Search NASA⌕ Search

SEARCH · Search NASA

Results for “Method development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Multiple stable isotope characterization as a forensic tool to distinguish acid scavenger samples

Acid scavengers are frequently used as stabilizer compounds in a variety of applications. When used to stabilize volatile compounds such as nerve agents, the lower volatility and higher stability of acid scavengers make them more persistent in a post-event forensic setting. We are employing compound-specific stable isotope analysis of the carbon, nitrogen, and hydrogen components of three acid scavenging compounds (N,N-diethylaniline, tributylamine, and triethylamine) as a tool for distinguishing between different samples of the stabilizers. Combined analysis of three stable isotopes in these samples improves the technique’s resolving potential, enhancing sample matching capabilities. The compound specific methods developed here can be applied to instances where these compounds are not pure, such as when mixed with an agent or when found as a residue at an event site. Effective sample matching can be crucial for linking compounds at multiple event sites or linking a supply inventory to an event.

08 HYDROGEN↗

ADPase activity of recombinantly expressed thermotolerant ATPases may be caused by copurification of adenylate kinase of Escherichia coli

Except for apyrases, ATPases generally target only the {gamma}-phosphate of a nucleotide. Some non-apyrase ATPases from thermophilic microorganisms are reported to hydrolyze ADP as well as ATP, which has been described as a novel property of the ATPases from extreme thermophiles. Here, we describe an apparent ADP hydrolysis by highly purified preparations of the AAA+ ATPase NtrC1 from an extremely thermophilic bacterium, Aquifex aeolicus. This activity is actually a combination of the activities of the ATPase and contaminating adenylate kinase (AK) from Escherichia coli, which is present at 1/10 000 of the level of the ATPase. AK catalyzes conversion of two molecules of ADP into AMP and ATP, the latter being a substrate for the ATPase. We raise concern that the observed thermotolerance of E. coli AK and its copurification with thermostable proteins by commonly used methods may confound studies of enzymes that specifically catalyze hydrolysis of nucleoside diphosphates or triphosphates. For example, contamination with E. coli AK may be responsible for reported ADPase activities of the ATPase chaperonins from Pyrococcus furiosus, Pyrococcus horikoshii, Methanococcus jannaschii and Thermoplasma acidophilum; the ATP/ADP-dependent DNA ligases from Aeropyrum pernix K1 and Staphylothermus marinus; or the reported ATP-dependent activities of ADP-dependent phosphofructokinase of P. furiosus. Purification methods developed to separate NtrC1 ATPase from AK also revealed two distinct forms of the ATPase. One is tightly bound to ADP or GDP and able to bind to Q but not S ion exchange matrixes. The other is nucleotide-free and binds to both Q and S ion exchange matrixes.

59 BASIC BIOLOGICAL SCIENCES↗

Hydrogeology, chemical and microbial activity measurement through deep permafrost

Little is known about hydrogeochemical conditions beneath thick permafrost, particularly in fractured crystalline rock, due to difficulty in accessing this environment. The purpose of this investigation was to develop methods to obtain physical, chemical, and microbial information about the subpermafrost environment from a surface-drilled borehole. Using a U-tube, gas and water samples were collected, along with temperature, pressure, and hydraulic conductivity measurements, 420 m below ground surface, within a 535 m long, angled borehole at High Lake, Nunavut, Canada, in an area with 460-m-thick permafrost. Piezometric head was well above the base of the permafrost, near land surface. Initial water samples were contaminated with drill fluid, with later samples <40% drill fluid. The salinity of the non-drill fluid component was <20,000 mg/L, had a Ca/Na ratio above 1, with {delta}{sup 18}O values {approx}5{per_thousand} lower than the local surface water. The fluid isotopic composition was affected by the permafrost-formation process. Nonbacteriogenic CH{sub 4} was present and the sample location was within methane hydrate stability field. Sampling lines froze before uncontaminated samples from the subpermafrost environment could be obtained, yet the available time to obtain water samples was extended compared to previous studies. Temperature measurements collected from a distributed temperature sensor indicated that this issue can be overcome easily in the future. The lack of methanogenic CH{sub 4} is consistent with the high sulfate concentrations observed in cores. The combined surface-drilled borehole/U-tube approach can provide a large amount of physical, chemical, and microbial data from the subpermafrost environment with few, controllable, sources of contamination.

