Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Search for New Physics in the Dijet Mass Distribution using 1 fb − 1 of p p Collision Data at s = 7 TeV collected by the ATLAS Detector

CERN-LHC. Measurement of the mass distribution of di-jets produced in proton proton collisions at a centre-of-mass energy of 7 TeV. The data set has a total integrated luminosity of 1.0 fb-1 and dijet masses up to 4 GeV are used in the search of resonance production of new particles above background. Jets are reconstructed using the anti-kt clustering algorithm with the parameter R=0.6.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for direct top squark pair production in final states with one isolated lepton, jets, and missing transverse momentum in s = 7 TeV p p collisions using 4.7 f b − 1 of ATLAS data

CERN-LHC. A study of data from proton-proton collisions at a centre-of-mass energy of 7 TeV having final states consisting of one isolated electron or muon, jets and missing trasnverse momentum using a data sample of total integrated luminosity of 4.7 fb-1. Each event must have >=1 reconstructed primary vertex associated with five or more tracks with PT > 0.4 GeV. Events must have exactly one muon (or electron) with |eta|<2.4 (or 2.47) and pT > 20 (or 25) GeV and isolated from other particles. The scalar sum of the pT of tracks >1 GeV within a cone of size deltaR=0.2 around the lepton candidate is required to be < 10% of the electron pT, and <1.8 Gev for the muon. jets are reconstructed using the ant-kT clustering algorithm with radius parameter=0.4. Events with four or more jets with |eta|<2.5 and pT> 80,60,40,and 25 GeV are selected with at least one jet identified as a b-jet.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kalman-filtered compressive sensing for high resolution estimation of anthropogenic greenhouse gas emissions from sparse measurements.

The estimation of fossil-fuel CO2 emissions (ffCO2) from limited ground-based and satellite measurements of CO2 concentrations will form a key component of the monitoring of treaties aimed at the abatement of greenhouse gas emissions. The limited nature of the measured data leads to a severely-underdetermined estimation problem. If the estimation is performed at fine spatial resolutions, it can also be computationally expensive. In order to enable such estimations, advances are needed in the spatial representation of ffCO2 emissions, scalable inversion algorithms and the identification of observables to measure. To that end, we investigate parsimonious spatial parameterizations of ffCO2 emissions which can be used in atmospheric inversions. We devise and test three random field models, based on wavelets, Gaussian kernels and covariance structures derived from easily-observed proxies of human activity. In doing so, we constructed a novel inversion algorithm, based on compressive sensing and sparse reconstruction, to perform the estimation. We also address scalable ensemble Kalman filters as an inversion mechanism and quantify the impact of Gaussian assumptions inherent in them. We find that the assumption does not impact the estimates of mean ffCO2 source strengths appreciably, but a comparison with Markov chain Monte Carlo estimates show significant differences in the variance of the source strengths. Finally, we study if the very different spatial natures of biogenic and ffCO2 emissions can be used to estimate them, in a disaggregated fashion, solely from CO2 concentration measurements, without extra information from products of incomplete combustion e.g., CO. We find that this is possible during the winter months, though the errors can be as large as 50%.

Ray, Jaideep↗

3 TeV jgun collisions, Single jet type, JET GUN generator: jgun_jet_single_pt3tev

Single jet gun for detector studies: The events contain a single jets from all QCD processes at 14 TeV pp collisions. Events were simulated using the Pythia8 A2 pp tune for 14 TeV. Jets were reconstructed using the anti-kT fastjet algorithm with R=0.4 and pT above 3 TeV (all eta). Then only one jet per event was taken. All particles that fall outside the cone 0.1 around the jet center were removed. The sample with jet cores is designed for detector performance studies to reduce simulation step.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Materials Identification System for 200 liter/55 gallon Waste Drums using Computer Tomographic Techniques - 17162

