Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Evaluation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Design and package of a {sup 14}CO{sub 2} field analyzer The Global Monitor Platform (GMP)

Carbon Capture and Sequestration (CCS) is widely accepted as a means to reduce and eliminate the fossil fuel CO{sub 2} (ff- CO{sub 2}) emissions from coal fired power plants. Success of CCS depends on near zero leakage rates over decadal time scales. Currently no commercial methods to determine leakage of ff-CO{sub 2} are available. The Global Monitor Platform (GMP) field analyzer provides high precision analysis of CO{sub 2} isotopes [12C (99%), 13C (<1%), 14C (1.2x10-10 %)] that can differentiate between fossil and biogenic CO{sub 2} emissions. Fossil fuels contain no {sup 14}C; their combustion should lower atmospheric amounts on local to global scales. There is a clear mandate for monitoring, verification and accounting (MVA) of CCS systems nationally and globally to verify CCS integrity, treaty verification (Kyoto Protocol) and to characterize the nuclear fuel cycle. Planetary Emissions Management (PEM), working with the National Secure Manufacturing Center (NSMC), has the goal of designing, ruggedizing and packaging the GMP for field deployment. The system will conduct atmosphere monitoring then adapt the system to monitor water and soil evaluations. Measuring {sup 14}CO{sub 2} in real time will provide quantitative concentration data for ff-CO{sub 2} in the atmosphere and CCS leakage detection. Initial results will be discussed along with design changes for improved detection sensitivity and manufacturability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Covariance Structure of Pu Isotopic Compositions Obtained Using FRAM 5.2

In the nondestructive assay of special nuclear materials, isotopic determination based on the analysis of high-purity Ge high-resolution gamma-ray spectra plays a pivotal role. The isotopic results, which are based on a relative measurement of peak intensities, are used to interpret data acquired using quantitative (mass) nondestructive assay methods. In the case of plutonium measurements, this includes both passive and active neutron techniques, and also calorimetry (heat). Historically, precision estimates on the Pu- isotopic composition have been generated, on a case-by-case basis, by least squares fitting algorithms embedded in the analysis codes, but all other sources of uncertainty have generally been estimated using a top-down approach by item category. A largely neglected consideration is the covariance between the reported abundances and derived quantities – notably Pu-239-effective mass, Pu-240-effective mass and specific thermal power. In this work we study the covariance structure by statistically evaluating repeat spectrum measurements of two known low burn-up heavily filtered Pu items reduced using the spectrum analysis code FRAM 5.2 and alternate standard parameter sets. For routine measurements, however, only a single spectrum from an item will typically be acquired. We therefore discuss how to generate the sought after covariance information from an individual spectrum by spectrum re-sampling, an approach which could be added to provide item specific reports, and compare the two approaches to test its reliability.

Croft, Stephen↗

The Potential NCS issue process - A method to screen emerging issues

The Potential NCS Issue (PNI) Process is a newly developed methodology that allows for the screening of new information potentially adverse to nuclear criticality safety. The PNI Process allows for transparency of possible emerging issues with both contractor management and on-site regulators. Sources of PNI include the -1) discovery of potential errors, inaccuracy, or omission in an effective criticality safety evaluation, -2) field conditions not accounted for in an effective evaluation, and -3) a potential inadequacy in a supporting calculation. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Destructive Analysis of TRISO Particles: Crush/Burn/Leach Followed by Davies-Gray Titration and IDMS

