A numerical homogenization method for heterogeneous, anisotropic elastic media based on multiscale theory

The development of reliable methods for upscaling fine scale models of elastic media has long been an important topic for rock physics and applied seismology. Several effective medium theories have been developed to provide elastic parameters for materials such as finely layered media or randomly oriented or aligned fractures. In such cases, the analytic solutions for upscaled properties can be used for accurate prediction of wave propagation. However, such theories cannot be applied directly to homogenize elastic media with more complex, arbitrary spatial heterogeneity. We therefore propose a numerical homogenization algorithm based on multiscale finite element methods for simulating elastic wave propagation in heterogeneous, anisotropic elastic media. Specifically, our method used multiscale basis functions obtained from a local linear elasticity problem with appropriately defined boundary conditions. Homogenized, effective medium parameters were then computed using these basis functions, and the approach applied a numerical discretization that is similar to the rotated staggered-grid finite difference scheme. Comparisons of the results from our method and from conventional, analytical approaches for finely layered media showed that the homogenization reliably estimated elastic parameters for this simple geometry. Additional tests examined anisotropic models with arbitrary spatial heterogeneity where the average size of the heterogeneities ranged from several centimeters to several meters, and the ratio between the dominant wavelength and the average size of the arbitrary heterogeneities ranged from 10 to 100. Comparisons to finite-difference simulations proved that the numerical homogenization was equally accurate for these complex cases.

58 GEOSCIENCES↗

Methods for analysing the quality of the element base of quantum information technologies

Methods for analysing the quality of the element base of quantum information technologies are considered. Methods for simulating quantum operations with allowance for quantum noise, based on the formalism of quantum operations (operator sum method and Choi – Jamiolkowski isomorphism), are described. Results of simulating some one- and two-qubit quantum transformations with allowance for the amplitude and phase relaxation and the presence of depolarising noise are reported. The quantum state tomography, based on the root approach and maximum likelihood method, is considered. The method of guaranteed estimation of quantum tomography accuracy, which implies quantitative estimation of measurement results, is described. Tomography of a single-qubit transformation on a superconducting quantum processor (IBM) is performed. The practical purpose of the study is to provide high quality and efficiency of quantum information technologies. The results obtained can be used to improve the quality of logic gates of quantum computers and debug the procedures of quantum state control in quantum cryptography problems. The bibliography includes 28 references. (quantum technology)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling Bimolecular Reactions and Transport in Porous Media Via Particle Tracking

We use a particle-tracking method to simulate several one-dimensional bimolecular reactive transport experiments. In this numerical method, the reactants are represented by particles: advection and dispersion dominate the flow, and molecular diffusion dictates, in large part, the reactions. The particle/particle reactions are determined by a combination of two probabilities dictated by the physics of transport and energetics of reaction. The first is that reactant particles occupy the same volume over a short time interval. The second is the conditional probability that two collocated particles favorably transform into a reaction. The first probability is a direct physical representation of the degree of mixing in an advancing displacement front, and as such lacks empirical parameters except for the user-defined number of particles. This number can be determined analytically from concentration autocovariance, if this type of data is available. The simulations compare favorably to two physical experiments. In one, the concentration of product, 1,2-naphthoquinoe-4-aminobenzene (NQAB) from reaction between 1,2-naphthoquinone-4-sulfonic acid (NQS) and aniline (AN), was measured at the outflow of a column filled with glass beads at different times. In the other, the concentration distribution of reactants (CuSO_4 and EDTA^{4-}) and products (CuEDTA^{4-}) were quantified by snapshots of transmitted light through a column packed with cryloite sand. The thermodynamic rate coefficient in the latter experiment was 10^7 times greater than the former experiment, making it essentially instantaneous. When compared to the solution of the advection-dispersion-reaction equation (ADRE) with the well-mixed reaction coefficient, the experiments and the particle-tracking simulations showed on the order of 20% to 40% less overall product, which is attributed to poor mixing. The poor mixing also leads to higher product concentrations on the edges of the mixing zones, which the particle model simulates more accurately than the ADRE.

