materials and Soot from High Explosives

Vibrational and luminescence spectroscopy were used in the investigation of U and Pu-bearing compounds and soot from high explosives testing. Key spectroscopic signatures of UF4 and its hydrates, PuO 2 , and soot from different explosives will be presented. The United States Government retains and the publisher, by accepting this article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, worldwide license to publish or reproduce the published form of this work, or allow others to do so, for United States Government purposes.

Villa-Aleman, Eliel↗

Characterization of Solid Materials Responsible for the Partial Blockage of the 3H Evaporator-to-Mercury Removal Tank Drain Line

In April 2015, part of the solid wet cake material responsible for partially obstructing of the drain line from the Mercury Removal Tank (MRT) on the 3H Evaporator was delivered to SRNL for analysis. The desired analytical goal was to identify the chemical components of the material responsible for the partial blockage and if possible, infer possible formation mechanisms and the best way of removing the consolidated clogging solid material from the drain line.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Various Materials Using Refractometry

Refractive index (RI) is a fundamental physical property of a material. However, the RI values of several binders, including nitroplasticizer (NP), Estanes, and KelF/FK 800, are not available in literature. Further, their temperature dependencies are undocumented either. In this study, we have developed a set of methodologies to accurately and effectively determine the RIs of these binder materials between 20 and 70°C. The RIs of these binders without aging show linear correlations with temperature, as shown in the figure below. Among these materials, Estane 5714 has the highest RI whereas FK800 has the lowest RI. As materials age, the changes in their RIs are different, suggesting different aging behavior of these binders upon heating. Typically, NP and Estane degraded through hydrolysis give lower RIs than the baseline materials. However, when KelF/FK800 materials thermally age, their RIs increase. Overall, this study demonstrates refractometry is a sensitive technique to detect aging signs in various materials of interest.

36 MATERIALS SCIENCE↗

Characterization of Covetic Materials for Process Control. Final CRADA report

GDC Industries LLC has been performing process research on covetic materials since its formation in February 2015. With assistance from DOE and the Air Force via SBIR projects, GDC focused on the enhancement of aluminum alloys to covetics to replicate a previously reported electrical conductivity of about 67% IACS (International Annealed Copper Standard). GDC has established a joint development agreement with General Cable Corporation, wherein General Cable agreed to perform numerous extrusions of as cast covetics and subsequent tensile and electrical conductivity tests on the resultant wire. Covetics conversion was proven but the significant improvement is yet to be replicated. To control the experiments towards enhanced process control, a series of designed experiments was created by an expert in process control from the automotive industry. Six process variables were identified and a designed experiment matrix requiring 18 independent conversions was created at GDC. The result of those designed experiments has now allowed GDC to focus on two process variables, namely, residence time and DC current in the conversions with the other four variable held constant. While this work is useful in replicating the earlier enhancements, GDC feels it will not be sufficient for the necessary process knowhow for scale up required by industry as GDC still does not have a direct correlation of the process variables to the actual carbon in the finished covetics. Since 2015, GDC has been aware of the capabilities existing at Argonne National Laboratory for performing carbon analysis that exceeds the precision commonly available to Industry. GDC and ANL submitted a proposal in response to the DOE-EERE – Small Business Vouchers Pliot Program announcement and the proposal was selected for funding. GDC will melt-process covetic aluminum samples following their design of experiment criteria and have the as-casted samples extruded by their partner, General Cable. Argonne will measure the conductivity, analyze carbon content, perform X-ray diffraction, and examine the microstructural features of the samples. Careful process variable measurements will be recorded by each party such that correlations can be developed indicating process parameters that yield the best carbon concentration in covetics.

36 MATERIALS SCIENCE↗

SR19016 - Characterization of AM Materials for SRTE Service

This project addresses several issues and challenges for the use of AM produced components in the tritium facility. It will evaluate the effect of low level hydrogen and tritium exposure on the mechanical and chemical characteristics of Arcam A2X Electron Beam Powder Bed Fusion Produced (EPBF) Ti-6AI-4V by printing tensile samples and testing them in the as printed, machined, and hydrogen exposed conditions. Hydrogen uptake will be measured using an Eltra Hydrogen-Oxygen- Nitrogen analyzer. Hydride response will be measured using a Seiffert's apparatus and determining the effects of various surface treatments on the hydriding susceptibility. Tools, fixtures, and other objects will be deigned and printed for use in the AM lab and tritum facility and for other groups that support the tiritum mission.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Selection and Characterization of Surrogate Material for Developing Zr Barrier Coatings for Uranium Nitride Particles

In support of UC 1-x N x fuel kernels (~ 800 micrometer diameter) development work ongoing at Oak Ridge national laboratory (ORNL), where the fuel kernels will be embedded inside a possible zirconium based matrix, Argonne National Laboratory (ANL) is contributing to help develop a robust metal diffusion barrier coating. Zirconium nitride (ZrN) and Zirconium oxide (ZrO2) were selected as possible diffusion barrier candidates, and the atomic layer deposition (ALD) has been chosen as a candidate technology to deposit the film. Development of such a barrier coating with the ALD process entails significant number of trials to study relevant parameters. Therefore, to prevent needless wastage, instead of coating directly over fuel kernels, a surrogate candidate with similar dimensions and physical properties were been selected and coated to develop the diffusion barrier coating.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Real-Time, In-pile Creep Test Rigs for Characterizing the Structural Materials of Nuclear Components

New and improved materials are being considered for supporting both existing and next-generation nuclear reactors. Reactor materials can significantly degrade with time, thus limiting or altering their properties in harsh reactor environments. To accurately understand such material degradation, real-time data obtained under prototypic irradiation conditions are required. In particular, understanding the creep behavior of materials exposed to irradiation and elevated temperatures is essential for safety concern evaluations. To provide these capabilities, Idaho National Laboratory (INL)’s High Temperature Test Laboratory (HTTL) developed several instrumented test rigs for obtaining real-time data from specimens in well-controlled pressurized-water reactor (PWR) coolant conditions at the Materials Test Reactor. This technical report focuses on INL’s efforts to evaluate and enhance the former creep test rig prototype that relied on linear variable differential transformers in laboratory settings. Specifically, the test rig can detect changes in the length of creep specimens, which is useful for measuring thermal expansion and creep deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