Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Far-infrared observations of M17SW - The clumpy structure of the photodissociation region

Forbidden O I 63-micron and forbidden Si II 35-micron fine-structure line emission in M17SW was mapped, and the intensities of the forbidden O I 63 and 146 microns, forbidden Si II 35 microns, and forbidden C II 158 microns were measured at four positions. New 50- and 100-micron continuum maps of the M17SW cloud at comparable resolution to the FIR line observations are presented. Analysis in terms of a homogeneous model yields an incident UV field of 56,000 habings, a density of 30,000 cu cm, and a temperature of about 300 K for the atomic gas. It is concluded that the M17SW photodissociation region is clumpy in nature. The observed forbidden Si II and high-J CO imply the presence of high-density clumps. The clumps dominate the emission in the forbidden O I, Si II, and high-level CO lines, while the forbidden C II, C I, and low-level CO arise mostly in the interclump gas. The extended (about 15 pc) forbidden C II and forbidden C I emission is attributed to the halo gas.

Meixner, Margaret↗

Observations of the solar corona with a high resolution EUV imaging spectrograph

An extreme ultraviolet imaging spectrograph was used to obtain coronal observations with high spectral and spatial resolution. The imaging properties of the instrument enable measurements of spectral line shapes and positions in discrete spatial elements of a region, so that the dynamic characteristics of the coronal plasma, as well as the distribution of emission measure with temperature and well known density diagnostics, can be studied for specific features. The instrumentation is described and several results of a sounding rocket flight on 5 May 1989, when the corona over NOAA Region 5464 including emission over the umbra of the region's largest sunspot and the pre-impulsive phase emission of a small flare was recorded, are summarized.

Neupert, Werner M.↗

Geostatistical approaches to interpolation and classification of remote-sensing data from ice surfaces

Geostatistical methods for interpolation and extrapolation techniques are used in glaciological data analysis. The results of a program involving the mapping of the Antarctica from satellite radar altimeter data are discussed. A combination of high and low resolution techniques was applied in the analysis of the Bering Glacier (Alaska). The global positioning system (GPS) located video data collected from small aircraft and the ERS-1 synthetic aperture radar (SAR) images were used. From the perspective of SAR data analysis, the Bering Glacier surge was the opportunity to characterize the surface of fast flowing ice and the rapid changes in the surface roughness.

Herzfeld, Ute Christina↗

Detection of [O I] 63 Micron Emission from the Galactic Center

The detection of the 63 microns line of [O I] is reported for three positions in the H II region complex Sgr A at the galactic center. Velocity resolution of the line indicates that the emitting material has both rotational and radial motion of magnitude similar to that of the ionized gas in the core and that a substantial amount of the emitting material lies within the central few parsecs of the Galaxy. A model in which [O I] is collisionally excited by neutral hydrogen, either from the warm region ahead of an ionization front or behind a shock, is proposed and gives a total mass of hot, neutral gas within the central 3 pc of the Galaxy of between 10 and 10(exp 3) solar mass. A limit on the flux of this line has been set for Sgr B2.

Lester, D. F.↗

Measuring Greenland Ice Mass Variation With Gravity Recovery and the Climate Experiment Gravity and GPS

The response of the Greenland ice sheet to climate change could significantly alter sea level. The ice sheet was much thicker at the last glacial maximum. To gain insight into the global change process and the future trend, it is important to evaluate the ice mass variation as a function of time and space. The Gravity Recovery and Climate Experiment (GRACE) mission to fly in 2001 for 5 years will measure gravity changes associated with the current ice variation and the solid earth's response to past variations. Our objective is to assess the separability of different change sources, accuracy and resolution in the mass variation determination by the new gravity data and possible Global Positioning System (GPS) bedrock uplift measurements. We use a reference parameter state that follows a dynamic ice model for current mass variation and a variant of the Tushingham and Peltier ICE-3G deglaciation model for historical deglaciation. The current linear trend is also assumed to have started 5 kyr ago. The Earth model is fixed as preliminary reference Earth model (PREM) with four viscoelastic layers. A discrete Bayesian inverse algorithm is developed employing an isotropic Gaussian a priori covariance function over the ice sheet and time. We use data noise predicted by the University of Texas and JPL for major GRACE error sources. A 2 mm/yr uplift uncertainty is assumed for GPS occupation time of 5 years. We then carry out covariance analysis and inverse simulation using GRACE geoid coefficients up to degree 180 in conjunction with a number of GPS uplift rates. Present-day ice mass variation and historical deglaciation are solved simultaneously over 146 grids of roughly 110 km x 110 km and with 6 time increments of 3 kyr each, along with a common starting epoch of the current trend. For present-day ice thickness change, the covariance analysis using GRACE geoid data alone results in a root mean square (RMS) posterior root variance of 2.6 cm/yr, with fairly large a priori uncertainties in the parameters and a Gaussian correlation length of 350 km. Simulated inverse can successfully recover most features in the reference present-day change. The RMS difference between them over the grids is 2.8 cm/yr. The RMS difference becomes 1.1 cm/yr when both are averaged with a half Gaussian wavelength of 150 km. With a fixed Earth model, GRACE alone can separate the geoid signals due to past and current load fairly well. Shown are the reference geoid signatures of direct and elastic effects of the current trend, the viscoelastic effect of the same trend starting from 5 kyr ago, the Post Glacial Rebound (PGR), and the predicted GRACE geoid error. The difference between the reference and inverse modeled total viscoelastic signatures is also shown. Although past and current ice mass variations are allowed the same spatial scale, their geoid signals have different spatial patterns. GPS data can contribute to the ice mass determination as well. Additional information is contained in the original.