The accurate accounting of nuclear materials is a cornerstone of international nuclear safeguards. One emerging challenge in this domain is the fabrication of TRIstructural ISOtropic (TRISO) particle fuels. Although these innovative fuel forms are critical for advanced reactor applications, their robust refractory ceramics and coating compositions present significant obstacles to destructive analysis (DA) methods. Ensuring full and quantitative recovery from these particles is essential for accurate mass accountancy. The current study was initiated to address these challenges, first by validating a previously established destructive method developed by Oak Ridge National Laboratory (ORNL) for the quantitative recovery of uranium from TRISO particles and then following that process with uranium content determination through isotope dilution mass spectrometry (IDMS) and Davies-Gray titration. This study expands on the scope of a digestive method that was developed under the Advanced Gas Reactor Fuel Development and Qualification program and is currently implemented in both the Coated Particle Fuel Development Laboratory and Irradiated Fuels Examination Laboratory at ORNL. The success of the previous Advanced Gas Reactor work relied on developing a DA method to evaluate the fabrication process and reactor experiments. The methodology described in this report was designed to rigorously investigate the efficacy of the crush/burn/leach sample preparation of TRISO particles; it aims to quantify uranium recovery while also assessing the effects of TRISO constituents (e.g., silicon and zirconium) on analytical precision and accuracy. By comparing the results from the titration method and IDMS, we sought to determine whether existing analytical procedures accepted by the International Atomic Energy Agency (IAEA) could be effectively translated to TRISO fuel forms. The team employed an approach that involved processing replicate TRISO samples, optimizing the milling (i.e., crushing) step and performing serial leaches. The elemental composition of the analytical samples was examined to prepare for interference studies in the second year of this project. The integration of gamma spectrometry to verify residual uranium activity further strengthened the validation. Statistical methods were applied to the collected data to evaluate the uncertainties arising from sampling, sample preparation and uranium quantification. These uncertainties were then compared to the IAEA’s international target values (ITVs). Additional data collected in upcoming project work will strengthen the uncertainty estimates. Ultimately, it is hoped that this project will contribute materially to the body of work related to characterization of TRISO based fuels for the purpose of material accountancy and its applications to international safeguards.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Clinical evaluation of the iterative metal artifact reduction algorithm for CT simulation in radiotherapy

Purpose: To clinically evaluate an iterative metal artifact reduction (IMAR) algorithm prototype in the radiation oncology clinic setting by testing for accuracy in CT number retrieval, relative dosimetric changes in regions affected by artifacts, and improvements in anatomical and shape conspicuity of corrected images. Methods: A phantom with known material inserts was scanned in the presence/absence of metal with different configurations of placement and sizes. The relative change in CT numbers from the reference data (CT with no metal) was analyzed. The CT studies were also used for dosimetric tests where dose distributions from both photon and proton beams were calculated. Dose differences and gamma analysis were calculated to quantify the relative changes between doses calculated on the different CT studies. Data from eight patients (all different treatment sites) were also used to quantify the differences between dose distributions before and after correction with IMAR, with no reference standard. A ranking experiment was also conducted to analyze the relative confidence of physicians delineating anatomy in the near vicinity of the metal implants. Results: IMAR corrected images proved to accurately retrieve CT numbers in the phantom study, independent of metal insert configuration, size of the metal, and acquisition energy. For plastic water, the mean difference between corrected images and reference images was −1.3 HU across all scenarios (N = 37) with a 90% confidence interval of [−2.4, −0.2] HU. While deviations were relatively higher in images with more metal content, IMAR was able to effectively correct the CT numbers independent of the quantity of metal. Residual errors in the CT numbers as well as some induced by the correction algorithm were found in the IMAR corrected images. However, the dose distributions calculated on IMAR corrected images were closer to the reference data in phantom studies. Relative spatial difference in the dose distributions in the regions affected by the metal artifacts was also observed in patient data. However, in absence of a reference ground truth (CT set without metal inserts), these differences should not be interpreted as improvement/deterioration of the accuracy of calculated dose. With limited data presented, it was observed that proton dosimetry was affected more than photons as expected. Physicians were significantly more confident contouring anatomy in the regions affected by artifacts. While site specific preferences were detected, all indicated that they would consistently use IMAR corrected images. Conclusions: IMAR correction algorithm could be readily implemented in an existing clinical workflow upon commercial release. While residual errors still exist in IMAR corrected images, these images present with better overall conspicuity of the patient/phantom geometry and offer more accurate CT numbers for improved local dosimetry. The variety of different scenarios included herein attest to the utility of the evaluated IMAR for a wide range of radiotherapy clinical scenarios.

60 APPLIED LIFE SCIENCES↗

Pulse shape discrimination of Cs 2 LiYCl 6 :Ce 3+ detectors at high count rate based on triangular and trapezoidal filters

Cs 2 LiYCl 6 :Ce 3+ (CLYC) detectors have demonstrated the capability to simultaneously detect γ-rays and thermal and fast neutrons with medium energy resolution, reasonable detection efficiency, and substantially high pulse shape discrimination performance. In this work, a disadvantage of CLYC detectors is the long scintillation decay times, which causes pulse pile-up at moderate input count rate. Pulse processing algorithms were developed based on triangular and trapezoidal filters to discriminate between neutrons and γ-rays at high count rate. The algorithms were first tested using low-rate data. They exhibit a pulse-shape discrimination performance comparable to that of the charge comparison method, at low rate. Then, they were evaluated at high count rate. Neutrons and γ-rays were adequately identified with high throughput at rates of up to 375 kcps. The algorithm developed using the triangular filter exhibits discrimination capability marginally higher than that of the trapezoidal filter based algorithm irrespective of low or high rate. The algorithms exhibit low computational complexity and are executable on an FPGA in real-time. Finally, they are also suitable for application to other radiation detectors whose pulses are piled-up at high rate owing to long scintillation decay times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying Temperature Dependence of Pu(IV) Absorbance Spectra for Advanced Online Monitoring of Nuclear Processes

