Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Gastrostomy Tube Placement Without Nasogastric Tube: A Retrospective Evaluation in 85 Patients

Purpose: Our study evaluated techniques for percutaneous gastrostomy (G)-tube placement without the use of a nasogastric (NG) tube. Instead, direct puncture of a physiologic air bubble or effervescent-enhanced gastric bubble distention was performed in patients with upper digestive tract obstruction (UDTO) or psychological objections to NG tubes. Materials and Methods: A total of 886 patients underwent G-tube placement in our department during a period of 7 years. We present our series of 85 (9.6%) consecutive patients who underwent percutaneous G-tube placement without use of an NG tube. Results: Of these 85 patients, fluoroscopic guided access was attempted by direct puncture of a physiologically present gastric air bubble in 24 (28%) cases. Puncture of an effervescent-induced large gastric air bubble was performed in 61 (72%) patients. Altogether, 82 (97%) of 85 G tubes were successfully placed in this fashion. The three failures comprised refusal of effervescent, vomiting of effervescent, and one initial tube misplacement when a deviation from our standard technique occurred. Conclusion: The described techniques compare favorably with published large series on G-tube placement with an NG tube in place. The techniques are especially suited for patients with UDTO due to head, neck, or esophageal malignancies, but they should be considered as an alternative in all patients. Direct puncture of effervescent-enhanced gastric bubble distention is a safe, patient-friendly and effective technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation and generalized Langevin equation study of lipid subdiffusion in biomembrane phases

In biomembranes lipid mobility exhibits deviations from the classical diffusive behavior of Brownian particles, i.e. ‘anomalous’ diffusion. The question arises as to how this anomalous diffusive behavior varies in gel, ripple, and fluid biomembrane phases. Here, in this study, we perform all-atom molecular dynamics (MD) simulations of dimyristoylphosphatidylcholine (DMPC) bilayers in the three different phases and analyze the results using the framework of the Generalized Langevin Equation (GLE). This analysis emphasizes sub-diffusive behavior on the relatively short, picosecond-nanosecond timescales, capturing local molecular constraints and transient caging effects during the crossover of atomic dynamics from vibrational to incipient anharmonic motion. The ripple and gel phases are found to exhibit strong transient caging and prolonged memory effects resulting in distinct sub-diffusive behavior. The role of hydrogen bonding in lipid confinement is also examined, demonstrating its influence on phase-dependent molecular ordering and on short-time diffusional constraints. These findings demonstrate the GLE framework’s utility in characterizing molecular transport and lipid dynamics, with implications for longer timescale membrane dynamics.

Malik, Sheeba [Oak Ridge National Laboratory (ORNL↗

Prospective Clinical Implementation of a Novel Magnetic Resonance Tracking Device for Real-Time Brachytherapy Catheter Positioning

Purpose: We designed and built dedicated active magnetic resonance (MR)-tracked (MRTR) stylets. We explored the role of MRTR in a prospective clinical trial. Methods and Materials: Eleven gynecologic cancer patients underwent MRTR to rapidly optimize interstitial catheter placement. MRTR catheter tip location and orientation were computed and overlaid on images displayed on in-room monitors at rates of 6 to 16 frames per second. Three modes of actively tracked navigation were analyzed: coarse navigation to the approximate region around the tumor; fine-tuning, bringing the stylets to the desired location; and pullback, with MRTR stylets rapidly withdrawn from within the catheters, providing catheter trajectories for radiation treatment planning (RTP). Catheters with conventional stylets were inserted, forming baseline locations. MRTR stylets were substituted, and catheter navigation was performed by a clinician working inside the MRI bore, using monitor feedback. Results: Coarse navigation allowed repositioning of the MRTR catheters tips by 16 mm (mean), relative to baseline, in 14 ± 5 s/catheter (mean ± standard deviation [SD]). The fine-tuning mode repositioned the catheter tips by a further 12 mm, in 24 ± 17 s/catheter. Pullback mode provided catheter trajectories with RTP point resolution of ∼1.5 mm, in 1 to 9 s/catheter. Conclusions: MRTR-based navigation resulted in rapid and optimal placement of interstitial brachytherapy catheters. Catheters were repositioned compared with the initial insertion without tracking. In pullback mode, catheter trajectories matched computed tomographic precision, enabling their use for RTP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfraction rotation of the prostate as evaluated by kilovoltage X-ray fiducial marker imaging in intensity-modulated radiotherapy of localized prostate cancer

