Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Fire Detection Tradeoffs as a Function of Vehicle Parameters

Fire survivability depends on the detection of and response to a fire before it has produced an unacceptable environment in the vehicle. This detection time is the result of interplay between the fire burning and growth rates; the vehicle size; the detection system design; the transport time to the detector (controlled by the level of mixing in the vehicle); and the rate at which the life support system filters the atmosphere, potentially removing the detected species or particles. Given the large differences in critical vehicle parameters (volume, mixing rate and filtration rate) the detection approach that works for a large vehicle (e.g. the ISS) may not be the best choice for a smaller crew capsule. This paper examines the impact of vehicle size and environmental control and life support system parameters on the detectability of fires in comparison to the hazard they present. A lumped element model was developed that considers smoke, heat, and toxic product release rates in comparison to mixing and filtration rates in the vehicle. Recent work has quantified the production rate of smoke and several hazardous species from overheated spacecraft polymers. These results are used as the input data set in the lumped element model in combination with the transport behavior of major toxic products released by overheating spacecraft materials to evaluate the necessary alarm thresholds to enable appropriate response to the fire hazard.

microgravity↗

Apparatus Characterizes Transient Voltages in Real Time

The figure shows a prototype of a relatively inexpensive electronic monitoring apparatus that measures and records selected parameters of lightning-induced transient voltages on communication and power cables. The selected parameters, listed below, are those most relevant to the ability of lightning-induced transients to damage electronic equipment. This apparatus bridges a gap between some traditional transient-voltage recorders that record complete waveforms and other traditional transient-voltage recorders that record only peak values: By recording the most relevant parameters and only those parameters this apparatus yields more useful information than does a traditional peak-value (only) recorder while imposing much smaller data-storage and data-transmission burdens than does a traditional complete-waveform recorder. Also, relative to a complete-waveform recorder, this apparatus is more reliable and can be built at lower cost because it contains fewer electronic components. The transients generated by sources other than lightning tend to have frequency components well below 1 MHz. Most commercial transient recorders can detect and record such transients, but cannot respond rapidly enough for recording lightning-induced transient voltage peaks, which can rise from 10 to 90 percent of maximum amplitude in a fraction of a microsecond. Moreover, commercial transient recorders cannot rearm themselves rapidly enough to respond to the multiple transients that occur within milliseconds of each other on some lightning strikes. One transient recorder, designed for Kennedy Space Center earlier [ Fast Transient-Voltage Recorder (KSC- 11991), NASA Tech Briefs, Vol. 23, No. 10, page 6a (October 1999)], is capable of sampling transient voltages at peak values up to 50 V in four channels at a rate of 20 MHz. That recorder contains a trigger circuit that continuously compares the amplitudes of the signals on four channels to a preset triggering threshold. When a trigger signal is received, a volatile memory is filled with data for a total time of 200 ms. After the data are transferred to nonvolatile memory, the recorder rearms itself within 400 ms to enable recording of subsequent transients. Unfortunately, the recorded data must be retrieved through a serial communication link. Depending on the amount of data recorded, the memory can be filled before retrieval is completed. Although large amounts of data are recorded and retrieved, only a small part of the information (the selected parameters) is usually required. The present transient-voltage recorder provides the required information, without incurring the overhead associated with the recording, storage, and retrieval of complete transient-waveform data. In operation, this apparatus processes transient voltage waveforms in real time to extract and record the selected parameters. An analog-to-digital converter that operates at a speed of as much as 100 mega-samples per second is used to sample a transient waveform. A real-time comparator and peak detector are implemented by use of fast field-programmable gate arrays.

