Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiator Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

DESIGN AND PRELIMINARY TEST OF THE 1500 MHZ NSLS-II PASSIVE SUPERCONDUCTING RF CAVITY

NSLS-II is a new ultra-bright 3 GeV 3rd generation synchrotron radiation light source. The performance goals require operation with a beam current of 500mA and a bunch current of at least 0.5mA. Ion clearing gaps are required to suppress ion effects on the beam. The natural bunch length of 3mm is planned to be lengthened by means of a third harmonic cavity in order to increase the Touschek limited lifetime. Earlier work described the design alternatives and the geometry selected for a copper prototype. We subsequently have iterated the design to lower the R/Q of the cavity and to increase the diameter of the beam pipe ferrite HOM dampers to reduce the wakefield heating. A niobium cavity and full cryomodule including LN2 shield, magnetic shield and insulating vacuum vessel have been fabricated and installed. A passive SRF 3rd harmonic cavity consisting of two tightly coupled cells has been designed and fabricated for NSLS-II. Initial cold tests of this cavity are very promising. These tests have verified that the cavity frequency and mode separation between the 0 and {pi}-modes can be set at manufacture. Further, the frequency separation can be maintained over wide tuning ranges necessary for operation. Future work includes HOM damper and motorized tuner development.

3 GeV 3rd generation synchrotron↗

Review and Performance Testing of the Optical Power Monitor (PMON)

The LISA mission requires a high precision optical power monitoring and control system that combines high reliability and measurement accuracy with extremely low disturbance to the core interferometric detection system. NASA is working with Avo Photonics to design and build this optical power monitor, known as PMON. The high-level design requirements take into account detector redundancy, mechanical rigidity, stability against temperature and input alignment changes, parasitic scatter and reflection artifacts, as well as low magnetic field. Gamma and Proton radiation tests have been performed on the photodiodes from a few vendors to verify radiation tolerance. Engineering development units of the PMON have been fabricated, delivered and evaluated at NASA.

Hua Jiao↗

Incidence of Second Malignancies Among Patients Treated With Proton Versus Photon Radiation

Purpose: Proton radiation, when compared with photon radiation, allows delivery of increased radiation dose to the tumor while decreasing dose to adjacent critical structures. Given the recent expansion of proton facilities in the United States, the long-term sequelae of proton therapy should be carefully assessed. The objective of this study was to compare the incidence of second cancers in patients treated with proton radiation with a population-based cohort of matched patients treated with photon radiation. Methods and Materials: We performed a retrospective cohort study of 558 patients treated with proton radiation from 1973 to 2001 at the Harvard Cyclotron in Cambridge, MA and 558 matched patients treated with photon therapy in the Surveillance, Epidemiology, and End Results (SEER) Program cancer registry. Patients were matched by age at radiation treatment, sex, year of treatment, cancer histology, and site. The main outcome measure was the incidence of second malignancies after radiation. Results: We matched 558 proton patients with 558 photon patients from the Surveillance, Epidemiology, and End Results registry. The median duration of follow-up was 6.7 years (interquartile range, 7.4) and 6.0 years (interquartile range, 9.3) in the proton and photon cohorts, respectively. The median age at treatment was 59 years in each cohort. Second malignancies occurred in 29 proton patients (5.2%) and 42 photon patients (7.5%). After we adjusted for sex, age at treatment, primary site, and year of diagnosis, proton therapy was not associated with an increased risk of second malignancy (adjusted hazard ratio, 0.52 [95% confidence interval, 0.32-0.85]; P=.009). Conclusions: The use of proton radiation therapy was not associated with a significantly increased risk of secondary malignancies compared with photon therapy. Longer follow-up of these patients is needed to determine if there is a significant decrease in second malignancies. Given the limitations of the study, these results should be viewed as hypothesis generating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temperature threshold for preferential bubble formation on grain boundaries in tungsten under in-situ helium irradiation

Understanding a material's radiation tolerance requires examining its performance under different irradiation conditions. In this work, we investigate the radiation tolerance in terms of helium bubble damage in tungsten irradiated in-situ with 16 keV helium at 1073 K and 1223 K. Damage evolution represented by helium bubble density, size and total change in volume in the grain matrices and the grain boundaries are quantified as a function of fluence. Preferential large bubble formation and a higher change in volume on the grain boundaries occurred at 1223 K, suggesting faster migration of certain helium-vacancy complexes as confirmed by a diffusion-reaction model.