Wu, Xiao-Ping↗

Validation of ADAR System 5500 Digital Imagery: Delivery Task Order #1, Task Request #857 - Brookings, SD

This work was performed under NASA's Verification and Validation Program as an independent check of data supplied by Positive Systems, Inc. through the Earth Science Enterprise's Scientific Data Purchase (SDP) Program. This document serves as the basis for reporting results associated with validation of multispectral imagery according to the specifications of contract NAS 13-98049. The validation was performed under the Positive Systems Imaging System Validation Work Instruction CRSP-WI-28: Spectral registration, spatial resolution, endlaps, sidelaps, and image quality were evaluated. The validation was proceded by Shipment Verification, as described in the Work Instruction CRSP-WI-22: Every image was passed through an automatic ingest verification and thumbnail review process to identify omissions, problems with media integrity, and gross errors in data quality. Validation of metadata files is not within the scope of this report, but it was performed separately.

Blonski, Slawomir↗

Identifying Optimal Temporal Scale for the Correlation of AOD and Ground Measurements of PM2.5 to Improve the Modeling Performance in a Real-Time Air Quality Estimation System

Aerosol optical depth (AOD), derived from satellite measurements using Moderate Resolution Imaging Spectrometer (MODIS), offers indirect estimates of particle matter. Research shows a significant positive correlation between satellite-based measurements of AOD and ground-based measurements of particulate matter with aerodynamic diameter less than or equal to 2.5 micrometers (PM2.5). In addition, satellite observations have also shown great promise in improving estimates of PM2.5 air quality surface. Research shows that correlations between AOD and ground PM2.5 are affected by a combination of many factors such as inherent characteristics of satellite observations, terrain, cloud cover, height of the mixing layer, and weather conditions, and thus might vary widely in different regions, different seasons, and even different days in a same location. Analysis of correlating AOD with ground measured PM2.5 on a day-to-day basis suggests the temporal scale, a number of immediate latest days for a given run's day, for their correlations needs to be considered to improve air quality surface estimates, especially when satellite observations are used in a real-time pollution system. The second reason is that correlation coefficients between AOD and ground PM2.5 cannot be predetermined and needs to be calculated for each day's run for a real-time system because the coefficients can vary over space and time. Few studies have been conducted to explore the optimal way to apply AOD data to improve model accuracies of PM2.5 surface estimation in a real-time air quality system. This paper discusses the best temporal scale to calculate the correlation of AOD and ground particle matter data to improve the results of pollution models in real-time system.

Li,Hui↗

Heavy Ozone Enrichment from ATMOS Infrared Solar Spectra

Vertical enrichment profiles of stratospheric ozone with oxygen 18 in the second or third position have been derived from space- based solar occultation spectra recorded at 0.01/cm resolution with the ATMOS (Atmospheric Trace Molecule Spectroscopy) Fourier- transform infrared (FTIR) spectrometer.

ozone↗

Systems and methods for vehicle cruise speed recommendation

A method for providing a cruising speed recommendation to an operator of a vehicle includes determining a projected route; receiving route characteristic data including route elevation data; determining a sampling resolution; sampling the route elevation data at the sampling resolution to generate sampled route elevation data; determining at least one start of uphill position and at least one start of downhill position; determining at least one cruise speed route segment based at least in part on the at least one start of uphill position and the at least one start of downhill position; determining a corresponding cruising speed for the at least one cruise speed route segment based at least in part on one or more of the route elevation data and the sampled route elevation data; and communicating the corresponding cruising speed for the at least one cruise speed route segment.