54 ENVIRONMENTAL SCIENCES↗

Estimating Persistent Mass Flux of Volatile Contaminants from the Vadose Zone to Ground Water

Contaminants may persist for long time periods within low permeability portions of the vadose zone where they cannot be effectively treated and are a potential continuing source of contamination to groundwater. Setting appropriate vadose zone remediation goals requires evaluating these persistent sources in terms of their impact on meeting groundwater remediation goals. One-dimensional approaches for estimating transport of volatile contaminants in the vadose zone are considered and compared to a one-dimensional flux-continuity-based assessment of vapor-phase contaminant movement from the vadose zone to the groundwater. The flux-continuity-based assessment demonstrates that the ability of the groundwater to move contaminant away from the water table controls the vapor-phase mass flux from the vadose zone across the water table. Limitations of the one-dimensional approaches are then discussed with respect to the need for further method development and application of two- or three-dimensional numerical modeling. The carbon tetrachloride (CT) plume at the U.S. Department of Energy Hanford Site is used as an example of a site where persistent vadose zone contamination needs to be considered in the context of groundwater remediation.

54 ENVIRONMENTAL SCIENCES↗

Determination of deformations as a result of seismic loadings on two-dimensional reinforced concrete frame via terrestrial laser scanners

Parallel to the technological developments, methods of defining locational data are changing. Laser scanners bring new advantages to engineering measurements and geodesy. Terrestrial laser scanners, which have previously been used in map engineering, have become an alternative method of measurement, especially for terrestrial applications. A common characteristic of deformation measurements is the requirement to measure the location of sufficient reference and object points established on the monitored structure. The number of reference and object points is limited when using classical methods, but not when using a laser scanner. Due to the limitations of classical geodetic survey methods, such as difficulty of application, high costs and low production speed, the present study applied ground laser scanners to deformation monitoring. A two-dimensional (2D) deformation survey was made of a concrete frame placed on a loading wall. Cartesian coordinates, derived from survey and evaluations, were converted into a standard coordinate system using the Molodensky–Badekas 3D similarity transformation. Student’s t test has been used to determine whether it was significant with the difference of coordinates or not. The deformation amounts and directions obtained from the electronic tachymeter and ground laser scanners were found to be very similar.

42 ENGINEERING↗

In situ observations of cracking in constrained sintering

Here in this article, we examine the long-standing problem of cracking during constrained sintering of a powder aggregate. Using binder jet 3D printing, we prepare ceramic green bodies in the form of center-notched panels, then use in situ imaging to observe how cracks nucleate and grow from the notch as the material sinters under restraint. Quantitative image analysis allows us to identify important characteristics of the sinter-cracking process, indicating a framework for analyzing the problem and developing methods for avoiding it, including representation of sinter-cracking as a creep crack growth process, use of fracture mechanics parameters to design specimen geometries that do not exceed critical stress intensities, and the possibility of exploiting the inherently ductile nature of sinter-cracking to mitigate damage.

36 MATERIALS SCIENCE↗

Joint Non-Parametric Correction Estimator for Excess Relative Risk Regression in Survival Analysis with Exposure Measurement Error

Summary Observational epidemiological studies often confront the problem of estimating exposure–disease relationships when the exposure is not measured exactly. We investigate exposure measurement error in excess relative risk regression, which is a widely used model in radiation exposure effect research. In the study cohort, a surrogate variable is available for the true unobserved exposure variable. The surrogate variable satisfies a generalized version of the classical additive measurement error model, but it may or may not have repeated measurements. In addition, an instrumental variable is available for individuals in a subset of the whole cohort. We develop a non-parametric correction estimator by using data from the subcohort and further propose a joint non-parametric correction estimator using all observed data to adjust for exposure measurement error. An optimal linear combination estimator of the joint non-parametric correction and non-parametric correction is further developed. The estimators proposed are non-parametric, which are consistent without imposing a covariate or error distribution, and are robust to heteroscedastic errors. Finite sample performance is examined via a simulation study. We apply the developed methods to data from the Radiation Effects Research Foundation, in which chromosome aberration is used to adjust for the effects of radiation dose measurement error on the estimation of radiation dose responses.