36 MATERIALS SCIENCE↗

All-optical phase conjugation using diffractive wavefront processing

Abstract Optical phase conjugation (OPC) is a nonlinear technique used for counteracting wavefront distortions, with applications ranging from imaging to beam focusing. Here, we present a diffractive wavefront processor to approximate all-optical phase conjugation. Leveraging deep learning, a set of diffractive layers was optimized to all-optically process an arbitrary phase-aberrated input field, producing an output field with a phase distribution that is the conjugate of the input wave. We experimentally validated this wavefront processor by 3D-fabricating diffractive layers and performing OPC on phase distortions never seen during training. Employing terahertz radiation, our diffractive processor successfully performed OPC through a shallow volume that axially spans tens of wavelengths. We also created a diffractive phase-conjugate mirror by combining deep learning-optimized diffractive layers with a standard mirror. Given its compact, passive and multi-wavelength nature, this diffractive wavefront processor can be used for various applications, e.g., turbidity suppression and aberration correction across different spectral bands.

42 ENGINEERING↗

Light in the darkening on Naica gypsum crystals

Naica mine is located in a semi-desertic region at the central-south of Chihuahua State. The Cave of Swords was discovered in 1910 and the Cave of Crystals 90 years later at Naica mines. It is expected that during the last century the human presence has changed the microclimatic conditions inside the cave, resulting in the deterioration of the crystals and the deposition of impurities on gypsum surfaces. As a contribution to the clarification of the mentioned issues, the present work refers to the use of synchrotron radiation for the identification of phases on these surfaces. All the experiments were performed at the Stanford Synchrotron Radiation Lightsource. Grazing incidence X-ray diffraction (GIXRD) and radiography-aided X-ray diffraction (RAXRD) experiments were performed at beamline 11-3. X-Ray micro-fluorescence (μ-SXRF) and micro-X-ray absorption (μ-XANES) were measured at beamline 2-3. Representative results obtained may be summarized as follows: a) Gypsum, galena, sphalerite, hematite and cuprite at the surface of the gypsum crystals were determined. b) The samples micro-structure is affected by impurities. c) The elemental distributions and correlations (0.6-0.9) of Cu, K, Fe, Mn, Pb, Zn, Ca and S were identified by μ-SXRF. The correlations among elemental contents confirmed the phase identification, with the exception of manganese and potassium due to the amorphous nature of some impurity compounds in these samples. The compounds hematite (Fe{sub 2}O{sub 3}), β-MnO{sub 2}, Mn{sub 2}O{sub 3}, MnO and/or MnCO{sub 3}, PbS, PbCO{sub 3} and/or PbSO4, ZnO{sub 4}, ZnS and/or smithsonite (ZnCO{sub 3}), CuS + Cu Oxide were identified by XANES. Plausibly, these latter compounds do not form crystalline phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A detailed modeling study of radiative heat transfer in a heavy-duty diesel engine

In recent years, the importance of radiative heat transfer in combustion has been increasingly recognized. Detailed models have become available that accurately represent the complex spectral radiative properties of reacting gas mixtures and soot particles, and new methods have been developed to solve the radiative transfer equation (RTE). At the same time, the trends toward higher operating pressures and higher levels of exhaust-gas recirculation in compression-ignition engines, together with the demand for higher quantitative accuracy from in-cylinder CFD models, has led to renewed interest in radiative transfer in engines. In this report an in-depth investigation of radiative heat transfer is performed for a heavy-duty diesel truck engine over a range of operating conditions. Results from 10 different combinations of turbulent combustion models, spectral radiation property models, and RTE solvers are compared to provide insight into the global influences of radiation on energy redistribution in the combustion chamber, heat losses, and engine-out pollutant emissions (NO and soot). Also, the relative importance of the individual contributions of molecular gas versus soot radiation, the spectral model, the RTE solver, and unresolved turbulent fluctuations in composition and temperature (turbulence–radiation interactions – TRI) are investigated. Local instantaneous temperatures change by as much as 100 K with consideration of radiation, but the global influences of radiation on heat losses and engine-out emissions are relatively small (in the 5–10% range). Molecular gas radiation dominates over soot radiation, consideration of spectral properties is essential for accurate predictions of reabsorption, a simple RTE solver (a first-order spherical harmonics – P1 – method) is sufficient for the conditions investigated, and TRI effects are small (less than 10%). While the global influences of radiation are relatively small, it is nevertheless desirable to explicitly account for radiation in in-cylinder CFD. To that end, a simplified CFD radiation model has been proposed, based on the findings reported here.

