Search NASA⌕ Search

SEARCH · Search NASA

Results for “arraying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Numerical studies of ablated-plasma dynamics and precursor current of wire-array Z-pinches

The dynamics of ablated plasmas of wire-array Z-pinches are studied numerically in (r,{theta}) geometry by using the magnetohydrodynamic (MHD) simulation model in which the mass injection boundary conditions are presented, and two-dimensional spatio-temporal distributions of magnetic field and precursor current during the ablation phase are obtained. The ablated-plasma dynamics contains four processes: drifting toward the axis, arriving at the axis and forming the precursor column, and contraction and expansion of the precursor column. The relationship among the maximum inward velocity of ablated plasma streams and the initial wire array parameters is analyzed and it is found that this velocity is relatively sensitive to the change of inter-wire separation but weakly depends on the original array radius. The results are in reasonable agreement with the experiments on MAGPIE facility. The origin of the current flow in the precursor plasmas is analyzed from the point of view of the B-field convection in (r,{theta}) plane. The dynamics of ablation streams determine the distribution of magnetic field and the current density J{sub z} inside the wire array. The precursor current can be approximately calculated by the integral of J{sub z} inside the region of a radius near to the column. In this model, the fraction of precursor current is less than 10% of the total current, which is close to the experimental results. When the current waveform is fixed, the increase of the inter-wire gap or decrease of the initial radius will lead to the increase of the precursor current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a twin crystal membrane coupled conformable phased array for the inspection of austenitic welds

The inspection of welded austenitic stainless steel components can be challenging. Austenitic welds contain an anisotropic, inhomogeneous grain structure which causes attenuation, scattering and beam bending. The inspection of components where the weld cap has not been removed is even more difficult due to the irregularity of the surface geometry. A twin crystal membrane coupled device has now been produced containing two linear phased arrays positioned adjacent to one another within the same housing. The arrays are angled relative to one another so that the transducer provides a pseudo-focusing effect at a depth corresponding to the beam crossing point. This type of design is used to improve the signal to noise ratio of the defect response in comparison to simple linear phased array transducer designs and to remove an internal noise signal found in linear phased array devices. Experimental results obtained from the through weld inspection of an austenitic stainless steel component with an undressed weld cap using the twin crystal membrane device are presented. These results demonstrate that small lack of side wall fusion defects can be reliably detected in large complex structures.

42 ENGINEERING↗

A carbon nanotube field emission multipixel x-ray array source for microradiotherapy application

The authors report a carbon nanotube (CNT) field emission multipixel x-ray array source for microradiotherapy for cancer research. The developed multipixel x-ray array source has 50 individually controllable pixels and it has several distinct advantages over other irradiation source including high-temporal resolution (millisecond level), the ability to electronically shape the form, and intensity distribution of the radiation fields. The x-ray array was generated by a CNT cathode array (5x10) chip with electron field emission. A dose rate on the order of >1.2 Gy/min per x-ray pixel beam is achieved at the center of the irradiated volume. The measured dose rate is in good agreement with the Monte Carlo simulation result.

43 PARTICLE ACCELERATORS↗

Wire number dependence of the implosion dynamics, stagnation, and radiation output of tungsten wire arrays at Z driver

We report results of the experimental campaign, which studied the initiation, implosion dynamics, and radiation yield of tungsten wire arrays as a function of the wire number. The wire array dimensions and mass were those of interest for the Z-pinch driven Inertial Confinement Fusion (ICF) program. An optimization study of the x-ray emitted peak power, rise time, and full width at half maximum was effectuated by varying the wire number while keeping the total array mass constant and equal to {approx}5.8 mg. The driver utilized was the {approx}20-MA Z accelerator before refurbishment in its usual short pulse mode of 100 ns. We studied single arrays of 20-mm diameter and 1-cm height. The smaller wire number studied was 30 and the largest 600. It appears that 600 is the highest achievable wire number with present day's technology. Radial and axial diagnostics were utilized including crystal monochromatic x-ray backlighter. An optimum wire number of {approx}375 was observed which was very close to the routinely utilized 300 for the ICF program in Sandia.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The interaction of polarized microwaves with planar arrays of femtosecond laser-produced plasma filaments in air

