Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

The GCT camera for the Cherenkov Telescope Array

The Gamma Cherenkov Telescope (GCT) is one of the designs presented for the Small Sized Telescope (SST) section of the Cherenkov Telescope Array (CTA). The GCT uses dual-mirror optics, resulting in a compact telescope with good image quality and a large field of view with a smaller, more economical, camera than is achievable with conventional single mirror solutions. The photon counting GCT camera is designed to record the flashes of atmospheric Cherenkov light from gamma and cosmic ray initiated cascades, which last only a few tens of nanoseconds. The GCT optics require that the camera detectors follow a convex surface with a radius of curvature of 1 m and a diameter of ~35 cm, which is approximated by tiling the focal plane with 32 modules. The initial camera prototype is equipped with multi-anode photomultipliers, each comprising an 8×8 array of 6×6 mm 2 pixels to provide the required angular scale, adding up to 2048 pixels in total. Detector signals are shaped, amplified and digitised by electronics based on custom ASICs that provide digitisation at 1 GSample/s. The camera is self-triggering, retaining images where the focal plane light distribution matches predefined spatial and temporal criteria. The electronics are housed in the liquid-cooled, sealed camera enclosure. LED flashers at the corners of the focal plane provide a calibration source via reflection from the secondary mirror. The first GCT camera prototype underwent preliminary laboratory tests last year. In November 2015, the camera was installed on a prototype GCT telescope (SST-GATE) in Paris and was further used to successfully record the first Cherenkov light of any CTA prototype, and the first Cherenkov light seen with such a dual-mirror optical system. A second full-camera prototype based on Silicon Photomultipliers is under construction. Up to 35 GCTs are envisaged for CTA.

47 OTHER INSTRUMENTATION↗

Characterization of Advanced Imaging Systems for High-Resolution and Event-Mode Detection

Post-irradiation examination (PIE) is a continually growing field critical to the development of improved nuclear fuels. To characterize these materials, neutron imaging systems are employed and outfitted with, typically, CMOS or CCD cameras - complementary metal oxide semiconductor sensors and charge-couple devices. Imaging systems are a team-effort between the camera, scintillating materials, and object of interest, as a result of neutrons' inherent need to be converted to a detectable signal. High resolution imaging, flash radiography imaging, and event-mode detection systems are three systems undergoing development, construction, and characterization for improved spatial resolution and time-of-flight detection for PIE efforts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The IUE spacecraft and instrumentation

The paper describes the general design, instrumentation, and ground control system of the International Ultraviolet Explorer (IUE) satellite, which will serve as an astronomical observatory providing both high and low resolution UV spectra of sources other than the sun. Basic data are given on the telescope, the UV-visible converter, the spectrograph optics, the camera response, and the communications systems.

Boggess, A.↗

Performance of a high-sensitivity dedicated cardiac SPECT scanner for striatal uptake quantification in the brain based on analysis of projection data

Purpose: The authors have previously reported the advantages of high-sensitivity single-photon emission computed tomography (SPECT) systems for imaging structures located deep inside the brain. DaTscan (Isoflupane I-123) is a dopamine transporter (DaT) imaging agent that has shown potential for early detection of Parkinson disease (PD), as well as for monitoring progression of the disease. Realizing the full potential of DaTscan requires efficient estimation of striatal uptake from SPECT images. They have evaluated two SPECT systems, a conventional dual-head gamma camera with low-energy high-resolution collimators (conventional) and a dedicated high-sensitivity multidetector cardiac imaging system (dedicated) for imaging tasks related to PD. Methods: Cramer-Rao bounds (CRB) on precision of estimates of striatal and background activity concentrations were calculated from high-count, separate acquisitions of the compartments (right striata, left striata, background) of a striatal phantom. CRB on striatal and background activity concentration were calculated from essentially noise-free projection datasets, synthesized by scaling and summing the compartment projection datasets, for a range of total detected counts. They also calculated variances of estimates of specific-to-nonspecific binding ratios (BR) and asymmetry indices from these values using propagation of error analysis, as well as the precision of measuring changes in BR on the order of the average annual decline in early PD. Results: Under typical clinical conditions, the conventional camera detected 2 M counts while the dedicated camera detected 12 M counts. Assuming a normal BR of 5, the standard deviation of BR estimates was 0.042 and 0.021 for the conventional and dedicated system, respectively. For an 8% decrease to BR = 4.6, the signal-to-noise ratio were 6.8 (conventional) and 13.3 (dedicated); for a 5% decrease, they were 4.2 (conventional) and 8.3 (dedicated). Conclusions: This implies that PD can be detected earlier with the dedicated system than with the conventional system; therefore, earlier identification of PD progression should be possible with the high-sensitivity dedicated SPECT camera.

