Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability model generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Robust PV Degradation Methodology and Application

The degradation rate plays an important role in predicting and assessing the long-term energy generation of PV systems. Many methods have been proposed for extracting the degradation rate from operational data of PV systems, but most of the published approaches are susceptible to bias due to inverter clipping, module soiling, temporary outages, seasonality, and sensor degradation. In this manuscript, we propose a methodology for determining PV degradation leveraging available modeled clear-sky irradiance data rather than site sensor data, and a robust year-over-year (YOY) rate calculation. We show the method to provide reliable degradation rate estimates even in the case of sensor drift, data shifts, and soiling. Compared with alternate methods, we demonstrate that the proposed method delivers the lowest uncertainty in degradation rate estimates for a fleet of 486 PV systems.

14 SOLAR ENERGY↗

Impact of Glen Canyon Generation Loss

Colorado River Basin hydropower generation has faced challenges due to droughts and ecological and social water requirements. Specifically, Glen Canyon hydropower generation fluctuates substantially with recent extreme weather trends. Further, the western grid evolves with higher wind and solar share, and Glen Canyon hydropower's contribution to grid flexibility services is essential. The Western Area Power Administration (WAPA) markets and schedules electricity production at GCD, and the loss of this power could have significant financial consequences for the WAPA Colorado River Storage Project's (CRSP) Office because it may need to purchase relatively large amounts of energy to serve its firm electrical obligations. In addition, GCD provides grid reliability services for the WAPA Colorado-Missouri (WACM) balancing authority (BA). Both WAPA and DOE's Water & Power Technology Office (WPTO) are interested in researching how these drier hydrological conditions will impact federal electrical energy production, the Western Electricity Coordinating Council (WECC) power grid, and the value of hydropower in the face of lower production. We study multiple hydrologic and power grid scenarios to understand the grid impacts of the loss of Glen Canyon generation. The study uses a production cost model, water resources planning models, water-centric grid models, and various data analytic techniques. The study progress presentation discusses the selection of probable CRSP' hydropower scenarios and power grid scenarios to understand the impacts of Glen Canyon generation, which includes technologies that compensate the Glen Canyon energy and ancillary services contributions, transmission availability, and energy local marginal prices at interested grid locations of WAPA operation.

droughts↗

Development of Supervisory Control System for Thermal Energy Distribution System

The integrated energy system (IES) refers to the combination of nuclear energy generation with other energy sources to enable the efficiency and reliability of power generations. To create technologically viable and economically competitive systems, supervisory control strategies are critical for optimizing performance and ensuring stability across different energy generation, transportation, and utilization. This work focuses on the control strategies for the thermal energy distribution system (TEDS), which is a cornerstone of the Dynamic Energy Transport and Integration Laboratory at Idaho National Laboratory. TEDS currently relies on operators to coordinate across different components to manage energy storage and ensure efficiency. This work demonstrates the use of model predictive control (MPC) with surrogate models in determining optimal setpoints for major TEDS components. The capability of MPC-based supervisory control system is evaluated by autonomously matching the power outputs from a Dymola-based TEDS with target heat demands.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis and Test of a Proton Exchange Membrane Fuel Cell Power System for Space Power Applications

