Search NASA⌕ Search

SEARCH · Search NASA

Results for “cavity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Analysis of Niobium Electropolishing Using a Generalized Distribution of Relaxation Times Method

Using electrochemical impedance spectroscopy, we have devised a method of sensing the microscopic surface conditions on the surface of niobium as it is undergoing an electrochemical polishing (EP) treatment. The method uses electrochemical impedance spectroscopy (EIS) to gather information on the surface state of the electrode without disrupting the polishing reaction. The EIS data is analyzed using a so-called distribution of relaxation times (DRT) method. Using DRT, the EIS data can be deconvolved into discrete relaxation time peaks without any a priori knowledge of the electrode dynamics. By analyzing the relaxation time peaks, we are able to distinguish two distinct modes of the EP reaction. As the polishing voltage is increased, the electrode transitions from the low voltage EP mode, characterized by a single relaxation time peaks, to the high voltage EP mode, characterized by two relaxation time peaks. We theorize that this second peak is caused by the formation of an oxide layer on the electrode. We also find that this oxide induced peak transitions from to a negative relaxation time, which is indicative of a blocking electrode process. By analyzing EPed samples, we show that samples polished in the low voltage mode have significantly higher surface roughness due to grain etching and faceting. We find that the surface roughness of the samples only improves when the oxide film peak is present and in the negative relaxation time region. This shows that EIS combined with DRT analysis can be used to predict etching on EPed Nb. This method can also be performed before or during the EP, which could allow for adjustment of polishing parameters to guarantee a smooth cavity surface finish.

43 PARTICLE ACCELERATORS↗

Plasma Processing for In-Situ Field Emission Mitigation of Superconducting Radiofrequency (SRF) Cryomodules

Field emission (FE) is one of the main limiting factors of superconducting radio-frequency (SRF) cavities operating in accelerators and it occurs whenever contaminants, like dust, metal flakes or even absorbates, are present on the surface of the cavity high electric field region. Field emission reduces the maximum achievable accelerating field and generates free electrons that may interact with the beam, damage or activate the beamline. One practical method that can be used to mitigate this problem is in-situ plasma cleaning, or plasma processing. The development of a processing that can be applied in-situ is extremely advantageous, since it enables the recovery of the cryomodule performance without the need of disassembling the whole cryomodule, which is an extremely expensive and time-consuming process. On the other hand, plasma processing only requires the cryomodule warm-up to room-temperature and the subsequent processing of the contaminated cavities. The entire process is reasonably quick and involves a limited number of personnel. For these reasons we would like to advocate for continuing to invest in the R&D of plasma processing to optimize its applicability in cryomodules and for extending the technique to other frequency ranges and cavities geometries.

43 PARTICLE ACCELERATORS↗

Developing highly scalable fluid solvers for enabling multiphysics simulation.

We performed an investigation into explicit algorithms for the simulation of incompressible flows using methods with a finite, but small amount of compressibility added. Such methods include the artificial compressibility method and the lattice-Boltzmann method. The impetus for investigating such techniques stems from the increasing use of parallel computation at all levels (processors, clusters, and graphics processing units). Explicit algorithms have the potential to leverage these resources. In our investigation, a new form of artificial compressibility was derived. This method, referred to as the Entropically Damped Artificial Compressibility (EDAC) method, demonstrated superior results to traditional artificial compressibility methods by damping the numerical acoustic waves associated with these methods. Performance nearing that of the lattice- Boltzmann technique was observed, without the requirement of recasting the problem in terms of particle distribution functions; continuum variables may be used. Several example problems were investigated using a finite-di erence and finite-element discretizations of the EDAC equations. Example problems included lid-driven cavity flow, a convecting Taylor-Green vortex, a doubly periodic shear layer, freely decaying turbulence, and flow over a square cylinder. Additionally, a scalability study was performed using in excess of one million processing cores. Explicit methods were found to have desirable scaling properties; however, some robustness and general applicability issues remained.