60 APPLIED LIFE SCIENCES↗

Calculation of spatial response of 2D beam emission spectroscopy diagnostic on MAST

The beam emission spectroscopy (BES) turbulence diagnostic on MAST is to be upgraded in June 2010 from a one-dimensional trial system to a two-dimensional imaging system (8 radialx4 poloidal channels) based on a newly developed avalanche photodiode array camera. The spatial resolution of the new system is calculated in terms of the point spread function to account for the effects of field-line curvature, observation geometry, the finite lifetime of the excited state of the beam atoms, and beam attenuation and divergence. It is found that the radial spatial resolution is {approx}2-3 cm and the poloidal spatial resolution {approx}1-5 cm depending on the radial viewing location. The absolute number of detected photons is also calculated, hence the photon noise level can be determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-ray imaging with a rotating hexagonal uniformly redundant array

Laboratory experiments have been performed to demonstrate the capabilities of a gamma-ray imaging system employing a NaI Anger camera and a rotating coded aperture mask. The mask incorporates in its design a new type of hexagonal uniformly redundant array (HURA) which is essentially antisymmetric under 60 deg rotation. The image formation techniques are described and results are presented that demonstrate the imaging capability of the system for individual and multiple point sources of gamma-ray emission. The results are compared to analytical predictions for the imaging and point source localization capabilities of coded aperture systems using continuous detectors.

Cook, W. R.↗

Viper Science Operations: Science Traverse Planning Perspectives, Processes, and Tools.

Introduction: The NASA Volatiles Investigating Polar Exploration Rover (VIPER) launchesin late 2024 towards a landing site on Mons Mouton in the Nobile region of the Lunar South Pole (LSP). As described in other LPSC presentations [1,2,3], the primary objective of the VIPER mission is to study the composition and distribution of hydrogen-bearing and other volatiles by way of a complementary suite of payloads that the rover will carry to the Moon: three “prospecting” instruments which operate continuously while roving - the Neutron Spectrometer System (NSS), the Near InfraRed Volatiles Spectrometer System (NIRVSS), and the Mass Spectrometer observing lunar operations (MSolo). A 1-meter auguring/percussive drill called the The Regolith and Ice Drill for Exploration of New Terrains (TRIDENT) is used to bring subsurface cuttings to the surface in 10-cm increments where they are interrogated by NIRVSS and MSolo. The Visible Imaging System is comprised of eight cameras (the NavCam stereo pair mounted on the mast gimbal, the AftCam stereo pair mounted on the aft panel, and four HazCams mounted in the wheel wells) that capture grayscale visible wavelength images of the lunar environment and the rover’s upper deck. The VIPER mobility system is a four-wheel design that includes the following motorized modules: Suspension, Steering, and Drive/Propulsion. Wheel odometry and applied torque — combined with position data from rover imagery — can be used to compute assessments of ‘slip and sinkage’. Slope estimates can be computed from stereo rover imagery, as well as pitch and roll data from the IMU (Inertial Measurement Unit) and Star Tracker telemetry.

