Search NASA⌕ Search

SEARCH · Search NASA

Results for “MicroED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Bright tunable femtosecond x-ray emission from laser irradiated micro-droplets

It is demonstrated that bright femtosecond X-rays can be obtained by irradiating a moderate laser onto a helium micro-droplet. The laser ponderomotive force continuously sweeps electrons from the droplets and accelerates them forward. The electrons exposed in the outrunning laser field oscillate transversely and emit photons in the forward direction. The total flux of photons with energies above 1 keV is as high as 10{sup 9}/shot which is about 10-fold enhancement compared with betatron oscillation under similar laser conditions. The maximum achieved peak brightness is up to 10{sup 21} photons/s/mm{sup 2}/mrad{sup 2}/0.1%BW. By adjusting laser and droplet parameters, we can get tunable X-rays with required brightness and energy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Geometry optimization for micro-pressure sensor considering dynamic interference

Presented is the geometry optimization for piezoresistive absolute micro-pressure sensor. A figure of merit called the performance factor (PF) is defined as a quantitative index to describe the comprehensive performances of a sensor including sensitivity, resonant frequency, and acceleration interference. Three geometries are proposed through introducing islands and sensitive beams into typical flat diaphragm. The stress distributions of sensitive elements are analyzed by finite element method. Multivariate fittings based on ANSYS simulation results are performed to establish the equations about surface stress, deflection, and resonant frequency. Optimization by MATLAB is carried out to determine the dimensions of the geometries. Convex corner undercutting is evaluated. Each PF of the three geometries with the determined dimensions is calculated and compared. Silicon bulk micromachining is utilized to fabricate the prototypes of the sensors. The outputs of the sensors under both static and dynamic conditions are tested. Experimental results demonstrate the rationality of the defined performance factor and reveal that the geometry with quad islands presents the highest PF of 210.947 Hz{sup 1/4}. The favorable overall performances enable the sensor more suitable for altimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In vitro cytotoxicity tests of ZnO‐Bi{sub 2}O{sub 3}‐Mn{sub 2}O{sub 3}-based varistor fabricated from ZnO micro and nanoparticle powders on L929 mouse cells

The present study investigated the cytotoxicity of ZnO‐Bi{sub 2}O{sub 3}‐Mn{sub 2}O{sub 3}-varistors. To this effect, ZnO‐Bi{sub 2}O{sub 3}‐Mn{sub 2}O{sub 3} varistors fabricated from ZnO micro-and nanoparticle powders are prepared via conventional ceramic processing method. The effects of ZnO particle size on the properties of ZnO varistors are also investigated. The strong solid-state reaction during sintering may be attributed to the high surface area of the 20 nm ZnO nanoparticles that promote strong surface reaction. The intensity of XRD peaks reflected the high degree of crystallinity of the ZnO nanoparticles. However, the width of the peaks in case of ZnO nanoparticles has increased due to the quantum size effect. The cytotoxicity evaluation of ZnO varistor was conducted on mouse connective tissue fibroblast cells (L929) using Trypan Blue Exclusion Assay analysis. The results show that the four types of varistor samples lead to cellular mitochondrial dysfunction, morphological modifications and apoptosis at the various concentration range and the toxic effects are obviously displayed in high concentration samples. 20nm-VDR is the most toxic materials followed by 40nm-VDR, P8-VDR, and W4-VDR in a descending order.

36 MATERIALS SCIENCE↗

Temperature-dependent efficiency droop of blue InGaN micro-light emitting diodes

Temperature-dependent trends in radiative and Auger recombination coefficients have been determined at different injection carrier concentrations using InGaN micro-light emitting diodes 40 μm in diameter. The differential lifetime was obtained first from the measured modulation bandwidth and was then employed to calculate the carrier concentration in the quantum well active region. When the temperature increases, the carrier concentration increases, but both the radiative and Auger recombination coefficients decrease. In addition, the temperature dependence of radiative and Auger recombination coefficients is weaker at a higher injection carrier concentration, which is strongly related to phase space filling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of TLD-100 micro-cubes for use in small field dosimetry

At present there are no international regulations for the management of millimeter scale fields and there are no suggestions for a reference detector to perform the characterization and dose determination for unconventional radiation beams (small fields) so that the dosimetry of small fields remains an open research field worldwide because these fields are used in radiotherapy treatments. Sensitivity factors and reproducibility of TLD-100 micro-cubes (1×1×1 mm3) were determinate irradiating the dosimeters with a 6 MV beam in a linear accelerator dedicated to radiosurgery at the Instituto Nacional de Neurología y Neurocirugía (INNN). Thermoluminescent response as a function of dose was determined for doses in water between 0.5 and 3 Gy and two field sizes (2×2 cm2 and 10×10 cm2). It was found that the response is linear over the dose range studied and it does not depend on field size.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mass flow rate and pressure distribution of gas through three-dimensional micro-channels

