Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Diffracted X-ray tracking for monitoring intramolecular motion in individual protein molecules using broad band X-ray

Diffracted X-ray tracking (DXT) enables the tilting and twisting motions of single protein molecules to be monitored with micro- to milliradian resolution using a highly brilliant X-ray source with a wide energy bandwidth. We have developed a technique to monitor single molecules using gold nanocrystals attached to individual protein molecules using the BL28B2 beamline at SPring-8. In this paper we present the installation of a single toroidal X-ray mirror at BL28B2 to focus X-rays in an energy range of 10–20 keV (△E/E = 82% for an X-ray with a wide energy bandwidth). With this beamline we tracked diffraction spots from gold nanocrystals over a wide angle range than that using quasi-monochromatic X-rays. Application of the wide angle DXT technique to biological systems enabled us to observe the on-site motions of single protein molecules that have been functionalized in vivo. We further extend the capability of DXT by observing the fractional tilting and twisting motions of inner proteins under various conditions. As a proof of this methodology and to determine instrumental performance the intramolecular motions of a human serum albumin complex with 2-anthracenecarboxylic acid was investigated using the BL28B2 beamline. The random tilting and twisting intramolecular motions are shown to be directly linked to the movement of individual protein molecules in the buffer solution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An experimental evaluation of monochromatic x-ray beam position monitors at diamond light source

Maintaining the stability of the X-ray beam relative to the sample point is of paramount importance for beamlines and users wanting to perform cutting-edge experiments. The ability to detect, and subsequently compensate for, variations in X-ray beam position with effective diagnostics has multiple benefits: a reduction in commissioning and start-up time, less ‘down-time’, and an improvement in the quality of acquired data. At Diamond Light Source a methodical evaluation of a selection of monochromatic X-ray Beam Position Monitors (XBPMs), using a range of position detection techniques, and from a range of suppliers, was carried out. The results of these experiments are presented, showing the measured RMS noise on the position measurement of each device for a given flux, energy, beam size, and bandwidth. A discussion of the benefits and drawbacks of each of the various devices and techniques is also included.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Filterscope diagnostic system on the Experimental Advanced Superconducting Tokamak (EAST)

A filterscope diagnostic system has been mounted to observe the line emission and visible bremsstrahlung emission from plasma on the experimental advanced superconducting tokamak during the 2014 campaign. By this diagnostic system, multiple wavelengths including D{sub α} (656.1 nm), D{sub γ} (433.9 nm), He II (468.5 nm), Li I (670.8 nm), Li II (548.3 nm), C III (465.0 nm), O II (441.5 nm), Mo I (386.4 nm), W I (400.9 nm), and visible bremsstrahlung radiation (538.0 nm) are monitored with corresponding wavelength filters. All these multi-channel signals are digitized at up to 200 kHz simultaneously. This diagnostic plays a crucial role in studying edge localized modes and H-mode plasmas, due to the high temporal resolution and spatial resolution that have been designed into it.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MULTI-WAVELENGTH OBSERVATIONS OF SUPERNOVA 2011ei: TIME-DEPENDENT CLASSIFICATION OF TYPE IIb AND Ib SUPERNOVAE AND IMPLICATIONS FOR THEIR PROGENITORS

We present X-ray, UV/optical, and radio observations of the stripped-envelope, core-collapse supernova (SN) 2011ei, one of the least luminous SNe IIb or Ib observed to date. Our observations begin with a discovery within {approx}1 day of explosion and span several months afterward. Early optical spectra exhibit broad, Type II-like hydrogen Balmer profiles that subside rapidly and are replaced by Type Ib-like He-rich features on a timescale of one week. High-cadence monitoring of this transition suggests absorption attributable to a high-velocity ({approx}> 12, 000 km s{sup -1}) H-rich shell, which is likely present in many Type Ib events. Radio observations imply a shock velocity of v Almost-Equal-To 0.13 c and a progenitor star average mass-loss rate of M-dot {approx}1.4 Multiplication-Sign 10{sup -5} M{sub sun} yr{sup -1} (assuming wind velocity v{sub w} = 10{sup 3} km s{sup -1}). This is consistent with independent constraints from deep X-ray observations with Swift-XRT and Chandra. Overall, the multi-wavelength properties of SN 2011ei are consistent with the explosion of a lower-mass (3-4 M{sub Sun }), compact (R{sub *} {approx}< 1 Multiplication-Sign 10{sup 11} cm), He-core star. The star retained a thin hydrogen envelope at the time of explosion, and was embedded in an inhomogeneous circumstellar wind suggestive of modest episodic mass loss. We conclude that SN 2011ei's rapid spectral metamorphosis is indicative of time-dependent classifications that bias estimates of the relative explosion rates for Type IIb and Ib objects, and that important information about a progenitor star's evolutionary state and mass loss immediately prior to SN explosion can be inferred from timely multi-wavelength observations.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-C-BRD-06: Sensitivity Study of An Automated System to Acquire and Analyze EPID Exit Dose Images