To quantify the daily rotation of the prostate during a radiotherapy course using stereoscopic kilovoltage (kV) x-ray imaging and intraprostatic fiducials for localization and positioning correction. From 2005 to 2009, radio-opaque fiducial markers were inserted into 38 patients via perineum into the prostate. The ExacTrac/Novalis Body X-ray 6-day image acquisition system (ET/NB; BrainLab AG, Feldkirchen, Germany) was used to determine and correct the target position. During the first period in 10 patients we recorded all rotation errors but used only Y (table) for correction. For the next 28 patients we used for correction all rotational coordinates, i.e., in addition Z (superior-inferior [SI] or roll) and X (left-right [LR] or tilt/pitch) according to the fiducial marker position by use of the Robotic Tilt Module and Varian Exact Couch. Rotation correction was applied above a threshold of 1 Degree-Sign displacement. The systematic and random errors were specified. Overall, 993 software-assisted rotational corrections were performed. The interfraction rotation errors of the prostate as assessed from the radiodense surrogate markers around the three axes Y, Z, and X were on average 0.09, -0.52, and -0.01 Degree-Sign with standard deviations of 2.01, 2.30, and 3.95 Degree-Sign , respectively. The systematic uncertainty per patient for prostate rotation was estimated with 2.30, 1.56, and 4.13 Degree-Sign and the mean random components with 1.81, 2.02, and 3.09 Degree-Sign . The largest rotational errors occurred around the X-axis (pitch), but without preferring a certain orientation. Although the error around Z (roll) can be compensated on average by a transformation with 4 coordinates, a significant error around X remains and advocates the full correction with 6 coordinates. Rotational errors as assessed via daily stereoscopic online imaging are significant and dominate around X. Rotation possibly degrades the dosimetric coverage of the target volume and may require suitable strategies for correction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Single-photon test of hyper-complex quantum theories using a metamaterial

In standard quantum mechanics, complex numbers are used to describe the wavefunction. Although this has so far proven sufficient to predict experimental results, there is no theoretical reason to choose them over real numbers or generalizations of complex numbers, that is, hyper-complex numbers. Experiments performed to date have proven that real numbers are insufficient, but the need for hyper-complex numbers remains an open question. Here we experimentally probe hyper-complex quantum theories, studying one of their deviations from complex quantum theory: the non-commutativity of phases. We do so by passing single photons through a Sagnac interferometer containing both a metamaterial with a negative refractive index, and a positive phase shifter. In order to accomplish this we engineered a fishnet metamaterial to have a negative refractive index at 780 nm. Here, we show that the metamaterial phase commutes with other phases with high precision, allowing us to place limits on a particular prediction of hyper-complex quantum theories.

36 MATERIALS SCIENCE↗

Effect of annealing treatment on K{beta}-to-K{alpha} x-ray intensity ratios of 3d transition-metal alloys

The influence of heat annealing treatment on the K{beta}-to-K{alpha} x-ray intensity ratios of 3d transition metal was carried out by x-ray fluorescence studies of various alloy compositions. K{beta}-to-K{alpha} x-ray intensity ratios of Fe, Ni, Ti, Co, and Cu in Fe{sub x}Ni{sub 1-x}, Ti{sub x}Ni{sub 1-x}, and Co{sub x}Cu{sub 1-x} alloys unannealed and thermally annealed at different temperatures have been measured following excitation by 22.69-keV x rays from a 10-mCi {sup 109}Cd radioactive point source. The experimental data obtained after annealing treatment indicate deviations of K{beta}-to-K{alpha} x-ray intensity ratios for 3d transition metals in different alloy compositions from the corresponding ratios for unannealed samples. The present investigation makes it possible to perform reliable interpretation of experimental K{beta}-to-K{alpha} x-ray intensity ratios for various 3d transition metals in their alloys and can also provide quantitative information about the changes of the K{beta}-to-K{alpha} x-ray intensity ratios of these metals with annealing treatment in considered systems.