An effective method to predict the mass flow rate and pressure distribution of gas through three dimensional micro-channels with different cross-section shapes has been proposed. For rectangular cross sections often employed in experiment, the present solutions versus measured data of Zohar et al. (2002) show that the side walls significantly affect the mass flow rates as the aspect ratio is smaller than 10, whereas the non-dimensional pressure distributions, mainly determined by the inlet-to-outlet pressure ratio, are insensitive to the aspect ratio.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Internal air flow analysis of a bladeless micro aerial vehicle hemisphere body using computational fluid dynamic

This paper explain the analysis of internal air flow velocity of a bladeless vertical takeoff and landing (VTOL) Micro Aerial Vehicle (MAV) hemisphere body. In mechanical design, before produce a prototype model, several analyses should be done to ensure the product's effectiveness and efficiency. There are two types of analysis method can be done in mechanical design; mathematical modeling and computational fluid dynamic. In this analysis, I used computational fluid dynamic (CFD) by using SolidWorks Flow Simulation software. The idea came through to overcome the problem of ordinary quadrotor UAV which has larger size due to using four rotors and the propellers are exposed to environment. The bladeless MAV body is designed to protect all electronic parts, which means it can be used in rainy condition. It also has been made to increase the thrust produced by the ducted propeller compare to exposed propeller. From the analysis result, the air flow velocity at the ducted area increased to twice the inlet air. This means that the duct contribute to the increasing of air velocity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser-written parabolic micro-antennas for efficient photon collection

Efficient collection of photons from solid-state single-photon emitters, like quantum dots, molecules, or defect centers in diamond, is a very demanding task. Here, we introduce parabolic micro-antennas fabricated by two-photon direct laser-writing to enhance the collection efficiency by directing emitted light into a small solid angle. The antennas can be fabricated on-site at the position of a pre-selected single-photon emitter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stopping potential and ion beamlet control for micro-resistive patterning through sub-Debye length plasma apertures

Focused multiple ion beamlets from a microwave plasma source is investigated for localized micron-scale modification of substrates in a patterned manner. Plasma electrodes (PE) with an array of through apertures having aperture diameters of the order of plasma Debye length are investigated for generating the beamlets. Extraction through sub-Debye length apertures becomes possible when the PE is kept at floating potential. It is found that the current – voltage characteristics of the extracted beamlets exhibits interesting features such as a space-charge-limited region that has a different behaviour than the conventional Child-Langmuir’s law and an extraction-voltage-limited region that does not undergo saturation but exhibits a Schottky-like behaviour similar to that of a vacuum diode. A switching technique to control the motion of individual beamlets is developed and the stopping potential determined. The beamlets are thereafter used to create localized micro-resistive patterns. The experimental results are compared with simulations and reasonably good agreement is obtained.

36 MATERIALS SCIENCE↗

High performance techniques for micro channel plate computations in photo multipliers

Monte Carlo - MC methods, requiring heavy computations of large data volume, can be used to predict the amplitude distribution and variance of outputted electron charge in Micro Channel Plates - MCPs, which are fed with primary emitted electrons in their inputs. The concept of parallel and serial combination of separate stages of such stochastic processes, which can be applied in MCP systems and simulated using MC computations, has recently proposed and shown interesting theorems and results. Separating the electron multiplication procedures, occurring in the channels of MCP systems, into sub-procedures, which are similar in nature and occur either in parallel or in consecutive manners, is equivalent to splitting the relevant stochastic system calculations into smaller ones, which can be performed concurrently and/or sequentially. In this way, calculations similar in nature, can be executed only once, thus, eliminating a great percentage of heavy computations. However, when designing and implementing the calculation inferences of the derived theorems using High Performance Computation - HPC techniques, the overall computation cost can further and significantly be reduced. In this paper, the hardware mappings of the relevant theorem inferences onto parallel computing architectures, resulting in circuits of computing blocks for calculation purposes of MCP system stochastic processes, are investigated. Each of the designed and implemented computing circuits corresponds to a theorem inference or to a combination of inferences. The parallelism of the proposed circuits consists of both the concurrent functioning of all the system blocks and of the simultaneous operation of each block, which is processing pieces of data, for many parts of the whole circuit in which it belongs. All the circuits are designed and tested using Altera Quartus II environment and can be implemented as chips, which can be incorporated in computing devices to assist Monte Carlo computations for the estimation of different MCP electron multiplication system performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrical and terahertz magnetospectroscopy studies of laser-patterned micro- and nanostructures on InAs-based heterostructures