This article presents a systematic study of Pu(IV) absorbance spectral features as a function of temperature to develop an understanding of this parameter’s effect on chemometric models that can be used as online monitoring tools to support nuclear processing. The descriptive and predictive models that provide real-time feedback of these processes are usually constructed with data collected in conditions typical of a laboratory environment, which can differ drastically from a processing environment. To assess the impact of temperature on Pu(IV) absorbance spectra, 11 samples of Pu(IV) were synthesized with varying HNO 3 concentrations ranging from 0.6 to 9.5 M and heated between 15 and 45 °C. Ultraviolet (UV)–visible (vis)–near-infrared (NIR) absorption spectra collected at different HNO 3 concentrations and temperatures revealed that features associated with Pu(IV) are sensitive to temperature at all HNO 3 concentrations and that changes in features depend on HNO 3 concentration. The contributions of temperature and HNO 3 concentration to variation in Pu(IV) spectral features were evaluated using the principal component analysis of spectra that were baseline-corrected with an asymmetric least-squares method. Furthermore, predictive modeling for HNO 3 concentration with partial least-squares regression of UV–vis–NIR spectra highlighted the importance of accounting for temperature in the calibration set to optimize model performance. This methodology constitutes a new, systematic approach to account for the effect of temperature on the absorption spectra of metal ions and is useful for process monitoring applications in many industries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Geometric GNNs for charged particle tracking at GlueX

Nuclear physics experiments are aimed at uncovering the fundamental building blocks of matter. The experiments involve high-energy collisions that produce complex events with many particle trajectories. Tracking charged particles resulting from collisions in the presence of a strong magnetic field is critical to enable the reconstruction of particle trajectories and precise determination of interactions. It is traditionally achieved through combinatorial approaches that scale worse than linearly as the number of hits grows. Since particle hit data naturally form a point cloud and can be structured as graphs, graph neural networks (GNNs) emerge as an intuitive and effective choice for this task. In this study, we evaluate the GNN model for track finding on the data from the GlueX experiment at Jefferson Lab. We use simulation data to train the model and test on both simulation and real GlueX measurements. We demonstrate that GNN-based track finding outperforms the currently used traditional method at GlueX in terms of segment-based efficiency at a fixed purity while providing faster inferences. We show that the GNN model can achieve significant speedup by processing multiple events in batches, which exploits the parallel computation capability of graphical processing units (GPUs). Finally, we compare the GNN implementation on GPU and field-programmable gate array and describe the trade-off.

batched GNN pipeline↗

SU-E-T-597: Parameterization of the Photon Beam Dosimetry for a Commercial Linear Accelerator

Purpose: In radiation therapy, accurate data acquisition of photon beam dosimetric quantities is important for (1) beam modeling data input into a treatment planning system (TPS), (2) comparing measured and TPS modelled data, (3) a linear accelerator’s (linac) beam characteristics quality assurance process, and (4) establishing a standard data set for data comparison, etcetera. Parameterization of the photon beam dosimetry creates a portable data set that is easy to implement for different applications such as those previously mentioned. The aim of this study is to develop methods to parameterize photon percentage depth doses(PDD), profiles, and total scatter output factors(Scp). Methods: Scp, PDDs and profiles for different field sizes (from 2×2 to 40×40cm{sup 2}), depths and energies were measured in a linac using a three-dimensional water tank. All data were smoothed and profile data were also centered, symmetrized and geometrically scaled. The Scp and PDD data were analyzed using exponential functions. For modelling of open and wedge field profiles, each side was divided into three regions described by exponential, sigmoid and Gaussian equations. The model’s equations were chosen based on the physical principles described by these dosimetric quantities. The equations’ parameters were determined using a least square optimization method with the minimal amount of measured data necessary. The model’s accuracy was then evaluated via the calculation of absolute differences and distance–to–agreement analysis in low gradient and high gradient regions, respectively. Results: All differences in the PDDs’ buildup and the profiles’ penumbra regions were less than 2 mm and 0.5 mm, respectively. Differences in the low gradient regions were 0.20 ± 0.20% and 0.50 ± 0.35% for PDDs and profiles, respectively. For Scp data, all differences were less than 0.5%. Conclusion: This novel analytical model with minimum measurement requirements proved to accurately calculate PDDs, profiles, and Scp for different field sizes, depths and energies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantitative comparison between PGNAA measurements and MCNP calculations in view of the characterization of radioactive wastes in Germany and France