An effort is underway to develop a prototype Proton Exchange Membrane (PEM) Fuel Cell breadboard system for fuhlre space applications. This prototype will be used to develop a comprehensive design basis for a space-rated PEM fuel cell powerplant. The prototype system includes reactant pressure regulators, ejector-based reactant pumps, a 4-kW fuel cell stack and cooling system, and a passive, membranebased oxygen / water separator. A computer model is being developed concurrently to analytically predict fluid flow in the oxidant reactant system. Fuel cells have historically played an important role in human-rated spacecraft. The Gemini and Apollo spacecraft used fuel cells for vehicle electrical power. The Space Shuttle currently uses three Alkaline Fuel Cell Powerplants (AFCP) to generate all of the vehicle's 15-20kW electrical power. Engineers at the Johnson Space Center have leveraged off the development effort ongoing in the commercial arena to develop PEM fuel cel ls for terrestrial uses. The prototype design originated from efforts to develop a PEM fuel cell replacement for the current Space Shuttle AFCP' s. In order to improve on the life and an already excellent hi storical record of reliability and safety, three subsystems were focused on. These were the fuel cell stack itself, the reactant circulation devices, and reactant / product water separator. PEM fuel cell stack performance is already demonstrating the potential for greater than four times the useful life of the current Shuttle's AFCP. Reactant pumping for product water removal has historically been accomplished with mechanical pumps. Ejectors offer an effective means of reactant pumping as well as the potential for weight reduction, control simplification, and long life. Centrifugal water separation is used on the current AFCP. A passive, membrane-based water separator offers compatibility with the micro-gravity environment of space, and the potential for control simplification, elimination of moving parts in an oxygen environment, and long life. The prototype system has been assembled from components that have previously been tested and evaluated at the component level. Preliminary data obtained from tests performed with the prototype system, as well as other published data, has been used to validate the analytical component models. These components have been incorporated into an integrated oxidant fluid system model. Results obtained from both the performance tests and the analytical model are presented.

Vasquez, Arturo↗

Developing Fault Models for Space Mission Software

A viewgraph presentation on the development of fault models for space mission software is shown. The topics include: 1) Goal: Improve Understanding of Technology Fault Generation Process; 2) Required Measurement; 3) Measuring Structural Evolution; 4) Module Attributes; 5) Principal Components of Raw Metrics; 6) The Measurement Process; 7) View of Structural Evolution at the System and Module Level; 8) Identifying and Counting Faults; 9) Fault Enumeration; 10) Modeling Fault Content; 11) Modeling Results; 12) Current and Future Work; and 13) Discussion and Conclusions.

software measurements↗

High Penetration of Photovoltaic Generation Study – Flagstaff Community Power (Final Technical Report, Results of Phases 2-5)

APS’s renewable energy portfolio, driven in part by Arizona’s Renewable Energy Standard (RES) currently includes more than 1100 MW of installed capacity, equating to roughly 3000 GWh of annual production. Overall renewable production is expected to grow to 6000 GWh by 2025. It is expected that distributed photovoltaics, driven primarily by lower cost, will contribute to much of this growth and that by 2025, distributed installations will account for half of all renewable production (3000GHW). As solar penetration increases, additional analysis may be required for routine utility processes to ensure continued safe and reliable operation of the electric distribution network. Such processes include residential or commercial interconnection requests and load shifting during normal feeder operations. Circuits with existing high solar penetration will also have to be studied and results will need to be evaluated for adherence to utility practices or strategy. Increased distributed PV penetration may offer benefits such as load offsetting, but it also has the potential to adversely impact distribution system operation. These effects may be exacerbated by the rapid variability of PV production. Detailed effects of these phenomena in distributed PV applications continue to be studied. Comprehensive, high-resolution electrical models of the distribution system were developed to analyze the impacts of PV on distribution circuit protection systems (including coordination and anti-islanding), predict voltage regulation and phase balance issues, and develop volt/VAr control schemes. Modeling methods were refined by validating against field measurements. To augment the field measurements, methods were developed to synthesize high resolution load and PV generation data to facilitate quasi-static time series simulations. The models were then extended to explore boundary conditions for PV hosting capability of the feeder and to simulate common utility practices such as feeder reconfiguration. The modeling and analysis methodology was implemented using open source tools and a process was developed to aid utility engineers in future interconnection requests. Methods to increase PV hosting capacity were also explored during the course of the study. A 700kVA grid-supportive inverter was deployed on the feeder and each grid support mode was demonstrated. Energy storage was explored through simulation and models were developed to calculate the optimum size and placement needed to increase PV hosting capacity. A tool was developed to aid planners in assigning relative costs and benefits to various strategies for increasing PV hosting capacity beyond current levels. Following the completion of the project, APS intends to use the tools and methods to improve the framework of future PV integration on its system. The tools and methods are also expected to aid other utilities to accelerate distributed PV deployment.