Medelius, Pedro↗

Search for Wγ resonances in proton-proton collisions at √s=13 TeV using hadronic decays of Lorentz-boosted W bosons

A search for W$\gamma$ resonances in the mass range between 0.7 and 6.0 TeV is presented. The W boson is reconstructed via its hadronic decays, with the final-state products forming a single large-radius jet, owing to a high Lorentz boost of the W boson. The search is based on proton-proton collision data at $\sqrt{s} = $ 13 TeV, corresponding to an integrated luminosity of 137 fb$^{-1}$, collected with the CMS detector at the LHC in 2016-2018. The W$\gamma$ mass spectrum is parameterized with a smoothly falling background function and examined for the presence of resonance-like signals. No significant excess above the predicted background is observed. Model-specific upper limits at 95% confidence level on the product of the cross section and branching fraction to the W$\gamma$ channel are set. Limits for narrow resonances and for resonances with an intrinsic width equal to 5% of their mass, for spin-0 and spin-1 hypotheses, range between 0.17 fb at 6.0 TeV and 55 fb at 0.7 TeV. These are the most restrictive limits to date on the existence of such resonances. In specific narrow-resonance benchmark models, heavy scalar (vector) triplet resonances with masses between 0.75 (1.15) and 1.40 (1.36) TeV are excluded for a range of model parameters. Model-independent limits on the product of the cross section, signal acceptance, and branching fraction to the W$\gamma$ channel are set for minimum W$\gamma$ mass thresholds between 1.5 and 8.0 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental Validation of the Methodology for Partial Defect Verification of the Pressurized Water Reactor Spent Fuel Assemblies

A set of controlled experiments and Monte Carlo simulation studies with actual commercial pressurized water reactor (PWR) spent fuel assemblies were performed in order to validate an earlier proposal for partial defect testing of the PWR spent fuel assemblies. The proposed methodology involved insertion of tiny neutron and gamma detectors into the guide tubes of PWR assemblies, measurements and data evaluation. One of the key features of the data evaluation method was the concept of the base signature obtained by normalizing the ratio of gamma to neutron signals at each measurement position. As the base signature is relatively invariant to the characteristic variations of spent fuel assemblies such as initial fuel enrichment, cooling time, and burn-up, the methodology could be a powerful verification method which does not require operator declared information on the spent fuel. The benchmarking experiments indeed demonstrated that the methodology can be used for partial defect verification of the PWR spent fuel assemblies without operator declared data. The results from the experiments were compared with the simulations and the agreement between the two was well within ten percent. Thus, based on the simulation studies and benchmarking measurements, the methodology developed promises to be a powerful and practical way to detect partial defects that constitute 10% or more of the total active fuel pins. This far exceeds the detection threshold of 50% missing pins from a spent fuel assembly, a threshold defined by the IAEA Safeguards Criteria.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Tracking Efficiency And Charge Sharing of 3D Silicon Sensors at Different Angles in a 1.4T Magnetic Field

A 3D silicon sensor fabricated at Stanford with electrodes penetrating throughout the entire silicon wafer and with active edges was tested in a 1.4 T magnetic field with a 180 GeV/c pion beam at the CERN SPS in May 2009. The device under test was bump-bonded to the ATLAS pixel FE-I3 readout electronics chip. Three readout electrodes were used to cover the 400 {micro}m long pixel side, this resulting in a p-n inter-electrode distance of {approx} 71 {micro}m. Its behavior was confronted with a planar sensor of the type presently installed in the ATLAS inner tracker. Time over threshold, charge sharing and tracking efficiency data were collected at zero and 15{sup o} angles with and without magnetic field. The latest is the angular configuration expected for the modules of the Insertable B-Layer (IBL) currently under study for the LHC phase 1 upgrade expected in 2014.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation characteristics of the EJ-299-02H scintillator