36 MATERIALS SCIENCE↗

Data-Driven Residential Load Modeling and Validation in GridLAB-D

Accurately characterizing the impacts of high penetrations of distributed energy resources (DER) on the electric distribution system has driven modeling methods from traditional static snap shots, often representing a critical point in time (e.g., summer peak load), to quasi-static time series (QSTS) simulations capturing all the effects of variable DER, associated controls and hence, impacts on the distribution system over a given time period. Unfortunately, the high time resolution DER source and load data required for model inputs is often scarce or non-existent. This paper presents work performed within the GridLAB-D model environment to synthesize, calibrate, and validate 1-second residential load models based on measured transformer loads and physics-based models suitable for QSTS electric distribution system modeling. The modeling and validation approach taken was to create a typical GridLAB-D model home that, when replicated to represent multiple diverse houses on a single transformer, creates a statistically similar load to a measured load for a given weather input. The model homes are constructed to represent the range of actual homes on an instrumented transformer: square footage, thermal integrity, heating and cooling system definition as well as realistic occupancy schedules. House model calibration and validation was performed using the distribution transformer load data and corresponding weather. The modeled loads were found to be similar to the measured loads for four evaluation metrics: 1) daily average energy, 2) daily average and standard deviation of power, 3) power spectral density, and 4) load shape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Restoration of Grid-Forming Inverters in Pulse Load and Plug-in Events

This article presents a restoration technique using grid-forming inverters in an islanded microgrid during pulse load and plug-in events. In a microgrid powered by droop-controlled inverters, frequency is the variable that is accessible to all inverters for adjusting their power contributions. The problem is that the microgrid frequency deviates from its nominal value after a load change. The presented method enables the inverters to restore the frequency to the nominal value and regulate their bus voltage amplitudes. The frequency and voltage restorations are performed without communication while achieving the desired power-sharing between grid-forming inverters. The restoration is activated after detecting any active or reactive power changes. In this article, the dynamic model of an inverter equipped with enabled restoration paths is developed to verify the stability of the inverter controller under various conditions. The frequency and voltage restorations are examined during pulse load and plug-in events. Furthermore, this study is performed using a laboratory-scale islanded microgrid powered by two 208 V, 60 Hz, 5 kVA inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware-in-the-Loop Evaluation for Potential High Limit Estimation-Based PV Plant Active Control

This paper validates the efficacy of an artificial intelligence (AI)-based photovoltaic (PV) plant control and optimization approach in enabling PV plants as accountable grid reliability service providers. The validation is performed in a realistic laboratory controller-hardware-in-the-loop environment, leveraging accurate PV plant modeling and standard industrial communication protocols. Through simulations that account for diverse weather conditions and active control scenarios, the results highlight the superior performance of the AI-based solution in comparison to a state-of-the-art reference-control grouping-based approach. Such a finding contributes to mitigating the risk of overcurtailment and uninstructed deviations of active PV plant controls, and offers practical guidance for its field deployment. Furthermore, it establishes a standardized testing framework for comparing various PV active control strategies.

hardware-in-the-loop↗

A Hierarchical VLSM-Based Demand Response Strategy for Coordinative Voltage Control between Transmission and Distribution Systems

This paper presents a two-stage hierarchical voltage-load sensitivity matrix (VLSM)-based demand response (DR) algorithm for regulating the voltage at distribution feeders while fulfilling the transmission system DR requests. This allows distributed energy resources be aggregated to provide transmission-level services without causing operational issues in the distribution grids. At the beginning of each operation interval, a transmission system controller will issue DR commands to distribution system controllers. In the first stage, the distribution system controller uses a VLSM-based dispatch algorithm to dispatch the available DR resources on the distribution feeder with an objective to minimize the total voltage deviations at the lowest cost. Then, power flow studies are conducted assuming that the DR commands have been executed. If voltage violations are detected, a second-stage VLSM-based DR dispatch will be performed to remove those violations. After that, the upper and lower DR limits calculated for the next operation interval are sent back to the transmission system controller so the transmission optimization algorithm can use them as operational constraints to make subsequent decisions. The DR resources include smart photovoltaic (PV) inverters that can curtail real power and provide reactive power support, controllable loads and capacitor banks. In conclusion, the IEEE 123-bus test system with 5-minute PV and load data is used to evaluate the performance of the algorithm. In conclusion, simulation results show that the proposed algorithm can fulfill the transmission-level DR requests while maintaining the voltage in the distribution system within limits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quality assurance of proton beams using a multilayer ionization chamber system

