Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Defining the scope for altering rice leaf anatomy to improve photosynthesis: a modelling approach

Summary Leaf structure plays an important role in photosynthesis. However, the causal relationship and the quantitative importance of any single structural parameter to the overall photosynthetic performance of a leaf remains open to debate. In this paper, we report on a mechanistic model, eLeaf, which successfully captures rice leaf photosynthetic performance under varying environmental conditions of light and CO 2 . We developed a 3D reaction‐diffusion model for leaf photosynthesis parameterised using a range of imaging data and biochemical measurements from plants grown under ambient and elevated CO 2 and then interrogated the model to quantify the importance of these elements. The model successfully captured leaf‐level photosynthetic performance in rice. Photosynthetic metabolism underpinned the majority of the increased carbon assimilation rate observed under elevated CO 2 levels, with a range of structural elements making positive and negative contributions. Mesophyll porosity could be varied without any major outcome on photosynthetic performance, providing a theoretical underpinning for experimental data. eLeaf allows quantitative analysis of the influence of morphological and biochemical properties on leaf photosynthesis. The analysis highlights a degree of leaf structural plasticity with respect to photosynthesis of significance in the context of attempts to improve crop photosynthesis.

59 BASIC BIOLOGICAL SCIENCES↗

Growth mode evolution of hafnium oxide by atomic layer deposition

HfO{sub 2} thin films were deposited using tetrakis-ethylmethylamido hafnium and H{sub 2}O as precursors on silicon by atomic layer deposition (ALD). The morphology and microstructures at different ALD cycles were characterized by atomic force microscopy and high-resolution transmission electron microscopy. Based on the height–height correlation function and power spectral density function, quantitative analysis of surface morphologies was performed. Three characteristic dimensions (ξ{sub 1}, ξ{sub 2}, and ξ{sub 3}) corresponding to three surface structures, islands, local and global fluctuations, were identified. The evolution of ALD growth mode at range of the three critical scales was investigated, respectively. It suggests the transformation of growth mode from quasi two-dimensional layer-by-layer to three-dimensional island for global fluctuations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. I. LiNi 0.8 Co 0.15 0.05 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze fresh LiNi 0.8 Co 0.1 5Al 0.05 O 2 powder obtained from TODA America. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Al 2p, Ni 3p, Co 3p, and Li 1s are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show carbon with only minor sulfur contamination. Making use of the O 1s, Al 2s, Ni 3p, Co 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiNi 0.2 Co 0.03 Al 0.1 O 0.7 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. II. LiNi 0.8 Co 0.1 Mn 0.1 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze fresh LiNi 0.8 Co 0.1 Mn 0.1 O 2 powder obtained from Targray Technology International, Inc.. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show only minor sulfur contamination. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiNi 0.4 Co 0.02 Mn 0.1 O 0.8 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. III. LiNi 0.6 Co 0.2 Mn 0.2 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze fresh LiNi 0.6 Co 0.2 Mn 0.2 O 2 powder obtained from Ecopro Company, Ltd.. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiNi 0.2 Co 0.05 Mn 0.1 O 0.7 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. IV. LiNi 0.5 Co 0.2 Mn 0.3 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze two lots of fresh LiNi 0.5 Co 0.2 Mn 0.3 O 2 powder and one of the two lot of LiNi0.5Co0.2Mn0.3O2 powder recalcined in air at 750 °C obtained from TODA America. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.83401 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show only minor sulfur contamination. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surfaces for the first lot, the first lot recalcined, and the second lot of LiNi0.3Co0.1Mn0.2O1.2, LiNi 0.4 Co 0.1 Mn 0.3 O 1.5 , and LiNi 0.4 Co 0.1 Mn 0.2 O 1.3 , respectively

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. V. LiNi 0.4 Co 0.3 0.3 O 2

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated LiNi 0.4 Co 0.3 Mn 0.3 O 2 powder obtained from TODA America. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, and Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiN i0.4 Co 0.2 Mn 0.3 O 1.6 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. VI. LiNi 0.4 Co 0.2 Mn 0.4 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze fresh LiNi 0.4 Co 0.2 Mn 0.4 O 2 powder obtained from TODA America. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiNi 0.5 Co 0.2 Mn 0.5 O 1.9 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. VII. LiNi 0.33 Co 0.33 Mn 0.33 O 2

X-ray photoelectron spectroscopy (XPS) was used to analyze fresh LiNi 0.33 Co 0.33 Mn 0.33 O 2 powder obtained from TODA America. XP spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Al 2s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiNi 0.4 Co 0.1 Mn 0.7 O 2.0 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. VIII. Li 1.2 Ni 0.15 Co 0.1 Mn 0.55 O 2