Clausen, Jonathan R↗

Efficient modeling of photonic crystals with local Hermite polynomials

Developing compact algorithms for accurate electrodynamic calculations with minimal computational cost is an active area of research given the increasing complexity in the design of electromagnetic composite structures such as photonic crystals, metamaterials, optical interconnects, and on-chip routing. We show that electric and magnetic (EM) fields can be calculated using scalar Hermite interpolation polynomials as the numerical basis functions without having to invoke edge-based vector finite elements to suppress spurious solutions or to satisfy boundary conditions. This approach offers several fundamental advantages as evidenced through band structure solutions for periodic systems and through waveguide analysis. Compared with reciprocal space (plane wave expansion) methods for periodic systems, advantages are shown in computational costs, the ability to capture spatial complexity in the dielectric distributions, the demonstration of numerical convergence with scaling, and variational eigenfunctions free of numerical artifacts that arise from mixed-order real space basis sets or the inherent aberrations from transforming reciprocal space solutions of finite expansions. The photonic band structure of a simple crystal is used as a benchmark comparison and the ability to capture the effects of spatially complex dielectric distributions is treated using a complex pattern with highly irregular features that would stress spatial transform limits. This general method is applicable to a broad class of physical systems, e.g., to semiconducting lasers which require simultaneous modeling of transitions in quantum wells or dots together with EM cavity calculations, to modeling plasmonic structures in the presence of EM field emissions, and to on-chip propagation within monolithic integrated circuits.

36 MATERIALS SCIENCE↗

Nb₃Sn Coating of a 2.6 GHz SRF Cavity by Sputter Deposition Technique

Nb₃Sn is of interest as a coating for SRF cavities due to its higher transition temperature Tc ~18.3 K and superheating field Hsh ~400 mT, both are twice that of Nb. Nb₃Sn coated cavities can achieve high-quality factors at 4 K and can replace the bulk Nb cavities operated at 2 K. A cylindrical magnetron sputtering system was built, commissioned, and used to deposit Nb₃Sn on the inner surface of a 2.6 GHz single-cell Nb cavity. With two identical cylindrical magnetrons, this system can coat a cavity with high symmetry and uniform thickness. Using Nb-Sn multilayer sequential sputtering followed by annealing at 950°C for 3 hours, polycrystalline Nb₃Sn films were first deposited at the equivalent positions of the cavity’s beam tubes and equator. The film’s composition, crystal structure, and morphology were characterized by energy dispersive spectroscopy, X-ray diffraction, and atomic force microscopy. The Tc of the films was measured by the four-point probe method and was 17.61 to 17.76 K. Based on these studies, ~1.2 micron thick Nb₃Sn was deposited inside a 2.6 GHz Nb cavity. We will discuss first results from samples and cavity coatings, and the status of the coating system.

43 PARTICLE ACCELERATORS↗

Stochastic finite difference lattice Boltzmann method for steady incompressible viscous flows

With the advent of state-of-the-art computers and their rapid availability, the time is ripe for the development of efficient uncertainty quantification (UQ) methods to reduce the complexity of numerical models used to simulate complicated systems with incomplete knowledge and data. The spectral stochastic finite element method (SSFEM) which is one of the widely used UQ methods, regards uncertainty as generating a new dimension and the solution as dependent on this dimension. A convergent expansion along the new dimension is then sought in terms of the polynomial chaos system, and the coefficients in this representation are determined through a Galerkin approach. This approach provides an accurate representation even when only a small number of terms are used in the spectral expansion; consequently, saving in computational resource can be realized compared to the Monte Carlo (MC) scheme. Recent development of a finite difference lattice Boltzmann method (FDLBM) that provides a convenient algorithm for setting the boundary condition allows the flow of Newtonian and non-Newtonian fluids, with and without external body forces to be simulated with ease. Also, the inherent compressibility effect in the conventional lattice Boltzmann method, which might produce significant errors in some incompressible flow simulations, is eliminated. As such, the FDLBM together with an efficient UQ method can be used to treat incompressible flows with built in uncertainty, such as blood flow in stenosed arteries. The objective of this paper is to develop a stochastic numerical solver for steady incompressible viscous flows by combining the FDLBM with a SSFEM. Validation against MC solutions of channel/Couette, driven cavity, and sudden expansion flows are carried out.

97 MATHEMATICS AND COMPUTING↗

Methods for integrating a functional component into a microfluidic device

Injection molding is used to form microfluidic devices with integrated functional components. One or more functional components are placed in a mold cavity, which is then closed. Molten thermoplastic resin is injected into the mold and then cooled, thereby forming a solid substrate including the functional component(s). The solid substrate including the functional component(s) is then bonded to a second substrate, which may include microchannels or other features.