In 2014 a thermal runaway event within a drum in-situ at the Waste Isolation Pilot Plant (WIPP) facility near Carlsbad, NM, resulted in the drum being breached and activity released. This emphasized the need for a better determination of drum contents and identification of material combinations and in-drum conditions. Enhanced characterization is required to identify and quantify the presence of absorbent materials, determine whether they are organic or inorganic, locate their position in the drum with respect to other materials, and quantify how much liquid is being held in the absorbent material. As part of the waste characterization process to ensure compliance with the WIPP waste acceptance criteria, drums are currently inspected by Real Time Radioscopic (RTR) x-ray to identify prohibited items such as free liquids and un-punctured aerosol cans, but that technique cannot satisfy these newly identified requirements, and a new approach to non-destructive examination was required. This approach complements the current RTR inspection with Cone-Beam Area Detector Computed Tomography (CT) scanning of the whole drum, followed by more-quantitative CT scanning of specific areas of concern, using a highly collimated Linear Detector Array. The density of representative waste drums required x-ray energies of up to 9 MeV, which meant that sorting of materials by their photo-electric absorption is not viable as this occurs in the 80 - 180 keV range. However, a notable characteristic of higher energy imaging in this context is the general correspondence between material density and total attenuation in the 1.5-4.0 MeV range due to Compton Scatter. Development of the imaging chain, comprising the x-ray source and the detectors was critical to achieving the required system performance. Theoretical analysis of the energy spectra of the 9 MeV beam, and filtration of the beam to remove the lower energies which cause beam hardening artifacts in the image was required. Theoretical evaluation of the required efficiency and image acquisition performance of area detectors and linear array detectors, was carried out to complete the selection of equipment. A system of density calibration rods was designed and, together with the selected equipment, was configured and used to acquire cone-beam CT data and line-scan CT data by scanning a 55 gallon drum containing surrogate waste. From the acquired data, CT reconstruction was performed and the basis of algorithms to identify materials were developed. Following this, a series of blind tests were done using a range of surrogate materials the contents of which were unknown to the system operators. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of fast tomographic methods for application on the Soft X-Ray Tomography System on Wendelstein 7-X stellarator

The Wendelstein 7-X stellarator, presently under construction in Greifswald, is foreseen to operate on a steady state regime. Under such a scenario, a constant diagnosis of the plasma characteristics is strongly envisaged. A X-Ray Tomography diagnostic is a particularly useful tool since a poloidal cross-section of the plasma's X-Ray emissivity can be reconstructed and the plasma's position as well as MHD activity can be inferred.Fast tomographic algorithms such as the Cormack inversion or neural networks (NN) can be applied to obtain recon-structions at a human time scale (10{approx}100 reconstructions per second). This paper discusses the potential application of these algorithms on the Wendelstein 7-X stellarator by comparing performance and reliability of the results. The NN reconstruction has proven to be faster and more reliable than the Cormack's.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma-ray tracking for high energy gamma-ray imaging in pixelated CdZnTe

Sequencing gamma-ray interactions within a detector system is an integral component of Compton imaging. In detectors with poor timing resolution compared to the time interval of successive interactions, algorithms which order gamma-ray interactions must be implemented using only energy and position information. This work examines previous algorithms and inspects interaction kinematics to increase the sequencing algorithm’s speed and effectiveness. The proposed method, in which the first interaction is assumed to deposit the largest energy, has improved sequencing performance by greater than 20% for full energy gamma ray depositions larger than 1 MeV that do not contain pair-production. In addition, the algorithm shows a decrease in computational costs for sequence reconstruction to allow for better real time reconstruction. Experimental results show an almost twofold increase in the signal to noise ratio (SNR) for simple backprojection images of a 22 Na source. Additional measurements of the 2.2 MeV gamma rays from H 1 (n,$\gamma$)D 2 neutron capture demonstrates the proposed algorithm’s superior performance.