Nanostructures fabricated from narrow-gap semiconductors with strong spin-orbit interaction (SOI), such as InAs, can be used to filter momentum modes of electrons and offer the possibility to create and detect spin-polarized currents entirely by electric fields. Here, we present magnetotransport and THz magnetospectroscopy investigations of Hall-bars with back-gates made from in InGaAs/InAlAs quantum well structures with a strained 4 nm InAs-inserted channel. The two-dimensional electron gas is at 53 nm depth and has a carrier density of about 6 × 10{sup 11 }cm{sup −2} and mobility of about 2 × 10{sup 5} cm{sup 2}/Vs, after illumination. Electrical and THz optical transport measurements at low temperatures and in high magnetic fields reveal an effective mass of 0.038m{sub 0} and an anisotropic g-factor of up to 20, larger than for bulk InAs or InAs-based heterostructures. We demonstrate that quasi-one-dimensional channels can be formed by micro-laser lithography. The population of subbands is controlled by in-plane gates. Contrary to previous reports, symmetric and asymmetric in-plane gate voltages applied to quasi-one dimensional channels did not show indications of SOI-induced anomalies in the conductance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Micro-focused Brillouin light scattering study of the magnetization dynamics driven by Spin Hall effect in a transversely magnetized NiFe nanowire

We employed micro-focused Brillouin light scattering to study the amplification of the thermal spin wave eigenmodes by means of a pure spin current, generated by the spin-Hall effect, in a transversely magnetized Pt(4 nm)/NiFe(4 nm)/SiO{sub 2}(5 nm) layered nanowire with lateral dimensions 500 × 2750 nm{sup 2}. The frequency and the cross section of both the center (fundamental) and the edge spin wave modes have been measured as a function of the intensity of the injected dc electric current. The frequency of both modes exhibits a clear redshift while their cross section is greatly enhanced on increasing the intensity of the injected dc. A threshold-like behavior is observed for a value of the injected dc of 2.8 mA. Interestingly, an additional mode, localized in the central part of the nanowire, appears at higher frequency on increasing the intensity of the injected dc above the threshold value. Micromagnetic simulations were used to quantitatively reproduce the experimental results and to investigate the complex non-linear dynamics induced by the spin-Hall effect, including the modification of the spatial profile of the spin wave modes and the appearance of the extra mode above the threshold.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Self-consistent simulation of radio frequency multipactor on micro-grooved dielectric surface

The multipactor plays a key role in the surface breakdown on the feed dielectric window irradiated by high power microwave. To study the suppression of multipactor, a 2D electrostatic PIC-MCC simulation code was developed. The space charge field, including surface deposited charge and multipactor electron charge field, is obtained by solving 2D Poisson's equation in time. Therefore, the simulation is self-consistent and does not require presetting a fixed space charge field. By using this code, the self-consistent simulation of the RF multipactor on the periodic micro-grooved dielectric surface is realized. The 2D space distributions of the multipactor electrons and space charge field are presented. From the simulation results, it can be found that only half slopes have multipactor discharge when the slope angle exceeds a certain value, and the groove presents a pronounced suppression effect on the multipactor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Micro- and nanostructured electro-active polymer actuators as smart muscles for incontinence treatment

Treatments of severe incontinence are currently based on purely mechanical systems that generally result in revision after three to five years. Our goal is to develop a prototype acting in a natural-analogue manner as artificial muscle, which is based on electro-active polymers. Dielectric actuators have outstanding performances including millisecond response times, mechanical strains of more than 10 % and power to mass densities similar to natural muscles. They basically consist of polymer films sandwiched between two compliant electrodes. The incompressible but elastic polymer film transduces the electrical energy into mechanical work according to the Maxwell pressure. Available polymer films are micrometers thick and voltages as large as kV are necessary to obtain 10 % strain. For medical implants, polymer films should be nanometer thin to realize actuation below 48 V. The metallic electrodes have to be stretchable to follow the strain of 10 % and remain conductive. Recent results on the stress/strain behavior of anisotropic EAP-cantilevers have shown dependencies on metal electrode preparation. We have investigated tunable anisotropic micro- and nanostructures for metallic electrodes. They show a preferred actuation direction with improved stress-strain behavior. The bending of the cantilever has been characterized by the laser beam deflection method. The impact of the electrode on the effective Young's Modulus is measured using an Ultra Nanoindentation Tester with an integrated reference system for soft polymer surfaces. Once ten thousand layers of nanometer-thin EAP actuators are available, devices beyond the envisioned application will flood the market.