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated Li 1.2 Ni 0.15 Co 0.1 Mn 0.55 O 2 powder obtained from TODA America. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.83 01 nm. A survey spectrum together with Ni 2p, Co 2p, Mn 2p, Ni LMM, O 1s, C 1s, Ni 3s, Co 3s, Mn 3s, Ni 3p, Co 3p, Li 1s, and Mn 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals. Making use of the O 1s, Ni 3p, Co 3p, Mn 3p, and Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of Li 1.2 Ni 0.4 Co 0.2 Mn 0.9 O 2.8 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. IX. LiCoO 2

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated LiCoO 2 powder obtained from BTR New Energy Materials, Inc. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with Co 2p, O 1s, C 1s, Co 3s, Co 3p, and Li 1s are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show only minor tin contamination. Making use of the O 1s, Co 3p, and Li 1s lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surface of LiCo 0.9 O 1.7 .

25 ENERGY STORAGE↗

Lithium-based transition-metal oxides for battery electrodes analyzed by x-ray photoelectron spectroscopy. X. Li 4 Ti 5 O 12

X-ray photoelectron spectroscopy (XPS) and x-ray-induced Auger electron spectroscopy were used to analyze untreated Li 4 Ti 5 O 12 powders obtained from Ishihara Sangyo Kaisha, Ltd. and Samsung Fine Chemicals Company, Ltd. X-ray photoelectron and x-ray-induced Auger electron spectra were obtained using incident monochromatic Al Kα radiation at 0.834 01 nm. A survey spectrum together with O 1s, Ti 2p, C 1s, Ti 3s, Li 1s, and Ti 3p are presented. The spectra indicate the principal core level photoelectron and Auger electron signals and show only minor potassium signal. Making use of the O 1s, Li 1s, and Ti 3p lines and neglecting the components related to surface contaminants, XPS quantitative analysis reveals an altered stoichiometry of the air-exposed powder surfaces from Ishihara Sangyo Kaisha, Ltd. and Samsung Fine Chemicals Company, Ltd. of Li 4 Ti 4.7 O 14.1 and Li 4 Ti 4.3 O 13.2 , respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray photoelectron spectroscopy data from lightly Pd doped TiO 2 anatase nanoparticles

Here, two sets of XPS spectra from ≈13 nm slightly Pd-doped anatase TiO 2 particles are reported. Anatase is the most stable form of TiO 2 for small particles, and these spectra are the first spectra from nano-sized anatase to appear in Surface Science Spectra. The high resolution Ti 2p spectrum has an extended range showing important loss features not appearing in most of the earlier data records. The O 1s spectrum also has loss features often ignored, and in this case, the loss features are overlapped by some of the Ti 2s peak features that complicate quantitative analysis. The spectra reported here were used as example spectra in a guide to backgrounds in XPS, and the availability of these spectra in digital form allows LRH-analysts to compare their background selections and analysis approach to those discussed in the guide.

36 MATERIALS SCIENCE↗

Partial scan artifact reduction (PSAR) for the assessment of cardiac perfusion in dynamic phase-correlated CT

Purpose: Cardiac CT achieves its high temporal resolution by lowering the scan range from 2{pi} to {pi} plus fan angle (partial scan). This, however, introduces CT-value variations, depending on the angular position of the {pi} range. These partial scan artifacts are of the order of a few HU and prevent the quantitative evaluation of perfusion measurements. The authors present the new algorithm partial scan artifact reduction (PSAR) that corrects a dynamic phase-correlated scan without a priori information. Methods: In general, a full scan does not suffer from partial scan artifacts since all projections in [0, 2{pi}] contribute to the data. To maintain the optimum temporal resolution and the phase correlation, PSAR creates an artificial full scan p{sub n}{sup AF} by projectionwise averaging a set of neighboring partial scans p{sub n}{sup P} from the same perfusion examination (typically N{approx_equal}30 phase-correlated partial scans distributed over 20 s and n=1,...,N). Corresponding to the angular range of each partial scan, the authors extract virtual partial scans p{sub n}{sup V} from the artificial full scan p{sub n}{sup AF}. A standard reconstruction yields the corresponding images f{sub n}{sup P}, f{sub n}{sup AF}, and f{sub n}{sup V}. Subtracting the virtual partial scan image f{sub n}{sup V} from the artificial full scan image f{sub n}{sup AF} yields an artifact image that can be used to correct the original partial scan image: f{sub n}{sup C}=f{sub n}{sup P}-f{sub n}{sup V}+f{sub n}{sup AF}, where f{sub n}{sup C} is the corrected image. Results: The authors evaluated the effects of scattered radiation on the partial scan artifacts using simulated and measured water phantoms and found a strong correlation. The PSAR algorithm has been validated with a simulated semianthropomorphic heart phantom and with measurements of a dynamic biological perfusion phantom. For the stationary phantoms, real full scans have been performed to provide theoretical reference values. The improvement in the root mean square errors between the full and the partial scans with respect to the errors between the full and the corrected scans is up to 54% for the simulations and 90% for the measurements. Conclusions: The phase-correlated data now appear accurate enough for a quantitative analysis of cardiac perfusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scatter correction method for x-ray CT using primary modulation: Phantom studies