Purpose: The dosimetric consequences of errors in patient setup or beam delivery and anatomical changes are not readily known. A new product, PerFRACTION (Sun Nuclear Corporation), is designed to detect these errors by comparing the EPID exit dose image from each field of each fraction to those from baseline fraction images. This work investigates the sensitivity of PerFRACTION to detect the deviation of induced errors in a variety of realistic scenarios. Methods: Eight plans were created mimicking potential delivery or setup errors. The plans consisted of a nominal field and the field with an induced error. These were used to irradiate the EPID simulating multiple fractions with and without the error. Integrated EPID images were acquired in clinical mode and saved in ARIA. PerFRACTION automatically pulls the images into its database and performs the user defined comparison. In some cases, images were manually pushed to PerFRACTION. We varied the distance-to-agreement or dose tolerance until PerFRACTION showed failing pixels in the affected region and recorded the values. We induced errors of 1mm and greater in jaw, MLC, and couch position, 2 degree collimation rotation (patient yaw), and 0.5% to 1.5% in machine output. Both static and arc fields with the rails in or out were also acquired and compared. Results: PerFRACTION detected position errors of the jaws, MLC, and couch with an accuracy of better than 0.5 mm, and 0.2 degrees for collimator and gantry error. PerFRACTION detected a machine output error within 0.2% and detected the change in rail position. Conclusion: A new automated system for monitoring daily treatments for machine or patient variations from the first fraction using integrated EPID images was found to be sensitive enough to detect small positional, angular, and dosimetric errors within 0.5mm, 0.2 degrees, and 0.2%, respectively. Sun Nuclear Corporation has provided a software license for the product described.

60 APPLIED LIFE SCIENCES↗

Beam’s-eye-view imaging during non-coplanar lung SBRT

Purpose: Beam’s-eye-view (BEV) imaging with an electronic portal imaging device (EPID) can be performed during lung stereotactic body radiation therapy (SBRT) to monitor the tumor location in real-time. Image quality for each patient and treatment field depends on several factors including the patient anatomy and the gantry and couch angles. The authors investigated the angular dependence of automatic tumor localization during non-coplanar lung SBRT delivery. Methods: All images were acquired at a frame rate of 12 Hz with an amorphous silicon EPID. A previously validated markerless lung tumor localization algorithm was employed with manual localization as the reference. From ten SBRT patients, 12 987 image frames of 123 image sequences acquired at 48 different gantry–couch rotations were analyzed. δ was defined by the position difference of the automatic and manual localization. Results: Regardless of the couch angle, the best tracking performance was found in image sequences with a gantry angle within 20° of 250° (δ = 1.40 mm). Image sequences acquired with gantry angles of 150°, 210°, and 350° also led to good tracking performances with δ = 1.77–2.00 mm. Overall, the couch angle was not correlated with the tracking results. Among all the gantry–couch combinations, image sequences acquired at (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) led to the best tracking results with δ = 1.19–1.82 mm. The worst performing combinations were (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) with δ > 3.5 mm. However, 35% (17/48) of the gantry–couch rotations demonstrated substantial variability in tracking performances between patients. For example, the field angle (θ = 70°, ϕ = 10°) was acquired for five patients. While the tracking errors were ≤1.98 mm for three patients, poor performance was found for the other two patients with δ ≥ 2.18 mm, leading to average tracking error of 2.70 mm. Only one image sequence was acquired for all other gantry–couch rotations (δ = 1.18–10.29 mm). Conclusions: Non-coplanar beams with gantry–couch rotation of (θ = 30°, ϕ = 330°), (θ = 210°, ϕ = 10°), and (θ = 250°, ϕ = 30°) have the highest accuracy for BEV lung tumor localization. Additionally, gantry angles of 150°, 210°, 250°, and 350° also offer good tracking performance. The beam geometries (θ = 90° and 230°, ϕ = 10°) and (θ = 270°, ϕ = 30°) are associated with substantial automatic localization errors. Overall, lung tumor visibility and tracking performance were patient dependent for a substantial number of the gantry–couch angle combinations studied.

