Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational Amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

An innovative approach for performance enhancement of 320 Gbps free space optical communication system over turbulent channel

Free space optical (FSO) communication systems have recently gained huge attention as possible last mile solution in delivering high speed data services for terrestrial applications. However the FSO link performance, particularly the link range is significantly limited by the severity of atmospheric adversities affecting the channel. In this paper we advocate the use of multi-hop relay techniques to transmit wavelength division multiplexed (WDM) signal over the FSO channel. Since weather induced impairments in FSO links are distance dependent phenomena, hence relay transmission allows substantial performance enhancement by alleviating channel losses while, WDM provides cost effective solution in improving the transmission capacity. With aggregate link losses as high as 40 dB/km, the proposed 32 channel—10 Gbps (320 Gbps) FSO link has been evaluated by comparing bit error rate (BER) performances and eye patterns over different turbulent regimes. Gain optimized EDFA amplification and conventional electrical amplification have been employed to realize amplify-and-forward (A–F) multi-hop transmission in the proposed link with the former delivering more inspiring BER performance of over the latter. Our simulation results indicate that for receiver SNR of 35 dB, BER improvement up to five orders of magnitude can achieved using triple relay FSO link in contrast to direct link operating under similar conditions. Additionally, it is also observed during the analysis that for target BER of 10{sup −5}, incorporation of triple relay enhances the link range by approximately 1200 m over direct link. However on the flip side, our investigations also revealed that as the number of relay nodes is increased, the SNR gain for specified BER does increase but the magnitude of gain declines. The proposed link was designed and investigated using OptiSystem™ 14.2.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental investigation of nonlinear operation mode of a DP-QPSK 100G link with co-propagating-pump Raman amplification

The nonlinear interference noise in a coherent single-span fibre-optic communication link (FOCL) with co-propagating Raman amplification is investigated at different levels of input Raman pump and channel powers and dispersion. A simple phenomenological expression for calculating the nonlinear noise power at the output of a single-channel FOCL is presented. The merit of using a distributed Raman amplifier with co-propagating pump up to 1 W in a single-span single-channel FOCL is experimentally investigated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reduction in Inflammatory Gene Expression in Skeletal Muscle from Roux-en-Y Gastric Bypass Patients Randomized to Omentectomy

To examine the effects of Roux-en-Y gastric bypass (RYGB) surgery with and without laparoscopic removal of omental fat (omentectomy) on the temporal gene expression profiles of skeletal muscle. Previously reported were the whole-body metabolic effects of a randomized, single-blinded study in patients receiving RYGB surgery stratified to receive or not receive omentectomy. In this follow up study we report on changes in skeletal muscle gene expression in a subset of 21 patients, for whom biopsies were collected preoperatively and at either 6 months or 12 months postoperatively. RNA isolated from skeletal muscle biopsies of 21 subjects (8 without omentectomy and 13 with omentectomy) taken before RYGB or at 6 and 12 months postoperatively were subjected to gene expression profiling via Exon 1.0 S/T Array and Taqman Low Density Array. Robust Multichip Analysis and gene enrichment data analysis revealed 84 genes with at least a 4-fold expression difference after surgery. At 6 and 12 months the RYGB with omentectomy group displayed a greater reduction in the expression of genes associated with skeletal muscle inflammation (ANKRD1, CDR1, CH25H, CXCL2, CX3CR1, IL8, LBP, NFIL3, SELE, SOCS3, TNFAIP3, and ZFP36) relative to the RYGB nonomentectomy group. Expressions of IL6 and CCL2 were decreased at all postoperative time points. There was differential expression of genes driving protein turnover (IGFN1, FBXW10) in both groups over time and increased expression of PAAF1 in the non-omentectomy group at 12 months. Evidence for the activation of skeletal muscle satellite cells was inferred from the up-regulation of HOXC10. The elevated post-operative expression of 22 small nucleolar RNAs and the decreased expression of the transcription factors JUNB, FOS, FOSB, ATF3 MYC, EGR1 as well as the orphan nuclear receptors NR4A1, NR4A2, NR4A3 suggest dramatic reorganizations at both the cellular and genetic levels. These data indicate that RYGB reduces skeletal muscle inflammation, and removal of omental fat further amplifies this response.