14 SOLAR ENERGY↗

Resilience Design Patterns: A Structured Approach to Resilience at Extreme Scale (V.2.0)

Reliability is a serious concern for future extreme-scale high-performance computing (HPC) systems. Projections based on the current generation of HPC systems and technology roadmaps suggest the prevalence of very high fault rates in future systems. The errors resulting from these faults will propagate and generate various kinds of failures, which may result in outcomes ranging from result corruptions to catastrophic application crashes. Therefore, the resilience challenge for extreme-scale HPC systems requires coordination between various hardware and software technologies that are capable of handling a broad set of fault models at accelerated fault rates. Also, due to practical limits on power consumption in future HPC systems, they are likely to embrace innovative architectures, increasing the levels of hardware and software complexities. Therefore, the techniques that seek to improve resilience must navigate the complex trade-off space between resilience and the overheads to power consumption and performance. While the HPC community has developed various resilience solutions, application-level techniques as well as system-based solutions, the solution space of HPC resilience techniques remains fragmented. There are no formal methods to integrate the various HPC resilience techniques into composite solutions, nor are there methods to holistically evaluate the adequacy and efficacy of such solutions in terms of their protection coverage, and their performance & power efficiency characteristics. Additionally, few implementations of current resilience solutions are portable to newer architectures and software environments that will be deployed on future systems. We developed a new structured approach to the management of HPC resilience using the concept of resilience-based design patterns. In general, a design pattern is a repeatable solution to a commonly occurring problem. We identified the well-known solutions that are commonly used to deal with faults, errors and failures in HPC systems. In the initial design patterns specification (version 1.0), we described the various solutions, which address specific problems in the design of resilient HPC environments, in the form of patterns. Each pattern describes a problem caused by a fault, error or failure event in an HPC environment, and then describes the core of the solution of the problem in such a way that this solution may be adapted to different systems and implemented at different layers of the system stack. The catalog of these resilience design patterns provides designers with a collection of design elements. To construct complete resilience solutions using combinations of various patterns, we defined a framework that enhances HPC designers' understanding of the important constraints and the opportunities for the design patterns to be implemented and deployed at various layers of the system stack. The design framework is also useful for establishing interfaces and mechanisms to coordinate flexible fault management across hardware and software components, as well as to consider the trade-off between performance, resilience, and power consumption when constructing a solution. The resilience design patterns specification version 1.1 included more detailed explanations of the pattern solutions, the context in which the patterns are applicable, and the implications for hardware or software design. It also provided several additional examples and detailed case studies to demonstrate the use of patterns to build realistic solutions. In version 1.2 of the specification document, we have improved the pattern descriptions, including graphical representations of the pattern components. These improvements are largely based on critical comments, feedback and suggestions received from pattern experts and readers of the previous versions of the specification. The pattern classification has been modified to further clarify the relationships between pattern categories. This version of the specification also introduces a pattern language for resilience design patterns. The pattern language presents the patterns in the catalog as a network, revealing the relations among the resilience patterns. The language provides designers with the means to explore alternative techniques for handling a specific fault model that may have different efficiency and complexity characteristics. Using the pattern language also enables the design and implementation of comprehensive resilience solutions as a set of interconnected resilience patterns that can be instantiated across layers of the system stack. The overall goal of this work is to provide hardware and software designers, as well as the users and operators of HPC systems, a systematic methodology for the design and evaluation of resilience technologies in HPC systems that keep scientific applications running to a correct solution in a timely and cost-efficient manner despite frequent faults, errors, and failures of various types. Version 2.0 expands the resilience design pattern classification and catalog to include self-stabilization patterns and reliability, availability and performance models for each structural pattern.