Here a study of the dead layer thickness and quenching factor of a plastic scintillator for use in ultracold neutron (UCN) experiments is described. Alpha spectroscopy was used to determine the thickness of a thin surface dead layer to be 630 ± 110 nm. The relative light outputs from the decay of 241 Am and Compton scattering of electrons were used to extract Birks’ law coefficient, yielding a kB value of 0.087 ± 0.003 mm/MeV, consistent with some previous reports for other polystyrene-based scintillators. The results from these measurements are incorporated into the simulation to show that an energy threshold of (∼9 keV) can be achieved for the UCNProBe experiment. This low threshold enables high beta particle detection efficiency and the indirect measurement of UCN. The ability to make the scintillator deuterated, accompanied by its relatively thin dead layer, gives rise to unique applications in a wide range of UCN experiments, where it can be used to trap UCN and detect charged particles in situ.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A buffer-free concept bubble chamber for PICO dark matter searches

Here, we report on the successful operation at Drexel University of the PICO collaboration's first C 3 F 8 buffer-free prototype fluorocarbon bubble chamber. Previous PICO bubble chambers have produced world-leading WIMP search results with fluorocarbon target fluids, separated from the steel bellows by a buffer layer of water. Surface tension effects at the jar walls and liquid-liquid interface lead to a class of background events which have nuclear-recoil-like acoustic signatures and thus contaminate the WIMP-like signal region in analysis. Thus new bubble chambers are to be constructed “right-side-up”, meaning that the jar of C 3 F 8 is above the bellows with no water inside the inner vessel. The Drexel Bubble Chamber (DBC), runs successfully at and below the nuclear recoil thresholds used by PICO for WIMP searches, including thresholds as low as 1.19 keV . We have demonstrated sensitivity to 137 Cs gammas and spontaneous fission neutrons from 244 Cm, and acoustic alpha discrimination is demonstrated to be possible although the observed rate of alpha decays is very low. Position reconstruction from stereoscopic imaging allows for basic analysis cuts for calibration data. The successful construction and operation of this prototype confirm the effectiveness of the right-side-up design, which will be used in future dark matter searches such as PICO-40L and PICO-500.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging photoelectron circular dichroism of chiral molecules by femtosecond multiphoton coincidence detection

Here, we provide a detailed account of novel experiments employing electron-ion coincidence imaging to discriminate chiral molecules. The full three-dimensional angular scattering distribution of electrons is measured after photoexcitation with either left or right circular polarized light. The experiment is performed using a simplified photoelectron-photoion coincidence imaging setup employing only a single particle imaging detector. Results are reported applying this technique to enantiomers of the chiral molecule camphor after three-photon ionization by circularly polarized femtosecond laser pulses at 400 nm and 380 nm. The electron-ion coincidence imaging provides the photoelectron spectrum of mass-selected ions that are observed in the time-of-flight mass spectra. The coincident photoelectron spectra of the parent camphor ion and the various fragment ions are the same, so it can be concluded that fragmentation of camphor happens after ionization. We discuss the forward-backward asymmetry in the photoelectron angular distribution which is expressed in Legendre polynomials with moments up to order six. Furthermore, we present a method, similar to one-photon electron circular dichroism, to quantify the strength of the chiral electron asymmetry in a single parameter. The circular dichroism in the photoelectron angular distribution of camphor is measured to be 8% at 400 nm. The electron circular dichroism using femtosecond multiphoton excitation is of opposite sign and about 60% larger than the electron dichroism observed before in near-threshold one-photon ionization with synchrotron excitation. We interpret our multiphoton ionization as being resonant at the two-photon level with the 3s and 3p Rydberg states of camphor. Theoretical calculations are presented that model the photoelectron angular distribution from a prealigned camphor molecule using density functional theory and continuum multiple scattering X alpha photoelectron scattering calculations. Qualitative agreement is observed between the experimental results and the theoretical calculations of the Legendre moments representing the angular distribution for the two enantiomers. The electron-ion coincidence technique using multiphoton ionization opens new directions in table-top analytical mass-spectrometric applications of mixtures of chiral molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A method to observe field-region oxide charge and inter-electrode isolation from CV-characteristics of n-on-p devices