Wang, Ching-Yun↗

First-principles study of magnetism and electric field effects in 2D systems

This review article provides a bird's-eye view of what first-principles based methods can contribute to next-generation device design and simulation. After a brief overview of methods and capabilities in the area, the authors focus on published work by their group since 2015 and current work on CrI3. The authors introduce both single- and dual-gate models in the framework of density functional theory and the constrained random phase approximation in estimating the Hubbard U for 2D systems vs their 3D counterparts. A wide range of systems, including graphene-based heterogeneous systems, transition metal dichalcogenides, and topological insulators, and a rich array of physical phenomena, including the macroscopic origin of polarization, field effects on magnetic order, interface state resonance induced peak in transmission coefficients, spin filtration, etc., are covered. For CrI3, the authors present their new results on bilayer systems such as the interplay between stacking and magnetic order, pressure dependence, and electric field induced magnetic phase transitions. The authors find that a bare bilayer CrI3, graphene|bilayer CrI3|graphene, hexagonal boron nitride (h-BN)|bilayer CrI3|h-BN, and h-BN|bilayer CrI3|graphene all have a different response at high field, while at small field, the difference is small except for graphene|bilayer CrI3|graphene. The authors conclude with discussion of some ongoing work and work planned in the near future, with the inclusion of further method development and applications.

Cheng, Hai-Ping (ORCID:0000000159901725)↗

Plasma enhanced atomic layer deposition and atomic layer etching of gallium oxide using trimethylgallium

Atomic layer etching driven by self-limiting thermal reactions has recently been developed as a highly conformal and isotropic technique for low damage atomic scale material removal by sequential exposures of vapor phase reactants. Gallium oxide (Ga2O3) is currently among the materials of interest due to a large variety of applications including power electronics, solar cells, gas sensors, and photon detectors. In this study, Ga2O3 was deposited by plasma enhanced atomic layer deposition using trimethylgallium [TMG, Ga(CH3)3] and O2 plasma at a substrate temperature of 200 °C. We report a newly developed method for Ga2O3 thermal atomic layer etching, in which surface modification is achieved through HF exposure resulting in a gallium fluoride surface layer, and then removed through volatile product formation via ligand exchange with TMG. Saturation of the precursor exposure at a substrate temperature of 300 °C resulted in an etch rate of 1.0 ± 0.1 Å/cycle for amorphous Ga2O3. Uniformity and conformality of the atomic layer etching process were confirmed via atomic force microscopy with a measured surface roughness of 0.55 ± 0.05 nm that remains unchanged after etching. The use of TMG for etching may expand available precursors for atomic layer etching processes, while allowing for both etching and deposition of Ga2O3 using the same metalorganic precursor.

Hatch, Kevin A. (ORCID:0000000283118623)↗

Infrared reflectance spectra: Effects of particle size, provenance and preparation

We have recently developed methods for making more accurate infrared total and diffuse directional - hemispherical reflectance measurements using an integrating sphere. We have found that reflectance spectra of solids, especially powders, are influenced by a number of factors including the sample preparation method, the particle size and morphology, as well as the sample origin. On a quantitative basis we have investigated some of these parameters and the effects they have on reflectance spectra, particularly in the longwave infrared. In the IR the spectral features may be observed as either maxima or minima: In general, upward-going peaks in the reflectance spectrum result from strong surface scattering, i.e. rays that are reflected from the surface without bulk penetration, whereas downward-going peaks are due to either absorption or volume scattering, i.e. rays that have penetrated or refracted into the sample interior and are not reflected. The light signals reflected from solids usually encompass all such effects, but with strong dependencies on particle size and preparation. This paper measures the reflectance spectra in the 1.3 – 16 micron range for various bulk materials that have a combination of strong and weak absorption bands in order to observe the effects on the spectral features: Bulk materials were ground with a mortar and pestle and sieved to separate the samples into various size fractions between 5 and 500 microns. The median particle size is demonstrated to have large effects on the reflectance spectra. For certain minerals we also observe significant spectral change depending on the geologic origin of the sample. All three such effects (particle size, preparation and provenance) result in substantial change in the reflectance spectra for solid materials; successful identification algorithms will require sufficient flexibility to account for these parameters.

