Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

First data with the Hybrid Array of Gamma Ray Detector (HAGRiD)

Here, the structure of nuclei provides insight into astrophysical reaction rates that are difficult to measure directly. These studies are often performed with transfer reactions and β-decay measurements. These experiments benefit from particle-γ coincidence measurements which provide information beyond that of particle detection alone. The Hybrid Array of Gamma Ray Detectors (HAGRiD) of LaBr 3 (Ce) scintillators has been designed with this purpose in mind. The design of the array permits it to be coupled with particle detector systems, such as the Oak Ridge Rutgers University Barrel Array (ORRUBA) of silicon detectors and the Versatile Array of Neutron Detectors at Low Energy (VANDLE). It is also designed to operate with the Jet Experiments in Nuclear Structure and Astrophysics (JENSA) advanced target system. HAGRiD’s design avoids compromising the charged-particle angular resolution due to compact geometries which are often used to increase the γ efficiency in other systems. First experiments with HAGRiD coupled to VANDLE as well as ORRUBA and JENSA are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NOvA Test Beam Program

NOvA is a two-detector long-baseline neutrino oscillation experiment which aims to make a determination of the neutrino mass hierarchy, the octant of ${\theta}_{23}$, and measure possible CP violation. The NOvA Test Beam program consists of a scaled-down NOvA detector placed in a beamline capable of delivering 0.3 - 2.0 GeV/c protons, electrons, pions, and kaons. The beamline detectors provide us with particle identification and momentum measurements so we can study our detector technology with known inputs. Studying these particles will provide us a more detailed understanding of our calibration, detector response, and energy scale, which are some of the largest sources of systematic uncertainty in NOvA analyses. We will also collect a selection of single-particle data events for training particle identification algorithms. I will present the current status of the NOvA Test Beam program and discuss plans for data taking and analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutral particle background in cosmic ray telescopes composed of silicon solid state detectors

The energy loss-spectrum of secondary charged particles produced by the interaction of gamma-rays and energetic neutrons in silicon solid state detectors has been measured with a satellite-borne cosmic ray telescope. In the satellite measurements presented here two distinct neutral background effects are identified: secondary protons and alpha particles with energies of about 2 to 100 MeV produced by neutron interactions, and secondary electrons with energies of about 0.2 to 10 MeV produced by X-ray interactions. The implications of this neutral background for satellite measurements of low energy cosmic rays are discussed, and suggestions are given for applying these results to other detector systems in order to estimate background contamination and optimize detector system design.

Mewaldt, R. A.↗

Performance assessment after long-term irradiation of ATLAS Micromegas detectors using 120 GeV muons at the Gamma Irradiation Facility at CERN

The ATLAS muon spectrometer will face an increased particle rate as a result of the increased instantaneous luminosity expected during the High-Luminosity LHC (HL-LHC) upgrade. The HL-LHC will provide a luminosity of $\mathscr{L}$ = 7.5 × 10 34 cm −2 s −1 and 3000 fb −1 of integrated luminosity in 10 years, about 9 times more data of the ones so far collected by the ATLAS experiment. Micromegas chambers are used in the New Small Wheel(s), the first forward muon spectrometer station, to provide tracking and triggering at the intense particle rates expected. The detectors are operated with a ternary gas mixture composed of Ar + 5%CO 2 + 2%iC 4 H 10 , providing good high voltage stability and a large pulse height, important for inclined track reconstruction of particles crossing the detector. To ensure the long-term stable operation of the detector during the whole HL-LHC period, and due to the hydrocarbon content in the mixture, an extensive aging campaign has been ongoing since 2021 at the CERN Gamma Irradiation Facility, where spare production chambers are long-term exposed to a 14 TBq 137 Cs 𝛾-source, accumulating so far, a charge equivalent to five years of HL-LHC operations under the highest expected background rate. This paper describes the results of the Micromegas chamber performance studies after two years of gamma irradiation and using the SPS/H4 120 GeV muon beams at CERN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of DUNE to long-baseline neutrino oscillation physics