60 APPLIED LIFE SCIENCES↗

Operational Parameters, Considerations, and Design Decisions for Resource-Constrained Ion Trap Mass Spectrometers

Mass spectrometers are increasingly finding applications in new and unique areas, often in situations where key operational resources (i.e. power, weight and size) are limited. One such example is the Mars Organic Molecule Analyzer (MOMA). This instrument is a joint venture between NASA and the European Space Agency (ESA) to develop an ion trap mass spectrometer for chemical analysis on Mars. The constraints on such an instrument are significant as are the performance requirements. While the ideal operating parameters for an ion trap are generally well characterized, methods to maintain analytical performance with limited power and system weight need to be investigated and tested. Methods Experiments have been performed on two custom ion trap mass spectrometers developed as prototypes for the MOMA instrument. This hardware consists of quadrupole ion trap electrodes that are 70% the size of common commercial instrumentation. The trapping RF voltage is created with a custom tank circuit that can be tuned over a range of RF frequencies and is driven using laboratory supplies and amplifiers. The entire instrument is controlled with custom Lab VIEW software that allows a high degree of flexibility in the definition of the scan function defining the ion trap experiment. Ions are typically generated via an internal electron ionization source, however, a laser desorption source is also in development for analysis of larger intact molecules. Preliminary Data The main goals in this work have been to reduce the power required to generate the radio frequency trapping field used in an ion trap mass spectrometer. Generally minimizing the power will also reduce the volume and mass of the electronics to support the instrument. In order to achieve optimum performance, commercial instruments typically utilize RF frequencies in the 1 MHz range. Without much concern for power usage, they simply generate the voltage required to access the mass range of interest. In order to reduce the required RF voltage (and power), operation of the ion trap at lower RF frequencies has been investigated. Surprisingly, the performance of the instrument has only been slightly degraded at RF frequencies all the way down to 500 kHz. Mass resolution is relatively stable to this point and depending on the resonant ejection point used, the peak intensity is also quite stable. To date only masses up to m/z 200 have been fully investigated, however, additional studies are planned to verify the performance with higher mass ions. The lower frequency and voltage should reduce the pseudo potential well depth, eventually affecting the trapping efficiency of the instrument -- effect that could manifest itself in significantly limiting the mass range of trapped ions. Other methods to reduce the RF power while maintaining analytical performance are also under investigation. This includes ion ejection at lower q(sub z) values to access a given mass with a lower RF voltage. The loss of mass resolution at lower q(sub eject) points has been measured and current work is underway to leverage scan speed and the use of non-linear resonances in order to counter this trend. The overall trap performance under this range of operating conditions will be presented with a goal of identifying what trade-offs are acceptable.

Danell, Ryan M.↗

PRIMED for the Future: Purposing Raw Intake for Machine Learning-Enabled Detection (Final Report)

