Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

The Wide-area Energy Management System Phase 2 Final Report

The higher penetration of intermittent generation resources (including wind and solar generation) in the Bonneville Power Administration (BPA) and California Independent System Operator (CAISO) balancing authorities (BAs) raises issue of requiring expensive additional fast grid balancing services in response to additional intermittency and fast up and down power ramps in the electric supply system. The overall goal of the wide-area energy management system (WAEMS) project is to develop the principles, algorithms, market integration rules, a functional design, and a technical specification for an energy storage system to help cope with unexpected rapid changes in renewable generation power output. The resulting system will store excess energy, control dispatchable load and distributed generation, and utilize inter-area exchange of the excess energy between the California ISO and Bonneville Power Administration control areas. A further goal is to provide a cost-benefit analysis and develop a business model for an investment-based practical deployment of such a system. There are two tasks in Phase 2 of the WAEMS project: the flywheel field tests and the battery evaluation. Two final reports, the Wide-area Energy Management System Phase 2 Flywheel Field Tests Final Report and the Wide-area Energy Storage and Management System Battery Storage Evaluation, were written to summarize the results of the two tasks.

25 ENERGY STORAGE↗

Development and Demonstration of an Innovative Thermal Energy Storage System for Baseload Power Generation

The objective of this project is to research and develop a thermal energy storage system (operating range 300°C - 450°C) based on encapsulated phase change materials (PCM) that can meet the utility-scale base-load concentrated solar power plant requirements at much lower system costs compared to the existing thermal energy storage (TES) concepts. The major focus of this program is to develop suitable encapsulation methods for existing low-cost phase change materials that would provide a cost effective and reliable solution for thermal energy storage to be integrated in solar thermal power plants. This project proposes a TES system concept that will allow for an increase of the capacity factor of the present CSP technologies to 75% or greater and reduce the cost to less than $20/kWht.

14 SOLAR ENERGY↗

Samba: A Detailed Memory Management Unit (MMU) for the SST Simulation Framework

The Memory Management Unit (MMU) is one of the most important parts of any modern computing system. It can be thought of as the hardware support for virtual memory, which enforces access permissions, and manages the translation of processes' virtual addresses into real memory physical addresses. The operating system (OS) allocates the physical memory in a small granularity frames that can be accessed by processes with appropriate permissions. Each process has the illusion of having an entire memory space, however, the actual addresses issued by the process, (`virtual addresses'), are translated into the physical frame address allocated by the OS through virtual memory.

97 MATHEMATICS AND COMPUTING↗

Properly Understanding the Impacts of Distributed Resources on Distribution Systems

The subject paper discusses important impacts of distributed resources on distribution networks and feeders. These include capacity, line losses, voltage regulation, and central system support (such as volt/var via central generators and substation) as the number, placement and penetration levels of distributed resources are varied. Typically, the impacts of distributed resources on the distribution system are studied by using steady-state rather than dynamic analysis tools. However, the response time and transient impacts of both system equipment (such as substation/feeder capacitors) and distributed resources needs to be taken into account and only dynamic analysis will provide the full impact results. ORNL is wrapping up a study of distributed resources interconnected to a large distribution system considering the above variables. A report of the study and its results will be condensed into a paper for this panel session. The impact of distributed resources will vary as the penetration level reaches the capacity of the distribution feeder/system. The question is how high of a penetration of distributed resource can be accommodated on the distribution feeder/system without any major changes to system operation, design and protection. The impacts most surely will vary depending upon load composition, distribution and level. Also, it is expected that various placement of distributed resources will impact the distribution system differently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model predictive control for voltage restoration in microgrids using temporal logic specifications

Power system operation will encounter numerous voltage variabilities as the proliferation of renewable energy continues. Real-time monitoring and communication technologies can potentially improve voltage stability by enabling the rapid detection of voltage deviations and the implementation of corrective actions. These corrective actions will only be effective in restoring stability if they are chosen in a timely and scalable manner. This paper considers the problem of power systems’ load voltage control in order to simultaneously address both magnitude and time voltage specifications. In order to comply with grid codes and avoid unnecessary relay protection actions, a model predictive control (MPC)-based control strategy employing temporal logic specifications (TLSs) is proposed. The TLSs strategy is introduced as a formalism to control the voltage variation at a critical load bus against operational bounds over time. The control objective is to schedule optimal control input signals from the available supportive energy storage systems, which provide reactive power injections, leading to satisfying the specified finite-time restoration described by the TLSs with minimal control efforts. The simulation results display that the TLSs strategy for power systems’ voltage control synthesis is extremely significant.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Liquid fuel molten salt reactors for thorium utilization