54 ENVIRONMENTAL SCIENCES↗

Dynamical tuning of the chemical potential to achieve a target particle number in grand canonical Monte Carlo simulations

We present a method to facilitate Monte Carlo simulations in the grand canonical ensemble given a target mean particle number. The method imposes a fictitious dynamics on the chemical potential, to be run concurrently with the Monte Carlo sampling of the physical system. Corrections to the chemical potential are made according to time-averaged estimates of the mean and variance of the particle number, with the latter being proportional to thermodynamic compressibility. Here, we perform a variety of tests, and in all cases find rapid convergence of the chemical potential—inexactness of the tuning algorithm contributes only a minor part of the total measurement error for realistic simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnonic band structure, complete bandgap, and collective spin wave excitation in nanoscale two-dimensional magnonic crystals

We present the observation of a complete bandgap and collective spin wave excitation in two-dimensional magnonic crystals comprised of arrays of nanoscale antidots and nanodots, respectively. Considering that the frequencies dealt with here fall in the microwave band, these findings can be used for the development of suitable magnonic metamaterials and spin wave based signal processing. We also present the application of a numerical procedure, to compute the dispersion relations of spin waves for any high symmetry direction in the first Brillouin zone. The results obtained from this procedure have been reproduced and verified by the well established plane wave method for an antidot lattice, when magnetization dynamics at antidot boundaries are pinned. The micromagnetic simulation based method can also be used to obtain iso–frequency contours of spin waves. Iso–frequency contours are analogous of the Fermi surfaces and hence, they have the potential to radicalize our understanding of spin wave dynamics. The physical origin of bands, partial and full magnonic bandgaps have been explained by plotting the spatial distribution of spin wave energy spectral density. Although, unfettered by rigid assumptions and approximations, which afflict most analytical methods used in the study of spin wave dynamics, micromagnetic simulations tend to be computationally demanding. Thus, the observation of collective spin wave excitation in the case of nanodot arrays, which can obviate the need to perform simulations, may also prove to be valuable.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electronic structure and aromaticity of large-scale hexagonal graphene nanoflakes

With the help of the recently developed SIESTA-pole (Spanish Initiative for Electronic Simulations with Thousands of Atoms) - PEXSI (pole expansion and selected inversion) method [L. Lin, A. García, G. Huhs, and C. Yang, J. Phys.: Condens. Matter 26, 305503 (2014)], we perform Kohn-Sham density functional theory calculations to study the stability and electronic structure of hydrogen passivated hexagonal graphene nanoflakes (GNFs) with up to 11 700 atoms. We find the electronic properties of GNFs, including their cohesive energy, edge formation energy, highest occupied molecular orbital-lowest unoccupied molecular orbital energy gap, edge states, and aromaticity, depend sensitively on the type of edges (armchair graphene nanoflakes (ACGNFs) and zigzag graphene nanoflakes (ZZGNFs)), size and the number of electrons. We observe that, due to the edge-induced strain effect in ACGNFs, large-scale ACGNFs’ edge formation energy decreases as their size increases. This trend does not hold for ZZGNFs due to the presence of many edge states in ZZGNFs. We find that the energy gaps E{sub g} of GNFs all decay with respect to 1/L, where L is the size of the GNF, in a linear fashion. But as their size increases, ZZGNFs exhibit more localized edge states. We believe the presence of these states makes their gap decrease more rapidly. In particular, when L is larger than 6.40 nm, we find that ZZGNFs exhibit metallic characteristics. Furthermore, we find that the aromatic structures of GNFs appear to depend only on whether the system has 4N or 4N + 2 electrons, where N is an integer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-18C-04: A Combination of Monoenergetic Reconstruction and Stoichiometric Calibration for Tissue Characterization Using Dual Energy Computed Tomography

Purpose: Dual energy computed tomography (DECT) pre-reconstruction methods require the prior knowledge of the X-ray source spectrum to allow extracting physical parameters needed for radiation therapy dose calculation, such as electron density (ED) and the effective atomic number (EAN). While DECT stoichiometric calibration may provide reliable performance for typical radiation therapy clinical conditions, it is yet to be adapted to prereconstruction methods. The presence of noise and inaccurate spectrum description may lead to systematic errors and artifacts which compromise the accuracy of treatment planning. Methods: A new technique is investigated which consists in applying a DECT stoichiometric calibration method to a set of monoenergetic images obtained with a DECT prereconstruction method. To evaluate the performance of this extended method, a simulation environment is developed to generate DECT scans under well controlled conditions, to reconstruct monoenergetic images of a tissue-equivalent phantom from transformed sinograms and to extract ED and EAN maps using a DECT formalism. Result: Under simulated clinical conditions, the accuracy in determining ED with the extended method versus a pre-reconstruction method alone is shown to be better than 0.35% versus 0.5%, respectively. In the presence of a realistic noise level, EAN determination presents a relative mean error that drops from 2.5% to 0.5% once the calibration is applied. Considering a spectrum alteration by a 1 mm Cu layer, EAN errors are up to 30% for the pre-reconstruction method alone versus less than 3% for the extended method. Conclusion: This study shows that combining pre-reconstruction DECT methods with a stoichiometric calibration considerably improves the accuracy and reliability of tissue characterization for radiation therapy in a clinical context. The presented method could potentially be adapted as gold standard for dose calculation methods based on DECT.