The COVID-19 pandemic demonstrated how a novel, elusive, and diffuse biological threat can engender uncertainty and misinformation, and it underscored the need for flexible analytical modalities agnostic to the identity of biological material. Yet even before the pandemic, recognition of the limitations of the current, list-based approach, which focuses on known pathogens and biotoxins, and of the importance of agent-agnostic biodetection was growing within the biosecurity community. In a 2018 report on “Biodefense in the Age of Synthetic Biology,” for example, the National Academy of Sciences stated that “an overreliance on the Select Agent List is a systematic weakness affecting many aspects of the United States’ current biodefense mitigation capability”. More recently, a group of biodefense researchers proposed the identification and adoption of “bioagent-agnostic signatures (BASs)” as a way of detecting and characterizing not only existing agents but also novel ones, an approach they believe will “enable a more flexible and resilient biodefense posture”. Indeed, the future of biodetection requires us to begin developing novel analytics that can identify anomalies and/or characteristics that indicate a potential threat, whether known or unknown, without looking for a specific signature that has been identified previously. To assess potential threats more rapidly, it is critical to develop agnostic artificial intelligence (AI)/machine learning (ML) systems that can be employed for real-time assessment of the nature and source of a perturbation. Such systems should be multi scale and multi-dimensional, integrating sensor data from a range of biological, chemical, and physical application spaces. Emerging deep learning (DL) models demonstrate exceptional promise for identification of discriminatory features within multi-dimensional datasets. DL models have the capacity to recognize and encode highly complex patterns in a wide range of input data modalities, including images, text, and biological/chemical/physical spectra. As such, they can execute a wide range of assessments and determinations that have traditionally required a human operator. The promise of advances in DL is apparent in the realm of human health and medicine. DL models have been validated for evaluating a variety of clinical threats to human health in a range of contexts, including infection and cancer, and they demonstrated improved performance in predicting stroke relative to human neurologists in some categories of data. Continuously evolving advances in AI/ML are expected to support more efficient evaluation of raw sequence, spectroscopy, and spectrometry data. For instance, recent advances and deployment of large language models (LLM) such as Generative Pre training Transformer (GPT) and Bidirectional Encoder Representations from Transformers (BERT) have already motivated application of these models for biological function prediction. As frameworks such as LLMs become larger and more complex in their representations, their capacity to serve as pre-trained models that can be fine-tuned for biological/biodetection purposes will similarly be amplified. While existing and emerging AI/ML have found broad applicability and use cases in the clinical sciences, development for environmental evaluation and biodetection has been limited. Functionalizing such capabilities for this purpose requires an understanding of the existing technical landscape and how the respective tools and algorithms are currently being employed. This landscape awareness then allows an assessment of the current practical capabilities of existing models and the anticipated requirements and development efforts that will be needed to adapt available algorithms for biodetection applications relevant to DHS. Leveraging expertise in biodetection, ML, and operational biodetection, the effort described in this report is comprised of a systematic landscape assessment (Subtask 2.1), comparative evaluation (Subtask 2.2), and formulation of a value proposition (Subtask 2.3) for the prospect of ML-enabled, agnostic biodetection from raw, or minimally-processed, datasets.

59 BASIC BIOLOGICAL SCIENCES↗

Coherent soft X-ray pulses from an echo-enabled harmonic generation free-electron laser

It is known that X-ray free-electron lasers (FELs), which amplify light emitted by a relativistic electron beam, are extending nonlinear optical techniques to shorter wavelengths, adding element specificity by exciting and probing electronic transitions from core levels. These techniques would benefit tremendously from having a stable FEL source, generating spectrally pure and wavelength-tunable pulses. Here, we show that such requirements can be met by operating the FEL in the so-called echo-enabled harmonic generation (EEHG) configuration. Here, two external conventional lasers are used to precisely tailor the longitudinal phase space of the electron beam before emission of X-rays. We demonstrate high-gain EEHG lasing producing stable, intense, nearly fully coherent pulses at wavelengths as short as 5.9 nm (~211 eV) at the FERMI FEL user facility. Low sensitivity to electron-beam imperfections and observation of stable, narrow-band, coherent emission down to 2.6 nm (~474 eV) make the technique a prime candidate for generating laser-like pulses in the X-ray spectral region, opening the door to multidimensional coherent spectroscopies at short wavelengths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High power microwave source with a three dimensional printed metamaterial slow-wave structure

For over the last decade, the concept of metamaterials has led to new approaches for considering the interaction of radiation with complex structures. However, practical manifestations of such a device operating at high power densities have proven difficult to achieve due to the resonant nature of metamaterials and the resultant high electric fields, which place severe constraints on manufacturing the slow wave structures. In this paper, we describe the first experimental manifestation of a high power microwave device utilizing a metallic slow wave structure (metamaterial-like) fabricated using additive manufacturing. The feasibility of utilizing additive manufacturing as a technique for building these relatively complicated structures has thus been demonstrated. The MW class microwave source operates in the C-band and shows frequency tunablility with electron beam voltage. The basic electromagnetic characteristics of this device, the construction using additive manufacturing, and the basic performance as a microwave oscillator are considered. Due to the tunable nature of the device, it shows promise not only as an oscillator but also as a microwave amplifier. Therefore, the dispersive characteristics and a discussion of the anticipated gain is included as it relates to an amplifier configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lasing properties of active medium based on sulforhodamine 101 incorporated into commercial polyurethane compound