Aggoune, Karim↗

High-throughput Accurate-wavelength Lens-based Visible Spectrometera

A scanning visible spectrometer has been prototyped to complement fixed-wavelength transmission grating spectrometers for charge exchange recombination spectroscopy. Fast f/1.8 200 mm commercial lenses are used with a large 2160 mm-1 grating for high throughput. A stepping-motor controlled sine drive positions the grating, which is mounted on a precision rotary table. A high-resolution optical encoder on the grating stage allows the grating angle to be measured with an absolute accuracy of 0.075 arcsec, corresponding to a wavelength error ≤ 0.005 Å. At this precision, changes in grating groove density due to thermal expansion and variations in the refractive index of air are important. An automated calibration procedure determines all relevant spectrometer parameters to high accuracy. Changes in bulk grating temperature, atmospheric temperature and pressure are monitored between the time of calibration and the time of measurement to insure a persistent wavelength calibration

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lu1-xI3:Cex--A Scintillator for gamma ray spectroscopy and time-of-flight PET

The present invention concerns very fast scintillator materials comprising lutetium iodide doped with Cerium Lu.sub.1-xI.sub.3:Ce.sub.x; LuI.sub.3:Ce). The LuI.sub.3 scintillator material has surprisingly good characteristics including high light output, high gamma ray stopping efficiency, fast response, low cost, good proportionality, and minimal afterglow that the material is useful for gamma ray spectroscopy, medical imaging, nuclear and high energy physics research, diffraction, non-destructive testing, nuclear treaty verification and safeguards, and geological exploration. The timing resolution of the scintillators of the present invention provide compositions capable of resolving the position of an annihilation event within a portion of a human body cross-section.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Companding technique for high dynamic range measurements using Gafchromic films

Purpose: To introduce a methodology to perform dose measurements using Gafchromic films which can span several decades of dose levels. Methods: The technique is based on a rescaling approach using different films irradiated at different dose levels. This is combined with a registration protocol correcting positioning and scaling factors for each film. The methodology is validated using TLD's for out-of-field doses. Furthermore, two examples are provided using the technique to characterize small sized radiosurgery cones and compared with measurements made with a pinpoint chamber. Results: Excellent agreement with TLD, planning systems and measurement was found. The superior resolution of the film technique was apparent. Conclusions: The authors have introduced a new technique allowing users to quantify very low doses in conjunction with commissioning measurements. The use of film also provides 2D information on beam characteristics in high resolution measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photo-Scanning Electrochemical Microscopy on the Nanoscale with Through-Tip Illumination

Scanning electrochemical microscopy (SECM) has previously been employed in probing photoelectrochemical processes at semiconductor surfaces. Yet, the spatial resolution of these studies has not yet matched the nanoscale SECM resolution attained without substrate illumination. Herein, we introduce nanoscale photo-SECM with a glass-sealed, polished tip simultaneously serving as a nanoelectrode and a light guide to produce a microscopic light spot on the substrate surface. The advantages of this approach are demonstrated by comparing current transients obtained using through-tip and global illumination of the sample. The spot of light on the substrate surface facing the nanotip was sufficiently bright to measure the diffusion-controlled positive feedback current in good agreement with the theory. Here, we employed this approach for high-resolution photoelectrochemical mapping of ferrocenemethanol oxidation and oxygen evolution reactions at the Nb:TiO 2 rutile (110) single crystal surface. The images obtained using 40-50 nm radius tips showed only minor and random variations in photoelectrochemical reactivity for both processes, pointing to essentially uniform distribution of the Nb dopant over the TiO 2 surface and no measurable segregation on the ~50 nm scale.

14 SOLAR ENERGY↗

High Angular Resolution Gravitational Wave Astronomy

Since the very beginning of astronomy the location of objects on the sky has been a fundamental observational quantity that has been taken for granted. While precise two dimensional positional information is easy to obtain for observations in the electromagnetic spectrum, the positional accuracy of current and near future gravitational wave detectors is limited to between tens and hundreds of square degrees, which makes it extremely challenging to identify the host galaxies of gravitational wave events or to detect any electromagnetic counterparts. Gravitational wave observations provide information on source properties that is complementary to the information in any associated electromagnetic emission. Observing systems with multiple messengers thus has scientific potential much greater than the sum of its parts. A gravitational wave detector with higher angular resolution would significantly increase the prospects for finding the hosts of gravitational wave sources and triggering a multi-messenger follow-up campaign. An observatory with arcminute precision or better could be realised within the Voyage 2050 programme by creating a large baseline interferometer array in space and would have transformative scientific potential. Precise positional information of standard sirens would enable precision measurements of cosmological parameters and offer new insights on structure formation; a high angular resolution gravitational wave observatory would allow the detection of a stochastic background and resolution of the anisotropies within it; it would also allow the study of accretion processes around black holes; and it would have tremendous potential for tests of modified gravity and the discovery of physics beyond the Standard Model.