07 ISOTOPE AND RADIATION SOURCES↗

Feasibility of RACT for 3D dose measurement and range verification in a water phantom

Purpose: The objective of this study is to establish the feasibility of using radiation-induced acoustics to measure the range and Bragg peak dose from a pulsed proton beam. Simulation studies implementing a prototype scanner design based on computed tomographic methods were performed to investigate the sensitivity to proton range and integral dose. Methods: Derived from thermodynamic wave equation, the pressure signals generated from the dose deposited from a pulsed proton beam with a 1 cm lateral beam width and a range of 16, 20, and 27 cm in water using Monte Carlo methods were simulated. The resulting dosimetric images were reconstructed implementing a 3D filtered backprojection algorithm and the pressure signals acquired from a 71-transducer array with a cylindrical geometry (30 × 40 cm) rotated over 2π about its central axis. Dependencies on the detector bandwidth and proton beam pulse width were performed, after which, different noise levels were added to the detector signals (using 1 μs pulse width and a 0.5 MHz cutoff frequency/hydrophone) to investigate the statistical and systematic errors in the proton range (at 20 cm) and Bragg peak dose (of 1 cGy). Results: The reconstructed radioacoustic computed tomographic image intensity was shown to be linearly correlated to the dose within the Bragg peak. And, based on noise dependent studies, a detector sensitivity of 38 mPa was necessary to determine the proton range to within 1.0 mm (full-width at half-maximum) (systematic error < 150 μm) for a 1 cGy Bragg peak dose, where the integral dose within the Bragg peak was measured to within 2%. For existing hydrophone detector sensitivities, a Bragg peak dose of 1.6 cGy is possible. Conclusions: This study demonstrates that computed tomographic scanner based on ionizing radiation-induced acoustics can be used to verify dose distribution and proton range with centi-Gray sensitivity. Realizing this technology into the clinic has the potential to significantly impact beam commissioning, treatment verification during particle beam therapy and image guided techniques.

07 ISOTOPE AND RADIATION SOURCES↗

Lattice Quantum Chromodynamics: SPI, mapping, site ordering, and QPX in Lattice QCD code on Mira (ALCF-2 Early Science Program Technical Report)

Lattice QCD is a numerical method to simulate QCD (Quantum Chromodynamics) including non-perturbative effects. Among other methods, lattice QCD is the only successful non-perturbative method that can be systematically improved from first principles. Lattice QCD plays an important role in High Energy Particle Physics (flavor physics, spectroscopy, and beyond the Standard Model physics) and Nuclear Physics (nucleon/nuclear spectrum & structure, quark-gluon plasma, and the QCD equation of state). Moreover, recently there are active developments in applying lattice gauge theory to quantum field theory in general, for example the theoretical description of graphene or cold atom systems. We define the QCD action on a finite and discrete ‘lattice’ like grid, so that we can compute the path integral (partition function) on a computer. A current lattice size is 96 3 ×192, and the corresponding number of degrees of freedom for the path integral is about 6×10 8 . Thus, it requires enormous computing resources. In this report, we describe our overall efforts to improve lattice QCD software on Mira, which include a new communication library using the Message Unit (MU) SPI (System Programming Interface), better node mapping strategy, lattice site reordering, and using the quad floating point (QPX) intrinsics.

Na, Heechang↗

Anisotropic Elastic-Waveform Modeling for Fracture Characterization in EGS Reservoirs

Enhanced geothermal systems (EGS) contain newly created fractures in addition to possible existing fractures. Accurate characterization and monitoring of EGS reservoirs are crucial for optimal placement of new wells and effective extraction of geothermal heat. The fractured reservoirs behave as anisotropic media where seismic waves propagate with different velocities along different directions. In addition, the anisotropic properties of fluid-filled fracture zones could be different from those of dry fracture zones. We develop an optimized rotated staggered-grid elastic-wave finite-difference method for simulating seismic-wave propagation in heterogeneous, anisotropic media. Our new method uses a few extra grid points and optimized finite-difference coefficients based on the space-time dispersion relation, and reduce numerical dispersion of the conventional rotated staggered-grid finite-difference scheme. We validate our new method using synthetic vertical-seismic-profiling (VSP) data for an anisotropic geophysical model built with geologic features found at the Raft River EGS reservoir. This improved and optimized rotated staggered-grid finite-difference method provides an essential tool for analyzing VSP data, reverse-time migration, and elastic-waveform inversion in anisotropic, fractured reservoirs.