The Forschungszentrum Juelich GmbH (FZJ), together with the Aachen University Rheinisch-Westfaelische Technische Hochschule (RWTH) and the French Alternative Energies and Atomic Energy Commission (CEA Cadarache) are involved in a cooperation aiming at characterizing toxic and reactive elements in radioactive waste packages by means of Prompt Gamma Neutron Activation Analysis (PGNAA). The French and German waste management agencies have indeed defined acceptability limits concerning these elements in view of their projected geological repositories. A first measurement campaign was performed in the new Prompt Gamma Neutron Activation Analysis (PGNAA) facility called MEDINA, at FZJ, to assess the capture gamma-ray signatures of some elements of interest in large samples up to waste drums with a volume of 200 liter. MEDINA is the acronym for Multi Element Detection based on Instrumental Neutron Activation. This paper presents MCNP calculations of the MEDINA facility and quantitative comparison between measurement and simulation. Passive gamma-ray spectra acquired with a high purity germanium detector and calibration sources are used to qualify the numerical model of the crystal. Active PGNAA spectra of a sodium chloride sample measured with MEDINA then allow for qualifying the global numerical model of the measurement cell. Chlorine indeed constitutes a usual reference with reliable capture gamma-ray production data. The goal is to characterize the entire simulation protocol (geometrical model, nuclear data, and postprocessing tools) which will be used for current measurement interpretation, extrapolation of the performances to other types of waste packages or other applications, as well as for the study of future PGNAA facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of Principal Component Analysis for the Monitoring of the Aging Process of Nuclear Electrical Cable Insulation

To ensure the safe operation of nuclear power plants (NPPs), it is critical to understand how NPP electrical cable insulation will degrade under different service environments. In this study, various nondestructive examination methods were selected to evaluate degradation of electrical cable insulation after aging. Elongation at break, indenter modulus, relaxation constant, mass change, total color difference, and carbonyl index were collected stepwise on cross-linked polyethylene (XLPE) cable insulations after predetermined exposure intervals. Three different insulation aging scenarios were investigated: 1) simultaneous irradiation and heating at 150°C, 2) heating at 150°C followed by corresponding times of irradiation at ambient temperature, and 3) irradiation at ambient temperature followed by heating at 150°C for the same duration. A constant dose rate of 300 Gy/hr was selected with a total gamma irradiation absorbed dose up to 320 kGy. To gain insight into the long-term performance of NPP electrical cable insulation, principal component analysis (PCA), a data-driven approach, was utilized to identify key indicators of cable insulation degradation. By reducing the dimensionality of the data while retaining degradation information, PCA was used to highlight the changes in the measured properties under gamma irradiation according to total absorbed dose and the different aging scenarios.

Li, Donghui↗

An Efficient Pipeline for Abdomen Segmentation in CT Images

Computed tomography (CT) scans usually include some disadvantages due to the nature of the imaging procedure, and these handicaps prevent accurate abdomen segmentation. Discontinuous abdomen edges, bed section of CT, patient information, closeness between the edges of the abdomen and CT, poor contrast, and a narrow histogram can be regarded as the most important handicaps that occur in abdominal CT scans. Currently, one or more handicaps can arise and prevent technicians obtaining abdomen images through simple segmentation techniques. In other words, CT scans can include the bed section of CT, a patient’s diagnostic information, low-quality abdomen edges, low-level contrast, and narrow histogram, all in one scan. These phenomena constitute a challenge, and an efficient pipeline that is unaffected by handicaps is required. In addition, analysis such as segmentation, feature selection, and classification has meaning for a real-time diagnosis system in cases where the abdomen section is directly used with a specific size. A statistical pipeline is designed in this study that is unaffected by the handicaps mentioned above. Intensity-based approaches, morphological processes, and histogram-based procedures are utilized to design an efficient structure. Performance evaluation is realized in experiments on 58 CT images (16 training, 16 test, and 26 validation) that include the abdomen and one or more disadvantage(s). The first part of the data (16 training images) is used to detect the pipeline’s optimum parameters, while the second and third parts are utilized to evaluate and to confirm the segmentation performance. The segmentation results are presented as the means of six performance metrics. Thus, the proposed method achieves remarkable average rates for training/test/validation of 98.95/99.36/99.57% (jaccard), 99.47/99.67/99.79% (dice), 100/99.91/99.91% (sensitivity), 98.47/99.23/99.85% (specificity), 99.38/99.63/99.87% (classification accuracy), and 98.98/99.45/99.66% (precision). In summary, a statistical pipeline performing the task of abdomen segmentation is achieved that is not affected by the disadvantages, and the most detailed abdomen segmentation study is performed for the use before organ and tumor segmentation, feature extraction, and classification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of polarization-controlled multi-pass Thomson scattering system in the GAMMA 10 tandem mirror