Gravitational waves↗

AI-3000K Infrared Line List for Hot CO 2

AI-3000K is a semi-empirical IR line list constructed for hot CO 2 spectra analysis and simulation up to 3000 – 4000 K. Compared to previously published Ames-1000K and UCL-4000, it represents a major upgrade, utilizing a new algorithm for optimization and including the latest improvements in potential energy surface (PES), dipole moment surface (DMS), and room temperature IR line list (Ames-2021 296K). To maximize the success of introducing experimental based accurate line positions, a new PES (X01d) was refined with respect to >800 selected CDSD2019 [Tashkun et al. JQSRT (2019) 228, 124] energy levels in the range of 0 – 24,000 cm -1 , with σ rms = 0.5 – 0.7 cm -1 . Most differences between the X01d PES based levels and CDSD2019 energies are within ± 2 cm -1 . A new DMS is fitted from extrapolated CCSD(T)/aug-cc-pV(T,Q,5)Z dipole calculations, with σ rms = 5.1 × 10 -6 au for 11,155 geometries up to 40,000 cm -1 , denoted Ames-2021–40K. Compared to the best available Ames-2021 DMS and room temperature IR line list [Huang et al J. Phys. Chem. A (2022) 126, 5940], the relative intensity differences are expected to be ∼ 1 ‰. The line position accuracy of ''X01d + Ames-2021–40K'' IR line list is significantly improved by adopting CDSD2019 energy levels up to 24,000 cm -1 (J ≤ 150). The Einstein A21 coefficients for E' < 15,000 cm -1 transitions are replaced by more accurate values from the Ames-2021 296K IR line list. In short, the AI-3000K is the X01d PES and Ames-2021–40K DMS based line list enhanced with the A 21 of Ames-2021 296K line list and CDSD energy levels. It provides continuous coverage from 0 to 20,000 cm -1 for the four most abundant isotopologues: 12 C 16 O 2 (626), 13 C 16 O 2 (636), 16 O 12 C 18 O (628), and 16 O 12 C 17 O (627). The impacts of isotopologue and E'/E'' cutoffs have been examined. Intensity convergence (not accuracy) of AI-3000K line list is quantitatively estimated in 1 cm -1 bins. It is better than 99% in the whole range of 0 – 20,000 (or 10,000) cm -1 at 1000 K (or 2000 K), or better than 90% in the whole range of 0 – 15,000 (or 9000) cm -1 at 2000 K (or 3000 K), respectively. Convergence beyond 3000 K will require a new PES and DMS for E' > 40,000 cm -1 . The AI-3000K and HITEMP based IR simulations are compared to high resolution shock tube experiments for CO 2 -Ar mixture up to 2000 K. With line position accuracy comparable to that of HITEMP, AI-3000K IR line list yields better agreements at more frequencies. Potential sources of discrepancies with experiment are discussed.

AI-3000K↗

Construction of a New VUV/Soft X-ray Undulator Beamline BL-13A in the Photon Factory for Study of Organic Thin Films and Biomolecules Adsorbed on Surfaces

A planar undulator beamline, BL-13A, covering 30-1,000 eV has been constructed in the Photon Factory. The main scientific targets are investigations of organic thin films and biomolecules adsorbed on well-defined surfaces using angle-resolved photoelectron spectroscopy, X-ray photoelectron spectroscopy, and X-ray absorption spectroscopy. A variable-included-angle Monk-Gillieson mounting monochromator with varied-line-spacing plane gratings is used to achieve a high photon flux of 10{sup 10}-10{sup 12} photons/s with a high resolution (E/{Delta}E) of 7,000-30,000. A typical spot size on the sample position is estimated to be 130 {mu}m (horizontal)x40 {mu}m (vertical). After commissioning, BL-13A will be open for users from January 2010.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Subpixel resolution from multiple images

Multiple images taken from similar locations and under similar lighting conditions contain similar, but not identical, information. Slight differences in instrument orientation and position produces mismatches between the projected pixel grids. These mismatches ensure that any point on the ground is sampled differently in each image. If all the images can be registered with respect to each other to a small fraction of a pixel accuracy, then the information from the multiple images can be combined to increase linear resolution by roughly the square root of the number of images. In addition, the gray-scale resolution of the composite image is also improved. We describe methods for multiple image registration and combination, and discuss some of the problems encountered in developing and extending them. We display test results with 8:1 resolution enhancement, and Viking Orbiter imagery with 2:1 and 4:1 enhancements.

Cheeseman, Peter↗

Devices and software for optical panoramic observations with microsecond time resolution

The set of equipment and software of MANIA experiment for search for and study of astrophysical objects variability with time resolution of 1 us is described. Observations are carried out at the Russian 6-meter telescope by means of universal photospectropolarimeter. This device is equipped with different optical units which implement four observational modes--spectroscopic, spectropolarimetric, photometric, and photopolarimetric. The use of position-sensitive detector with set of microchannel plates gives possibility to register object photon fluxes in different colour bands and for different orientations of polarizer simultaneously. Acquisition system ''Quantochron 4-48'' on line with computer accumulates observational data with time resolution of 1 microsecond. The features of software intended for processing of panoramic data of high time resolution are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