3D position sensitive CdZnTe↗

Jet reconstruction and performance using particle flow with the ATLAS Detector

This paper describes the implementation and performance of a particle flow algorithm applied to 20.2 fb –1 of ATLAS data from 8 TeV proton–proton collisions in Run 1 of the LHC. The algorithm removes calorimeter energy deposits due to charged hadrons from consideration during jet reconstruction, instead using measurements of their momenta from the inner tracker. This improves the accuracy of the charged-hadron measurement, while retaining the calorimeter measurements of neutral-particle energies. The paper places emphasis on how this is achieved, while minimising double-counting of charged-hadron signals between the inner tracker and calorimeter. In conclusion, the performance of particle flow jets, formed from the ensemble of signals from the calorimeter and the inner tracker, is compared to that of jets reconstructed from calorimeter energy deposits alone, demonstrating improvements in resolution and pile-up stability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Boosting the signal-to-noise of low-field MRI with deep learning image reconstruction

Recent years have seen a resurgence of interest in inexpensive low magnetic field (< 0.3 T) MRI systems mainly due to advances in magnet, coil and gradient set designs. Most of these advances have focused on improving hardware and signal acquisition strategies, and far less on the use of advanced image reconstruction methods to improve attainable image quality at low field. We describe here the use of our end-to-end deep neural network approach (AUTOMAP) to improve the image quality of highly noise-corrupted low-field MRI data. We compare the performance of this approach to two additional state-of-the-art denoising pipelines. We find that AUTOMAP improves image reconstruction of data acquired on two very different low-field MRI systems: human brain data acquired at 6.5 mT, and plant root data acquired at 47 mT, demonstrating SNR gains above Fourier reconstruction by factors of 1.5- to 4.5-fold, and 3-fold, respectively. In these applications, AUTOMAP outperformed two different contemporary image-based denoising algorithms, and suppressed noise-like spike artifacts in the reconstructed images. The impact of domain-specific training corpora on the reconstruction performance is discussed. The AUTOMAP approach to image reconstruction will enable significant image quality improvements at low-field, especially in highly noise-corrupted environments.

42 ENGINEERING↗

Semiautomatic method to identify the best phase for gated RT in lung region by 4D-PET/CT acquisitions

Purpose: Delineating tumor motion by four-dimensional positron emission tomography/computed tomography (4D-PET/CT) is a crucial step for gated radiotherapy (RT). This article quantitatively evaluates semiautomatic algorithms for tumor shift estimation in the lung region due to patient respiration by 4D-PET/CT, in order to support the selection of the best phases for gated RT, by considering the most stable phases of the breathing cycle. Methods: Three mobile spheres and ten selected lesions were included in this study. 4D-PET/CT data were reconstructed and classified into six/ten phases. The semiautomatic algorithms required the generation of single sets of images representative of the full target motion, used as masks for segmenting the phases. For 4D-CT, a pre-established HU range was used, whereas three thresholds (100%, 80%, and 40%) were evaluated for 4D-PET. By using these segmentations, the authors estimated the lesion motion from the shifting centroids, and the phases with the least motion were also deduced including the phases with a curve slope less than 2 mm/{Delta}phase. The proposed algorithms were validated by comparing the results to those generated entirely by manual contouring. Results: In the phantom study, the mean difference between the manual contour and the semiautomatic technique was 0.1{+-}0.1 mm for 4D-CT and 0.2{+-}0.1 mm for the 4D-PET based on 40% threshold. In the patients' series, the mean difference was 0.9{+-}0.6 mm for 4D-CT and 0.8{+-}0.2 mm for the 4D-PET based on 40% threshold. Conclusions: Estimation of lesion motion by the proposed semiautomatic algorithm can be used to evaluate tumor motion due to breathing.