The lasing properties of polymer matrices based on commercial polyurethane compound activated by sulforhodamine 101 dye are studied. Lasing with an efficiency of 26 % and pulse energy of 76 mJ is obtained using microsecond transverse pumping at a wavelength of 587 nm. The service life (time of operation to a decrease in the output energy by 50 % upon excitation by 0.3 J cm{sup -2} pulses) amounts to 2500 pulses. A particular attention is given to the bichromatic lasing spectra of the samples tested. Based on the experimental data a model explaining the two-band emission spectrum is proposed and discussed. (lasers and amplifiers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The revolution in data gathering systems

This paper gives a review of the data-acquisition systems used in NASA's wind tunnels from the 1950's to the present as a basis for assessing the impact of minicomputers and microcomputers on data acquisition and processing. The operation and disadvantages of wind-tunnel data systems are summarized for the period before 1950, the early 1950's, the early and late 1960's, and the early 1970's. Some significant advances discussed include the use or development of solid-state components, minicomputer systems, large central computers, on-line data processing, autoranging DC amplifiers, MOS-FET multiplexers, MSI and LSI logic, computer-controlled programmable amplifiers, solid-state remote multiplexing, integrated circuits, and microprocessors. The distributed system currently in use with the 40-ft by 80-ft wind tunnel at Ames Research Center is described in detail. The expected employment of distributed systems and microprocessors in the next decade is noted.

Cambra, J. M.↗

Qualification and Performance of a High-Efficiency Laser Transmitter for Deep-Space Optical Communications

A high-power Laser Transmitter Assembly (LTA) was developed to support the Deep Space Optical Communications (DSOC) technology demonstration being developed by the Jet Propulsion Laboratory. NASA’s Psyche Mission plans to host the DSOC flight subsystem for testing space-to-ground high-bandwidth laser communications en route to the 16 Psyche asteroid. We review the design, performance, and qualification of the LTA Engineering Model and Flight Model (EM and FM) delivered to JPL. The LTA uses a master-oscillator power amplifier (MOPA) design and delivers up to 4.5 W at 1550 nm, with a highly efficient, cladding-pumped, polarization-maintaining erbium-ytterbium fiber amplifier. The master oscillator generates a range of pulse widths and repetition rates to support modulation formats from 16- to 128-PPM for optical data transmission at >100 Mbps. The LTA was designed for high reliability and radiation hardness, and includes redundant signal and pumping paths to reduce single points of failure, hardware interlocks to ensure safe operation and protection against damage, closed-loop control of optical power, and detailed health and status via telemetry. The LTA EM and FM were subjected to unit-appropriate space qualification testing. We describe the performance testing of the EM and FM, for the characterization of key metrics such as wavelength stability, signal linewidth, optical pulse width, jitter, and extinction ratio, and polarization extinction ratio. The management of optical nonlinearities (self-phase modulation, Brillouin scattering, or pulse-to-pulse energy variation), which could result in an optical link penalty or damage to the LTA, is also detailed, and factors affecting the power efficiency are discussed.

Jaques, J.↗

Infrastructure Development of Single Cell Testing Capability at A0 Facility

The objective of this technical note is to document the details of the infrastructure development process that was realized at the A0 photo injector facility to establish RF cold testing capability for 1.3 GHz superconducting niobium single cell cavities. The activity began the last quarter of CY 2006 and ended the first quarter of CY 2009. The whole process involved addressing various aspects such as design of vertical insert and lifting fixture, modification of existing RF test station and design of new couplers, development of a Temperature Mapping (T-Map) system, radiation considerations for the test location (north cave), update of existing High Pressure Rinse (HPR) system, preparation of necessary safety documents and eventually obtaining an Operational Readiness Clearance (ORC). Figure 1 illustrates the various components of the development process. In the past, the north cave test station at A0 has supported the cold testing 3.9 GHz nine cell and single cell cavities, thus some of the components were available for use and some needed modification. The test dewar had the capacity to accommodate 1.3 GHz single cells although a new vertical insert that could handle both cavity types (1.3 and 3.9 GHz) had to be designed. The existing cryogenic system with an average capacity of {approx} 0.5 g/sec was deemed sufficient. The RF system was updated with broadband components and an additional amplifier with higher power capacity to handle higher gradients usually achieved in 1.3 GHz cavities. The initial testing phase was arbitrated to proceed with fixed power coupling. A new temperature mapping system was developed to provide the diagnostic tool for hot spot studies, quench characterization and field emission studies. The defining feature of this system was the use of diode sensors instead of the traditional carbon resistors as sensing elements. The unidirectional current carrying capacity (forward bias) of the diodes provided for the ease of multiplexing of the system, thus substantially reducing the number of cables required to power the sensors. The high gradient capacity of the 1.3 GHz cavities required a revision of the radiation shielding and interlocks. The cave was updated as per the recommendations of the radiation safety committee. The high pressure rinse system was updated with new adapters to assist the rinsing 1.3 GHz single cell cavities. Finally, a proposal for cold testing 1.3 GHz single cell cavities at A0 north cave was made to the small experiments approval committee, radiation safety committee and the Tevatron cryogenic safety sub-committee for an operational readiness clearance and the same was approved. The project was classified under research and development of single cell cavities (project 18) and was allocated a budget of $200,000 in FY 2007.