Purpose: Scatter correction is a major challenge in x-ray imaging using large area detectors. Recently, the authors proposed a promising scatter correction method for x-ray computed tomography (CT) using primary modulation. Proof of concept was previously illustrated by Monte Carlo simulations and physical experiments on a small phantom with a simple geometry. In this work, the authors provide a quantitative evaluation of the primary modulation technique and demonstrate its performance in applications where scatter correction is more challenging. Methods: The authors first analyze the potential errors of the estimated scatter in the primary modulation method. On two tabletop CT systems, the method is investigated using three phantoms: A Catphan(c)600 phantom, an anthropomorphic chest phantom, and the Catphan(c)600 phantom with two annuli. Two different primary modulators are also designed to show the impact of the modulator parameters on the scatter correction efficiency. The first is an aluminum modulator with a weak modulation and a low modulation frequency, and the second is a copper modulator with a strong modulation and a high modulation frequency. Results: On the Catphan(c)600 phantom in the first study, the method reduces the error of the CT number in the selected regions of interest (ROIs) from 371.4 to 21.9 Hounsfield units (HU); the contrast to noise ratio also increases from 10.9 to 19.2. On the anthropomorphic chest phantom in the second study, which represents a more difficult case due to the high scatter signals and object heterogeneity, the method reduces the error of the CT number from 327 to 19 HU in the selected ROIs and from 31.4% to 5.7% on the overall average. The third study is to investigate the impact of object size on the efficiency of our method. The scatter-to-primary ratio estimation error on the Catphan(c)600 phantom without any annulus (20 cm in diameter) is at the level of 0.04, it rises to 0.07 and 0.1 on the phantom with an elliptical annulus (30 cm in the minor axis and 38 cm in the major axis) and with a circular annulus (38 cm in diameter). Conclusions: On the three phantom studies, good scatter correction performance of the proposed method has been demonstrated using both image comparisons and quantitative analysis. The theory and experiments demonstrate that a strong primary modulation that possesses a low transmission factor and a high modulation frequency is preferred for high scatter correction accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image filtering as an alternative to the application of a different reconstruction kernel in CT imaging: Feasibility study in lung cancer screening

Purpose: While the acquisition of projection data in a computed tomography (CT) scanner is generally carried out once, the projection data is often removed from the system, making further reconstruction with a different reconstruction filter impossible. The reconstruction kernel is one of the most important parameters. To have access to all the reconstructions, either prior reconstructions with multiple kernels must be performed or the projection data must be stored. Each of these requirements would increase the burden on data archiving. This study aimed to design an effective method to achieve similar image quality using an image filtering technique in the image space, instead of a reconstruction filter in the projection space for CT imaging. The authors evaluated the clinical feasibility of the proposed method in lung cancer screening. Methods: The proposed technique is essentially the same as common image filtering, which performs processing in the spatial-frequency domain with a filter function. However, the filter function was determined based on the quantitative analysis of the point spread functions (PSFs) measured in the system. The modulation transfer functions (MTFs) were derived from the PSFs, and the ratio of the MTFs was used as the filter function. Therefore, using an image reconstructed with a kernel, an image reconstructed with a different kernel was obtained by filtering, which used the ratio of the MTFs obtained for the two kernels. The performance of the method was evaluated by using routine clinical images obtained from CT screening for lung cancer in five subjects. Results: Filtered images for all combinations of three types of reconstruction kernels (''smooth,''''standard,'' and ''sharp'' kernels) showed good agreement with original reconstructed images regarded as the gold standard. On the filtered images, abnormal shadows suspected as being lung cancers were identical to those on the reconstructed images. The standard deviations (SDs) for the difference between filtered images and reconstructed images ranged from 1.9 to 23.5 Hounsfield units for all kernel combinations; these SDs were much smaller than the noise SDs in the reconstructed images. Conclusions: The proposed method has good performance and is clinically feasible in lung cancer screening. This method can be applied to images reconstructed on any scanner by measuring the PSFs in each system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Resolution enhancement of lung 4D-CT data using multiscale interphase iterative nonlocal means