60 APPLIED LIFE SCIENCES↗

Photon Reconstruction and Identification with the ATLAS detector

The understanding of the photons reconstruction will be one of the key issues at the start-up of data-taking with the ATLAS experiment at the LHC. Large statistics samples of photons produced in association with jets are expected over a wide range of E{sub T}.The photon reconstruction is based on an electromagnetic-cluster-seeded algorithm which classifies as photons those clusters which have no matching prompt track. These are then subdivided into converted or non-converted photon candidates depending on the presence of one or more tracker-reconstructed electron-positron pairs pointing to it. The precise knowledge of the material upstream the calorimeter and a correct treatment of the converted photons are critical for a correct photon reconstruction and identification.The photon identification is based almost entirely on the analysis of the shower shapes in the calorimeter. The goal is to achieve an efficient photon selection in the range from 20 GeV to several hundreds GeV with a rejection of 10{sup 3}-10{sup 4} against QCD jets in the moderate transverse momentum region of 20 to 100 GeV, which is the relevant one for H->gammagamma searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-BRE-06: Evaluation of Patient CT Dose Reconstruction From 3D Diode Array Measurements Using Anthropomorphic Phantoms

Purpose: To compare 3D reconstructed dose of IMRT plans from 3D diode array measurements with measurements in anthropomorphic phantoms. Methods: Six IMRT plans were created for the IROC Houston (RPC) head and neck (H and N) and lung phantoms following IROC Houston planning protocols. The plans included flattened and unflattened beam energies ranging from 6 MV to 15 MV and both static and dynamic MLC tecH and Niques. Each plan was delivered three times to the respective anthropomorphic phantom, each of which contained thermoluminescent dosimeters (TLDs) and radiochromic films (RCFs). The plans were also delivered to a Delta4 diode array (Scandidos, Uppsala, Sweden). Irradiations were done using a TrueBeam STx (Varian Medical Systems, Palo Alto, CA). The dose in the patient was calculated by the Delta4 software, which used the diode measurements to estimate incident energy fluence and a kernel-based pencil beam algorithm to calculate dose. The 3D dose results were compared with the TLD and RCF measurements. Results: In the lung, the average difference between TLDs and Delta4 calculations was 5% (range 2%–7%). For the H and N, the average differences were 2.4% (range 0%–4.5%) and 1.1% (range 0%–2%) for the high- and low-dose targets, respectively, and 12% (range 10%-13%) for the organ-at-risk simulating the spinal cord. For the RCF and criteria of 7%/4mm, 5%/3mm, and 3%/3mm, the average gamma-index pass rates were 95.4%, 85.7%, and 76.1%, respectively for the H and N and 76.2%, 57.8%, and 49.5% for the lung. The pass-rate in the lung decreased with increasing beam energy, as expected for a pencil beam algorithm. Conclusion: The H and N phantom dose reconstruction met the IROC Houston acceptance criteria for clinical trials; however, the lung phantom dose did not, most likely due to the inaccuracy of the pencil beam algorithm in the presence of low-density inhomogeneities. Work supported by PHS grant CA10953 and CA81647 (NCI, DHHS)

60 APPLIED LIFE SCIENCES↗

Metropolis–Hastings Monte Carlo Method for Neutron Emissivity Tomographic Inversion in Tokamak Plasma

The article presents a new approach to plasma neutron emissivity reconstruction based on the Metropolis–Hastings Monte Carlo algorithm. The algorithm is based on a biased random walk. A dedicated computer code generates pseudo-random samples within the domain that contains the solution. The properly chosen objective function ensures convergence to the desired solution. The method allows to overcome the problem of trapping in local minima by accepting, with some finite probability, changes in the direction opposite to that indicated by the objective function. The developed method was tested using a synthetic data set. The results show that the method provides reliable reconstructions and thus can be used as an alternative or complementary method to the commonly applied ones. The method capabilities were also tested against noise present in the line-integrated projections.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter

A novel method to reconstruct the energy of hadronic showersin the CMS High Granularity Calorimeter (HGCAL) is presented. TheHGCAL is a sampling calorimeter with very fine transverse andlongitudinal granularity. The active media are silicon sensors andscintillator tiles readout by SiPMs and the absorbers are acombination of lead and Cu/CuW in the electromagnetic section, andsteel in the hadronic section. The shower reconstruction method isbased on graph neural networks and it makes use of a dynamicreduction network architecture. It is shown that the algorithm isable to capture and mitigate the main effects that normally hinderthe reconstruction of hadronic showers using classicalreconstruction methods, by compensating for fluctuations in themultiplicity, energy, and spatial distributions of the shower'sconstituents. The performance of the algorithm is evaluated usingtest beam data collected in 2018 prototype of the CMS HGCALaccompanied by a section of the CALICE AHCAL prototype. Thecapability of the method to mitigate the impact of energy leakagefrom the calorimeter is also demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Deep Neural Network for Simultaneous Estimation of b Jet Energy and Resolution

We describe a method to obtain point and dispersion estimates for the energies of jets arising from b quarks produced in proton–proton collisions at an energy of $\sqrt{s}=13\,\text {TeV} $ at the CERN LHC. The algorithm is trained on a large sample of simulated b jets and validated on data recorded by the CMS detector in 2017 corresponding to an integrated luminosity of 41 $\,\text {fb}^{-1}$. A multivariate regression algorithm based on a deep feed-forward neural network employs jet composition and shape information, and the properties of reconstructed secondary vertices associated with the jet. The results of the algorithm are used to improve the sensitivity of analyses that make use of b jets in the final state, such as the observation of Higgs boson decay to $\hbox {b}\bar{\hbox {b}}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction of Large Radius Tracks with the Exa.TrkX pipeline

Particle tracking is a challenging pattern recognition task at the Large Hadron Collider (LHC) and the High Luminosity-LHC. Conventional algorithms, such as those based on the Kalman Filter, achieve excellent performance in reconstructing the prompt tracks from the collision points. However, they require dedicated configuration and additional computing time to efficiently reconstruct the large radius tracks created away from the collision points. We developed an end-to-end machine learning-based track finding algorithm for the HL-LHC, the Exa.TrkX pipeline. The pipeline is designed so as to be agnostic about global track positions. In this work, we study the performance of the Exa.TrkX pipeline for finding large radius tracks. Trained with all tracks in the event, the pipeline simultaneously reconstructs prompt tracks and large radius tracks with high efficiencies. This new capability offered by the Exa.TrkX pipeline may enable us to search for new physics in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An algorithm to estimate the object support in truncated images

Purpose: Truncation artifacts in CT occur if the object to be imaged extends past the scanner field of view (SFOV). These artifacts impede diagnosis and could possibly introduce errors in dose plans for radiation therapy. Several approaches exist for correcting truncation artifacts, but existing correction algorithms do not accurately recover the skin line (or support) of the patient, which is important in some dose planning methods. The purpose of this paper was to develop an iterative algorithm that recovers the support of the object. Methods: The authors assume that the truncated portion of the image is made up of soft tissue of uniform CT number and attempt to find a shape consistent with the measured data. Each known measurement in the sinogram is interpreted as an estimate of missing mass along a line. An initial estimate of the object support is generated by thresholding a reconstruction made using a previous truncation artifact correction algorithm (e.g., water cylinder extrapolation). This object support is iteratively deformed to reduce the inconsistency with the measured data. The missing data are estimated using this object support to complete the dataset. The method was tested on simulated and experimentally truncated CT data. Results: The proposed algorithm produces a better defined skin line than water cylinder extrapolation. On the experimental data, the RMS error of the skin line is reduced by about 60%. For moderately truncated images, some soft tissue contrast is retained near the SFOV. As the extent of truncation increases, the soft tissue contrast outside the SFOV becomes unusable although the skin line remains clearly defined, and in reformatted images it varies smoothly from slice to slice as expected. Conclusions: The support recovery algorithm provides a more accurate estimate of the patient outline than thresholded, basic water cylinder extrapolation, and may be preferred in some radiation therapy applications.

60 APPLIED LIFE SCIENCES↗