Abstract N-on-psilicon sensors will be utilized in the Compact Muon Solenoid (CMS) detector's tracker and High Granularity Calorimeter (HGCAL) in the High Luminosity upgrade of the Large Hadron Collider (HL-LHC). Among their several advantages in terms of radiation hardness over the traditionalp-on-nsensors in the extreme radiation environment of the HL-LHC are electron collection instead of holes and overlapping maxima of weighting and electric fields at the charge-collecting electrodes. The disadvantage of the multi-channel SiO 2 -passivatedn-on-psensors is the generation of an inversion layer under the Si/SiO 2 -interface by a positive interface-oxide-charge (N ox ) that at high densities can compromise the position resolution by creating a conduction channel between the electrodes. This issue is typically addressed by including additional isolnts (p-stp,p-spray) between n + -electrodes. Focusing on the guard-ring regions ofn-on-psensors where no isolation implants are applied between the electrodes, a capacitance-voltage (CV) characterization study of both 6-inch wafer test diodes and 8-inch HGCAL prototype and pre-series sensors showed a distinct threshold voltage (V th,iso ) in theCV-characteristics of a biased n + -electrode when its enclosing guard-ring was left floating. When reproduced by simulations, the measuredV th,iso was found to contain information on the field-regionN ox and indicate the threshold where the two electrodes become electrically isolated by the influence of the reverse bias voltage. Together with previous studies on the inter-electrode isolation of irradiatedn-on-psensors, the results indicate that position sensitiven-on-psensors without isolation implants may be feasible in future HEP experiments.

Instruments & Instrumentation↗

CMB-HD: An Ultra-Deep, High-Resolution Millimeter-Wave Survey Over Half the Sky

A millimeter-wave survey over half the sky, that spans frequencies in the range of 30 to 350 GHz, and that is both an order of magnitude deeper and of higher-resolution than currently funded surveys would yield an enormous gain in understanding of both fundamental physics and astrophysics. By providing such a deep, high-resolution millimeter-wave survey (about 0.5 Karcmin noise and 15 arcsecond resolution at 150 GHz), CMB-HD will enable major advances.It will allow 1.) the use of gravitational lensing of the primordial microwave background to map the distribution of matter on small scales (k 10 hMpc1), which probes dark matter particle properties. It will also allow 2.) measurements of the thermal and kinetic Sunyaev-Zel'dovich effects on small scales to map the gas density and gas pressure profiles of halos over a wide field,which probes galaxy evolution and cluster astrophysics. In addition, CMB-HD would allow us to cross critical thresholds in fundamental physics: 3.) ruling out or detecting any new, light (< 0:1 eV), thermal particles, which could potentially be the dark matter, and 4.) testing a wide class of multi-field models that could explain an epoch of inflation in the early Universe. Such a survey would also 5.) monitor the transient sky by mapping the full observing region every few days,which opens a new window on gamma-ray bursts, novae, fast radio bursts, and variable active galactic nuclei. Moreover, CMB-HD would 6.) provide a census of planets, dwarf planets, andasteroids in the outer Solar System, and 7.) enable the detection of exo-Oort clouds around othersolar systems, shedding light on planet formation. The combination of CMB-HD with contemporaryground and space-based experiments will also provide powerful synergies. CMB-HD willdeliver this survey in 5 years of observing 20,000 square degrees, using two new 30-meter-classoff-axis cross-Dragone telescopes to be located at Cerro Toco in the Atacama Desert. The telescopeswill field about 2.4 million detectors (600,000 pixels) in total. The CMB-HD survey willbe made publicly available, with usability and accessibility a priority.