97 MATHEMATICS AND COMPUTING↗

Heavy Ion Reaction Modeling for Hadrontherapy Applications

A comprehensive and reliable description of nucleus-nucleus interactions represents a crucial need in different interdisciplinary fields. In particular, hadrontherapy monitoring by means of in-beam positron emission tomography (PET) requires, in addition to measuring, the capability of calculating the activity of {beta}{sup +}-decaying nuclei produced in the irradiated tissue. For this purpose, in view of treatment monitoring at the Heidelberg Ion Therapy (HIT) facility, the transport and interaction Monte Carlo code FLUKA is a promising candidate. It is provided with the description of heavy ion reactions at intermediate and low energies by two specific event generators. In-beam PET experiments performed at GSI for a few beam-target combinations have been simulated and first comparisons between the measured and calculated {beta}{sup +}-activity are available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Unit-Level Changes in Operations with Increased SPP Wind from EPRI/LCG Balancing Study

Wind power development in the United States is outpacing previous estimates for many regions, particularly those with good wind resources. The pace of wind power deployment may soon outstrip regional capabilities to provide transmission and integration services to achieve the most economic power system operation. Conversely, regions such as the Southeastern United States do not have good wind resources and will have difficulty meeting proposed federal Renewable Portfolio Standards with local supply. There is a growing need to explore innovative solutions for collaborating between regions to achieve the least cost solution for meeting such a renewable energy mandate. The Department of Energy funded the project 'Integrating Midwest Wind Energy into Southeast Electricity Markets' to be led by EPRI in coordination with the main authorities for the regions: SPP, Entergy, TVA, Southern Company and OPC. EPRI utilized several subcontractors for the project including LCG, the developers of the model UPLAN. The study aims to evaluate the operating cost benefits of coordination of scheduling and balancing for Southwest Power Pool (SPP) wind transfers to Southeastern Electric Reliability Council (SERC) Balancing Authorities (BAs). The primary objective of this project is to analyze the benefits of regional cooperation for integrating mid-western wind energy into southeast electricity markets. Scenarios were defined, modeled and investigated to address production variability and uncertainty and the associated balancing of large quantities of wind power in SPP and delivery to energy markets in the southern regions of the SERC. DOE funded Oak Ridge National Laboratory to provide additional support to the project, including a review of results and any side analysis that may provide additional insight. This report is a unit-by-unit analysis of changes in operations due to the different scenarios used in the overall study. It focuses on the change in capacity factors and the number of start-ups required for each unit since those criteria summarize key aspects of plant operations, how often are they called upon and how much do they operate. The primary analysis of the overall project is based on security-constrained unit commitment (SCUC) and economic dispatch (SCED) simulations of the SPP-SERC regions as modeled for the year 2022. The SCUC/SCED models utilized for the project were developed through extensive consultation with the project utility partners, to ensure the various regions and operational practices are represented as best as possible in the model. SPP, Entergy, Oglethorpe Power Company (OPC), Southern Company, and the Tennessee Valley Authority (TVA) actively participated in the project providing input data for the models and review of simulation results and conclusions. While other SERC utility systems are modeled, the listed SERC utilities were explicitly included as active participants in the project due to the size of their load and relative proximity to SPP for importing wind energy.

17 WIND ENERGY↗

Prediction and Experimental Verification of Electrolyte Solvation Structure from an OMol25-Trained Interatomic Potential