In the GAMMA 10 tandem mirror, the typical electron density is comparable to that of the peripheral plasma of torus-type fusion devices. Therefore, an effective method to increase Thomson scattering (TS) signals is required in order to improve signal quality. In GAMMA 10, the yttrium-aluminum-garnet (YAG)-TS system comprises a laser, incident optics, light collection optics, signal detection electronics, and a data recording system. We have been developing a multi-pass TS method for a polarization-based system based on the GAMMA 10 YAG TS. To evaluate the effectiveness of the polarization-based configuration, the multi-pass system was installed in the GAMMA 10 YAG-TS system, which is capable of double-pass scattering. We carried out a Rayleigh scattering experiment and applied this double-pass scattering system to the GAMMA 10 plasma. The integrated scattering signal was made about twice as large by the double-pass system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photonuclear cross sections for 197 Au: An update on the gold standard

Cross sections for the 197 Au(γ, n) reaction are broadly used in nuclear physics as a standard for normalizing photonuclear reaction cross-section data at photon beam energies above approximately 8 MeV. In this paper, we report cross-section measurements for the 197 Au(γ, n) 196 Au g+m1 reaction at beam energies from 13 to 31 MeV. Our measurements provide the first cross-section data for this reaction at beam energies above 20 MeV, enabling the use of this reaction as a cross-section standard up to 30 MeV. Also, this work provides first cross-section measurements for the 197 Au(γ, n) 196 Au m2 reaction. In addition, we measured cross-section data for the 197 Au(γ, 3n) 194 Au reaction, which can be used as a cross-section standard above about 25 MeV. These measurements were performed using a new target activation method that is based on the angle-energy correlation of the laser Compton- scattered photon beams at the High Intensity Gamma-ray Source (HIγS). The technique enables measuring photonuclear reaction cross-sections at several discrete beam energies concurrently via a single irradiation on a stack of different targets. Measurements were carried out by irradiating a stack of concentric-ring targets consisting of Au, TiO 2 , Zn, Os, and Au (in order of the γ-ray beam direction). Our data for the 197 Au(γ,n) 196 Au g+m1 reaction in the energy range of 13 to 20 MeV are in good agreement with existing ones measured using monoenergetic γ-ray beams, but differ from data acquired using a bremsstrahlung γ-ray beam. Also, above 18 MeV, our data for the 197 Au(γ,n) 196 Au g+m1 and 197 Au(γ,n) 196 Au m2 reactions differ significantly from the most recent TENDL and JENDL evaluations, suggesting a need to update these data libraries. Furthermore, the TENDL evaluation and existing data are consistent with our data for the 197 Au(γ,3n) reaction, but differ significantly from the JENDL evaluation above 26 MeV.

190 ≤ A ≤ 219↗

Comparison of Collisional and Electron-Based Dissociation Modes for Middle-Down Analysis of Multiply Glycosylated Peptides

Analysis of singly glycosylated peptides has evolved to a point where large-scale LC-MS analyses can be performed at almost the same scale as proteomics experiments. While collisionally activated dissociation (CAD) remains the mainstay of bottom-up analyses, it performs poorly for the middle-down analysis of multiply glycosylated peptides. With improvements in instrumentation, electron-activated dissociation (ExD) modes are becoming increasingly prevalent for proteomics experiments and for the analysis of fragile modifications such as glycosylation. While these methods have been applied for glycopeptide analysis in isolated studies, an organized effort to compare their efficiencies, particularly for analysis of multiply glycosylated peptides (termed here middle-down glycoproteomics), has not been made. We therefore compared the performance of different ExD modes for middle-down glycopeptide analyses. We identified key features among the different dissociation modes and show that increased electron energy and supplemental activation provide the most useful data for middle-down glycopeptide analysis. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computed Tomography-Guided Interstitial HDR Brachytherapy (CT-HDRBT) of the Liver in Patients with Irresectable Intrahepatic Cholangiocarcinoma