60 APPLIED LIFE SCIENCES↗

Nonstationary Infrared Testing of Coatings on Exterior and Interior Surfaces of Metal Shells

A new method for nondestructive testing of coatings on exterior and interior surfaces of metal shells is proposed that is based on video monitoring of the infrared radiation emitted from the shell excited by shortterm external heating. Computer processing of the measured nonstationary field of temperature distribution on the outer surface allows defects with lateral dimensions on the order of or greater than the shell thickness to be revealed on the inner (inaccessible to observation) surface. Geometric characteristics of these defects can be evaluated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tunable Q-Factor Gas-Filled RF Cavity

Fermilab is the main institution to produce the most powerful and wide-spectrum neutrino beam. From that respective, a radiation robust beam diagnostic system is a critical element in order to maintain the quality of the neutrino beam. Within this context, a novel radiation-resistive beam profile monitor based on a gas-filled RF cavity has been proposed. The goal of this measurement is to study a tunable Q-factor RF cavity to determine the accuracy of the RF signal as a function of the quality factor. Specifically, the measurement error of the Q-factor in the RF calibration is investigated. Then, the RF system will be improved to minimize signal error.

43 PARTICLE ACCELERATORS↗

Survey of Current and Future PMT Replacement Technology

Photomultiplier tubes (PMTs) are the most commonly used instrument to monitor scintillating materials for radiation detection purposes. The International Atomic Energy Agency has identified disadvantages in PMTs that may degrade their performance, including temperature dependence and variation with magnetic field. Instrumentation engineering must also contend with a potentially large volume relative to the active scintillator volume, fragility, and high voltage requirements. Because of these concerns, we have studied emerging alternatives to PMTs that mitigate at least some of these disadvantages. To be of interest, the alternatives must have performance and cost comparable to the PMTs, and either be commercially available or close to commercial production. The best alternative we have identified is an array of silicon photomultipliers (SiPMs), with a potential secondary near-future alternative being a large-area picosecond photodetector. We compared the performance of a SiPM and a PMT in a laboratory setting using a single 2”x 2” cylindrical sodium iodide scintillating crystal. We measured the full-width, half-maximum energy resolution with the PMT and SiPM at 662 keV to be 6.14 ± 0.02% and 6.29 ± 0.03%, respectively, and at 1332 keV to be 4.61 ± 0.06% and 4.49 ± 0.05%, respectively. We also demonstrated how the SiPM bias can be varied to remove temperature dependence in cases either where the rate of temperature change is slow or the dwell time is sufficiently long to allow the system to come to thermal equilibrium.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development Plan for Acoustic Emission and Vibration Sensors

This document discusses the need for high temperature, radiation tolerant sensors for monitoring vibration and acoustic emissions in advanced reactors and irradiation experiments. Testing of several commercial sensors using infrastructure available at Idaho National Laboratory was performed to benchmark currently available sensors as well as the test facilities. Finally, a strategy for developing sensors for more extreme environments is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MODIS Airborne simulator (MAS) Final Report for CLASIC

The MAS was flown aboard the NASA ER-2 for the CLASIC field experiment, and for all data collected, provided calibrated and geolocated (Level-1B) radiance data for it’s 50 spectral bands (ranging in wavelength for 0.47 to 14.3 µm). From the Level-1B data, as directed in the Statement of Work, higher order (Level-2) data products were derived. The Level-2 products include: a) cloud optical thickness, b) cloud effective radius, c) cloud top height (temperature), d) cloud fraction, e) cloud phase products. Preliminary Level-1B and Level-2 products were provided during the field experiment (typically within one or two days of data collection). Final version data products were made available in December 2008 following considerable calibration analysis. Data collection, data processing (to Level-2), and discussion of the calibration work are summarized below.

54 ENVIRONMENTAL SCIENCES↗

System selects framing rate for spectrograph camera

Circuit using zero-order light is reflected to a photomultiplier in the incoming radiation of a spectrograph monitor to provide an error signal which controls the advancing and driving rate of the film through the camera.