Darlene Sze Shien Lim↗

Contactless Position Measurement System for Remote Alignment of Highly Reflective Objects

The Contactless Position Measurement System (CPMS) permits automatic alignment of highly-reflecting components that cannot or should not be touched by human hands, such as those used in SRF cavities. CPMS also has application during maintenance of fusion reactors, when the components in the reactor are radioactive. The length of time for which humans can handle the components in order to carry out maintenance or repairs is limited. We would like to measure the relative positions of such objects so we can bring them into alignment with motorized stages, thus eliminating the need for human contact. The CPMS is a computer vision system that measures the location of highly reflective components to within a fraction of a millimeter by finding the edges of silhouette images. This is done by placing a uniform, infrared backlight behind the components, and viewing each component with two low-aberration, infrared cameras. Each of these stereoscopic cameras are located within a coordinate system we set up with reference platforms, light sources, and survey cameras distributed around the perimeter of the string assembly room, or fusion reactor. We obtain stereoscopic silhouette images of each component, and we use these to determine the position of the component within our string assembly coordinate system. The CPMS combines the silhouette images with knowledge of the dimensions of the objects to obtain the relative positions of components in its field of view. These position measurements then allow us to mechanically maneuver the components into contact. Once we know where they are, we can move the components to where they are supposed to be with motorized stages or other mechanical means, check they are in the right place, and bolt them together. In Phase I, we built a prototype infrared backlights and cameras, tested it, wrote an analysis program to fit the images. At a range of 50 cm, we are able to measure the relative positions of two stainless steel flanges with an accuracy of 150 μm rms. The next steps are to test the analysis program with motorized stages, build a full-size prototype, and implement it in an cleanroom with SRF cavity assembly. This can be done in a cost effective way given the materials with which the system is designed. As Open Source Instruments achieved more in Phase I than anticipated, despite not receiving a Phase II SBIR grant, we hope to move forward with product development and sales with a testing partner.

43 PARTICLE ACCELERATORS↗

Hubble Space Telescope Wide Field Camera imaging of the gravitational lens 2237 + 0305

Images of the gravitational lens system 2237 + 0305, taken with the HST Wide Field Camera, are analyzed. Positions for the four quasar images, accurate to +/-0.015 arcsec, and relative magnitudes in U and R, accurate to +/-0.06 and 0.04 mag, respectively, are determined. The upper limits on the observed brightness of the fifth image are found to be less than or approximately equal to 7 percent of the brightest quasar image. The mass of the lens inside 0.9 arcsec is found to be 1.08 +/-0.02 x 10 exp 10 solar masses/h100 corresponding to a mass-to-light ratio in B of 12.3h100. This solar mass/solar luminosity estimate agrees with values obtained from stellar dynamics for other elliptical galaxies. A comparison of predictions from this mass model with the measured central velocity dispersion yields a distance-independent agreement to within 10 percent, assuming isotropic velocity dispersions.

Rix, Hans-Walter↗

Time-Resolved Imaging Of Transient Plasma

Pulsed capillary discharge is a compact device that is used to perform fast electrical discharge that is used to produce transient plasma. In this work, a more economical imaging technique is developed in order to study the dynamics of the plasma that is formed in a capillary tube. The imaging system consists of two main devices, a four-frame gated micro-channel plate and a Nikon Coolpix5000 camera. The time-resolved imaging that we have performed in order to study the dynamics of the plasma that is formed in a 10 mm long and 1 mm diameter low pressure capillary tube is reported. The images obtained portrayed that the plasma is heated up when the magnitude of the current is around the maximum and cools down when the current magnitude is around the minimum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of remote sensing techniques to hydrography with emphasis on bathymetry

Remote sensing techniques are utilized for the determination of hydrographic characteristics, with emphasis in bathymetry. Two sensor systems were utilized: the Metric Camera Wild RC-10 and the Multispectral Scanner of LANDSAT Satellite (MSS-LANDSAT). From photographs of the metric camera, data of photographic density of points with known depth are obtained. A correlation between the variables density x depth is calculated through a regression straight line. From this line, the depth of points with known photographic density is determined. The LANDSAT MSS images are interpreted automatically in the Iterative Multispectral Analysis System (I-100) with the obtention of point subareas with the same gray level. With some simplifications done, it is assumed that the depth of a point is directly related with its gray level. Subareas with points of the same depth are then determined and isobathymetric curves are drawn. The coast line is obtained through the sensor systems already mentioned. Advantages and limitations of the techniques and of the sensor systems utilized are discussed and the results are compared with ground truth.

