Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Intracranial Effects of Intermittent Lower Body Negative Pressure with Head Down Tilt Bed Rest: Comparison to Upright Posture

INTRODUCTION Spaceflight-associated neuro-ocular syndrome (SANS) affects a majority of astronauts during long-duration spaceflight. SANS is hypothesized to result from an unrelenting headward fluid shift that occurs in the microgravity environment. Altered intracranial structure and physiology documented in spaceflight and head-down tilt (HDT) experiments(1, 2) are also theorized to be related to chronic headward fluid shift and thereby can provide an independent quantitative assessment related to this mechanism. As a potential countermeasure, lower body negative pressure (LBNP) applied in the supine posture has shown efficacy in reducing headward fluid shift(3). However, it remains unknown if intermittent LBNP simulating daily upright posture fluid redistribution can mitigate SANS and intracranial changes associated with long-duration spaceflight. The goal of this study was to quantify the effects of daily application of LBNP or daily exposure to the upright posture on intracranial structure and physiology during long-term HDT in order to evaluate the potential efficacy of LBNP as a countermeasure to SANS. METHODS 22 healthy volunteers (11 men; 11 women; mean age = 35 years (SD=9.2)(age range = 24 to 52 years); mean BMI = 24.0 kg/m2 (SD=2.8)) completed an MRI study performed at the German Aerospace Facility in Cologne, Germany. Strict six-degree head-down tilt (HDT) bedrest was used as a spaceflight analog to induce a continuous headward fluid shift for 30 days. The subjects were divided equally into two groups of interventions: 1) LBNP for 3-hour sessions twice daily and 2) seated position for 3-hour sessions twice daily. Interventions were divided into morning and afternoon sessions for both groups. The LBNP intervention was maintained at 25 mmHg  2 mmHg. Pulse-gated MRI phase-contrast flow imaging was used to quantify cerebral artery stroke volume (CASV) and peak-to-peak cerebral spinal fluid (CSF) velocity (CSFVp-p) within the cerebral aqueduct. A 3D T1-MPRAGE sequence was used to quantify volumetric changes of the brain and intracranial CSF spaces using MRI Cloud software. MRI acquisitions were obtained at baseline (BDC, supine posture), 15 days into HDT (HDT15), 29 days into HDT (HDT29), and 12 days after recovery (R12, supine posture). The data were analyzed by a mixed model, which included intervention, time (four nominal levels BDC, HDT15, HDT29, R12), and intervention-time interaction as the fixed effects and included subject as a random effect. RESULTS Compared to BDC there was no statistically significant difference in CASV and CSFVp-p during HDT except for CASV at HDT29 (seated group) where there was a 1.7 mL (12%) decrease (P<0.01). Compared to BDC there was a statistically significant increase in intracranial volume (ICV; ICV = white matter + gray matter + CSF) for both interventions at HDT15 (Δ13 mL, 0.9 % (LBNP group); Δ15 mL, 1.0%, (seated group)) and HDT29 (Δ19 mL, 1.2%, (LBNP group); Δ23 mL, 1.5%) (seated group)) (All Ps<.001). Compared to baseline, lateral ventricular volume increased at HDT15 (Δ0.9 mL, 5.5%) and HDT29 (Δ1.8 mL, 10%)) for LBNP only (P=.001 for each). During HDT, white matter volume remained stable compared to baseline for both interventions. There were no significant intervention effects in the overall response to HDT (All Ps >.2). CONCLUSION LBNP had a similar response to the seated posture during 29 days of HDT. Although there was an increase in ICV and lateral ventricular volume with HDT there was no change in intracranial physiological parameters with LBNP suggesting an overall diminished response to the long-term effects of HDT. The lack of any significant increase in white matter volume during HDT with LBNP suggests maintenance of cerebral interstitial fluid transport. Final conclusions are pending the data collection for the control group (no intervention) which will be completed in 2023.

Larry A Kramer↗

Structure function monitor

Methods and apparatus for a structure function monitor provide for generation of parameters characterizing a refractive medium. In an embodiment, a structure function monitor acquires images of a pupil plane and an image plane and, from these images, retrieves the phase over an aperture, unwraps the retrieved phase, and analyzes the unwrapped retrieved phase. In an embodiment, analysis yields atmospheric parameters measured at spatial scales from zero to the diameter of a telescope used to collect light from a source.