42 ENGINEERING↗

A Block-Structured Adaptive Mesh Framework to Solve Radiation Transfer Equation in Irregular Embedded Geometries

Radiation transport arises in various scientific, industrial, and medical fields, and understanding its effect in applications is needed to make accurate predictions, safety assessments and performance optimizations. Solving the Radiation Transport Equation (RTE) is challenging due to its integro-differential nature, which involves both differential and integral terms. The differential term describes the change in radiation intensity due to absorption and emission, while the integral term accounts for scattering. The accurate modeling of radiation is further complicated in many applications due to the complex, irregular geometries. Various methods exist for solving the RTE, including the zonal, Monte Carlo, spherical harmonics, discrete ordinates, and finite volume methods. Traditional mesh-based approaches, which rely on structured or unstructured meshes, struggle with irregular geometries due to: a) the difficulty of conforming structured grids to irregular domains, b) challenges in enforcing boundary conditions correctly, and c) the additional computational cost of unstructured mesh methods. This work presents a second-order accurate method for solving the RTE in irregular geometries. The radiation intensity is discretized using the finite-volume method in both spatial and angular directions on regular Cartesian grid blocks. Leveraging the block-structured adaptive mesh refinement (AMR) framework provided by AMReX, our method refines the grid locally to reduce spatial discretization error, ensuring a converged numerical solution while minimizing computational costs elsewhere. A two-stage deferred correction approach is employed: First, a first-order discretization on grid blocks is solved using an algebraic multigrid method in HYPRE. Second, a correction term is applied explicitly to achieve second-order accuracy. The correction term is calculated by approximating the radiation flux on cell faces using a Total Variation Diminishing (TVD) scheme. This approach ensures quick convergence of the multigrid method while preserving higher-order accuracy of the numerical solution. Irregular geometries are resolved as embedded boundaries (EB), resulting in both cut cells and regular cells. In cut cells, we modify the fluxes using face fractions and incorporate additional contributions from EB boundary conditions. To ensure higher-order convergence near the EB interface, the correction term is modified by interpolating the radiation intensity to fictitious ghost points. The implementation takes advantage of modern supercomputers by leveraging AMReX’sMPI/X parallelization strategy where X can be MPI or a GPU accelerator including CUDA, HIP and DPC++. We validate our solver using classical test cases, both with and without EB, demonstrating accuracy and efficiency. Additionally, we analyze the impact of adaptive mesh refinement on solution accuracy and computational cost, highlighting the advantages of our approach for high-resolution radiation transport simulations.

computational fluid dynamics (CFD)↗

Pressure Systems Energy Release Protection (Gas Pressurized Systems)

A survey of studies into hazards associated with closed or pressurized system rupture and preliminary guidelines for the performance design of primary, secondary, and protective receptors of these hazards are provided. The hazards discussed in the survey are: blast, fragments, ground motion, heat radiation, biological, and chemical. Performance guidelines for receptors are limited to pressurized systems that contain inert gas. The performance guidelines for protection against the remaining unaddressed degenerative hazards are to be covered in another study.

Brown, S. J.↗

On Computationally Efficient Radiative Transfer Calculations for Three-dimensional Entry Problems

The current work presents an efficient simulation framework for rigorously modeling radiative fields emanating from non-equilibrium planetary entry flows in complex three-dimensional domains. Key to this endeavor is adoption of finite-volume discretization in lieu of brute-force ray tracing. This change in conjunction with mesh sweeping and Lebedev-type quadrature for angular integration allows spatial-angular resolution of radiative transfer to be performed in a computationally tractable manner. Additionally, a new methodology has been established to build standalone reduced-order spectral databases for non-equilibrium radiative properties that can be applied to a broad range of hypersonic planetary entry problems with minimal loss in accuracy. The efficacy of the new framework has been demonstrated on the atomic nitrogen radiative system. The resulting reduced-order model requires three orders-of-magnitude fewer spectral evaluations and results in a 95% decrease in memory footprint. A comparative study for representative forebody and afterbody lines-of-sight from Stardust, FIRE II, and meteor entries into the Earth atmosphere indicates that both total intensity variation and detailed spectra can be retrieved with as few as 625 reduced-order groups (contrasting with the 100,000 frequencies in the original full set model). Similarly, three-dimensional predictions of radiative heating experienced by the Orion forebody are in excellent agreement with legacy radiation solvers while requiring only a sliver (roughly 0.5%) of computing wall time.