Dejesusparada, N.↗

Motion of Drops on Surfaces with Wettability Gradients

A liquid drop present on a solid surface can move because of a gradient in wettability along the surface, as manifested by a gradient in the contact angle. The contact angle at a given point on the contact line between a solid and a liquid in a gaseous medium is the angle between the tangent planes to the liquid and the solid surfaces at that point and is measured within the liquid side, by convention. The motion of the drop occurs in the direction of increasing wettability. The cause of the motion is the net force exerted on the drop by the solid surface because of the variation of the contact angle around the periphery. This force causes acceleration of an initially stationary drop, and leads to its motion in the direction of decreasing contact angle. The nature of the motion is determined by the balance between the motivating force and the resisting hydrodynamic force from the solid surface and the surrounding gaseous medium. A wettability gradient can be chemically induced as shown by Chaudhury and Whitesides who provided unambiguous experimental evidence that drops can move in such gradients. The phenomenon can be important in heat transfer applications in low gravity, such as when condensation occurs on a surface. Daniel et al have demonstrated that the velocity of a drop on a surface due to a wettability gradient in the presence of condensation can be more than two orders of magnitude larger than that observed in the absence of condensation. In the present research program, we have begun to study the motion of a drop in a wettability gradient systematically using a model system. Our initial efforts will be restricted to a system in which no condensation occurs. The experiments are performed as follows. First, a rectangular strip of approximate dimensions 10 x 20 mm is cut out of a silicon wafer. The strip is cleaned thoroughly and its surface is exposed to the vapor from an alkylchlorosilane for a period lasting between one and two minutes inside a desiccator. This is done using an approximate line source of the vapor in the form of a string soaked in the alkylchlorosilane. Ordinarily, many fluids, including water, wet the surface of silicon quite well. This means that the contact angle is small. But the silanized surface resists wetting, with contact angles that are as large as 100 degs. Therefore, a gradient of wettability is formed on the silicon surface. The region near the string is highly hydrophobic, and the contact angle decreases gradually toward a small value at the hydrophilic end away from this region. The change in wettability occurs over a distance of several mm. The strip is placed on a platform within a Plexiglas cell. Drops of a suitable liquid are introduced on top of the strip near the hydrophobic end. An optical system attached to a video camera is trained on the drop so that images of the moving drop can be captured on videotape for subsequent analysis. We have performed preliminary experiments with water as well as ethylene glycol drops. Results from these experiments will be presented in the poster. Future plans include the refinement of the experimental system so as to permit images to be recorded from the side as well as the top, and the conduct of a systematic study in which the drop size is varied over a good range. Experiments will be conducted with different fluids so as to obtain the largest possible range of suitably defined Reynolds and Capillary numbers. Also, an effort will be initiated on theoretical modeling of this motion. The challenges in the development of the theoretical description lie in the proper analysis of the region in the vicinity of the contact line, as well as in the free boundary nature of the problem. It is known that continuum models assuming the no slip condition all the way to the contact line fail by predicting that the stress on the solid surface becomes singular as the contact line is approached. One approach for dealing with this issue has been to relax the no-slip boundary condition using the Navier model. Molecular dynamics simulations of the contact line region show that for a non-polar liquid on a solid surface, the no-slip boundary condition is in fact incorrect near the contact line. Furthermore, the same simulations also show that the usual relationship between stress and the rate of deformation breaks down in the vicinity of the contact line. In developing continuum theoretical models of the system, we shall accommodate this knowledge to the extent possible.

Subramanian, R. Shankar↗

The Mars observer camera

A camera designed to operate under the extreme constraints of the Mars Observer Mission was selected by NASA in April, 1986. Contingent upon final confirmation in mid-November, the Mars Observer Camera (MOC) will begin acquiring images of the surface and atmosphere of Mars in September-October 1991. The MOC incorporates both a wide angle system for low resolution global monitoring and intermediate resolution regional targeting, and a narrow angle system for high resolution selective surveys. Camera electronics provide control of image clocking and on-board, internal editing and buffering to match whatever spacecraft data system capabilities are allocated to the experiment. The objectives of the MOC experiment follow.