Reflectance, Hemispherical reflectance, integratin↗

Investigation on lateral resolution of surface slope profilers

Here, we investigate and compare the spatial (lateral) resolution, or more generally, the optical/instrumental transfer function (OTF/ITF) of surface slope measuring profilometers of two different types that are commonly used for high accuracy characterization of x-ray optics at the long-spatial-wavelength range. These are an autocollimator based profiler, Optical Surface Measuring System (OSMS), and a long trace profiler, LTP-II, both available at the Advanced Light Source (ALS) X-Ray Optics Lab (XROL). In the OSMS, an ELCOMAT-3000 electronic auto-collimator, vertically mounted to the translation carriage and equipped with an aperture of 2.5 mm diameter, is scanned along the surface under test. The LTP-II OTF has been measured for two different configurations, a classical two-beam pencil-beam-interferometry and a single-Gaussian-beam deflectometry. For the ITF calibration, we apply a recently developed method based on test surfaces with one-dimensional (1D) linear chirped height profiles of constant slope amplitude. Analytical expressions for the OTFs, empirically deduced based on the experimental results, are presented. We also discuss the application of the results of the ITF measurements and modeling to improve the surface slope metrology with state-of-the-art x-ray mirrors.

42 ENGINEERING↗

Second-surface silvered glass solar mirrors of very high reflectance

This paper reports methods developed to maximize the overall reflectance second-surface silvered glass. The reflectance at shorter wavelengths is increased with the aid of a dielectric enhancing layer between the silver and the glass, while at longer wavelengths it is enhanced by use of glass with negligible iron content. The calculated enhancement of reflectance, compared to unenhanced silver on standard low-iron float glass, corresponds to a 4.4% increase in reflectance averaged across the full solar spectrum, appropriate for CSP, and 2.7% for CPV systems using triple junction cells. An experimental reflector incorporating these improvements, of drawn crown glass and a silvered second-surface with dielectric boost, was measured at NREL to have 95.4% solar weighted reflectance. For comparison, non-enhanced, wetsilvered reflectors of the same 4 mm thickness show reflectance ranging from 91.6 - 94.6%, depending on iron content. A potential drawback of using iron-free drawn glass is reduced concentration in high concentration systems because of the inherent surface errors. This effect is largely mitigated for glass shaped by slumping into a concave mold, rather than by bending.

14 SOLAR ENERGY↗

Accuracy of Acuros XB and AAA dose calculation for small fields with reference to RapidArc stereotactic treatments

Purpose: To assess the accuracy against measurements of two photon dose calculation algorithms (Acuros XB and the Anisotropic Analytical algorithm AAA) for small fields usable in stereotactic treatments with particular focus on RapidArc. Methods: Acuros XB and AAA were configured for stereotactic use. Baseline accuracy was assessed on small jaw-collimated open fields for different values for the spot sizes parameter in the beam data: 0.0, 0.5, 1, and 2 mm. Data were calculated with a grid of 1 x 1 mm{sup 2}. Investigated fields were: 3 x 3, 2 x 2, 1 x 1, and 0.8 x 0.8 cm{sup 2} with a 6 MV photon beam generated from a Clinac2100iX (Varian, Palo Alto, CA). Profiles, PDD, and output factors were measured in water with a PTW diamond detector (detector size: 4 mm{sup 2}, thickness 0.4 mm) and compared to calculations. Four RapidArc test plans were optimized, calculated and delivered with jaw settings J3 x 3, J2 x 2, and J1 x 1 cm{sup 2}, the last was optimized twice to generate high (H) and low (L) modulation patterns. Each plan consisted of one partial arc (gantry 110 deg. to 250 deg.), and collimator 45 deg. Dose to isocenter was measured in a PTW Octavius phantom and compared to calculations. 2D measurements were performed by means of portal dosimetry with the GLAaS method developed at authors' institute. Analysis was performed with gamma pass-fail test with 3% dose difference and 2 mm distance to agreement thresholds. Results: Open square fields: penumbrae from open field profiles were in good agreement with diamond measurements for 1 mm spot size setting for Acuros XB, and between 0.5 and 1 mm for AAA. Maximum MU difference between calculations and measurements was 1.7% for Acuros XB (0.2% for fields greater than 1 x 1 cm{sup 2}) with 0.5 or 1 mm spot size. Agreement for AAA was within 0.7% (2.8%) for 0.5 (1 mm) spot size. RapidArc plans: doses were evaluated in a 4 mm diameter structure at isocenter and computed values differed from measurements by 0.0, -0.2, 5.5, and -3.4% for Acuros XB calculations (1 mm spot size), and of -0.1, 0.3, 6.7, and -1.2% for AAA, respectively for J3 x 3, J2 x 2, J1 x 1H, J1 x 1L RapidArc plans. Gamma Agreement Index from 2D dose analysis was higher than 95% for J3 x 3 and J2 x 2 plans, being around 80% for J1 x 1 maps. Sensitivity with respect to the dosimetric leaf gap and transmission factor MLC parameters was evaluated in the four RapidArc plans, showing the need to properly set the dosimetric leaf gap for accurate calculations. Conclusions: Acuros XB and AAA showed acceptable characteristics for stereotactic small fields if adequate tuning of configuration parameters is performed. Dose calculated for RapidArc stereotactic plans showed an acceptable agreement against point and 2D measurements. Both algorithms can therefore be considered safely applicable to stereotactic treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-233: A Facility for Radiobiological Experiments in a Large Magnetic Field