3D radiation↗

On Computationally Efficient Radiative Transfer Calculations for Three-Dimensional Entry Problems

The current work presents an efficient simulation framework for rigorously modeling radiative fields emanating from non-equilibrium planetary entry flows in complex three-dimensional domains. Key to this endeavor is adoption of finite-volume discretization in lieu of brute-force ray tracing. This change in conjunction with mesh sweeping and Lebedev-type quadrature for angular integration allows spatial-angular resolution of radiative transfer to be performed in a computationally tractable manner. Additionally, a new methodology has been established to build standalone reduced-order spectral databases for non-equilibrium radiative properties that can be applied to a broad range of hypersonic planetary entry problems with minimal loss in accuracy. The efficacy of the new framework has been demonstrated on the atomic nitrogen radiative system. The resulting reduced-order model requires three orders-of-magnitude fewer spectral evaluations and results in a 95% decrease in memory footprint. A comparative study for representative forebody and afterbody lines-of-sight from Stardust, FIRE II, and meteor entries into the Earth atmosphere indicates that both total intensity variation and detailed spectra can be retrieved with as few as 625 reduced-order groups (contrasting with the 100,000 frequencies in the original full set model). Similarly, three-dimensional predictions of radiative heating experienced by the Orion forebody are in excellent agreement with legacy radiation solvers while requiring only a sliver (roughly 0.5%) of computing wall time.

3D radiation↗

Microstructural Injury to Corpus Callosum and Intrahemispheric White Matter Tracts Correlate With Attention and Processing Speed Decline After Brain Radiation

The corpus callosum (CC) and intrahemispheric white matter tracts (IHWM) subserve critical aspects of attention and processing speed. We analyzed imaging biomarkers of microstructural injury within these regions and association with attention and processing speed performance before and after radiation therapy in primary brain tumor patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improvements to the Ionizing Radiation Risk Assessment Program for NASA Astronauts

To perform dosimetry and risk assessment, NASA collects astronaut ionizing radiation exposure data from space flight, medical imaging and therapy, aviation training activities and prior occupational exposure histories. Career risk of exposure induced death (REID) from radiation is limited to 3 percent at a 95 percent confidence level. The Radiation Health Office at Johnson Space Center (JSC) is implementing a program to integrate the gathering, storage, analysis and reporting of astronaut ionizing radiation dose and risk data and records. This work has several motivations, including more efficient analyses and greater flexibility in testing and adopting new methods for evaluating risks. The foundation for these improvements is a set of software tools called the Astronaut Radiation Exposure Analysis System (AREAS). AREAS is a series of MATLAB(Registered TradeMark)-based dose and risk analysis modules that interface with an enterprise level SQL Server database by means of a secure web service. It communicates with other JSC medical and space weather databases to maintain data integrity and consistency across systems. AREAS is part of a larger NASA Space Medicine effort, the Mission Medical Integration Strategy, with the goal of collecting accurate, high-quality and detailed astronaut health data, and then securely, timely and reliably presenting it to medical support personnel. The modular approach to the AREAS design accommodates past, current, and future sources of data from active and passive detectors, space radiation transport algorithms, computational phantoms and cancer risk models. Revisions of the cancer risk model, new radiation detection equipment and improved anthropomorphic computational phantoms can be incorporated. Notable hardware updates include the Radiation Environment Monitor (which uses Medipix technology to report real-time, on-board dosimetry measurements), an updated Tissue-Equivalent Proportional Counter, and the Southwest Research Institute Radiation Assessment Detector. Also, the University of Florida hybrid phantoms, which are flexible in morphometry and positioning, are being explored as alternatives to the current NASA computational phantoms.

Semones, E. J.↗

High-energy radiographic imaging performance of LYSO

Here, a comprehensive comparison of the dominant sources of radiation-induced blur for radiographic imaging system performance is made. End-point energies of 6, 10, 15, and 20 MeV bremsstrahlung photon radiation produced at the Los Alamos National Laboratory Microtron facility were used to examine the performance of large-panel cerium-doped lutetium yttrium silicon oxide (LYSO:Ce) scintillators 3, 5 and 10 mm thick. The system resolution was measured and compared between the various end-point energies and scintillator thicknesses. Contrary to expectations, it is found that there was only a minor dependence of system resolution on scintillator thickness or beam end-point energy. This indicates that increased scintillator thickness does not have a dramatic effect on system performance. The data are then compared to Geant4 simulations to assess contributions to the system performance through the examination of modulation transfer functions. It was determined that the low-frequency response of the system is dominated by the radiation-induced signal, while the higher-frequency response of the system is dominated by the optical imaging of the scintillation emission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel facility for ageing materials with narrow-band ultraviolet radiation exposure

A facility for exploring wavelength dependencies in ultraviolet (UV) radiation induced degradation in materials has been designed and constructed. The device is essentially a spectrograph separating light from a lamp to spectrally resolved UV radiation. It is based on a 1 kW xenon lamp and a flat-field concave holographic grating 10 cm in diameter. Radiation at the wavelength range 250-500 nm is dispersed onto the sample plane of 1.5 cm in height and 21 cm in width. The optical performance of the device has been characterized by radiometric measurements. Using the facility, test samples prepared of regular newspaper have been irradiated from 1 to 8 h. Color changes on the different locations of the aged samples have been quantified by color measurements. Yellowness indices computed from the color measurements demonstrate the capability of the facility in revealing wavelength dependencies of the material property changes in reasonable time frames.