47 OTHER INSTRUMENTATION↗

Spectral Analysis of LDV Measurements inside of the TAMU Air-Cooled Reactor Cavity Cooling System - 18688

Spectral analysis was applied to the LDV measurements inside of the TAMU air-cooled RCCS facility at two different locations to both evaluate the feasibility of spectral methods for this experiment and gain a first insight into the flow behavior using a Fourier representation. Application of the wavelet transform showed that there are patterns in the flow signified by repeating frequencies and flow structures. Although the sampling rate of 7.92 Hz at the data point centered at the bottom center of riser 4 was lower than the higher frequency sampling rate of 57.92 Hz at the top data point of the upper plenum, the wavelet transforms of the higher frequency data point showed that the dominant frequencies were bounded within 4 Hz. Application of wavelet analysis is limited by the size of the interrogation window but may be modified according to the frequency range of interest by adjusting the size of the time width for the undilated Morlet mother wavelet. Spectral analysis can be applied to future experiments to understand uncharacterized flow behavior such as flow reversal inside of the upper plenum and for benchmarking future CFD simulations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Microfluidic structures and methods for integrating a functional component into a microfluidic device

Injection molding is used to form microfluidic devices with integrated functional components. One or more functional components are placed in a mold cavity which is then closed. Molten thermoplastic resin is injected into the mold and then cooled, thereby forming a solid substrate including the functional component(s). The solid substrate including the functional component(s) is then bonded to a second substrate which may include microchannels or other features.

42 ENGINEERING↗

Direct measurements of unimolecular and bimolecular reaction kinetics of the Criegee intermediate (CH 3 ) 2 COO

Here, the Criegee intermediate acetone oxide, (CH 3 ) 2 COO, is formed by laser photolysis of 2,2-diiodopropane in the presence of O 2 and characterized by synchrotron photoionization mass spectrometry and by cavity ring-down ultraviolet absorption spectroscopy. The rate coefficient of the reaction of the Criegee intermediate with SO 2 was measured using photoionization mass spectrometry and pseudo-first-order methods to be (7.3 ± 0.5) × 10 –11 cm 3 s –1 at 298 K and 4 Torr and (1.5 ± 0.5) × 10 –10 cm 3 s –1 at 298 K and 10 Torr (He buffer). These values are similar to directly measured rate coefficients of anti -CH 3 CHOO with SO 2 , and in good agreement with recent UV absorption measurements. The measurement of this reaction at 293 K and slightly higher pressures (between 10 and 100 Torr) in N 2 from cavity ring-down decay of the ultraviolet absorption of (CH 3 ) 2 COO yielded even larger rate coefficients, in the range (1.84 ± 0.12) × 10 –10 to (2.29 ± 0.08) × 10 –10 cm 3 s –1 . Photoionization mass spectrometry measurements with deuterated acetone oxide at 4 Torr show an inverse deuterium kinetic isotope effect, k H /k D = (0.53 ± 0.06), for reactions with SO 2 , which may be consistent with recent suggestions that the formation of an association complex affects the rate coefficient. The reaction of (CD3)2COO with NO2 has a rate coefficient at 298 K and 4 Torr of (2.1 ± 0.5) × 10 –12 cm 3 s –1 (measured with photoionization mass spectrometry), again similar to rate for the reaction of anti -CH 3 CHOO with NO 2 . Cavity ring-down measurements of the acetone oxide removal without added reagents display a combination of first- and second-order decay kinetics, which can be deconvolved to derive values for both the self-reaction of (CH 3 ) 2 COO and its unimolecular thermal decay. The inferred unimolecular decay rate coefficient at 293 K, (305 ± 70) s –1 , is similar to determinations from ozonolysis. The present measurements confirm the large rate coefficient for reaction of (CH 3 ) 2 COO with SO 2 and the small rate coefficient for its reaction with water. Product measurements of the reactions of (CH 3 ) 2 COO with NO 2 and with SO 2 suggest that these reactions may facilitate isomerization to 2-hydroperoxypropene, possibly by subsequent reactions of association products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Systems and methods for determining strength of cylindrical structures by internal pressure loading

In one embodiment, an apparatus, includes: a mandrel; an expansion cylinder, comprising: opposite first and second ends; an inner circumferential surface extending between the ends and characterized by an inner diameter, the inner circumferential surface defining a hollow cavity; an outer circumferential surface extending between the ends and characterized by an outer diameter that is greater than the inner diameter; and a plurality of slots extending from the inner circumferential surface to the outer circumferential surface and latitudinally oriented between the ends; and one or more base plates configured to engage one of the ends of the expansion cylinder. In another embodiment, a method includes: arranging an expansion cylinder inside a test cylinder; arranging a mandrel inside the expansion cylinder; applying a force to the mandrel for exerting a radial force on the expansion cylinder; and detecting one or more indicia of structural failure of the test cylinder.