Purpose: There is considerable interest in developing medical linear accelerators with integrated image guidance by MRI. Less work has been done on the fundamental biology of cell survival in the presence of a strong magnetic field. The purpose of this work is to describe an experimental system capable of measuring cell survival response in the types of MRI-linac systems currently under development. Methods: We have integrated a cobalt irradiator with a solenoid magnet. The solenoid magnet has inner diameter of 10 cm. To enable measurement of the biological effects as a function of depth, we are utilizing the sliced gel technique, in which cells are embedded and fixed within a gelatin matrix. Irradiated cells at defined positions (sub mm resolution) can subsequently be recovered and assessed for cell survival or other biological effects. Results: The magnetic field profile in the solenoid has a peak magnetic field 36 cm below the top edge of the magnet bore and can be placed at and SAD of 100 cm. At a solenoid current of 35 A, the peak magnetic field is 0.25 T. The dose rate of the cobalt irradiator is 16 cGy/min at 100 cm SAD. EBT3 film was used to demonstrate the system functionality. It was irradiated at 1 cm depth at 100 cm SSD with a 4×4 field to 1.5 Gy in a 0.25 T magnetic field. The dose profile was similar between this film and the control exposure without magnetic field. Conclusion: Integrating a cobalt irradiator with a high field magnet is demonstrated. The magnetic field at the cobalt defining head was minimal and did not interfere with the functioning of this unit. Cell survival experiments can be reproduced exactly in the presence or absence of a magnetic field since a resistive magnet is used.

60 APPLIED LIFE SCIENCES↗

SU-E-T-154: Establishment and Implement of 3D Image Guided Brachytherapy Planning System

Purpose: Cannot observe the dose intuitionally is a limitation of the existing 2D pre-implantation dose planning. Meanwhile, a navigation module is essential to improve the accuracy and efficiency of the implantation. Hence a 3D Image Guided Brachytherapy Planning System conducting dose planning and intra-operative navigation based on 3D multi-organs reconstruction is developed. Methods: Multi-organs including the tumor are reconstructed in one sweep of all the segmented images using the multiorgans reconstruction method. The reconstructed organs group establishs a three-dimensional visualized operative environment. The 3D dose maps of the three-dimentional conformal localized dose planning are calculated with Monte Carlo method while the corresponding isodose lines and isodose surfaces are displayed in a stereo view. The real-time intra-operative navigation is based on an electromagnetic tracking system (ETS) and the fusion between MRI and ultrasound images. Applying Least Square Method, the coordinate registration between 3D models and patient is realized by the ETS which is calibrated by a laser tracker. The system is validated by working on eight patients with prostate cancer. The navigation has passed the precision measurement in the laboratory. Results: The traditional marching cubes (MC) method reconstructs one organ at one time and assembles them together. Compared to MC, presented multi-organs reconstruction method has superiorities in reserving the integrality and connectivity of reconstructed organs. The 3D conformal localized dose planning, realizing the 'exfoliation display' of different isodose surfaces, helps make sure the dose distribution has encompassed the nidus and avoid the injury of healthy tissues. During the navigation, surgeons could observe the coordinate of instruments real-timely employing the ETS. After the calibration, accuracy error of the needle position is less than 2.5mm according to the experiments. Conclusion: The speed and quality of 3D reconstruction, the efficiency in dose planning and accuracy in navigation all can be improved simultaneously.