A molecular-level understanding of electrolyte solvation structure and ion–ion correlations is critical to developing next-generation battery chemistries. Atomistic simulation capabilities with sufficient accuracy, speed, and transferability to deliver reliable structural insights while avoiding arduous system-specific reparameterization are thus highly desirable. Machine learning interatomic potentials (MLIPs) trained on large, chemically diverse data sets are revolutionizing computational chemistry, enabling molecular dynamics simulations of battery electrolytes with near-DFT accuracy over 10,000× faster than DFT. While previous MLIP training data sets with suitable elemental coverage for electrolytes have been based on inorganic materials, the Open Molecules 2025 (OMol25) data set provides large-scale molecular DFT MLIP training data with broad elemental coverage and specifically samples tens of millions of electrolyte configurations. Here, we integrate computational modeling with experimental validation to systematically assess the ability of large-scale MLIPs pretrained on materials data or on OMol25 to accurately resolve nanoscale structural organization and ion-solvation characteristics in Na-ion battery electrolytes across diverse physicochemical conditions and compositional regimes. We find that the OMol25-trained Universal Model of Atoms (UMA-OMol) predicts experimentally measured densities and X-ray structure factors in substantially better agreement compared to state-of-the-art models trained only on inorganic materials data. Using UMA-OMol, we further analyze systematic trends in solvation structure as a function of cation identity, anion chemistry, salt concentration, and solvent topology. We observe that increasing system temperature amplifies the heterogeneity within the solvation environment, perturbing cation–solvent interactions and promoting the formation of contact ion pairs (CIPs). Moreover, subtle variations in the solvent topology of glyme-based electrolytes cause pronounced changes in ion correlations and solvation structure. The experimental agreement and microscopic insights shown here position OMol25-trained MLIPs as a practical route to predictive, high-throughput electrolyte simulations beyond the limits of classical force fields and direct DFT molecular dynamics, serving as a powerful tool for accelerating the design of next-generation Na-ion battery electrolytes and beyond.

MLIPs↗

Optimal Scheduling of an Isolated Microgrid With Battery Storage Considering Load and Renewable Generation Uncertainties

By modeling the uncertainty of spinning reserves provided by energy storage with probabilistic constraints, a new optimal scheduling mode is proposed in this paper for minimizing the operating costs of an isolated microgrid (MG) by using chance-constrained programming. The model is transformed into a readily solvable mixed integer linear programming formulation in general algebraic modeling system (GAMS) via a proposed discretized step transformation approach and finally solved by applying the CPLEX solver. By properly setting the confidence levels of the spinning reserve probability constraints, the MG operation can achieve a tradeoff between reliability and economy. The test results on the modified Oak Ridge National Laboratory Distributed Energy Control and Communication lab MG test system reveal that the proposal significantly exceeds the commonly used hybrid intelligent algorithm with much better and more stable optimization results and significantly reduced calculation times.

Li, Yang↗

Optimal Allocation of Water Resources Using a Two-Stage Stochastic Programming Method with Interval and Fuzzy Parameters

Efficient water allocation is one of the most prominent issues in water resources management. In this research, a two-stage interval-parameter stochastic fuzzy programming with type 2 membership functions was used to allocate water resources optimally to different users under uncertainty. This method can handle uncertainties expressed as probability distributions, discrete intervals, and fuzzy sets. The model considers treated wastewater as an allocable water resource in a scenario, in addition to water that is extracted from wellheads, springs, and qanats. Moreover, the loss rate of water during distribution, surplus water in the reservoir in the previous and the next period, and treated wastewater parameters have been incorporated into the model. This model was applied to a case study of water resources allocation within a multi-user and multi-reservoir context in the Zarand region of Kerman, Iran. The results indicate that reasonable solutions have been generated, in the form of interval and fuzzy information under different scenarios that could help managers provide optimal water resources allocation plans. The results also demonstrate that establishing a wastewater treatment station increases the system net benefits, surplus water in wellheads for the next period, and system reliability (level of satisfying the fuzzy goal and constraints), and decreases encountering water shortages.