42 ENGINEERING↗

Advanced Fluid Reduced Order Models for Compressible Flow.

This report summarizes fiscal year (FY) 2017 progress towards developing and implementing within the SPARC in-house finite volume flow solver advanced fluid reduced order models (ROMs) for compressible captive-carriage flow problems of interest to Sandia National Laboratories for the design and qualification of nuclear weapons components. The proposed projection-based model order reduction (MOR) approach, known as the Proper Orthogonal Decomposition (POD)/Least- Squares Petrov-Galerkin (LSPG) method, can substantially reduce the CPU-time requirement for these simulations, thereby enabling advanced analyses such as uncertainty quantification and de- sign optimization. Following a description of the project objectives and FY17 targets, we overview briefly the POD/LSPG approach to model reduction implemented within SPARC . We then study the viability of these ROMs for long-time predictive simulations in the context of a two-dimensional viscous laminar cavity problem, and describe some FY17 enhancements to the proposed model reduction methodology that led to ROMs with improved predictive capabilities. Also described in this report are some FY17 efforts pursued in parallel to the primary objective of determining whether the ROMs in SPARC are viable for the targeted application. These include the implemen- tation and verification of some higher-order finite volume discretization methods within SPARC (towards using the code to study the viability of ROMs on three-dimensional cavity problems) and a novel structure-preserving constrained POD/LSPG formulation that can improve the accuracy of projection-based reduced order models. We conclude the report by summarizing the key takeaways from our FY17 findings, and providing some perspectives for future work.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 25-October 6, 2023

The comparison of the absolute cavity pyrgeometers (ACPs) with the InfraRed Integrating Sphere (IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 25 to October 6, 2023. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. During the comparison, the average (av) irradiance difference measured by ACPs and IRIS9 varied from -0.75 W/m 2 to 0.76 W/m 2 , standard deviation (sd) from 0.78 W/m 2 to 1.04 W/m 2 , and uncertainty U95 from 1.96 W/m 2 to 2.07 W/m 2 . The average irradiance difference measured by ACP95F3 minus the irradiance measured by all pyrgeometers varied from 1.64 to 3.96 W/m 2 , sd from 1.70 W/m 2 to 1.86 W/m 2 , and uncertainty U 95 from 3.78 W/m 2 to 5.42W/m 2 . Note that from September 25th at 18:31 to September 29 th at 5:30 ACP96F3 irradiance is calculated using Bruce, et al 2023 method.

47 OTHER INSTRUMENTATION↗

On the implementation of a recently proposed dosimetric formalism to a robotic radiosurgery system