47 OTHER INSTRUMENTATION↗

Talbot-Lau X-ray Phase-Contrast Research at Johns Hopkins

The Talbot-Lau (T-L) grating interferometer enables X-ray differential phase-contrast (DPC) imaging with low coherence conventional X-ray tubes, being thus attractive for medical and other applications. We studied several variations of the conventional T-L interferometer design. First, to extend the T-L method to high X-ray energy we developed a symmetric interferometer having gratings inclined at a glancing angle (GAI). This simple setup enables achieving high fringe contrast up to 80 kVp or more. The high GAI contrast in turn enabled demonstrating for the first time DPC-CT of soft tissues with clinically compatible X-ray dose and energy. Industrial and security applications of the GAI appear also possible. Further on, we studied high magnification T-L interferometry for electron density diagnostic in high energy density plasmas. High magnification refraction radiography with laser driven backlighters can help understand inertial confinement fusion experiments for instance. For plasma diagnostic using a single radiographic image we develop Moiré fringe deflectometry. We also extended the T-L method below 10 keV using membrane and free standing gratings. Lastly, we explored using grazing incidence micro-periodic mirrors instead of gratings in the T-L interferometers. These enable in principle achieving very small interferometer periods over a broad energy range, at the price of a narrow field of view in one dimension. The possibility of using these designs for DPC imaging of materials under extreme conditions will also be examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric Analysis of Respiratory-Gated Radiotherapy for Hepatocellular Carcinoma

The purpose of this study was to define individualized internal target volume (ITV) for hepatocellular carcinoma (HCC) using 4D computed tomography (4DCT), and to determine the geometric and dosimetric benefits of respiratory gating. Gross tumor volumes (GTVs) were contoured on 10 respiratory phases of 4DCT images for 12 patients with HCC. Three treatment plans were prepared using different planning target volumes (PTVs): (1) PTV{sub 3D}, derived from a single helical clinical target volume (CTV) plus conventional margins; (2) PTV{sub 10phases}, derived from ITV{sub 10phases}, which encompassed all 10 CTVs plus an isotropic margin of 0.8 cm; (3) PTV{sub gating}, derived from ITV{sub gating}, which encompassed three CTVs within gating-window at end-expiration plus an isotropic margin of 0.8 cm. The PTV{sub 3D} was the largest volume for all patients. The ITV-based plans and gating plans spared more normal tissues than 3D plans, especially the liver. Without increasing normal tissue complication probability of the 3D plans, the ITV-based plans allowed for increasing the calculated dose from 50.8 Gy to 54.7 Gy on average, and the gating plans could further escalate the dose to 58.5 Gy. Compared with ITV-based plans, the dosimetric gains with gating plan strongly correlated with GTV mobility in the craniocaudal direction. The ITV-based plans can ensure target coverage with less irradiation of normal tissues compared with 3D plans. Respiratory-gated radiotherapy can further reduce the target volumes to spare more surrounding tissues and allow dose escalation, especially for patients with tumor mobility >1 cm.

61 RADIATION PROTECTION AND DOSIMETRY↗

Inferring Positions of Tumor and Nodes in Stage III Lung Cancer From Multiple Anatomical Surrogates Using Four-Dimensional Computed Tomography

Purpose: To investigate the feasibility of modeling Stage III lung cancer tumor and node positions from anatomical surrogates. Methods and Materials: To localize their centroids, the primary tumor and lymph nodes from 16 Stage III lung cancer patients were contoured in 10 equal-phase planning four-dimensional (4D) computed tomography (CT) image sets. The centroids of anatomical respiratory surrogates (carina, xyphoid, nipples, mid-sternum) in each image set were also localized. The correlations between target and surrogate positions were determined, and ordinary least-squares (OLS) and partial least-squares (PLS) regression models based on a subset of respiratory phases (three to eight randomly selected) were created to predict the target positions in the remaining images. The three-phase image sets that provided the best predictive information were used to create models based on either the carina alone or all surrogates. Results: The surrogate most correlated with target motion varied widely. Depending on the number of phases used to build the models, mean OLS and PLS errors were 1.0 to 1.4 mm and 0.8 to 1.0 mm, respectively. Models trained on the 0%, 40%, and 80% respiration phases had mean ({+-} standard deviation) PLS errors of 0.8 {+-} 0.5 mm and 1.1 {+-} 1.1 mm for models based on all surrogates and carina alone, respectively. For target coordinates with motion >5 mm, the mean three-phase PLS error based on all surrogates was 1.1 mm. Conclusions: Our results establish the feasibility of inferring primary tumor and nodal motion from anatomical surrogates in 4D CT scans of Stage III lung cancer. Using inferential modeling to decrease the processing time of 4D CT scans may facilitate incorporation of patient-specific treatment margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced Imaging Optics Utilizing Wavefront Coding