58 GEOSCIENCES↗

Nuclear data uncertainty propagation and modeling uncertainty impact evaluation in neutronics core simulation

Uncertainty analysis is a critical requirement in reactor simulation as it is used to quantify the reliability of best-estimate calculation. A comprehensive uncertainty analysis should characterize all sources of uncertainties in a computationally-feasible and scientifically-defendable manner. Here we employ a well-established reduced order modeling (ROM) based uncertainty quantification methodology to propagate uncertainties throughout neutronic calculations. ROM relies on recent advances in randomized data mining techniques applied to large data streams. In our proposed implementation, the nuclear data uncertainties are first propagated from multi-group level through lattice physics calculation to generate few-group parameter uncertainties, described using a vector of mean values and a covariance matrix. Employing an ROM-based compression of the covariance matrix, the few-group uncertainties are then propagated through downstream core simulation in a computationally efficient manner. This straightforward approach, albeit efficient as compared to brute force forward and/or adjoint-based methods, often employs a number of assumptions that have been unquestioned in the literature of neutronic uncertainty analysis. This manuscript argues that these assumptions could introduce another source of uncertainty referred to as modeling uncertainties, whose magnitude needs to be quantified in tandem with nuclear data uncertainties. Thus, our primary goal is to explore the interactions between these two uncertainty sources in order to assess whether modeling uncertainties have an impact on parameter uncertainties. To explore this endeavor, the impact of a number of modeling assumptions on core attributes uncertainties is quantified. The study employs a CANDU reactor model, with Serpent and NEWT as lattice physics solvers and NESTLE-C as core simulator. The modeling assumptions investigated include those related with the uncertainty propagation method employed, e.g., deterministic vs. stochastic, the few-group energy structure employed to represent the cross-sections, the resonance treatment in lattice physics calculation, the reference values for the cross-section, and the number of samples employed to render ROM compression. Results indicate that some of the modeling assumptions could have a non-negligible impact on the core responses propagated uncertainties, highlighting the need for a more comprehensive approach to combine parameter and modeling uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Composite Overwrapped Pressure Vessels (COPV): Developing Flight Rationale for the Space Shuttle Program

Introducing composite vessels into the Space Shuttle Program represented a significant technical achievement. Each Orbiter vehicle contains 24 (nominally) Kevlar tanks for storage of pressurized helium (for propulsion) and nitrogen (for life support). The use of composite cylinders saved 752 pounds per Orbiter vehicle compared with all-metal tanks. The weight savings is significant considering each Shuttle flight can deliver 54,000 pounds of payload to the International Space Station. In the wake of the Columbia accident and the ensuing Return to Flight activities, the Space Shuttle Program, in 2005, re-examined COPV hardware certification. Incorporating COPV data that had been generated over the last 30 years and recognizing differences between initial Shuttle Program requirements and current operation, a new failure mode was identified, as composite stress rupture was deemed credible. The Orbiter Project undertook a comprehensive investigation to quantify and mitigate this risk. First, the engineering team considered and later deemed as unfeasible the option to replace existing all flight tanks. Second, operational improvements to flight procedures were instituted to reduce the flight risk and the danger to personnel. Third, an Orbiter reliability model was developed to quantify flight risk. Laser profilometry inspection of several flight COPVs identified deep (up to 20 mil) depressions on the tank interior. A comprehensive analysis was performed and it confirmed that these observed depressions were far less than the criterion which was established as necessary to lead to liner buckling. Existing fleet vessels were exonerated from this failure mechanism. Because full validation of the Orbiter Reliability Model was not possible given limited hardware resources, an Accelerated Stress Rupture Test of a flown flight vessel was performed to provide increased confidence. A Bayesian statistical approach was developed to evaluate possible test results with respect to the model credibility and thus flight rationale for continued operation of the Space Shuttle with existing flight hardware. A non-destructive evaluation (NDE) technique utilizing Raman Spectroscopy was developed to directly measure the overwrap residual stress state. Preliminary results provide optimistic results that patterns of fluctuation in fiber elastic strains over the outside vessel surface could be directly correlated with increased fiber stress ratios and thus reduced reliability.