Sehgal, Neelima↗

Compressed-sensing-based content-driven hierarchical reconstruction: Theory and application to C-arm cone-beam tomography

Purpose: This paper addresses the reconstruction of x-ray cone-beam computed tomography (CBCT) for interventional C-arm systems. Subsampling of CBCT is a significant issue with C-arms due to their slow rotation and to the low frame rate of their flat panel x-ray detectors. The aim of this work is to propose a novel method able to handle the subsampling artifacts generally observed with analytical reconstruction, through a content-driven hierarchical reconstruction based on compressed sensing. Methods: The central idea is to proceed with a hierarchical method where the most salient features (high intensities or gradients) are reconstructed first to reduce the artifacts these features induce. These artifacts are addressed first because their presence contaminates less salient features. Several hierarchical schemes aiming at streak artifacts reduction are introduced for C-arm CBCT: the empirical orthogonal matching pursuit approach with the ℓ{sub 0} pseudonorm for reconstructing sparse vessels; a convex variant using homotopy with the ℓ{sub 1}-norm constraint of compressed sensing, for reconstructing sparse vessels over a nonsparse background; homotopy with total variation (TV); and a novel empirical extension to nonlinear diffusion (NLD). Such principles are implemented with penalized iterative filtered backprojection algorithms. For soft-tissue imaging, the authors compare the use of TV and NLD filters as sparsity constraints, both optimized with the alternating direction method of multipliers, using a threshold for TV and a nonlinear weighting for NLD. Results: The authors show on simulated data that their approach provides fast convergence to good approximations of the solution of the TV-constrained minimization problem introduced by the compressed sensing theory. Using C-arm CBCT clinical data, the authors show that both TV and NLD can deliver improved image quality by reducing streaks. Conclusions: A flexible compressed-sensing-based algorithmic approach is proposed that is able to accommodate for a wide range of constraints. It is successfully applied to C-arm CBCT images that may not be so well approximated by piecewise constant functions.

60 APPLIED LIFE SCIENCES↗

Correction for nonlinear photon counting effects in lidar systems

Photomultiplier tubes (PMT's) employed in the photon counting (PC) mode of operation are widely used as detectors in lidar systems. In our laboratory, we have developed a versatile Nd:YAG lidar which is used for measurement of both the middle atmosphere and the troposphere. With this system, we encounter a very wide range of signal levels ranging from the extremely weak signals from the top of the mesosphere to the very strong returns from low level clouds. Although the system is capable of operating the PMT's in either the analog detection or photon counting mode, we find that often when we use photon counting we have portions of our lidar return which contain very useful information but are not within the linear operating regime of the PC system. We report the results of our efforts to explore the extent to which such high intensity PC signals can be quantitatively analyzed. In particular, a useful model relating the mean 'true' count rate and the observed count rate is presented and it's application to our system demonstrated. This model takes into account the variation in height of the PMT output pulses and the effect of the pulse height discrimination threshold.

Donovan, D. P.↗

Performance Before and After Irradiation of Pixelated 3D Silicon Sensors for the HL-LHC CMS Tracker