Molten salt reactors (MSRs) represent a class of reactors that use liquid salt, usually fluoride- or chloride-based, as either a coolant with a solid fuel (such as fluoride salt-cooled high temperature reactors) or as a combined coolant and fuel with fuel dissolved in a carrier salt. For liquid-fuelled MSRs, the salt can be processed online or in a batch mode to allow for removal of fission products as well as introduction of fissile fuel and fertile materials during reactor operation. The MSR is most commonly associated with the 233 U/thorium fuel cycle, as the nuclear properties of 233 U combined with the online removal of parasitic absorbers allow for the ability to design a thermal-spectrum breeder reactor; however, MSR concepts have been developed using all neutron energy spectra (thermal, intermediate, fast, and mixed-spectrum zoned concepts) and with a variety of fuels including uranium, thorium, plutonium, and minor actinides. Early MSR work was supported by a significant research and development (R&D) program that resulted in two experimental systems operating at ORNL in the 1960s, the Aircraft Reactor Experiment and the Molten Salt Reactor Experiment. Subsequent design studies in the 1970s focusing on thermal-spectrum thorium-fueled systems established reference concepts for two major design variants: (1) a molten salt breeder reactor (MSBR), with multiple configurations that could breed additional fissile material or maintain self-sustaining operation; and (2) a denatured molten salt reactor (DMSR) with enhanced proliferation-resistance. T MSRs has been selected as one of six most promising Generation IV systems and development activities have been seen in fast-spectrum MSRs, waste-burning MSRs, MSRs fueled with low-enriched uranium (LEU), as well as more traditional thorium fuel cycle-based MSRs. This study provides an historical background of MSR R&D efforts, surveys and summarizes many of the recent development, and provides analysis comparing thorium-based MSRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Using hydrogen and ammonia for renewable energy storage: A geographically comprehensive techno-economic study

Hydrogen and, more recently, ammonia have received worldwide attention as energy storage media. In this work we investigate the economics of using each of these chemicals as well as the two in combination for islanded renewable energy supply systems in 15 American cities representing different climate regions throughout the country. We use an optimal combined capacity planning and scheduling model which minimizes the levelized cost of energy (LCOE) by determining optimal unit selection and size along with unit commitments, production rates, and storage inventories for each period of system operation. These periods are aggregated from full year hourly resolution data via a consecutive temporal clustering algorithm. Ammonia is generally more economical than hydrogen as a single method of energy storage. Additionally, systems which use both hydrogen and ammonia outperform those which use only one storage option and have LCOE between $\$ 0.17$/kWh and $\$ 0.28$/kWh, including full investment in renewable generation infrastructure.

25 ENERGY STORAGE↗

Detecting False Data Injection Attacks in Smart Grids: A Semi-Supervised Deep Learning Approach

The dependence on advanced information and communication technology increases the vulnerability in smart grids under cyber-attacks. Recent research on unobservable false data injection attacks (FDIAs) reveals the high risk of secure system operation, since these attacks can bypass current bad data detection mechanisms. To mitigate this risk, this paper proposes a data-driven learning-based algorithm for detecting unobservable FDIAs in distribution systems. We use autoencoders for efficient dimension reduction and feature extraction of measurement datasets. Further, we integrate the autoencoders into an advanced generative adversarial network (GAN) framework, which successfully detects anomalies under FDIAs by capturing the unconformity between abnormal and secure measurements. Also, considering that the datasets collected from practical power systems are partially labeled due to expensive labeling costs and missing labels, the proposed method only requires a few labeled measurement data in addition to unlabeled data for training. Numerical simulations in three-phase unbalanced IEEE 13-bus and 123-bus distribution systems validate the detection accuracy and efficiency of this method.