Kezirian, Michael T.↗

Real Time Volcanic Cloud Products and Predictions for Aviation Alerts

Volcanic eruptions can inject significant amounts of sulfur dioxide (SO2) and volcanic ash into the atmosphere, posing a substantial risk to aviation safety. Ingesting near-real time and Direct Readout satellite volcanic cloud data is vital for improving reliability of volcanic ash forecasts and mitigating the effects of volcanic eruptions on aviation and the economy. NASA volcanic products from the Ozone Monitoring Insrument (OMI) aboard the Aura satellite have been incorporated into Decision Support Systems of many operational agencies. With the Aura mission approaching its 10th anniversary, there is an urgent need to replace OMI data with those from the next generation operational NASA/NOAA Suomi National Polar Partnership (SNPP) satellite. The data provided from these instruments are being incorporated into forecasting models to provide quantitative ash forecasts for air traffic management. This study demonstrates the feasibility of the volcanic near-real time and Direct Readout data products from the new Ozone Monitoring and Profiling Suite (OMPS) ultraviolet sensor onboard SNPP for monitoring and forecasting volcanic clouds. The transition of NASA data production to our operational partners is outlined. Satellite observations are used to constrain volcanic cloud simulations and improve estimates of eruption parameters, resulting in more accurate forecasts. This is demonstrated for the 2012 eruption of Copahue. Volcanic eruptions are modeled using the Goddard Earth Observing System, Version 5 (GEOS-5) and the Goddard Chemistry Aerosol and Radiation Transport (GOCART) model. A hindcast of the disruptive eruption from Iceland's Eyjafjallajokull is used to estimate aviation re-routing costs using Metron Aviation's ATM Tools.

Volcanic ash↗

Interconnection Assessment Methodology and Cost Benefit Analysis for High-Penetration PV Deployment in the Arizona Public Service System

In an effort to better understand the impacts of high penetrations of photovoltaic (PV) generators on distribution systems, Arizona Public Service and its partners completed a multi-year project to develop the tools and knowledge base needed to safely and reliably integrate high penetrations of utility- and residential-scale PV. Building upon the APS Community Power Project-Flagstaff Pilot, this project investigates the impact of PV on a representative feeder in northeast Flagstaff. To quantify and catalog the effects of the estimated 1.3 MW of PV that will be installed on the feeder (both smaller units at homes and large, centrally located systems), high-speed weather and electrical data acquisition systems and digital 'smart' meters were designed and installed to facilitate monitoring and to build and validate comprehensive, high-resolution models of the distribution system. These models are being developed to analyze the impacts of PV on distribution circuit protection systems (including coordination and anti-islanding), predict voltage regulation and phase balance issues, and develop volt/VAr control schemes. This paper continues from a paper presented at the 2014 IEEE PVSC conference that described feeder model evaluation and high penetration advanced scenario analysis, specifically feeder reconfiguration. This paper presents results from Phase 5 of the project. Specifically, the paper discusses tool automation; interconnection assessment methodology and cost benefit analysis.

14 SOLAR ENERGY↗

Future Roles of Milli-, Micro-, and Nano- Grids

Although it has slowed considerably, consumption of electricity continues to grow in developed economies. Further, there are some unknowns which might accelerate this growth, such as electrification of vehicle fleets and geothermal heat pump space and water heating. Most analysts anticipate that distributed energy resources (DER) will provide a large share of the expanded generation capacity required to meet this seemingly inexorably increasing electricity demand. Further, given the urgency of tackling the climate change problem, most of the added assets must be carbonfree renewables or nuclear, end-use efficiency improvements, or highly efficient fossil-fired technologies. In developed economies worldwide, the current power delivery paradigm has been in place for more than a century, i.e. since the emergence of polyphase AC systems around the turn of the last century. A key feature of this structure is that, in principle, universal service is delivered at a consistent level of power quality and reliability (PQR) throughout large regions. This paper describes a future possible structure for the electricity generation and delivery system that leaves the existing high voltage meshed grid paradigm in place, but involves radical reorganization of parts of the distribution network and customer sites. Managing a much more diverse dispersed system poses major challenges to the current centralized grid paradigm, particularly since many of these assets are small to tiny by macrogrid standards and they may ultimately number in the millions. They are also not ones that centralized control can rely upon to function in traditionally dependable ways, e.g. renewable generation can be highly variable and changes in output of generators are not independent. Although most involved in the industry agree that a paradigm shift is both necessary and desirable to manage the new system, the nature of the future system remains quite unclear. In the possible structure described here, the traditional grid, or macrogrid, remains similar at the high voltage meshed level. Three new entities are added more locally: community grids or milligrids that operate a segment of the existing distribution system, microgrids which are akin to current customer sites but which have automonous control, and nanogrids, such as telecom or Ethernet networks that currently distribute power to many low-power devices. The latter exist currently in the local electrical systems but are not typically considered a part of the traditional electricity supply system. Because all these new entities exhibit some localized control, providing appropriate local heterogeneous PQR becomes a possibility. These new grid concepts enable a more"bottom-up" approach to electricity distribution, in contrast to the historic 'top-down' model. The future will almost certainly include a mix of the two, but the balance among them and the interface (if any) between them is unclear.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Incentive-Based Control and Coordination of Distributed Energy Resources. Final Report

