A closed-loop principal component analysis of a tetrahedral truss
A tetrahedral truss, representative of a fairly broad class of large space structures, is considered. A method, measuring the dynamical importance of each elastic mode when the structure is under feedback control, is presented. The main conclusion is that the closed-loop importance of each vibration mode depends on the robustness requirements. Also, there appears to be a conflict between precise control of a given node of the structure and stability margin, these two requirements leading to contradictory classifications of the modes by order of importance.