The interaction of polarized microwaves with subwavelength arrays of parallel plasma filaments, such as those produced by the propagation of high-power femtosecond laser pulses in ambient air, was investigated by calculating the reflection and transmission coefficients as a function of the incidence angles using the finite-difference time-domain (FDTD) method. The time evolution of these coefficients was calculated and compared with experiments. It is found that the plasma filaments array becomes transparent when the polarization of the microwave radiation is perpendicular to the filaments axis, regardless the incidence angle of the microwave with respect to the filaments, except near grazing incidence. Increasing the filaments electron density or diameter, or decreasing the electron collision frequency or filaments spacing, decreases the transmission and increases the reflection. Transmission decreases when increasing the number of filament layers while reflection remains unchanged as the number of filament layers exceeds a given number ({approx}3 in our case). Transmission slightly increases when disorder is introduced in the filament arrays. The detailed calculation results are compared with those obtained from the simple birefringent slab model, which provides a convenient framework to calculate approximately the properties of filament arrays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The screening effects of carbon nanotube arrays and its field emission optimum density

In order to investigate the field emission optimum density of carbon nanotube (CNT) array, the screening effects of CNT array have been studied. It has been shown that the electric field in the vicinity of an individual nanotube of array can be notable distorted due to the screening action of the surrounding neighbors. The optimum normalized spacing s/l(as referred to the length) for the maximum emission current is inversely proportional to aspect ratio l/r and electric field strength for CNT arrays with a fixed dimension.

36 MATERIALS SCIENCE↗

Capacitive micromachined ultrasonic transducer arrays as tunable acoustic metamaterials

Capacitive Micromachined Ultrasonic Transducers (CMUTs) operating in immersion support dispersive evanescent waves due to the subwavelength periodic structure of electrostatically actuated membranes in the array. Evanescent wave characteristics also depend on the membrane resonance which is modified by the externally applied bias voltage, offering a mechanism to tune the CMUT array as an acoustic metamaterial. The dispersion and tunability characteristics are examined using a computationally efficient, mutual radiation impedance based approach to model a finite-size array and realistic parameters of variation. The simulations are verified, and tunability is demonstrated by experiments on a linear CMUT array operating in 2-12 MHz range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation of the ultrasonic array response from real branched cracks using an efficient finite element method

A hybrid model to simulate the ultrasonic array response from stress corrosion cracks is presented. These cracks are branched and difficult to detect so the model is required to enable optimization of an array design. An efficient frequency-domain finite element method is described and selected to simulate the ultrasonic scattering. Experimental validation results are presented, followed by an example of the simulated ultrasonic array response from a real stress corrosion crack whose geometry is obtained from an X-ray Computed Tomography image. A simulation-assisted array design methodology, which includes the model and use of real crack geometries, is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New customizable phased array UT instrument opens door for furthering research and better industrial implementation

Phased array UT as an inspection technique in itself continues to gain wide acceptance. However, there is much room for improvement in terms of implementation of Phased Array (PA) technology for every unique NDT application across several industries (e.g. oil and petroleum, nuclear and power generation, steel manufacturing, etc.). Having full control of the phased array instrument and customizing a software solution is necessary for more seamless and efficient inspections, from setting the PA parameters, collecting data and reporting, to the final analysis. NDT researchers and academics also need a flexible and open platform to be able to control various aspects of the phased array process. A high performance instrument with advanced PA features, faster data rates, a smaller form factor, and capability to adapt to specific applications, will be discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effect of antiferromagnetic layer thickness on exchange bias, training effect, and magnetotransport properties in ferromagnetic/antiferromagnetic antidot arrays