43 PARTICLE ACCELERATORS↗

AIACHNE's contribution for Nuclear Energy Agency Working Party on International Nuclear Data Evaluation Co-operation Subgroup 50

The AIACHNE (AI/ML Informed cAlifornium CHi Nuclear data Experiment) project aims at designing an experiment for the 252 Cf Prompt Fission Neutron Spectrum (PFNS) that explores systematic biases in an experimental database retrieved from the EXFOR databases. To that end, machine learning (ML) methods were applied to pint-point measurement features likely related to bia. From that information, we selected a feature that should be explored by the AIACHNE experiment. Measurement features are metadata encapsulating all pertinent information about the physical measurement and analysis techniques. Examples are, for instance, what neutron and fission detectors were used for the physical metadata, and what background reduction techniques were employed for analysis techniques. Such metadata were retrieved both from EXFOR entries as well as the literature of data sets described in detail in Ref. [2]. The prerequisite for applying machine learning techniques is casting the metadata into a format that can be parsed by the algorithm. This step might seem trivial but requires to find a unique language where metadata that carry the same physics meaning across several experiments must have the same identifier. One example is, for instance, the neutron detector. As seen in Figure 1, the machine learning code identified the use of 6 Li detectors as being related to bias in some datasets of the AIACHNE 252 Cf PFNS experimental database. In fact, here are several experiments that used neutron detectors containing 6Li in the database, for instance for the example below. EXFOR format has a unique keywords describing detectors such as “SCIN” or “GLASD”. One may think that these keywords are already sufficient descriptors for ML to uniquely find an issue. However, “SCIN” (used for [3, 4]) and “GLASD” (used for [5]) fail to inform the algorithm what is the active material in the detector. And, the key common issue leading to bias in 252 Cf related to neutron detectors is not whether it is a glass detector or a scintillator. No, the issue is that 6 Li was within both detector types and that even small mistakes in the detector response functions around approximately 200 keV are amplified by the 6 Li(n,α) resonance there leading to bias in data as highlighted in Fig. 1 and Ref. [1]. Hence, the features describing the neutron detector must call out the active material in the detector, rather than the existing EXFOR detector keyword, that the ML algorithm can find physically meaningful features related to bias. The AIACHNE team used a precursor of the WPEC (Working Party on International Nuclear Data Evaluation Co-operation) SG(Subgroup)-50 format to store the metadata for the ML analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Model experiment of magnetic field amplification in laser-produced plasmas via the Richtmyer-Meshkov instability

A model experiment of magnetic field amplification (MFA) via the Richtmyer-Meshkov instability (RMI) in supernova remnants (SNRs) was performed using a high-power laser. In order to account for very-fast acceleration of cosmic rays observed in SNRs, it is considered that the magnetic field has to be amplified by orders of magnitude from its background level. A possible mechanism for the MFA in SNRs is stretching and mixing of the magnetic field via the RMI when shock waves pass through dense molecular clouds in interstellar media. In order to model the astrophysical phenomenon in laboratories, there are three necessary factors for the RMI to be operative: a shock wave, an external magnetic field, and density inhomogeneity. By irradiating a double-foil target with several laser beams with focal spot displacement under influence of an external magnetic field, shock waves were excited and passed through the density inhomogeneity. Radiative hydrodynamic simulations show that the RMI evolves as the density inhomogeneity is shocked, resulting in higher MFA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intersubband transitions in nonpolar and semipolar III-nitrides: Materials, devices, and applications