Purpose: The measurement of percentage depth-dose (PDD) distributions for the quality assurance of clinical proton beams is most commonly performed with a computerized water tank dosimetry system with ionization chamber, commonly referred to as water tank. Although the accuracy and reproducibility of this method is well established, it can be time-consuming if a large number of measurements are required. In this work the authors evaluate the linearity, reproducibility, sensitivity to field size, accuracy, and time-savings of another system: the Zebra, a multilayer ionization chamber system.Methods: The Zebra, consisting of 180 parallel-plate ionization chambers with 2 mm resolution, was used to measure depth-dose distributions. The measurements were performed for scattered and scanned proton pencil beams of multiple energies delivered by the Hitachi PROBEAT synchrotron-based delivery system. For scattered beams, the Zebra-measured depth-dose distributions were compared with those measured with the water tank. The principal descriptors extracted for comparisons were: range, the depth of the distal 90% dose; spread-out Bragg peak (SOBP) length, the region between the proximal 95% and distal 90% dose; and distal-dose fall off (DDF), the region between the distal 80% and 20% dose. For scanned beams, the Zebra-measured ranges were compared with those acquired using a Bragg peak chamber during commissioning.Results: The Zebra demonstrated better than 1% reproducibility and monitor unit linearity. The response of the Zebra was found to be sensitive to radiation field sizes greater than 12.5 × 12.5 cm; hence, the measurements used to determine accuracy were performed using a field size of 10 × 10 cm. For the scattered proton beams, PDD distributions showed 1.5% agreement within the SOBP, and 3.8% outside. Range values agreed within −0.1 ± 0.4 mm, with a maximum deviation of 1.2 mm. SOBP length values agreed within 0 ± 2 mm, with a maximum deviation of 6 mm. DDF values agreed within 0.3 ± 0.1 mm, with a maximum deviation of 0.6 mm. For the scanned proton pencil beams, Zebra and Bragg peak chamber range values demonstrated agreement of 0.0 ± 0.3 mm with a maximum deviation of 1.3 mm. The setup and measurement time for all Zebra measurements was 3 and 20 times less, respectively, compared to the water tank measurements.Conclusions: Our investigation shows that the Zebra can be useful not only for fast but also for accurate measurements of the depth-dose distributions of both scattered and scanned proton beams. The analysis of a large set of measurements shows that the commonly assessed beam quality parameters obtained with the Zebra are within the acceptable variations specified by the manufacturer for our delivery system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicting Coculture Substrate Depletion (PCSD) v1

(based on Erbilgin et al., BMC Bioinformatics, 2017, 18:57). Mixed cultures of microbial species are increasingly used to carry out a specific task in lieu of engineering a single microbe to do the same task. However, knowing how different species' metabolisms will integrate to reach a desired outcome is a difficult problem that has been studied in great detail--but only using steady-state models. Mixed cultures used for biotechnology processes, as well as microbial communities that exist in nature and crop agriculture, are metabolically dynamic systems. Studying the temporal substrate utilization by individuals is individuals in mixed cultures is an important first step in developing approaches to better model these biochemical processes and microbial communities found in nature. The 2017-004 software is comprised of four custom iPython notebooks that were used for all computational tasks in the experimental work described in "Dynamic substrate preferences predict metabolic properties of a simple microbial consortium" (Erbilgin et al., BMC Bioinformatics, 2017). The results indicate that a significant portion of a model community's overall metabolism can be predicted based on the metabolism of the individuals. The results further suggest that, when the mixed culture's substrate depletion significantly deviates from such a prediction, this may highlight potential metabolic pathways affected by species-species microbial interactions, leading to hypotheses about how a particular microbial community's structure and function may be modulated to perform a particular biotechnological goal.

Bowen, Benjamin↗

Determination of liquid-phase immiscibility in the lead-zinc system

A number of different techniques in the past have yielded inconsistent equilibrium measurements of immiscibility in the Pb-Zn system above 600 C. Accurate differential thermal analysis (DTA) measurements were performed on well-homogenized samples of high-purity Pb-Zn, and they indicate that the immiscibility curve is higher than previously accepted for Zn compositions between 20 and 70 at. %. The maximum deviations observed correspond to about 20 C. Below 600 C the DTA results agree with previous results.