Image processing offers a potential to simplify an optical system by shifting some of the imaging burden from lenses to the more cost effective electronics. Wavefront coding using a cubic phase plate combined with image processing can extend the system's depth of focus, reducing many of the focus-related aberrations as well as material related chromatic aberrations. However, the optimal design process and physical limitations of wavefront coding systems with respect to first-order optical parameters and noise are not well documented. We examined image quality of simulated and experimental wavefront coded images before and after reconstruction in the presence of noise. Challenges in the implementation of cubic phase in an optical system are discussed. In particular, we found that limitations must be placed on system noise, aperture, field of view and bandwidth to develop a robust wavefront coded system.

97 MATHEMATICS AND COMPUTING↗

Clinical evaluations of an amplitude-based binning algorithm for 4DCT reconstruction in radiation therapy

Purpose: Phase-binning algorithms are commonly utilized in 4DCT image reconstruction for characterization of tumor or organ shape and respiration motion, but breathing irregularities occurring during 4DCT acquisition can cause considerable image distortions. Recently, amplitude-binning algorithms have been evaluated as a potential improvement to phase-binning algorithms for 4DCT image reconstruction. The purpose of this study was to evaluate the performance of the first commercially available on-line retrospective amplitude-binning algorithm for comparison to the traditional phase-binning algorithm. Methods: Both phantom and clinical data were used for evaluation. A phantom of known geometry was mounted on a 4D motion platform programmed with seven respiratory waves (two computer generated and five patient trajectories) and scanned with a Philips Brilliance Big bore 16-slice CT simulator. 4DCT images were reconstructed using commercial amplitude- and phase-binning algorithms. Image quality of the amplitude- and phase-binned image sets was compared by evaluation of shape and volume distortions in reconstructed images. Clinical evaluations were performed on 64 4DCT patient image sets in a blinded review process. The amplitude- and phase-binned 4DCT maximum intensity projection (MIP) images were further evaluated for 28 stereotactic body radiation therapy (SBRT) cases of total 64 cases. A preliminary investigation of the effects of respiratory amplitude and pattern irregularities on motion artifact severity was conducted. Results: The phantom experiments illustrated that, as expected, maximum inhalation occurred at the 0% amplitude and maximum exhalation occurred at the 50% amplitude of the amplitude-binned 4DCT image sets. The phantom shape distortions were more severe in the images reconstructed from the phase-binning algorithm. In the clinical study, compared to the phase-binning algorithm, the amplitude-binning algorithm yielded fewer or less severe motion artifacts in 37.5% of the cases (24/64), comparable artifacts in 54.7% of the cases (35/64), and slightly greater artifacts in 7.8% of the cases (5/64). Evaluation of SBRT cases demonstrated that the reconstructed tumor sizes and locations were comparable in 96% (1/28) of the MIP image pairs generated from both amplitude- and phase-binning algorithms. In this case the amplitude-binned image set rendered a smaller tumor size, which was likely due to very shallow respiratory amplitudes occurring over several breathing cycles. Conclusions: Overall, the amplitude-binning algorithm for 4DCT reconstruction reduced the severity of tumor distortion and image artifacts compared to the phase-binning algorithm. However, the full range of motion may not be characterized using amplitude-binning algorithms. Despite superior performance, amplitude binning can still be susceptible to motion artifacts caused by large variations in amplitude of respiratory waves.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Modal Analysis Using Phase Quantities from Phase-Based Motion Processing and Motion Magnification

Phase-based motion processing and the associated Motion Magnification that it enables has become popular not only for the striking videos that it can produce of traditionally stiff structures visualized with very large deflections, but also for its ability to pull information out of the noise floor of images so that they can be processed with more traditional optical techniques such as digital image correlation or feature tracking. While the majority of papers in the literature have utilized the Phase-based Image Processing approach as a pre-processor for more quantitative analyses, the technique itself can be used directly to extract modal parameters from an image, noting that the extracted phases are proportional to displacements in the image. Therefore, once phases are extracted, they can be fit using traditional experimental modal analysis techniques. This produces a mode “shape” where the degrees of freedom are phases instead of physical motions. These phases can be scaled to produce on-image visualizations of the mode shapes, rather than operational shapes produced by bandpass filtering. Modal filtering techniques can also be used to visualize motions from an environment on an image using the modal phases as a basis for the expansion.