Purpose: This study was designed to investigate the clinical outcome of patients with irresectable, intrahepatic cholangiocarcinoma (IHC) treated with computed tomography (CT)-guided HDR-brachytherapy (CT-HDRBT) for local tumor ablation.MethodFifteen consecutive patients with histologically proven cholangiocarcinoma were selected for this retrospective study. Patients were treated by high-dose-rate internal brachytherapy (HDRBT) using an Iridium-192 source in afterloading technique through CT-guided percutaneous placed catheters. A total of 27 brachytherapy treatments were performed in these patients between 2006 and 2009. Median tumor enclosing target dose was 20 Gy, and mean target volume of the radiated tumors was 131 ({+-} 90) ml (range, 10-257 ml). Follow-up consisted of clinical visits and magnetic resonance imaging of the liver every third month. Statistical evaluation included survival analysis using the Kaplan-Meier method. Results: After a median follow-up of 18 (range, 1-27) months after local ablation, 6 of the 15 patients are still alive; 4 of them did not get further chemotherapy and are regarded as disease-free. The reached median local tumor control was 10 months; median local tumor control, including repetitive local ablation, was 11 months. Median survival after local ablation was 14 months and after primary diagnosis 21 months. Conclusion: In view of current clinical data on the clinical outcome of cholangiocarcinoma, locally ablative treatment with CT-HDRBT represents a promising and safe technique for patients who are not eligible for tumor resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

AN ESTIMATE OF SPENT NUCLEAR FUEL MECHANICAL LOADS IN THE GENERAL 30 CM PACKAGE DROP SCENARIO

The US Department of Energy Spent Fuel and Waste Science and Technology (SFWST) program is performing research to determine the mechanical loading conditions applied to spent nuclear fuel (SNF) during normal conditions of transport to inform mechanical tests of SNF and close an important knowledge gap related to the practical disposition of SNF in the US. Researchers at Pacific Northwest National Laboratory (PNNL) have completed an extensive finite element study to characterize and estimate the potential mechanical loads on SNF during a hypothetical 30 cm drop of an SNF transportation package. This modeling study is validated with test data collected by the SFWST program during a physical test campaign that included one-third scale package drop tests and full-scale single fuel assembly drop tests. The test campaign was led by Sandia National Laboratories (SNL) and included international collaboration with Equipos Nucleares S.A, S.M.E (ENSA) and Bundesanstalt für Materialforschung und -prüfung (BAM). The key contribution of the modeling study is to go beyond the limitations of the limited number of physical tests to estimate the impact response to variations in impact angle, initial gap conditions, fuel assembly design, burnup and other parameters that affect the mechanical loads. The methodology of this study included a classic parametric study to calculate the impact response of highly detailed fuel assemblies over many combinations of parameters. Models of a 17x17 pressurized water reactor fuel assembly and a generic 10x10 boiling water reactor fuel assembly were both used in this study to cover the major fuel assembly types in the US inventory. Over 2,000 impact responses were calculated. The results of the parametric study were evaluated using traditional methods and basic statistics. The results were also used to construct a damage model using multiple nonlinear regression techniques to predict the mechanical loads over the full range of all input parameters. The damage model was found to work very well for all impact angle cases where the cask came to rest on its side. It was concluded that end drop cases where the cask remained vertical (instead of tipping over onto its side) were not sufficiently characterized by the current set of parametric study cases to include in the damage model, but it was not a priority to fully investigate that range because the highest mechanical loads were observed in the broader range of side impact cases. This modeling work provides sufficient insight into the mechanical loads on SNF during a hypothetical 30 cm package drop that, when considered along with the physical test data collected by the SNL-led team, the SFSWT program can consider the knowledge gap closed.

Klymyshyn, Nicholas A.↗

Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons

Purpose: The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides ({sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Methods: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source {beta}{sup -}, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the {sup 192}Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Results: Electronic equilibrium within 1% is reached for {sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for {sup 60}Co and {sup 192}Ir, respectively. Electron emissions become important (i.e., >0.5%) within 3.3 mm of {sup 60}Co and 1.7 mm of {sup 192}Ir sources, yet are negligible over all distances for {sup 137}Cs and {sup 169}Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Conclusions: Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

61 RADIATION PROTECTION AND DOSIMETRY↗