DUNE is an international project, currently in its design phase, for neutrino physics and proton-decay searches. It will consist of two detectors exposed to a megawatt-scale muon neutrino beam that will be produced at Fermilab (Illinois, USA). One detector will record particle interactions near the source of the beam, while a second, much larger, detector comprising four 10-kilotonne liquid argon TPCs will be installed at a depth of 1.5~km at SURF (South Dakota, USA), about 1300 kilometres away of the neutrino source. Among the primary scientific goals of DUNE is the precision measurement of the parameters that govern neutrino mixing, including those still unknown: the octant in which the $\theta_{23}$ mixing angle lies, the neutrino mass ordering and the value of the CP violation phase. This paper discusses the sensitivity of the DUNE experiment to these parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanical stability of the CMS strip tracker measured with a laser alignment system

The CMS tracker consists of 206 m(2) of silicon strip sensors assembled on carbon fibre composite structures and is designed for operation in the temperature range from −25 to +25°C. The mechanical stability of tracker components during physics operation was monitored with a few μm resolution using a dedicated laser alignment system as well as particle tracks from cosmic rays and hadron-hadron collisions. During the LHC operational period of 2011–2013 at stable temperatures, the components of the tracker were observed to experience relative movements of less than 30μm. In addition, temperature variations were found to cause displacements of tracker structures of about 2μm°C, which largely revert to their initial positions when the temperature is restored to its original value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector and Electronic Developments for Low Energy Multi Particle Break-up Studies

The study of excited states of unbound light nuclei includes the simultaneous detection of several charge particles emitted with very low energy. This puts several constrains on the detection system to be used. For the detectors, high segmentation is needed to be able to detect several coincident particles without an exponential drop in efficiency. The high segmentation of the detectors leads to experiments with an increased amount of electronic channels. For very dedicated experiment integrated electronic chips can be prepared, but in many cases where the detector set-up are frequently being changed, one still have to rely on more traditional analogue electronic circuits. News in the field of charge particle detection will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

Measurements of sensor radiation damage in the ATLAS inner detector using leakage currents

Non-ionizing energy loss causes bulk damage to the silicon sensors of the ATLAS pixel and strip detectors. This damage has important implications for data-taking operations, charged-particle track reconstruction, detector simulations, and physics analysis. This paper presents simulations and measurements of the leakage current in the ATLAS pixel detector and semiconductor tracker as a function of location in the detector and time, using data collected in Run 1 (2010-2012) and Run 2 (2015-2018) of the Large Hadron Collider. The extracted fluence shows a much stronger |z|-dependence in the innermost layers than is seen in simulation. Furthermore, the overall fluence on the second innermost layer is significantly higher than in simulation, with better agreement in layers at higher radii. These measurements are important for validating the simulation models and can be used in part to justify safety factors for future detector designs and interventions.

47 OTHER INSTRUMENTATION↗

Fermilab: A plan for discovery

This Plan for Discovery describes Fermilab’s long-term scientific strategy. It evolved from the report of the Fermilab Steering Group, convened in 2007 to obtain input from a broad spectrum of U.S. particle and accelerator physics communities and to prepare a report that would provide input to Fermilab, the Particle Physics Project Prioritization Panel, the High Energy Physics Advisory Panel and the funding agencies as they considered options for new particle accelerators and detectors in the United States. A number of key events have occurred in particle physics over the last four years, including the successful startup of the Large Hadron Collider, the extension of the timeline for the International Linear Collider, and the end of Tevatron operations. These events have guided Fermilab in its implementation of the recommendations of the Steering Group and have led to the development of this Plan for Discovery. The plan is designed to maintain the nation’s leadership in particle physics and keep the laboratory and the United States on the path to discovery at the frontiers of particle physics.