The Large Hadron Collider (LHC) particle accelerator at European Center for Nuclear Research (CERN) will be shut down starting in 2026 to achieve the High Luminosity Large Hadron Collider (HL-LHC) upgrade. The upgrade will allow for higher fluences, in order to increase the probability of detecting increasingly rare particles, and to obtain higher precision measurements of known particles. To accommodate the new accelerator conditions, many aspects of the Compact Muon Solenoid (CMS) detector will be upgraded; of particular interest for this thesis are the silicon pixel detectors located in the inner tracker. These will be replaced and upgraded to accommodate the higher fluences of the HL-LHC upgrade, as well as to replace existing sensors which have sustained radiation damage. In order for the new sensors to operate under high luminosity conditions, they must be increasingly radiation hard, and in order to detect rare particles, they must be increasingly more precise. The performance of one Centro Nacional de Microelectronica (CNM) 3D silicon sensor before and after undergoing irradiation at fluences similar to those which will be observed at the HL-LHC was investigated to determine radiation hardness and precision. Data was collected at Fermi National Laboratory (Fermilab), in the Fermi National Laboratory Test Beam Facility (FTBF) silicon tracker telescope, which can be used to determine the number of particles, and tracks made by high energy protons passing through. The sensor was also irradiated at Fermilab in the Irradiation Test Area (ITA). Prior to data collection a tuning procedure is carried out to determine ideal bias voltage operating conditions, mask noisy and dead pixels, adjust to the ideal threshold, and map sensor gain. Data is then collected at the FTBF, where the sensor is installed in the center of the FTBF silicon telescope. Variables, including angle and bias voltage, are varied throughout data collection. Data is then processed using an alignment software to determine the exact telescope geometry, along with the tracks which were observed passing through the sensor and telescope. Sensor performance was found to be comparable before and after irradiation, with irradiated results showing slightly lower efficiencies and cluster sizes. Position resolution is comparable both before and after irradiation, and similar distributions of cluster shape are observed. After irradiation, the sensor shows increasing collected charge with bias, an indication of increased width of the depletion region. Peak charge pre-irradiation is higher than post-irradiation peak charge, indicating the irradiated results are not taken under fully-depleted conditions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for lepton flavour violating decays of heavy resonances and quantum black holes to an eμ pair in proton-proton collisions at √s = 8 TeV

A search for narrow resonances decaying to an electron and a muon is presented. The $\mathrm {e}$ ${\mu }$ mass spectrum is also investigated for non-resonant contributions from the production of quantum black holes (QBHs). The analysis is performed using data corresponding to an integrated luminosity of 19.7 $~\text {fb}^\text {-1}$ collected in proton-proton collisions at a centre-of-mass energy of 8 $~\text {TeV}$ with the CMS detector at the LHC. With no evidence for physics beyond the standard model in the invariant mass spectrum of selected $\mathrm {e}\mu $ pairs, upper limits are set at 95 $\%$ confidence level on the product of cross section and branching fraction for signals arising in theories with charged lepton flavour violation. In the search for narrow resonances, the resonant production of a $\mathrm {\tau }$ sneutrino in R-parity violating supersymmetry is considered. The $\mathrm {\tau }$ sneutrino is excluded for masses below 1.28 $~\text {TeV}$ for couplings $\lambda _{132}=\lambda _{231}=\lambda '_{311}=0.01$ , and below 2.30 $~\text {TeV}$ for $\lambda _{132}=\lambda _{231}=0.07$ and $\lambda '_{311}=0.11$ . These are the most stringent limits to date from direct searches at high-energy colliders. In addition, the resonance searches are interpreted in terms of a model with heavy partners of the ${\mathrm {Z}} $ boson and the photon. In a framework of TeV-scale quantum gravity based on a renormalization of Newton’s constant, the search for non-resonant contributions to the $\mathrm {e}$ ${\mu }$ mass spectrum excludes QBH production below a threshold mass $M_{\mathrm {th}}$ of 1.99 $~\text {TeV}$ . In models that invoke extra dimensions, the bounds range from 2.36 $~\text {TeV}$ for one extra dimension to 3.63 $~\text {TeV}$ for six extra dimensions. Furthermore, this is the first search for QBHs decaying into the $\mathrm {e}$ ${\mu }$ final state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-374: Sensitivity of ArcCHECK to Tomotherapy Delivery Errors: Dependence On Analysis Technique