Malin, M. C.↗

NW-MILO Acoustic Data Collection

There is an enduring requirement to improve our ability to detect potential threats and discriminate these from the legitimate commercial and recreational activity ongoing in the nearshore/littoral portion of the maritime domain. The Northwest Maritime Information and Littoral Operations (NW-MILO) Program at PNNL’s Coastal Security Institute in Sequim, Washington is establishing a methodology to detect and classify these threats - in part through developing a better understanding of acoustic signatures in a near-shore environment. The purpose of the acoustic data collection described here is to investigate the acoustic signatures of small vessels. The data is being recorded continuously, 24 hours a day, along with radar track data and imagery. The recording began in August 2008, and to date the data contains tens of thousands of signals from small vessels recorded in a variety of environmental conditions. The quantity and variety of this data collection, with the supporting imagery and radar track data, makes it particularly useful for the development of robust acoustic signature models and advanced algorithms for signal classification and information extraction. The underwater acoustic sensing system is part of a multi-modal sensing system that is operating near the mouth of Sequim Bay. Sequim Bay opens onto the Straight of Juan de Fuca, which contains part of the border between the U.S. and Canada. Table 1 lists the specific components used for the NW-MILO system. The acoustic sensor is a hydrophone permanently deployed at a mean depth of about 3 meters. In addition to a hydrophone, the other sensors in the system are a marine radar, an electro-optical (EO) camera and an infra-red (IR) camera. The radar is integrated with a vessel tracking system (VTS) that provides position, speed and heading information. The data from all the sensors is recorded and saved to a central server. The data has been validated in terms of its usability for characterizing the signatures of small vessels. The sampling rate of 8 kHz and low pass filtering to 2 kHz results in an alias-free signal in the frequency band that is appropriate for small vessels. Calibration was performed using a Lubell underwater speaker so that the raw data signal levels can be converted to sound pressure. Background noise is present due to a nearby pump and as a result of tidal currents. More study is needed to fully characterize the noise, but it does not pose an obstacle to using the acoustic data for the purposes of vessel detection and signature analysis. The detection range for a small vessel was estimated using the calibrated voltage response of the system and a cylindrical spreading model for transmission loss. The sound pressure of a typical vessel with an outboard motor was found to be around 140 dB mPa, and could theoretically be detected from 10 km away. In practical terms, a small vessel could reliably be detected from 3 - 5 km away. The data is archived in netCDF files, a standard scientific file format that is "self describing". This means that each data file contains the metadata - timestamps, units, origin, etc. - needed to make the data meaningful and portable. Other file formats, such as XML, are also supported. A visualization tool has been developed to view the acoustic data in the form of spectrograms, along with the coincident radar track data and camera images.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Fast time-of-flight camera based surface registration for radiotherapy patient positioning

Purpose: This work introduces a rigid registration framework for patient positioning in radiotherapy, based on real-time surface acquisition by a time-of-flight (ToF) camera. Dynamic properties of the system are also investigated for future gating/tracking strategies. Methods: A novel preregistration algorithm, based on translation and rotation-invariant features representing surface structures, was developed. Using these features, corresponding three-dimensional points were computed in order to determine initial registration parameters. These parameters became a robust input to an accelerated version of the iterative closest point (ICP) algorithm for the fine-tuning of the registration result. Distance calibration and Kalman filtering were used to compensate for ToF-camera dependent noise. Additionally, the advantage of using the feature based preregistration over an ''ICP only'' strategy was evaluated, as well as the robustness of the rigid-transformation-based method to deformation. Results: The proposed surface registration method was validated using phantom data. A mean target registration error (TRE) for translations and rotations of 1.62 {+-} 1.08 mm and 0.07 deg. {+-} 0.05 deg., respectively, was achieved. There was a temporal delay of about 65 ms in the registration output, which can be seen as negligible considering the dynamics of biological systems. Feature based preregistration allowed for accurate and robust registrations even at very large initial displacements. Deformations affected the accuracy of the results, necessitating particular care in cases of deformed surfaces. Conclusions: The proposed solution is able to solve surface registration problems with an accuracy suitable for radiotherapy cases where external surfaces offer primary or complementary information to patient positioning. The system shows promising dynamic properties for its use in gating/tracking applications. The overall system is competitive with commonly-used surface registration technologies. Its main benefit is the usage of a cost-effective off-the-shelf technology for surface acquisition. Further strategies to improve the registration accuracy are under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of biostereometric experiments

The stereometric camera was designed for close-range techniques in biostereometrics. The camera focusing distance of 360 mm to infinity covers a broad field of close-range photogrammetry. The design provides for a separate unit for the lens system and interchangeable backs on the camera for the use of single frame film exposure, roll-type film cassettes, or glass plates. The system incorporates the use of a surface contrast optical projector.