Purpose: Four-dimensional computer tomography (4D-CT) has been widely used in lung cancer radiotherapy due to its capability in providing important tumor motion information. However, the prolonged scanning duration required by 4D-CT causes considerable increase in radiation dose. To minimize the radiation-related health risk, radiation dose is often reduced at the expense of interslice spatial resolution. However, inadequate resolution in 4D-CT causes artifacts and increases uncertainty in tumor localization, which eventually results in extra damages of healthy tissues during radiotherapy. In this paper, the authors propose a novel postprocessing algorithm to enhance the resolution of lung 4D-CT data. Methods: The authors' premise is that anatomical information missing in one phase can be recovered from the complementary information embedded in other phases. The authors employ a patch-based mechanism to propagate information across phases for the reconstruction of intermediate slices in the longitudinal direction, where resolution is normally the lowest. Specifically, the structurally matching and spatially nearby patches are combined for reconstruction of each patch. For greater sensitivity to anatomical details, the authors employ a quad-tree technique to adaptively partition the image for more fine-grained refinement. The authors further devise an iterative strategy for significant enhancement of anatomical details. Results: The authors evaluated their algorithm using a publicly available lung data that consist of 10 4D-CT cases. The authors' algorithm gives very promising results with significantly enhanced image structures and much less artifacts. Quantitative analysis shows that the authors' algorithm increases peak signal-to-noise ratio by 3-4 dB and the structural similarity index by 3%-5% when compared with the standard interpolation-based algorithms. Conclusions: The authors have developed a new algorithm to improve the resolution of 4D-CT. It outperforms the conventional interpolation-based approaches by producing images with the markedly improved structural clarity and greatly reduced artifacts.

60 APPLIED LIFE SCIENCES↗

Performance of 12 DIR algorithms in low-contrast regions for mass and density conserving deformation

Purpose: Deformable image registration (DIR) has become a key tool for adaptive radiotherapy to account for inter- and intrafraction organ deformation. Of contemporary interest, the application to deformable dose accumulation requires accurate deformation even in low contrast regions where dose gradients may exist within near-uniform tissues. One expects high-contrast features to generally be deformed more accurately by DIR algorithms. The authors systematically assess the accuracy of 12 DIR algorithms and quantitatively examine, in particular, low-contrast regions, where accuracy has not previously been established.Methods: This work investigates DIR algorithms in three dimensions using deformable gel (DEFGEL) [U. J. Yeo, M. L. Taylor, L. Dunn, R. L. Smith, T. Kron, and R. D. Franich, “A novel methodology for 3D deformable dosimetry,” Med. Phys. 39, 2203–2213 (2012)], for application to mass- and density-conserving deformations. CT images of DEFGEL phantoms with 16 fiducial markers (FMs) implanted were acquired in deformed and undeformed states for three different representative deformation geometries. Nonrigid image registration was performed using 12 common algorithms in the public domain. The optimum parameter setup was identified for each algorithm and each was tested for deformation accuracy in three scenarios: (I) original images of the DEFGEL with 16 FMs; (II) images with eight of the FMs mathematically erased; and (III) images with all FMs mathematically erased. The deformation vector fields obtained for scenarios II and III were then applied to the original images containing all 16 FMs. The locations of the FMs estimated by the algorithms were compared to actual locations determined by CT imaging. The accuracy of the algorithms was assessed by evaluation of three-dimensional vectors between true marker locations and predicted marker locations.Results: The mean magnitude of 16 error vectors per sample ranged from 0.3 to 3.7, 1.0 to 6.3, and 1.3 to 7.5 mm across algorithms for scenarios I to III, respectively. The greatest accuracy was exhibited by the original Horn and Schunck optical flow algorithm. In this case, for scenario III (erased FMs not contributing to driving the DIR calculation), the mean error was half that of the modified demons algorithm (which exhibited the greatest error), across all deformations. Some algorithms failed to reproduce the geometry at all, while others accurately deformed high contrast features but not low-contrast regions—indicating poor interpolation between landmarks.Conclusions: The accuracy of DIR algorithms was quantitatively evaluated using a tissue equivalent, mass, and density conserving DEFGEL phantom. For the model studied, optical flow algorithms performed better than demons algorithms, with the original Horn and Schunck performing best. The degree of error is influenced more by the magnitude of displacement than the geometric complexity of the deformation. As might be expected, deformation is estimated less accurately for low-contrast regions than for high-contrast features, and the method presented here allows quantitative analysis of the differences. The evaluation of registration accuracy through observation of the same high contrast features that drive the DIR calculation is shown to be circular and hence misleading.

61 RADIATION PROTECTION AND DOSIMETRY↗