In the last two decades, the third-generation wide bandgap semiconductor III-nitrides have revolutionized a myriad of electronic and photonic devices and applications, including power electronics, extreme-environment electronics, RF amplifiers, and optoelectronics such as light-emitting diodes and laser diodes. Recently, III-nitride heterostructures (e.g., AlGaN/GaN) based intersubband transition (ISBT) has garnered considerable research interest for infrared (IR), terahertz (THz), and ultrafast optoelectronics (e.g., photodetectors and quantum cascade lasers) due to its large conduction band offset, large optical phonon energy, and promising room-temperature operation. This paper presents a comprehensive review on the recent progress and challenges of III-nitrides based ISBT from the perspectives of materials, structures, devices, and applications, with a focus on nonpolar and semipolar III-nitrides. Various device structures have been demonstrated for III-nitrides based ISBT, including quantum wells, dots, and wires, among which AlGaN/GaN quantum wells are the most widely used. The effects of device parameters, crystal orientations, and doping on the ISBT properties of AlGaN/GaN quantum wells are discussed. Although the room-temperature operation is still elusive, theoretical and experimental studies show that nonpolar and semipolar III-nitrides based ISBT exhibits tunable ISBT wavelength from far-IR to THz spectral range with higher efficiency compared with polar c-plane ISBT. This review can serve as a gateway to and an important reference for the recent progress and challenges of III-nitrides based ISBT and its potential applications in sensing, communication, ultrafast optoelectronics, and integrated photonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Closed-Loop Motor-Speed Control

Electronic motor-speed control circuit designed to operate in electrically noisy environment. Includes optoelectronic pick-up device, placed inside motor housing to provide speed feedback signal. Automatically maintains speed motor at commanded value. Measures speed of motor in terms of frequency of pulses of infrared light chopped by fan blades of motor. Difference between measured and commanded speeds serves as control signal for external amplifier driving motor. Major advantage of circuit is low cost.

Smith, Matthew A.↗

120 Watt Split-Mount 30 GHz Amplifier for the Advanced Communications Technology Satellite

This paper describes an amplifier for a Ka-band communication system. The amplifier consists of two units. The radio frequency (RF) unit is mounted at the antenna to provide power to the antenna, while the power supply unit is located 12 meters away in a control station. The two units are connected by a waveguide run and a set of umbilical cables to provide all the necessary inputs for the operation and protection of the RF unit. Specifications and actual performance data are presented and discussed. Special features of each unit to meet the specifications are described in detail.

Lazar, John↗

Signal Digitizer and Cross-Correlation Application Specific Integrated Circuit

According to one embodiment, a cross-correlator comprises a plurality of analog front ends (AFEs), a cross-correlation circuit and a data serializer. Each of the AFEs comprises a variable gain amplifier (VGA) and a corresponding analog-to-digital converter (ADC) in which the VGA receives and modifies a unique analog signal associates with a measured analog radio frequency (RF) signal and the ADC produces digital data associated with the modified analog signal. Communicatively coupled to the AFEs, the cross-correlation circuit performs a cross-correlation operation on the digital data produced from different measured analog RF signals. The data serializer is communicatively coupled to the summing and cross-correlating matrix and continuously outputs a prescribed amount of the correlated digital data.

Baranauskas, Dalius↗

Model-Based Investigation of Multi-Fault Interactions and Performance Degradation in Residential Heat Pump Systems

Faults in heat pump systems can significantly degrade performance, reduce efficiency, and accelerate component wear, leading to higher operating costs and maintenance demands. While numerous studies have investigated the impact of individual faults, the interactions between multiple concurrent faults remain insufficiently understood, despite their common occurrence in real-world operation. This study conducts a comprehensive simulation analysis of multiple simultaneous faults in a vapor compression heat pump using a validated heat pump design model (HPDM) tool. Detailed component-level modeling methods are implemented to examine performance sensitivity under combinations of refrigerant flow and heat exchanger faults. The results reveal complex fault interactions that can mask or amplify system deviations, challenging conventional diagnostic approaches. Findings from this work provide meaningful insights for the development of more robust fault detection and diagnosis algorithms, supporting improved reliability and energy efficiency in next-generation heat pump technologies.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