47 OTHER INSTRUMENTATION↗

High energy x-ray phase contrast CT using glancing-angle grating interferometers

Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code the authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data-driven high-fidelity 2D microstructure reconstruction via non-local patch-based image inpainting

Microstructure reconstruction problems are usually limited to the representation with finitely many number of phases, e.g. binary and ternary. However, images of microstructure obtained through experimental, for example, using microscope, are often represented as a RGB or grayscale image. Because the phase-based representation is discrete, more rigid, and provides less flexibility in modeling the microstructure, as compared to RGB or grayscale image, there is a loss of information in the conversion. In this paper, a microstructure reconstruction method, which produces images at the fidelity of experimental microscopy, i.e. RGB or grayscale image, is proposed without introducing any physics-based microstructure descriptor. Furthermore, the image texture is preserved and the microstructure image is represented with continuous variables (as in RGB or grayscale images), instead of binary or categorical variables, which results in a high-fidelity image of microstructure reconstruction. The advantage of the proposed method is its quality of reconstruction, which can be applied to any other binary or multiphase 2D microstructure. The proposed method can be thought of as a subsampling approach to expand the microstructure dataset, while preserving its image texture. Moreover, the size of the reconstructed image is more flexible, compared to other machine learning microstructure reconstruction method, where the size must be fixed beforehand. In addition, the proposed method is capable of joining the microstructure images taken at different locations to reconstruct a larger microstructure image. A significant advantage of the proposed method is to remedy the data scarcity problem in materials science, where experimental data is scare and hard to obtain. The proposed method can also be applied to generate statistically equivalent microstructures, which has a strong implication in microstructure-related uncertainty quantification applications. The proposed microstructure reconstruction method is demonstrated with the UltraHigh Carbon Steel micrograph DataBase (UHCSDB).

97 MATHEMATICS AND COMPUTING↗

Quantitative phase retrieval with arbitrary pupil and illumination

We present a general algorithm for combining measurements taken under various illumination and imaging conditions to quantitatively extract the amplitude and phase of an object wave. The algorithm uses the weak object transfer function, which incorporates arbitrary pupil functions and partially coherent illumination. The approach is extended beyond the weak object regime using an iterative algorithm. Finally, we demonstrate the method on measurements of Extreme Ultraviolet Lithography (EUV) multilayer mask defects taken in an EUV zone plate microscope with both a standard zone plate lens and a zone plate implementing Zernike phase contrast.

97 MATHEMATICS AND COMPUTING↗

Phase-contrast diffuse optical tomography for in vivo breast imaging: a two-step method

We present a two-step reconstruction method that can qualitatively and quantitatively improve the reconstruction of tissue refractive index (RI) distribution by phase-contrast diffuse optical tomography (PCDOT). In this two-step method, we first recover the distribution of tissue absorption and scattering coefficients by conventional diffuse optical tomography to obtain the geometrical information of lesions, allowing the incorporation of geometrical information as a priori in the PCDOT reconstruction using a locally refined mesh. The method is validated by a series of phantom experiments and evaluated using in vivo data from 42 human subjects. The results demonstrate clear contrast of RI between the lesion and the surroundings, making the image interpretation straightforward. The sensitivity and specificity from these 42 cases are both 81% when RI is used as an imaging parameter for distinguishing between malignant and benign lesions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ptychographic x-ray imaging of surfaces on crystal truncation rod

Ptychography is a high-resolution imaging technique, which does not require lenses for image magnification and which provides phase contrast with high sensitivity. Here, we propose to use x-ray ptychography for the imaging of surface structure in crystalline samples. We show that ptychography can be used to image atomic step structures using coherent diffraction patterns recorded along the crystal truncation rod of a crystal surface. In a proof-of-concept experiment on a Pt (111) sample, we present ptychographic reconstructions showing features consistent with surface steps. Due to the penetration power of x-rays, this method could find interesting applications for the study of surface structures under buried interfaces or in harsh environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hybrid Architecture Active Wavefront Sensing and Control