36 MATERIALS SCIENCE↗

Response of Silicon-Based Linear Energy Transfer Spectrometers: Implication for Radiation Risk Assessment in Space Flights

There is considerable interest in developing silicon-based telescopes because of their compactness and low power requirements. Three such telescopes have been flown on board the Space Shuttle to measure the linear energy transfer spectra of trapped, galactic cosmic ray, and solar energetic particles. Dosimeters based on single silicon detectors have also been flown on the Mir orbital station. A comparison of the absorbed dose and radiation quality factors calculated from these telescopes with that estimated from measurements made with a tissue equivalent proportional counter show differences which need to be fully understood if these telescopes are to be used for astronaut radiation risk assessments. Instrument performance is complicated by a variety of factors. A Monte Carlo-based technique was developed to model the behavior of both single element detectors in a proton beam, and the performance of a two-element, wide-angle telescope, in the trapped belt proton field inside the Space Shuttle. The technique is based on: (1) radiation transport intranuclear-evaporation model that takes into account the charge and angular distribution of target fragments, (2) Landau-Vavilov distribution of energy deposition allowing for electron escape, (3) true detector geometry of the telescope, (4) coincidence and discriminator settings, (5) spacecraft shielding geometry, and (6) the external space radiation environment, including albedo protons. The value of such detailed modeling and its implications in astronaut risk assessment is addressed. c2001 Elsevier Science B.V. All rights reserved.

manned↗

Pilot Study: Unique Response of Bone Tissue During an Investigation of Radio-Adaptive Effects in Mice

PURPOSE: We obtained bone tissue to evaluate the collateral effects of experiments designed to investigate molecular mechanisms of radio-adaptation in a mouse model. Radio-adaptation describes a process by which the prior exposure to low dose radiation can protect against the toxic effect of a subsequent high dose exposure. In the radio-adaptation experiments, C57Bl/6 mice were exposed to either a Sham or a priming Low Dose (5 cGy) of Cs-137 gamma rays before being exposed to either a Sham or High Dose (6 Gy) 24 hours later. ANALYSIS: Bone tissue were obtained from two experiments where mice were sacrificed at 3 days (n=3/group, 12 total) and at 14 days (n=6/group, 24 total) following high dose exposure. Tissues were analyzed to 1) evaluate a radio-adaptive response in bone tissue and 2) describe cellular and microstructural effects for two skeletal sites with different rates of bone turnover. One tibia and one lumbar vertebrae (LV2), collected at the 3-day time-point, were analyzed by bone histomorphometry and micro-CT to evaluate the cellular response and any evidence of microarchitectural impact. Likewise, tibia and LV2, collected at the 14-day time-point, were analyzed by micro-CT alone to evaluate resulting changes to bone structure and microarchitecture. The data were analyzed by 2-way ANOVA to evaluate the effects of the priming low dose radiation, of the high dose radiation, and of any interaction between the priming low and high doses of radiation. Bone histomorphometry was performed in the cancellous bone (aka trabecular bone) compartments of the proximal tibial metaphysis and of LV2. RESULTS: Cellular Response @ 3 Days The priming Low Dose radiation decreased osteoblast-covered bone perimeter in the proximal tibia and the total cell density in the bone marrow in the LV2. High Dose radiation, regardless of prior exposure to priming dose, dramatically reduced total cell density in bone marrow of both the long bone and vertebra. However, in the proximal tibia, High Dose radiation increased the osteoclast-covered bone perimeters, the density of adipocytes in bone marrow, and the area of bone marrow occupied by fat cells -- while in the LV2, adipocytes were rare and not stimulated by High Dose radiation. In an unexpected response, High Dose radiation dramatically increased (10-fold) osteoblast-covered bone perimeter in the LV2.

Sibonga, J. D.↗

Modelling the performance of the tapered artery heat pipe design for use in the radiator of the solar dynamic power system of the NASA Space Station

The paper presents a computer program developed to model the steady-state performance of the tapered artery heat pipe for use in the radiator of the solar dynamic power system of the NASA Space Station. The program solves six governing equations to ascertain which one is limiting the maximum heat transfer rate of the heat pipe. The present model appeared to be slightly better than the LTV model in matching the 1-g data for the standard 15-ft test heat pipe.

Evans, Austin Lewis↗