Purpose: The aim of this work is to implement a recently proposed dosimetric formalism for nonstandard fields to the calibration and small field output factor measurement of a robotic stereotactic radiosurgery system. Methods: Reference dosimetry measurements were performed in the nonstandard, 60 mm diameter machine specific reference (msr) field using a Farmer ion chamber, five other cylindrical chambers with cavity lengths ranging from 16.25 down to 2.7 mm, and alanine dosimeters. Output factor measurements were performed for the 5, 7.5, 10, and 15 mm field sizes using microchambers, diode detectors, alanine dosimeters, TLD microcubes, and EBT Gafchromic films. Measurement correction factors as described in the proposed formalism were calculated for the ion chamber and diode detector output factor measurements based on published Monte Carlo data. Corresponding volume averaging correction factors were calculated for the alanine output factor measurements using 3D dose distributions, measured with polymer gel dosimeters. Results: Farmer chamber and alanine reference dosimetry results were found in close agreement, yielding a correction factor of k{sub Q{sub m{sub s{sub r,Q}{sup f{sub m}{sub s}{sub r},f{sub r}{sub e}{sub f}}}}}=0.999{+-}0.016 for the chamber readings. These results were also found to be in agreement within experimental uncertainties with corresponding results obtained using the shorter cavity length ionization chambers. The mean measured dose values of the latter, however, were found to be consistently greater than that of the Farmer chamber. This finding, combined with an observed inverse relationship between the mean measured dose and chamber cavity length that follows the trend predicted by theoretical volume averaging calculations in the msr field, implies that the Farmer k{sub Q{sub m{sub s{sub r,Q}{sup f{sub m}{sub s}{sub r},f{sub r}{sub e}{sub f}}}}} correction is greater than unity. Regarding the output factor results, deviations as large as 33% were observed between the different dosimeters used. These deviations were substantially decreased when appropriate correction factors were applied to the measured microchamber, diode, and alanine values. After correction, all diode and microchamber measured output factors agreed within 1.6% with the corresponding alanine measurements, and within 3.1% with the TLD measurements. The weighted mean output factors were 0.681{+-}0.001, 0.824{+-}0.001, 0.875{+-}0.001, and 0.954{+-}0.001 for the 5, 7.5, 10, and 15 mm beams, respectively. Conclusions: The comparison of Farmer chamber measurements versus alanine reference dosimetry validates the use of the former for dosimetry in the msr field of this treatment delivery system. The corresponding results of this work obtained using chambers with different cavity lengths, combined with previous literature findings, suggest that a k{sub Q{sub m{sub s{sub r,Q}{sup f{sub m}{sub s}{sub r},f{sub r}{sub e}{sub f}}}}} Farmer chamber dose response correction factor of 1.01 may improve calibration measurement accuracy when using the proposed dosimetric formalism. The k{sub Q{sub m{sub s{sub r,Q}{sup f{sub m}{sub s}{sub r},f{sub r}{sub e}{sub f}}}}} correction factor is within 0.5% from unity for ion chambers with cavity lengths less than 10 mm. Substantial improvements in small field output factor measurement accuracy can be obtained when using microchambers and diodes by applying appropriately calculated correction factors to the detector measurements according to the proposed dosimetric formalism, and their routine use is therefore recommended.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Navier-Stokes computations of cavity aeroacoustics with suppression devices

Effectiveness of two devices to suppress the cavity acoustics was computationally investigated. Two dimensional, computational simulations were performed for the transonic, turbulent flows past a cavity, which was first equipped with a rear face ramp and then with a spoiler. The Reynolds-averaged, unsteady, compressible, full Navier-Stokes equations were solved time accurately by a second-order accurate, implicit, upwind, finite-volume method. The effect of turbulence was included through a Baldwin-Lomax model with modifications for the multiple-wall effects and for the highly vortical flow with a shear layer. The results included instantaneous and time-averaged flow properties, and time-series analyses of the pressure inside the cavity, which compared favorably with the available experimental data. These results were also contrasted with the computed aeroacoustics of the same cavity (length-to-depth ratio of 4.5), but without a device, to demonstrate the suppression effectiveness.

Baysal, Oktay↗

Potentiometric Sensors Based on Surface Molecular Imprinting: Detection of Cancer Biomarkers and Viruses

The continuing discovery of cancer biomarkers necessitates improved methods for their detection. Molecular imprinting using artificial materials provides an alternative to the detection of a wide range of substances. We applied surface molecular imprinting using self-assembled monolayers to design sensing elements for the detection of cancer biomarkers and other proteins. These elements consist of a gold-coated silicon chip onto which hydroxyl-terminated alkanethiol molecules and template biomolecule are co-adsorbed, where the thiol molecules are chemically bound to the metal substrate and self-assembled into highly ordered monolayers, the biomolecules can be removed, creating the foot-print cavities in the monolayer matrix for this kind of template molecules. Re-adsorption of the biomolecules to the sensing chip changes its potential, which can be measured potentiometrically. We applied this method to the detection of carcinoembryonic antigen (CEA) in both solutions of purified CEA and in the culture medium of a CEA-producing human colon cancer cell line. The CEA assay, validated also against a standard immunoassay, was both sensitive (detection range 2.5-250 ng/mL) and specific (no cross-reactivity with hemoglobin; no response by a non-imprinted sensor). Similar results were obtained for human amylase. In addition, we detected virions of poliovirus in a specific manner (no cross-reactivity to adenovirus, no response by a non-imprinted sensor). Our findings demonstrate the application of the principles of molecular imprinting to the development of a new method for the detection of protein cancer biomarkers and to protein-based macromolecular structures such as the capsid of a virion. This approach has the potential of generating a general assay methodology that could be highly sensitive, specific, simple and likely inexpensive.

59 BASIC BIOLOGICAL SCIENCES↗