97 MATHEMATICS AND COMPUTING↗

Impact of simultaneous activities on frequency fluctuations — comprehensive analyses based on the real measurement data from FNET/GridEye

Simultaneous human activities such as the Super Bowl game would cause certain impacts on frequency fluctuations in power systems. With the help of FNET/GridEye measurements, this work aims to give comprehensive analyses on the frequency fluctuations during Super Bowl LIV held on Feb. 2, 2020, so as to better understand several phenomena caused by simultaneous activities and help system operation and control. First, recent developments of FNET/GridEye are introduced briefly. Second, the frequency fluctuations of Eastern Interconnection (EI), western electricity coordinating council (WECC), and electric reliability council of Texas (ERCOT) power systems during Super Bowl LIV are analyzed. Third, frequency fluctuations of Super Bowl Sunday and ordinary Sundays in 2020 are compared. Finally, the differences of frequency fluctuations among different years during the Super Bowl and their change trend are also given. Furthermore, several possible explanations including the simultaneity of electricity consumption at the beginning of commercial breaks and the halftime show, the increasing usage of the Internet, and the increasing size of TV screens are illustrated in detail in this work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Observations on the Optimality Tolerance in the CAISO 33% RPS Model

In 2008 Governor Schwarzenegger of California issued an executive order requiring that 33 percent of all electricity in the state in the year 2020 should come from renewable resources such as wind, solar, geothermal, biomass, and small hydroelectric facilities. This 33% renewable portfolio standard (RPS) was further codified and signed into law by Governor Brown in 2011. To assess the market impacts of such a requirement, the California Public Utilities Commission (CPUC) initiated a study to quantify the cost, risk, and timing of achieving a 33% RPS by 2020. The California Independent System Operator (CAISO) was contracted to manage this study. The production simulation model used in this study was developed using the PLEXOS software package, which allows energy planners to optimize long-term system planning decisions under a wide variety of system constraints. In this note we describe our observations on varying the optimality tolerance in the CAISO 33% RPS model. In particular, we observe that changing the optimality tolerance from .05% to .5% leads to solutions over 5 times faster, on average, producing very similar solutions with a negligible difference in overall distance from optimality.

09 BIOMASS FUELS↗

Southern company energy storage study :

This study evaluates the business case for additional bulk electric energy storage in the Southern Company service territory for the year 2020. The model was used to examine how system operations are likely to change as additional storage is added. The storage resources were allowed to provide energy time shift, regulation reserve, and spinning reserve services. Several storage facilities, including pumped hydroelectric systems, flywheels, and bulk-scale batteries, were considered. These scenarios were tested against a range of sensitivities: three different natural gas price assumptions, a 15% decrease in coal-fired generation capacity, and a high renewable penetration (10% of total generation from wind energy). Only in the elevated natural gas price sensitivities did some of the additional bulk-scale storage projects appear justifiable on the basis of projected production cost savings. Enabling existing peak shaving hydroelectric plants to provide regulation and spinning reserve, however, is likely to provide savings that justify the project cost even at anticipated natural gas price levels. Transmission and distribution applications of storage were not examined in this study. Allowing new storage facilities to serve both bulk grid and transmission/distribution-level needs may provide for increased benefit streams, and thus make a stronger business case for additional storage.

Ellison, James↗

ZFS on RBODs - Leveraging RAID Controllers for Metrics and Enclosure Management

Traditionally, the Lustre file system has relied on the ldiskfs file system with reliable RAID (Redundant Array of Independent Disks) storage underneath. As of Lustre 2.4, ZFS was added as a backend file system, with built-in software RAID, thereby removing the need of expensive RAID controllers. ZFS was designed to work with JBOD (Just a Bunch Of Disks) storage enclosures under the Solaris Operating System, which provided a rich device management system. Long time users of the Lustre file system have relied on the RAID controllers to provide metrics and enclosure monitoring and management services, with rich APIs and command line interfaces. This paper will study a hybrid approach using an advanced full featured RAID enclosure which is presented to the host as a JBOD, This RBOD (RAIDed Bunch Of Disks) allows ZFS to do the RAID protection and error correction, while the RAID controller handles management of the disks and monitors the enclosure. It was hoped that the value of the RAID controller features would offset the additional cost, and that performance would not suffer in this mode. The test results revealed that the hybrid RBOD approach did suffer reduced performance.