60 APPLIED LIFE SCIENCES↗

SU-E-QI-16: Reproducibility of Computed Tomography Quantitative Structural Features Using the FDA Thoracic Phantom Image Database

Purpose: To assess the reproducibility of quantitative structural features using images from the computed tomography thoracic FDA phantom database under different scanning conditions. Methods: Development of quantitative image features to describe lesion shape and size, beyond conventional RECIST measures, is an evolving area of research in need of benchmarking standards. Gavrielides et al. (2010) scanned a FDA-developed thoracic phantom with nodules of various Hounsfield units (HU) values, shapes and sizes close to vascular structures using several scanners and varying scanning conditions/parameters; these images are in the public domain. We tested six structural features, namely, Convexity, Perimeter, Major Axis, Minor Axis, Extent Mean and Eccentricity, to characterize lung nodules. Convexity measures lesion irregularity referenced to a convex surface. Previously, we showed it to have prognostic value in lung adenocarcinoma. The above metrics and RECIST measures were evaluated on three spiculated (8mm/-300HU, 12mm/+30HU and 15mm/+30HU) and two non-spiculated (8mm/+100HU and 10mm/+100HU) nodules (from layout 2) imaged at three different mAs values: 25, 100 and 200 mAs; on a Phillips scanner (16-slice Mx8000-IDT; 3mm slice thickness). The nodules were segmented semi-automatically using a commercial software tool; the same HU range was used for all nodules. Results: Analysis showed convexity having the lowest maximum coefficient of variation (MCV): 1.1% and 0.6% for spiculated and non-spiculated nodules, respectively, much lower compared to RECIST Major and Minor axes whose MCV were 10.1% and 13.4% for spiculated, and 1.9% and 2.3% for non-spiculated nodules, respectively, across the various mAs. MCVs were consistently larger for speculated nodules. In general, the dependence of structural features on mAs (noise) was low. Conclusion: The FDA phantom CT database may be used for benchmarking of structural features for various scanners and scanning conditions; we used only a small fraction of available data. Our feature convexity outperformed other structural features including RECIST measures.

60 APPLIED LIFE SCIENCES↗

Sci—Thur AM: YIS - 11: Estimation of Bladder-Wall Cumulative Dose in Multi-Fraction Image-Based Gynaecological Brachytherapy Using Deformable Point Set Registration

Dosimetric parameters based on dose-volume histograms (DVH) of contoured structures are routinely used to evaluate dose delivered to target structures and organs at risk. However, the DVH provides no information on the spatial distribution of the dose in situations of repeated fractions with changes in organ shape or size. The aim of this research was to develop methods to more accurately determine geometrically localized, cumulative dose to the bladder wall in intracavitary brachytherapy for cervical cancer. The CT scans and treatment plans of 20 cervical cancer patients were used. Each patient was treated with five high-dose-rate (HDR) brachytherapy fractions of 600cGy prescribed dose. The bladder inner and outer surfaces were delineated using MIM Maestro software (MIM Software Inc.) and were imported into MATLAB (MathWorks) as 3-dimensional point clouds constituting the “bladder wall”. A point-set registration toolbox for MATLAB, Coherent Point Drift (CPD), was used to non-rigidly transform the bladder-wall points from four of the fractions to the coordinate system of the remaining (reference) fraction, which was chosen to be the emptiest bladder for each patient. The doses were accumulated on the reference fraction and new cumulative dosimetric parameters were calculated. The LENT-SOMA toxicity scores of these patients were studied against the cumulative dose parameters. Based on this study, there was no significant correlation between the toxicity scores and the determined cumulative dose parameters.

60 APPLIED LIFE SCIENCES↗