A method was developed for performing relatively high-speed wavefront sensing and control to overcome thermal instabilities in a segmented primary mirror telescope [e.g., James Webb Space Telescope (JWST) at L2], by using the onboard fine guidance sensor (FGS) to minimize expense and complexity. This FGS performs centroiding on a bright star to feed the information to the pointing and control system. The proposed concept is to beam split the image of the guide star (or use a single defocused guide star image) to perform wavefront sensing using phase retrieval techniques. Using the fine guidance sensor star image for guiding and fine phasing eliminates the need for other, more complex ways of achieving very accurate sensing and control that is needed for UV-optical applications. The phase retrieval occurs nearly constantly, so passive thermal stability over fourteen days is not required. Using the FGS as the sensor, one can feed segment update information to actuators on the primary mirror that can update the primary mirror segment fine phasing with this frequency. Because the thermal time constants of the primary mirror are very slow compared to this duration, the mirror will appear extremely stable during observations (to the level of accuracy of the sensing and control). The sensing can use the same phase retrieval techniques as the JWST by employing an additional beam splitter, and having each channel go through a weak lens (one positive and one negative). The channels can use common or separate detectors. Phase retrieval can be performed onboard. The actuation scheme would include a coarse stage able to achieve initial alignment of several millimeters of range (similar to JWST and can use a JWST heritage sensing approach in the science camera) and a fine stage capable of continual updates.

Feinberg, Lee↗

High-resolution projection image reconstruction of thick objects by hard x-ray diffraction microscopy

Hard x-ray diffraction microscopy enables us to observe thick objects at high spatial resolution. The resolution of this method is limited, in principle, by only the x-ray wavelength and the largest scattering angle recorded. As the resolution approaches the wavelength, the thickness effect of objects plays a significant role in x-ray diffraction microscopy. In this paper, we report high-resolution hard x-ray diffraction microscopy for thick objects. We used highly focused coherent x rays with a wavelength of {approx}0.1 nm as an incident beam and measured the diffraction patterns of a {approx}150-nm-thick silver nanocube at the scattering angle of {approx}3 deg. We observed a characteristic contrast of the coherent diffraction pattern due to only the thickness effect and collected the diffraction patterns at nine incident angles so as to obtain information on a cross section of Fourier space. We reconstructed a pure projection image by the iterative phasing method from the patched diffraction pattern. The edge resolution of the reconstructed image was {approx}2 nm, which was the highest resolution so far achieved by x-ray microscopy. The present study provides us with a method for quantitatively observing thick samples at high resolution by hard x-ray diffraction microscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Turbulence structure in oscillating channel flow.

The structure of turbulence in an oscillating channel flow with near-sinusoidal fluctuations in bulk velocity is investigated. Phase-locked particle-image velocimetry data in the streamwise/wall-normal plane are interrogated to reveal the phase-modulation of two-point velocity correlation functions and of linear stochastic estimates of the velocity fluctuation field given the presence of a vortex in the logarithmic region of the boundary layer. The results reveal the periodic modulation of turbulence structure between large-scale residual disturbances, relaminarization during periods of strong acceleration, and a quasi-steady flow with evidence of hairpin vortices which is established late in the acceleration phase and persists through much of the deceleration period.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging Field–Driven Melting of a Molecular Solid at the Atomic Scale

Solid–liquid phase transitions are basic physical processes, but atomically resolved microscopy has yet to capture their full dynamics. A new technique is developed for controlling the melting and freezing of self–assembled molecular structures on a graphene field–effect transistor (FET) that allows phase–transition behavior to be imaged using atomically resolved scanning tunneling microscopy. This is achieved by applying electric fields to 2,3,5,6–tetrafluoro–7,7,8,8–tetracyanoquinodimethane–decorated FETs to induce reversible transitions between molecular solid and liquid phases at the FET surface. Nonequilibrium melting dynamics are visualized by rapidly heating the graphene substrate with an electrical current and imaging the resulting evolution toward new 2D equilibrium states. An analytical model is developed that explains observed mixed–state phases based on spectroscopic measurement of solid and liquid molecular energy levels. The observed nonequilibrium melting dynamics are consistent with Monte Carlo simulations.

36 MATERIALS SCIENCE↗