Purpose: ArcCHECK (Sun Nuclear) is a cylindrical diode array detector allowing three-dimensional sampling of dose, particularly useful in treatment delivery QA of helical tomotherapy. Gamma passing rate is a common method of analyzing results from diode arrays, but is less intuitive in 3D with complex measured dose distributions. This study explores the sensitivity of gamma passing rate to choice of analysis technique in the context of its ability to detect errors introduced into the treatment delivery. Methods: Nine treatment plans were altered to introduce errors in: couch speed, gantry/sonogram synchronization, and leaf open time. Each plan was then delivered to ArcCHECK in each of the following arrangements: “offset,” when the high dose area of the plan is delivered to the side of the phantom so that some diode measurements will be on the order of the prescription dose, and “centered,” when the high dose is in the center of the phantom where an ion chamber measurement may be acquired, but the diode measurements are in the mid to low-dose region at the periphery of the plan. Gamma analysis was performed at 3%/3mm tolerance and both global and local gamma criteria. The threshold of detectability for each error type was calculated as the magnitude at which the gamma passing rate drops below 90%. Results: Global gamma criteria reduced the sensitivity in the offset arrangement (from 2.3% to 4.5%, 8° to 21°, and 3ms to 8ms for couch-speed decrease, gantry-error, and leaf-opening increase, respectively). The centered arrangement detected changes at 3.3%, 5°, and 4ms with smaller variation. Conclusion: Each arrangement has advantages; offsetting allows more sampling of the higher dose region, while centering allows an ion chamber measurement and potentially better use of tools such as 3DVH, at the cost of positioning more of the diodes in the sometimes noisy mid-dose region.

60 APPLIED LIFE SCIENCES↗

CMB-HD: an Ultra-Deep, High-Resolution Millimeter-Wave Survey over Half the Sky

A millimeter-wave survey over half the sky, that spans frequencies in the range of 30 to 350 gigahertz, and that is both an order of magnitude deeper and of higher-resolution than currently funded surveys would yield an enormous gain in understanding of both fundamental physics and astrophysics. By providing such a deep, high-resolution millimeter-wave survey (about 0.5 microK-arcminutes noise and 15 arcseconds resolution at 150 gigahertz), CMB-HD (Cosmic Microwave Background - Henry Draper catalog entry) will enable major advances. It will allow 1) the use of gravitational lensing of the primordial microwave background to map the distribution of matter on small scales (k approximately equal to 10 h per megaparsec), which probes dark matter particle properties. It will also allow 2) measurements of the thermal and kinetic Sunyaev-Zel’dovich effects on small scales to map the gas density and gas pressure profiles of halos over a wide field, which probes galaxy evolution and cluster astrophysics. In addition, CMB-HD would allow us to cross critical thresholds in fundamental physics: 3) ruling out or detecting any new, light (less than 0.1 electronvolts), thermal particles, which could potentially be the dark matter, and 4) testing a wide class of multi-field models that could explain an epoch of inflation in the early Universe. Such a survey would also 5) monitor the transient sky by mapping the full observing region every few days, which opens a new window on gamma-ray bursts, novae, fast radio bursts, and variable active galactic nuclei. Moreover, CMB-HD would 6) provide a census of planets, dwarf planets, and asteroids in the outer Solar System, and 7) enable the detection of exo-Oort clouds around other solar systems, shedding light on planet formation. The combination of CMB-HD with contemporary ground and space-based experiments will also provide powerful synergies. CMB-HD will deliver this survey in 5 years of observing 20,000 square degrees, using two new 30-meter-class off-axis cross-Dragone telescopes to be located at Cerro Toco in the Atacama Desert. The telescopes will field about 2.4 million detectors (600,000 pixels) in total. The CMB-HD survey will be made publicly available, with usability and accessibility a priority.

Sehgal, Neelima↗

Accuracy Analysis of a Robotic Radionuclide Inspection and Mapping System for Surface Contamination