58 GEOSCIENCES↗

Probabilistic Assessment of Structural Integrity

A probability-based approach, combining deterministic and probabilistic methods, was developed for analyzing building and component failures, which are especially crucial for complex structures like nuclear power plants. This method links finite element and probabilistic software to assess structural integrity under static and dynamic loads. This study uses NEPTUNE software, which is validated, for a deterministic transient analysis and ProFES software for probabilistic models. In a case study, deterministic analyses with varied random variables were transferred to ProFES for probabilistic analyses of piping failure and wall damage. A Monte Carlo Simulation, First-Order Reliability Method, and combined methods were employed for probabilistic analyses under severe transient loading, focusing on a postulated accident at the Ignalina Nuclear Power Plant. The study considered uncertainties in material properties, component geometry, and loads. The results showed the Monte Carlo Simulation method to be conservative for high failure probabilities but less so for low probabilities. The Response Surface/Monte Carlo Simulation method explored the impact load–failure probability relationship. Given the uncertainties in material properties and loads in complex structures, a deterministic analysis alone is insufficient. Probabilistic analysis is imperative for extreme loading events and credible structural safety evaluations.

Mathematics↗

The Laser Damage Threshold for Materials and the Relation Between Solid-Melt and Melt-Vapor Interface Velocities

Numerous experiments have demonstrated and analytic theories have predicted that there is a threshold for pulsed laser ablation of a wide range of materials. Optical surface damage threshold is a very complex and important application of high-power lasers. Optical damage may also be considered to be the initial phase of laser ablation. In this work it was determined the time required and the threshold energy of a layer of thickness to heat up. We used the Finite Difference method to simulate the process of laser-target interaction in three cases. Namely, the case before melting begins using a continuous wave (c.w) laser source and a pulsed laser source, the case after the first change of state (from solid to melt), and the case after the second change of state (from melt to vapor). And also study the relation between the solid-melt and melt-vapor interface velocities to have a commonsense of the laser ablation process.

36 MATERIALS SCIENCE↗

An optimization method of relativistic backward wave oscillator using particle simulation and genetic algorithms

Optimal design method of high-power microwave source using particle simulation and parallel genetic algorithms is presented in this paper. The output power, simulated by the fully electromagnetic particle simulation code UNIPIC, of the high-power microwave device is given as the fitness function, and the float-encoding genetic algorithms are used to optimize the high-power microwave devices. Using this method, we encode the heights of non-uniform slow wave structure in the relativistic backward wave oscillators (RBWO), and optimize the parameters on massively parallel processors. Simulation results demonstrate that we can obtain the optimal parameters of non-uniform slow wave structure in the RBWO, and the output microwave power enhances 52.6% after the device is optimized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of image detectors in radiology for determination of scatter-to-primary ratios using Monte Carlo radiation transport code MCNP/MCNPX

Purpose: The purpose of this study was to compare and validate three methods to simulate radiographic image detectors with the Monte Carlo software MCNP/MCNPX in a time efficient way. Methods: The first detector model was the standard semideterministic radiography tally, which has been used in previous image simulation studies. Next to the radiography tally two alternative stochastic detector models were developed: A perfect energy integrating detector and a detector based on the energy absorbed in the detector material. Validation of three image detector models was performed by comparing calculated scatter-to-primary ratios (SPRs) with the published and experimentally acquired SPR values. Results: For mammographic applications, SPRs computed with the radiography tally were up to 44% larger than the published results, while the SPRs computed with the perfect energy integrating detectors and the blur-free absorbed energy detector model were, on the average, 0.3% (ranging from -3% to 3%) and 0.4% (ranging from -5% to 5%) lower, respectively. For general radiography applications, the radiography tally overestimated the measured SPR by as much as 46%. The SPRs calculated with the perfect energy integrating detectors were, on the average, 4.7% (ranging from -5.3% to -4%) lower than the measured SPRs, whereas for the blur-free absorbed energy detector model, the calculated SPRs were, on the average, 1.3% (ranging from -0.1% to 2.4%) larger than the measured SPRs. Conclusions: For mammographic applications, both the perfect energy integrating detector model and the blur-free energy absorbing detector model can be used to simulate image detectors, whereas for conventional x-ray imaging using higher energies, the blur-free energy absorbing detector model is the most appropriate image detector model. The radiography tally overestimates the scattered part and should therefore not be used to simulate radiographic image detectors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of ion Coulomb crystals in a linear Paul trap