Trahan, J. F.↗

Determination of effective aerodynamic characteristics for entry of External Tank /Space Shuttle/ debris

The effective aerodynamic characteristics for the debris resulting from the Space Shuttle External Tank (ET) are required for estimating the impact points of the debris. The paper develops a methodology that determines the effective values of the aerodynamic parameters required for performing the less complex three-degree-of-freedom (DOF) debris impact analyses. For all of the debris types, 6-DOF mass property and aerodynamic data are computed. From many 6-DOF trajectory simulations, standard deviation range values are calculated. With 3-DOF trajectory matching, these range values are used to determine the effective ballistic coefficient and the range of lift-to-drag ratios for each of the ET debris types defined.

Bonson, S. P.↗

Fatigue and associated performance decrements in air transport operations

A study of safety reports was conducted to examine the hypothesis that fatigue and associated performance decrements occur in air transport operations, and that these are associated with some combination of factors: circadian desynchronosis, duty time; pre-duty activity; sleep; work scheduling; workload; and environmental deprivation. The findings are based on a selected sample of reported incidents in which the reporter associated fatigue with the occurrence. In comparing the fatigue reports with a control set, significant performance decrements were found to exist related to time-of-day, awareness and attention to duty, less significantly, final phases of flights. The majority of the fatigue incidents involved such unsafe events as altitude deviations, takeoffs and landing without clearance, and the like. Considerations of duty and sleep are the major factors in the reported fatigue conditions.

Lyman, E. G.↗

Topographic mapping using radar interferometry - Processing techniques

In the summer of 1991 the NASA DC-8 airborne synthetic aperture radar (SAR) system acquired data with the radar configured in a C-band across-track interferometer mode. The data were processed to generate rectified topographic maps. A new processing scheme was developed featuring motion compensation, absolute phase retrieval, and three-dimensional 1ocation. The new processor has been tested using data which were acquired with extreme aircraft motion so that performance could be evaluated under adverse conditions. The topographic maps generated by the radar were compared to Digital Elevation Models (DEM's) derived using conventional optical stereo techniques. In one region we measured rms elevation deviations which were less than the specified DEM accuracy, and in the region covered by the more accurate DEM we found errors varying from 2.2 m rms in relatively flat terrain up to 5.0 m in mountainous areas. The rms difference between radar and DEM elevations over the 6.5 km by 22 km area covered by the more accurate DEM was 3.6 m.

Madsen, Soren N.↗

Aerodynamic Design of Axial-flow Compressors. VI - Experimental Flow in Two-Dimensional Cascades

Available experimental two-dimensional cascade data for conventional compressor blade sections are correlated at a reference incidence angle in the region of minimum loss. Variations of reference incidence angle, total-pressure loss, and deviation angle with cascade geometry, inlet Mach number, and Reynolds number are investigated. From the analysis and the correlations of the available data, rules and relations are evolved for the prediction of blade-profile performance. These relations are developed in simplified forms readily applicable to compressor design procedures.

Lieblein, Seymour↗

Software for Automation of Real-Time Agents, Version 2

Version 2 of Closed Loop Execution and Recovery (CLEaR) has been developed. CLEaR is an artificial intelligence computer program for use in planning and execution of actions of autonomous agents, including, for example, Deep Space Network (DSN) antenna ground stations, robotic exploratory ground vehicles (rovers), robotic aircraft (UAVs), and robotic spacecraft. CLEaR automates the generation and execution of command sequences, monitoring the sequence execution, and modifying the command sequence in response to execution deviations and failures as well as new goals for the agent to achieve. The development of CLEaR has focused on the unification of planning and execution to increase the ability of the autonomous agent to perform under tight resource and time constraints coupled with uncertainty in how much of resources and time will be required to perform a task. This unification is realized by extending the traditional three-tier robotic control architecture by increasing the interaction between the software components that perform deliberation and reactive functions. The increase in interaction reduces the need to replan, enables earlier detection of the need to replan, and enables replanning to occur before an agent enters a state of failure.

Fisher, Forest↗