The rapid growth of low-inertia renewable energy resources represents an immense opportunity for the U.S. to minimize its carbon footprint, while presenting a challenge for system operators as traditional “spinning” generation resources are displaced. This transformation requires solutions to robustly and cost-effectively manage dynamic changes on the grid while ensuring quality of service. There is growing recognition that distributed energy resources (DERs – loads, distributed generation, storage, electric vehicles, etc.) represent a great potential to perform this function. This report details a scalable hierarchical control strategy for coordinating thousands of heterogeneous DERs in order to provide three ancillary gird services: 1) frequency response, a rapid (within 2 seconds) service used to maintain the grid at 60 Hz; 2) regulation response, a larger response used to balance on-going differences in supply and demand on the grid; and, 3) ramping reserve, used to bring on capacity to replace lost generation. The developed control architecture consists of 1) a Distribution Reliability Coordinator (DRC), 2) aggregator controllers, and finally, 3) DER controllers. The DRC coordinates all the flexible loads and distributed energy resources on the distribution system and bids the aggregate flexibility into the wholesale market. The DRC also performs resource allocation (deciding how the flexible devices on the distribution system will be dispatched) to meet the requirements for each of the three ancillary services. The aggregators control a collection of devices that are geographically co-located and provide a platform to aggregate their flexibility and mitigate uncertainty associated with a single flexible load by managing a large aggregation of similar loads (so that any stochastic effects average out). Finally, DER controllers (for example, thermostats for air conditioners, chargers for electric vehicles) adjust the power consumption of individual devices to ensure accurate and reliable delivery of the requested grid services. Evaluation and validation of this approach was conducted with a mixture of simulation and hardware testing for a range of DERs in residential (air conditioners and water heaters), commercial HVAC (ventilation fans and central chiller plants), and micro-grids (battery energy storage, solar PV etc.). This culminated in DER hardware and simulation models operating in conjunction with grid simulations as part of a large scale federated test-bed demonstration. Simulations of over 10,000 controllable residential devices (a combination of air conditioners, water heaters, batteries, and electric vehicles) demonstrated that this advanced control approach could simultaneously meet all three grid services. Furthermore, hardware-in-the-loop testing was performed with operational micro-grid and commercial building HVAC equipment. The micro-grid equipment (representing PV, battery storage, and back-up generators) demonstrated the ability to meet all frequency response requirements (except ramping time). The commercial building HVAC ventilation equipment successfully provided the regulating response service. An Industry Advisory Board (IAB) was formed and engaged throughout the project to get feed-back on project risks and potential commercialization barriers. Their input was invaluable in identify key risks stemming from regulatory and market access challenges, financial risks from under-performance, and competitive threats from utility-scale solutions such as integrated storage. A phased commercialization plan was developed that addresses continued risk reduction (value proposition refinement and performance uncertainty assessments), piloting through field demonstrations with key stakeholders, and finally, deployment as an emerging standard for DER control.

24 POWER TRANSMISSION AND DISTRIBUTION↗