We describe a simple and fast method for simulating observed images of ion Coulomb crystals. In doing so, cold elastic collisions between Coulomb crystals and virtual very light atoms are implemented in a molecular dynamics (MD) simulation code. Such an approach reproduces the observed images of Coulomb crystals by obtaining density plots of the statistics of existence of each ion. The simple method has the advantage of short computing time in comparison with previous calculation methods. As a demonstration of the simulation, the formation of a planar Coulomb crystal with a small number of ions has been investigated in detail in a linear ion trap both experimentally and by simulation. However, also large Coulomb crystals including up to 1400 ions have been photographed and simulated to extract the secular temperature and the number of ions. For medium-sized crystals, a comparison between experiments and calculations has been performed. Moreover, an MD simulation of the sympathetic cooling of small molecular ions was performed in order to test the possibility of extracting the temperature and the number of refrigerated molecular ions from crystal images of laser-cooled ions. Such information is basic to studying ultracold ion-molecule reactions using ion Coulomb crystals including sympathetically cooled molecular ions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Simulating a pulsed-power-driven plasma with ideal MHD

We describe a simple practical numerical method for simulating plasma driven within a vacuum chamber by a pulsed power generator. Typically, in this type of simulation, the vacuum region adjacent to the plasma is approximated as a highly resistive, light fluid; this involves computationally expensive solvers describing the diffusion of the magnetic field through this fluid. Instead, we provide a recipe for coupling pulsed power generators to the magnetohydrodynamics (MHD) domain by approximating the perfectly insulating vacuum as a light, perfectly conducting, inviscid MHD fluid and discuss the applicability of this counter-intuitive technique. This much more affordable ideal MHD representation is particularly useful in situations where a plasma exhibits interesting three-dimensional phenomena, either due to the design of the experiment or due to developing instabilities. We verified that this coupling recipe works by modeling an exactly solvable flux compression generator as well as a self-similar Noh-like solution and demonstrated convergence to the theoretical solution. We also showed examples of simulating complex three-dimensional pulsed power devices with this technique. We release our code implementation to the public.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A reverse Monte Carlo method for deriving optical constants of solids from reflection electron energy-loss spectroscopy spectra

A reverse Monte Carlo (RMC) method is developed to obtain the energy loss function (ELF) and optical constants from a measured reflection electron energy-loss spectroscopy (REELS) spectrum by an iterative Monte Carlo (MC) simulation procedure. The method combines the simulated annealing method, i.e., a Markov chain Monte Carlo (MCMC) sampling of oscillator parameters, surface and bulk excitation weighting factors, and band gap energy, with a conventional MC simulation of electron interaction with solids, which acts as a single step of MCMC sampling in this RMC method. To examine the reliability of this method, we have verified that the output data of the dielectric function are essentially independent of the initial values of the trial parameters, which is a basic property of a MCMC method. The optical constants derived for SiO{sub 2} in the energy loss range of 8-90 eV are in good agreement with other available data, and relevant bulk ELFs are checked by oscillator strength-sum and perfect-screening-sum rules. Our results show that the dielectric function can be obtained by the RMC method even with a wide range of initial trial parameters. The RMC method is thus a general and effective method for determining the optical properties of solids from REELS measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Closing the Accuracy Gap in Tandem Photovoltaic Testing: An Accessible and Efficient Spectral Tuning Method Using LED-Based Simulators for Research Laboratories and Industry

Accurate performance calibration of multijunction (MJ) solar cells is critical for advancing this technology toward large-scale terrestrial application, yet existing testing methods developed by photovoltaics calibration laboratories remain prohibitively complex and resource intensive for most research laboratories. Current approaches rely on expensive multisource simulators and/or intricate spectral tuning algorithms, limiting accessibility and hindering standardized comparisons of emerging MJ technologies such as perovskite-based tandems. This paper introduces a streamlined spectral irradiance adjustment method for light-emitting diode (LED)-based solar simulators, which are increasingly adopted in the photovoltaics community due to their versatility and cost-effectiveness. The method we present bins LED channels into groups based on the number of junctions of the MJ photovoltaic device under test (DUT) and their corresponding band gaps and incorporates an automated tuning algorithm that eliminates the need to adjust each channel’s irradiance individually. This tuning algorithm requires the relative spectral responsivities of both the DUT and a broadband reference cell, as well as a calibrated spectroradiometer. Measurement validation across various MJ devices, including III-V and perovskite/silicon tandems, demonstrates excellent agreement within 1% with well-established xenon-tungsten multisource simulators and associated tuning algorithms. By enabling precise spectral tuning with readily available equipment and a simple tuning algorithm, our approach bridges the measurement accuracy gap between research laboratories and accredited testing facilities, fostering more reliable device comparisons and accelerating the translation of MJ technologies into real-world energy systems.