36 MATERIALS SCIENCE↗

Neutral gas temperature maps of the pin-to-plate argon micro discharge into the ambient air

This study is designed to explore the two dimensional temperature maps of the atmospheric argon discharge consisting of pin-to-plane electrodes supplied by a high voltage DC source. After checking the stability of the micro discharge, the two dimensional image plane focused by a quartz lens was scanned by the fiber probe driven by a 3D Mobile Platform. The rotational and vibrational temperatures are calculated using nitrogen emissions collected by the high resolution spectrometer and high sensitive intensified charge coupled device. The rotational temperature varies from 1558.15 K to 2621.14 K and vibrational temperature varies from 3010.38 K to 3774.69 K, indicating a great temperature gradient due to small discharge size. The temperature maps show a lateral expansion and a sharp truncation in the radial direction. A double layers discharge is identified, where an arc discharge coats the glow discharge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active investigation of material damage under load using micro-CT

Due the growth of composite materials across multiple industries such as Aviation, Wind there is an increasing need to not just standardize and improve manufacturing processes but also to design these materials for the specific applications. One of the things that this translates to is understanding how failure initiates and grows in these materials and at what loads, especially around internal flaws such as voids or features such as ply drops. Traditional methods of investigating internal damage such as CT lack the resolution to resolve ply level damage in composites. Interrupted testing with layer removal can be used to investigate internal damage using microscopy; however this is a destructive method. Advanced techniques such as such as DIC are useful for in-situ damage detection, however are limited to surface information and would not enable interrogating the volume. Computed tomography has become a state of the art technique for metrology and complete volumetric investigation especially for metallic components. However, its application to the composite world is still nascent. This paper demonstrates micro-CT’s capability as a gauge to quantitatively estimate the extent of damage and understand the propagation of damage in PMC composites while the component is under stress.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of micro-electromechanical system (MEMS) cochlear biomodel

Human cochlear is undeniably one of the most amazing organs in human body. The functional mechanism is very unique in terms of its ability to convert the sound waves in the form of mechanical vibrations into the electrical nerve impulses. It is known that the normal human auditory system can perceive the audible frequency range between 20 Hz to 20 kHz. Scientists have conducted several researches trying to build the artificial basilar membrane in the human cochlea (cochlear biomodel). Micro-electromechanical system (MEMS) is one of the potential inventions that have the ability to mimic the active behavior of the basilar membrane. In this paper, an array of MEMS bridge beams that are mechanically sensitive to the perceived audible frequency has been proposed. An array of bridge bridge beams with 0.5 µm thickness and length varying from 200 µm to 2000 µm have been designed operate within the audible frequency range. In the bridge beams design, aluminium (Al), copper (Cu), tantalum (Ta) and platinum (Pt) have considered as the material for the bridge beam structure. From the finite element (FE) and lumped element (LE) models of the MEMS bridge beams, platinum has been found to be the best material for the cochlear biomodel design, closely mimicking the basilar membrane.

42 ENGINEERING↗

Beam hardening and smoothing correction effects on performance of micro-ct SkyScan 1173 for imaging low contrast density materials

We have designed and fabricated phantom mimicking breast cancer composition known as a region that has low contrast density. The used compositions are a microcalcifications, fatty tissues and tumor mass by using Al{sub 2}O{sub 3}, C{sub 27}H{sub 46}O, and hard nylon materials. Besides, phantom also has a part to calculate low cost criteria /CNR (Contrast to Noise Ratio). Uniformity will be measured at water distillation medium located in a part of phantom scale contrast. Phantom will be imaged by using micro ct-sky scan 1173 high energy type, and then also can be quantified CT number to examine SkyScan 1173 performance in imaging low contrast density materials. Evaluation of CT number is done at technique configuration parameter using voltage of 30 kV, exposure 0.160 mAs, and camera resolution 560x560 pixel, the effect of image quality to reconstruction process is evaluated by varying image processing parameters in the form of beam hardening corrections with amount of 25%, 66% and100% with each smoothing level S10,S2 and S7. To obtain the better high quality image, the adjustment of beam hardening correction should be 66% and smoothing level reach maximal value at level 10.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