The mapping of localized regions of radionuclide contamination in a building can be a time consuming and costly task. Humans moving hand-held radiation detectors over the target areas are subject to fatigue. A contamination map based on manual surveys can contain significant operator-induced inaccuracies. A Fanuc M16i light industrial robot has been configured for installation on a mobile aerial work platform, such as a tall forklift. When positioned in front of a wall or floor surface, the robot can map the radiation levels over a surface area of up to 3 m by 3 m. The robot's end effector is a commercial alpha-beta radiation sensor, augmented with range and collision avoidance sensors to ensure operational safety as well as to maintain a constant gap between surface and radiation sensors. The accuracy and repeatability of the robotically conducted contamination surveys is directly influenced by the sensors and other hardware employed. This paper presents an in-depth analysis of various non-contact sensors for gap measurement, and the means to compensate for predicted systematic errors that arise during the area survey scans. The range sensor should maintain a constant gap between the radiation counter and the surface being inspected. The inspection robot scans the wall surface horizontally, moving down at predefined vertical intervals after each scan in a meandering pattern. A number of non-contact range sensors can be employed for the measurement of the gap between the robot end effector and the wall. The nominal gap width was specified as 10 mm, with variations during a single scan not to exceed {+-} 2 mm. Unfinished masonry or concrete walls typically exhibit irregularities, such as holes, gaps, or indentations in mortar joints. These irregularities can be sufficiently large to indicate a change of the wall contour. The responses of different sensor types to the wall irregularities vary, depending on their underlying principles of operation. We explored capacitive, ultrasound, and optical Laser range sensors. The unshielded capacitive range sensors were found to be influenced by objects in their vicinity, and to have comparatively low sensitivity. Therefore they were not used for gap measurement. We did, however, use them successfully to detect obstacles in the field of motion of the sensor head. The four sensors pointing diagonally from four corners of the sensor head are capacitive range sensors, which stop the robot motion any time a pre-set threshold signal level is exceeded. Ultrasound range sensors were found to have good resolution. The ultrasound beam was frequently deflected sideways by the wall's roughness, resulting in a spurious signal peaks. On the other hand, ultrasound signals are inherently insensitive to variations of the optical surface properties. Laser range sensing proved to be generally less noisy than ultrasound measurements. The aforementioned sensitivity to the target surface's optical properties was not evident on grey, non-reflective surfaces. On such surfaces, laser range sensing was found to be superior to ultrasound measurements. Occasionally, however, surface reflectivity and specularity caused erroneous measurements. The computational burden of measuring and filtering the sensor data in real time made it impractical to control the robot directly based on sensor feedback. The robot performs a first horizontal surface range scan merely to gage the surface profile. During the subsequent passes, the robot records the radiation measurements, while recording the range data for the next pass, with the range sensor positioned below the radiation sensor. The decoupling of measurements from robot control prevents the robot controller from responding to spurious sensor signals, ensuring steadier and safer radiation surveying. The controller is configured to accept either optical or ultrasound range signals, so as to respond better to user-specific requirements. A detailed analysis of non-contact range sensors and control for the automated mapping of surface contamination has been presented. The Contamination Survey Machine was tested and is operational.

42 ENGINEERING↗

A Quench Detection and Monitoring System for Superconducting Magnets at Fermilab

A quench detection system was developed for protecting and monitoring the superconducting solenoids for the Muon-to-Electron Conversion Experiment (Mu2e) at Fermilab. The quench system was designed for a high level of dependability and long-term continuous operation. It is based on three tiers: Tier-I, FPGA-based Digital Quench Detection (DQD); Tier-II, Analog Quench Detection (AQD); and Tier-3, the quench controls and data management system. The Tier-I and Tier-II are completely independent and fully redundant systems. The Tier-3 system is based on National Instruments (NI) C-RIO and provides the user interface for quench controls and data management. It is independent from Tiers I & II. The DQD provides both quench detection and quench characterization (monitoring) capability. Both DQD and AQD have built-in high voltage isolation and user programmable gains and attenuations. The DQD and AQD also includes user configured current dependent thresholding and validation times. A 1 st article of the three-tier system was fully implemented on the new Fermilab magnet test stand for the HL-LHC Accelerator Up-grade Project (AUP). It successfully provided quench protection and monitoring (QPM) for a cold superconducting bus test in November 2020. The Mu2e quench detection design has since been implemented for production testing of the AUP magnets. A detailed description of the system along with results from the AUP superconducting bus test will be presented.

monitoring↗