The effect of antiferromagnetic (AFM) layer on exchange bias (EB), training effect, and magnetotransport properties in ferromagnetic (FM) /AFM nanoscale antidot arrays and sheet films Ag(10 nm)/Co(8 nm)/NiO(t{sub NiO})/Ag(5 nm) at 10 K is studied. The AFM layer thickness dependence of the EB field shows a peak at t{sub NiO} = 2 nm that is explained by using the random field model. The misalignment of magnetic moments in the three-dimensional antidot arrays causes smaller decrease of EB field compared with that in the sheet films for training effect. The anomalous magnetotransport properties, in particular positive magnetoresistance (MR) for antidot arrays but negative MR for sheet films are found. The training effect and magnetotransport properties are strongly affected by the three-dimensional spin-alignment effects in the antidot arrays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Numerical and experimental investigations on the interaction of light wire-array Z-pinches with embedded heavy foam converters

The interaction of a light tungsten wire-array Z-pinch with an embedded heavy foam converter, whose mass ratio is typically less than 0.16, is numerically analyzed and experimentally investigated on the 1.3 MA “QiangGuang I” facility. Computational results show that this implosion process can be divided into three stages: acceleration of the tungsten wire-array plasma, collision, and stagnation. The tungsten plasma is accelerated to a high speed by the J × B force and interacts weakly with the foam plasma in the first stage. Strong energy conversions take place in the second collision stage. When the high speed tungsten plasma impacts on the foam converter, the plasma is thermalized and a radial radiation peak is produced. Meanwhile, a shock wave is generated due to the collision. After the shock rebounds from the axis and meets the W/Foam boundary, the plasma stagnates and the second radial radiation peak appears. The collision and stagnation processes were observed and the two-peak radial radiation pulse was produced in experiments. Increasing the wire-array radius from 4 mm to 6 mm, the kinetic energy of the tungsten plasma is increased, causing a stronger thermalization and generating a higher first radiation peak. Experimental results also showed a higher ratio of the first peak to the second peak in the case of larger wire-array radius. If we add a thin CH film cover onto the surface of the embedded foam converter, the first radiation peak will be hardly changed, because the acceleration of the tungsten plasma is not evidently affected by the film cover. However, the second radiation peak decreases remarkably due to the large load mass and the corresponding weak compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of horn antenna mixer array with internal local oscillator module for microwave imaging diagnostics

A new antenna array is proposed in order to improve the sensitivity and complexity of microwave imaging diagnostics systems such as a microwave imaging reflectometry, a microwave imaging interferometer, and an electron cyclotron emission imaging. The antenna array consists of five elements: a horn antenna, a waveguide-to-microstrip line transition, a mixer, a local oscillation (LO) module, and an intermediate frequency amplifier. By using an LO module, the LO optics can be removed, and the supplied LO power to each element can be equalized. We report details of the antenna array and characteristics of a prototype antenna array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual array 3D electron cyclotron emission imaging at ASDEX Upgrade

In a major upgrade, the (2D) electron cyclotron emission imaging diagnostic (ECEI) at ASDEX Upgrade has been equipped with a second detector array, observing a different toroidal position in the plasma, to enable quasi-3D measurements of the electron temperature. The new system will measure a total of 288 channels, in two 2D arrays, toroidally separated by 40 cm. The two detector arrays observe the plasma through the same vacuum window, both under a slight toroidal angle. The majority of the field lines are observed by both arrays simultaneously, thereby enabling a direct measurement of the 3D properties of plasma instabilities like edge localized mode filaments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental studies and micromagnetic simulations of electrodeposited Co nanotube arrays

Magnetic hollow nanotubes of cobalt forming close-packed arrays are synthesized by controlling the growth during electrodeposition in AAO template. Superconducting quantum interference device (SQUID) magnetometry is used to experimentally measure the static magnetization of the array of nanotubes. Excellent qualitative agreements of SQUID and micromagnetic simulations for static measurements are observed. This motivates us to evaluate dynamic response measurements via micromagnetic simulations. The coercivity simulated along the longitudinal axis of the nanotube is found increase with the length of isolated as well as for array of nanotubes. The effect of interactions is also clearly observed both in static as well as in dynamic evaluations. The interactions cause reduction in coercivity along with the switching which depends upon the length of the nanotubes. The calculation for FMR modes also indicates that propagation of the spin waves are greatly influenced by the hollow centre of nanotube as compare to nanowire and support to maintain the stable vortex configuration. For array of nanotubes, multiple peaks are found over larger number of frequencies which is anticipated due the interactions between nanotubes. Simulation for bias field and angular dependence of spin wave modes also yields a significant influenced by the presence of neighbouring nanotubes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced reflection from inverse tapered nanocone arrays