Source record↗

Testing the Fraunhofer line discriminator by sensing fluorescent dye

The experimental Fraunhofer Line Discriminator (FLD) has detected increments of Rhodamine WT dye as small as 1 ppb in 1/2 meter depths. It can be inferred that increments considerably smaller than 1 ppb will be detectable in depths considerably greater than 1/2 meter. Turbidity of the water drastically reduces luminescence or even completely blocks the transmission of detectable luminescence to the FLD. Attenuation of light within the water by turbidity and by the dye itself are the major factors to be considered in interpreting FLD records and in relating luminescence coefficient to dye concentration. An airborne test in an H-19 helicopter established feasibility of operating the FLD from the aircraft power supply, and established that the rotor blades do not visibly affect the monitoring of incident solar radiation.

Stoertz, G. E.↗

Solar mesosphere explorer: Experiment description

The Solar Mesosphere Explorer (SME) satellite experiments will provide a comprehensive study of atmospheric ozone and the processes which form and destroy it. Five instruments to be carried on the spacecraft will measure the ozone density and altitude distribution, monitor the incoming solar radiation, and measure other atmospheric constituents which affect ozone. The investigative approach concept, methods and procedures, preflight studies, and orbits and mission lifetime are presented. Descriptions of the instruments are also presented.

Source record↗

Solar Mesosphere Explorer mission

The Solar Mesosphere Explorer (SME) satellite experiments will provide a comprehensive study of atmospheric ozone and the processes which form and destroy it. Five instruments to be carried on the spacecraft will measure the ozone density and altitude distribution, monitor the incoming solar radiation, and measure other atmospheric constituents which affect ozone. The first objective of the SME satellite experiments is to determine what changes occur in the ozone distribution as a result of changes in the incoming solar radiation. A second objective is to measure all changes in the ozone density distribution in the altitude range of 30 to 80 km and to determine the causes of these changes.

Stuart, J. R.↗

CCE plasma wave observations during the storm of September 4, 5, 1984

Near 0700 on September 4, 1984 a series of interplanetary discontinuities arrived at earth when the AMPTE Charge Composition Explorer (CCE) was near apogee. During the next few hours the spacecraft passed in and out of the magnetosheath. At the magnetopause boundary, the CCE wave instrument detected strong electron plasma oscillations, weaker electromagnetic waves at the electron plasma frequency, and broadband electrostatic waves. During the subsequent perigee passes on September 4 and 5, the wave observations of upper hybrid resonance emissions, continuum radiation, electrostatic noise bands and unusual low latitude auroral kilometic radiation were used to monitor significant variations in the magnetospheric characteristics as the main storm phases developed.

Scarf, F. L.↗

An investigation of the energy balance of solar active regions using the ACRIM irradiance data

The correlation between the irradiance (as measured by the Active Cavity Radiometer Irradiance Monitor and the Earth Radiation Budget) as corrected for sunspot flux deficit (which is responsible for most of the variance of the uncorrected signal) and both the 205 nm flux (as measured by Nimbus 7) and a photometric facular index is discussed. The computer program which simulates two-dimensional convection in a compressible, stratified medium is described. Equipment which was acquired to perform high precision, white-light observations of sunspot areas, and procedures were tested. Analysis of observations of large scale convective heat inhomogeneities which were obtained in May 1985 was begun.

Petro, L. D.↗

Infrared observations of planetary atmospheres

Infrared data was obtained on planetary atmospheres which provides critical information on atmospheric structure, composition, and cloud properties in support of planetary missions such as Voyager and Galileo. Mapping of Jupiter and Saturn in thermal and reflected solar radiation is a high-priority monitoring and exploratory activity. Some of these images of Jupiter are shown. Radiation at 17.8 micrometer probes the upper tropospheric temperature structure where spatial structure bears a strong resemblance to visible and near-infrared reflected sunlight such as at 2.0 micrometer. At 7.8 micrometer, stratospheric temperatures appear to have a three-banded structure, enhancements near the magnetic poles and occasional transient features such as the equatorial filament near the right limb. Clouds or hazes are observed high in the stratosphere looking at wavelengths such as 2.2 micrometer, where gaseous opacity is very strong. Other maps examine cloud properties from thermal radiation not strongly influenced by gaseous opacity and the distribution of condensable gases, such as ammonia. Millimeter and submillimeter filtered radiometric observations were made of Jupiter, Uranus and Neptune via collaborative work. Radiometric observations of Uranus and Neptune at 21 and 32 micrometer were acquired and analyzed as well as grating array spectra in the ranges of 8 to 14 micrometer, 16 to 23 micrometer, and 18 to 32 micrometer. These showed evidence for C2H2 in the stratosphere of Uranus and C2H4 in the stratosphere of Neptune.

Orton, G. S.↗