Herron, R. E.↗

Testing of a Composite Wavelet Filter to Enhance Automated Target Recognition in SONAR

Automated Target Recognition (ATR) systems aim to automate target detection, recognition, and tracking. The current project applies a JPL ATR system to low resolution SONAR and camera videos taken from Unmanned Underwater Vehicles (UUVs). These SONAR images are inherently noisy and difficult to interpret, and pictures taken underwater are unreliable due to murkiness and inconsistent lighting. The ATR system breaks target recognition into three stages: 1) Videos of both SONAR and camera footage are broken into frames and preprocessed to enhance images and detect Regions of Interest (ROIs). 2) Features are extracted from these ROIs in preparation for classification. 3) ROIs are classified as true or false positives using a standard Neural Network based on the extracted features. Several preprocessing, feature extraction, and training methods are tested and discussed in this report.

image processing↗

Overview and Initial Results of SAND-E: Semi-Autonomous Navigation for Detrital Environments

Unmanned aerial systems (UAS) and automated terrain analysis for science and navigation are new technologies for planetary exploration. The Mars Helicopter will fly with the Mars2020 rover, the Dragonfly quadcopter will explore Titan, and Soil Properties and Object Classification (SPOC) software will be used for path planning and navigation on the Mars2020 rover. Using an Argo J5 rover instrumented with stereo cameras and Autonomous Soil Assessment System (ASAS) software, and an off the shelf quadcopter, SAND-E tested the use of automated terrain analysis and UAS data for science operations in a Mars-analog environment in Iceland during July of 2019. Scientifically, we sought to determine changes in the physical and chemical properties of sediments along a glacial-fluvial-aeolian transport pathway. Operationally, we tested rover mission-like scenarios that included UAS images and classified terrain images. Here, we present the initial results for both the operations and science elements of the study. Site Selection: A goal of SAND-E is examine sorting and alteration of sediments in fluvial and aeolian environments in both mineral-dominated and glass-dominated basaltic settings. During the first year of the project we focused on a mineral-dominated environment. Selection of the location was based on prior publications that indicated our selected region had a greater abundance of crystalline sediments than other areas fluvial-aeolian settings in Iceland. Other criteria included the presence of both fluvial and aeolian landforms along a transport pathway such that the sediments in transport could be linked to their source rocks. We chose the Skjaldbreidauhraun glacial outwash plain, which sits at the base of Thórisjökull glacier. The site is 30 km north of Thingvellir National Park and ~2 hours from Reykjavik. The outwash plain is fed by two small catchments that drain from the base of the glacier and cut through hyaloclastite and shield volcano bedrock. The drainage progresses from steep alluvial fans near the glacier into a low-sloping fluvial braidplain that becomes confined by the Skjaldbreidur shield volcano and creates a shallow canyon cut into lava bedrock. The fluvial system was a typical braided alluvial environment composed pebble- and cobble-bedded longitudinal bars and sandy channel beds. The river remained active and fluctuated in response to diurnal runoff cycles near the glacier before disappearing into the sandy substrate downstream. The high concentration of suspended sediment in the river was evident by the cloudy water and the silt and clay-sized sediments that draped the channel beds after abandonment and created playas in the lowest sloping areas of the catchment. The entire fluvial system was affected by the winds generated by frontal systems and katabatic flows descending the glacier. This resulted in the formation of aeolian lag deposits and a wind-deflation plain where the fluvial system was not active. Wind ripples and drifts formed in abandoned fluvial channels from aeolian reworking of the sand-sized fluvial sediments. The silt- and clay-sized sediments found in fluvial channels, bar tops, and playas generated dust plumes during high wind events. Our operation sought to capture the variability in this system by sampling from the range of fluvial and aeolian features 6.3 km (proximal), 11.3 km (medial), and 14.4 km (distal) along the river from its origin at the base of glacier.

Ewing, R. C.↗