We computationally and experimentally demonstrate enhanced reflection effects displayed by silicon-based inverted nanocone arrays. A 3D finite element model is used to characterize the optical properties of the nanocone arrays with respect to the change in polarization and incident angles. The nanocone arrays are fabricated by e-beam lithography in hexagonal and triangular geometries with a lattice constant of 300 nm. The fabricated devices show a two-fold increase in reflection compared with bare silicon surface, as well as a strong diffraction within the visible and near-infrared spectra. The nanocone arrays may find a variety of applications from optical devices to energy conservation technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Zonal wavefront estimation using an array of hexagonal grating patterns

Accuracy of Shack-Hartmann type wavefront sensors depends on the shape and layout of the lenslet array that samples the incoming wavefront. It has been shown that an array of gratings followed by a focusing lens provide a substitution for the lensslet array. Taking advantage of the computer generated holography technique, any arbitrary diffraction grating aperture shape, size or pattern can be designed with little penalty for complexity. In the present work, such a holographic technique is implemented to design regular hexagonal grating array to have zero dead space between grating patterns, eliminating the possibility of leakage of wavefront during the estimation of the wavefront. Tessellation of regular hexagonal shape, unlike other commonly used shapes, also reduces the estimation error by incorporating more number of neighboring slope values at an equal separation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A six-channel pediatric coil array for detection of children spinal pathologies by MRI at 1.5 Tesla

Nowadays, magnetic resonance (MR) in Mexico has become a standard technique for clinical imaging. Although most of the times the MR systems contain only coils oriented for adults. Radiologists use these coils for children studies due to the non-availability of pediatric coils. Image quality is decreased due to the low signal to noise ratio delivered to the system. The development of RF coils is always focused towards increasing SNR and optimizing the RF penetration into the sample. Moreover, spinal pathologies in children, which are an important topic in pediatric care, cover congenital and neuromuscular disorders that occur in childhood. In this work, the design of a dedicated six-channel coil for detection of spinal pathologies at 1.5 Tesla is addressed. Numerical electromagnetic simulations were performed in order to evaluate their magnetic field performance at (63.6 MHz) 1.5 Tesla. The magnetic field uniformity as well as the RF penetration depth of the coil configurations was evaluated in order to find the best/optimized coil array configuration. The coil is comprised of three rows, one with 4 coil elements and two with only one coil element. Phantom and in vivo images were acquired with the six-channel pediatric coil array. The phantom images agree with the simulated data. In vivo images acquired with the 6-channel pediatric coil array have shown very good penetration depth and homogeneity, which allow better image quality throughout the whole FOV. In addition, the parallel imaging capabilities of the array allow the acceleration of the experiments avoiding possible motion artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Highly efficient ultrathin-film amorphous silicon solar cells on top of imprinted periodic nanodot arrays

The addressing of the light absorption and conversion efficiency is critical to the ultrathin-film hydrogenated amorphous silicon (a-Si:H) solar cells. We systematically investigate ultrathin a-Si:H solar cells with a 100 nm absorber on top of imprinted hexagonal nanodot arrays. Experimental evidences are demonstrated for not only notable silver nanodot arrays but also lower-cost ITO and Al:ZnO nanodot arrays. The measured external quantum efficiency is explained by the simulation results. The J{sub sc} values are 12.1, 13.0, and 14.3 mA/cm{sup 2} and efficiencies are 6.6%, 7.5%, and 8.3% for ITO, Al:ZnO, and silver nanodot arrays, respectively. Simulated optical absorption distribution shows high light trapping within amorphous silicon layer.

77 NANOSCIENCE AND NANOTECHNOLOGY↗