99 GENERAL AND MISCELLANEOUS↗

SNM Detection with a Large Water Cerenkov Detector

Special Nuclear Material (SNM) can either spontaneously fission, or be induced to do so. Either case results in neutron emission. Since neutrons are highly penetrating and difficult to shield, they could, potentially, be detected escaping even a well shielded cargo container. Obviously, if the shielding is sophisticated, detecting it would require a highly efficient detector with close to 4{pi} solid angle coverage. Water Cerenkov detectors may be a cost effective way to achieve that goal if it can be shown that the neutron capture signature is large enough and if sufficient background rejection can be employed as detectors get larger. In 2008 the LLNL Advanced Detector Group reported the successful detection of neutrons with a 1/4 ton gadolinium doped water Cerenkov prototype. We have now built a 4 ton version. This detector is not only bigger, it was designed with photon detection efficiency in mind from the beginning. We are employing increased photocathode coverage and more reflective walls, coated with PTFE. The increased efficiency should allow better energy resolution. We expect that the better diffusive wall reflectivity will reduce the overall dependence of the detector response on particle direction, again producing a more consistent response. We also believe that as detectors get larger, both uncorrelated and correlated backgrounds due to gamma-rays and cosmic ray interactions near the detector will increase. To prove the effectiveness of the technology we must develop new ways to reject these backgrounds while maintaining our sensitivity to SNM neutrons. Better energy resolution will enable us to reject more of the low energy gamma-ray backgrounds on this basis. Overcoming cosmic ray induced neutrons is perhaps an even larger concern as detectors get larger. Our detector is designed so that we can test various segmentation schemes - effectively dividing the detector up into smaller ones. In this presentation, we will describe our detector in detail.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for axion-like particles through nuclear Primakoff production using the GlueX detector

We report on the results of the first search for the production of axion-like particles (ALPs) via Primakoff production on nuclear targets, γA → aA, in the “SRC-CT” experiment using the GlueX detector at Jefferson Lab. This search uses an integrated luminosity of 100 pb -1 nucleon on a 12 C target with a real photon beam of energies 6 < E γ < 10.8 GeV, and explores the mass region of 200 < m a < 450 MeV via the decay a → γγ. This mass range is between the π 0 and η meson masses, which enables the use of the measured η meson production rate to obtain absolute bounds on the ALP production with reduced sensitivity to experimental luminosity and detection efficiency. We find no evidence for an ALP, consistent with previous searches in the quoted mass range, and present limits on the effective photon coupling scale of $\mathscr{O}$(1 TeV -1 ). We further find that the ALP production limit we obtain is hindered by the peaking structure of the non-target-related dominant background the in GlueX spectrometer, which we treat by using data on 4 He to estimate and subtract it. We comment on how this search can be improved in a future higher-statistics dedicated measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

Charged-particle multiplicities in pp interactions measured with the ATLAS detector at the LHC

CERN-LHC. Measurement of inclusive charged particle distributions in proton proton collisions at centre-of-mass energies 0.9, 2.36 and 7 TeV using a single-arm minimum-bias trigger. Distributions of charged particle multiplicity and its dependence on pseudorapidity and transverse momentum are presented from ~190 mub-1 of data at 7 Tev, ~7 mub-1 at 0.9 TeV, and ~0.1 mub-1 at 2.36 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Directional Detector Response Function for Anisotropic Detectors

For a radiation detector that is not isotropic, a directional detector response is needed to accurately account for the variation in a detector’s behavior depending on the incoming particle direction. The concept of the detector response function has been extended to include particle direction using a set of pregenerated detector responses based on the orientation of the incoming radiation and the detector. This directional detector response function (DDRF) then can be applied to the flux and current tallies computed by a Monte Carlo simulation. Validation of the new approach has been done by comparing simulated count rates processed with the DDRF to measured count rates taken with a 5.08 × 10.16 × 40.64-cm NaI(Tl) detector. The comparisons show that the applied method produces good agreement with both background and source measurements with a 137 Cs source. Furthermore, separation of the detector response generation from Monte Carlo particle transport calculations provides greater flexibility in locating single or multiple detectors without any interference in the model and also enables simulation of various models using the same detector response without the need for generating additional detector responses if the same detector is being used.