97 MATHEMATICS AND COMPUTING↗

Object detection with a multistatic array using singular value decomposition

A method and system for detecting the presence of subsurface objects within a medium is provided. In some embodiments, the detection system operates in a multistatic mode to collect radar return signals generated by an array of transceiver antenna pairs that is positioned across a surface and that travels down the surface. The detection system converts the return signals from a time domain to a frequency domain, resulting in frequency return signals. The detection system then performs a singular value decomposition for each frequency to identify singular values for each frequency. The detection system then detects the presence of a subsurface object based on a comparison of the identified singular values to expected singular values when no subsurface object is present.

47 OTHER INSTRUMENTATION↗

DEVELOPMENT, INSTALLATION AND OPERATION OF THE MPC&A OPERATIONS MONITORING (MOM) SYSTEM AT THE JOINT INSTITUTE FOR NUCLEAR RESEARCH (JINR) DUBNA, RUSSIA

The Material Protection, Control and Accounting (MPC&A) Operations Monitoring (MOM) systems handling at the International Intergovernmental Organization - Joint Institute for Nuclear Research (JINR) is described in this paper. Category I nuclear material (plutonium and uranium) is used in JINR research reactors, facilities and for scientific and research activities. A monitoring system (MOM) was installed at JINR in April 2003. The system design was based on a vulnerability analysis, which took into account the specifics of the Institute. The design and installation of the MOM system was a collaborative effort between JINR, Brookhaven National Laboratory (BNL) and the U.S. Department of Energy (DOE). Financial support was provided by DOE through BNL. The installed MOM system provides facility management with additional assurance that operations involving nuclear material (NM) are correctly followed by the facility personnel. The MOM system also provides additional confidence that the MPC&A systems continue to perform effectively.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Impacts on California of Expanded Regional Cooperation to Operate the Western Grid (Final Report)

Policy makers in California and other western states are exploring options for greater regional cooperation in managing the western power grid to better achieve public policy goals. This report, requested by the California State Assembly and commissioned by the California Independent System Operator (CAISO), reviews and summarizes recent proposals, studies, and papers addressing various modes of regional cooperation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal subhourly electricity resource dispatch under multiple price signals with high renewable generation availability

This article proposes a system-wide optimal resource dispatch strategy that enables a shift from a primarily energy cost-based approach, to a strategy using simultaneous price signals for energy, power and ramping behavior. A formal method to compute the optimal sub-hourly power trajectory is derived for a system when the price of energy and ramping are both significant. Optimal control functions are obtained in both time and frequency domains, and a discrete-time solution suitable for periodic feedback control systems is presented. The method is applied to North America Western Interconnection for the planning year 2024, and it is shown that an optimal dispatch strategy that simultaneously considers both the cost of energy and the cost of ramping leads to significant cost savings in systems with high levels of renewable generation: the savings exceed 25% of the total system operating cost for a 50% renewables scenario.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Review of Visualization Methods for Cyber-Physical Security: Smart Grid Case Study

Cyber-Physical Systems (CPSs) are becoming increasingly complex and interconnected as they attempt to meet the demands of evolving society. As a result, monitoring and maintaining them becomes a more complex and demanding task for control system operators and cyber defenders. While the literature on visualization techniques in the context of cybersecurity is extensive, the same cannot be said for studies on visualization for the security of cyber-physical systems. This paper aims to fill that gap by: 1) defining the main features of a visualizations workflow for security visualizations in cyber-physical systems. The workflow includes the acquisition of cyber and physical data, processing of data, selection, and configuration of both visualization tools and end-user interactions. 2) Providing an overview of cyber-physical security visualization systems, with a focus on smart grids as a case study. Finally, we use the perspectives gained from this analysis to provide insights and directions for future research and design of cyber-physical visualization techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Net Load Redistribution Attacks on Nodal Voltage Magnitude Estimation in AC Distribution Networks

A high penetration level of smart devices and communication networks increases the threat of cyber-attacks in the distribution system. In this paper, we model a hidden, coordinated, net load redistribution attack (NLRA) in an AC distribution system. Based on local information of an attack region, the attacker’s goal is to create violations in nodal voltage magnitude estimation. Acting as a system operator equipped with global AC state estimation and bad data detection, we validate the stealthiness of the hidden NLRA in multiple attack cases. Simulation results on a modified PG&E 69-node distribution system show the validity of the proposed NLRA. The influence of NLRA on the distribution system is assessed and the impact of attack regions, attack timing, and system observability is also revealed.

Zhang, Hang↗