42 ENGINEERING↗

Investigation of Coincidence Counting for Improving Minimal Detectable Activity of 110m Ag in Single Particle Gamma Analysis

Post-irradiation examination (PIE) of fuel particles from the fourth Advanced Gas Reactor Fuel Development and Qualification (AGR) Program irradiation (AGR-5/6/7) is being performed at Oak Ridge National Laboratory (ORNL). Tristructural isotropic (TRISO)-coated particles and associated compacts for the AGR-5/6/7 experiment fabricated by BWX Technologies Nuclear Operations Group were formed into a graphite matrix compact and irradiated at the Advanced Test Reactor at Idaho National Laboratory. At ORNL, particles are deconsolidated from the graphite matrix compact and individually scanned for emitted gamma rays with the Irradiated Microsphere Gamma Analyzer (IMGA). The IMGA system comprises a single high purity germanium (HPGe) detector, an automated particle handling vacuum system, and an ORTEC DSPEC-50 digital spectrometer for gamma ray analysis. IMGA quantifies gamma ray-emitting fission product inventories of individual TRISO particles, and these inventories can be compared with the measured average inventories per particle and radionuclide inventories predicted by AGR-5/6/7 physics calculations to determine if a particle experienced radionuclide release. Details on IMGA data collection methods can be found in the literature. The TRISO particle’s SiC layer provides structural support, as well as a barrier for fission product release during irradiation or subsequent safety testing. A weakened or compromised SiC layer can be identified by the release of radionuclides, such as 137 Cs, which is detected by IMGA. However, select radionuclides, such as 90 Sr, 110 mAg, and 154 Eu have been shown to migrate through an intact SiC layer. Measurement of the radionuclide 110 mAg is significant as its release has been shown to be particularly sensitive to in-reactor conditions (e.g., temperature) with broad variable particle to-particle release behaviors observed within a single compact. As such, 110 mAg activity is often used for particle selection for comprehensive PIE as bounding 110 mAg retention particles are hypothesized to represent limits in particle behaviors within a compact. As TRISO particle fuel PIE activities continue over time, IMGA measurements of the 110 mAg inventory are eventually hindered because of its relatively short half-life (~250 days). As the fuel ages from its end of irradiation (EOI) date, the measurement uncertainty and minimum detectable activity (MDA) of 110m Ag increase because the detector background continuum begins to dominate. For particles from the second AGR irradiation experiment (AGR-2), the 110m Ag MDA was above 20% of the calculated average particle inventory after approximately five half-lives, and 110m Ag activity was no longer measurable with IMGA after approximately seven half-lives. Therefore, coincidence counting approaches have been explored to determine feasibility of leveraging new approaches to overcome limitations associated with increasing MDA over time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of ionizing radiation on cryogenic infrared detectors

The Diffuse Infrared Background Experiment (DIRBE) is one of three experiments to be carried aboard the Cosmic Background Explorer (COBE) satellite scheduled to be launched by NASA on a Delta rocket in 1989. The DIRBE is a cryogenic absolute photometer operating in a liquid helium dewar at 1.5 K. Photometric stability is a principal requirement for achieving the scientific objectives of this experiment. The Infrared Astronomy Satellite (IRAS), launched in 1983, which used detectors similar to those in DIRBE, revealed substantial changes in detector responsivity following exposure to ionizing radiation encountered on passage through the South Atlantic Anomaly (SAA). Since the COBE will use the same 900 Km sun-synchronous orbit as IRAS, ionizing radiation-induced performance changes in the detectors were a major concern. Here, ionizing radiation tests carried out on all the DIRBE photodetectors are reported. Responsivity changes following exposure to gamma rays, protons, and alpha particle are discussed. The detector performance was monitored following a simulated entire mission life dose. In addition, the response of the detectors to individual particle interactions was measured. The InSb photovoltaic detectors and the Blocked Impurity Band (BIB) detectors revealed no significant change in responsivity following radiation exposure. The Ge:Ga detectors show large effects which were greatly reduced by proper thermal annealing.

Moseley, S. H.↗