Search NASA⌕ Search

SEARCH · Search NASA

Results for “code comparisons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Early User Test: BISON for Fission Gas Release Modeling

As a test to develop an understanding of the capabilities and input of the nuclear fuel performance code BISON, we modeled the fission gas release of the Oconee rod 15309 as there is benchmark data available for comparison. BISON has two fission gas models available, the Forsber-Massih model and the Simple Integrated Fission Gas Release and Swelling [sifgrs] model. Due to time constraints and availability of model parameters [we did not have all of the parameters for the sifgrs model already in hand] we only tested the Forsberg-Massih model. The Oconee rod test has been used in a number of benchmark studies including the integral assessment of FRAPCON 3.4. The Oconee Rod test is a 5-cycle test bundle with an average burnup of 50GWd/MTU. The FRAPCON assessment predicted that Oconee Rod15309 Test case would release 1.25% of all fission gas produced, while experimentally only 0.8% was released at EOL. Other studies using BISON with the sifgrs model have under predicted EOL fission gas release [FGR].

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic reactor modeling with applications to SPR and ZEDNA

A dynamic reactor model has been developed for pulse-type reactor applications. The model predicts reactor power, axial and radial fuel expansion, prompt and delayed neutron population, and prompt and delayed gamma population. All model predictions are made as a function of time. The model includes the reactivity effect of fuel expansion on a dynamic timescale as a feedback mechanism for reactor power. All inputs to the model are calculated from first principles, either directly by solving systems of equations, or indirectly from Monte Carlo N-Particle Transport Code (MCNP) derived results. The model does not include any empirical parameters that can be adjusted to match experimental data. Comparisons of model predictions to actual Sandia Pulse Reactor SPR-III pulses show very good agreement for a full range of pulse magnitudes. The model is also applied to Z-pinch externally driven neutron assembly (ZEDNA) type reactor designs to model both normal and off-normal ZEDNA operations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Final technical report

This final report covers the final year of the project. Reports from previous years were included in the group report for that year. The objective of this part of the project was to compare results from two large-scale, nonlinear plasma simulation codes based on magnetohydrodynamics, M3D and M3D-C1, for plasma edge instabilities. This is a difficult undertaking and the comparison was only partially successful because, while the MHD equations are standard, there are a number of valid MHD models of the plasma dissipation that make different approximations to their physics and the numerical implementation of a given model can be quite different depending on the way that the rest of the equations are solved. Large differences arise, and have major effects on the predicted plasma behavior, in the case of the greatest interest to this project, the plasma edge region under conditions where the plasma edge instabilities are strongest and the background plasma changes abruptly from interior hot, dense conditions to an unconfined, cool, diffuse plasma outside the magnetic boundary surface. Experimental observations only partially measure the background plasma and there are many non-MHD processes that can have important effects (studied in the rest of the project). Comparisons for edge instabilities at very small amplitude, the so-called linear modes, had showed good agreement for a few interior plasma instabilities, but strong differences between the default models for the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of Numerical Tools for Calculating Reactivity Feedback in Sodium Fast Reactors Using SEFOR Experimental Data

The Southwest Experimental Fast Oxide Reactor (SEFOR) was an experimental sodium-cooled fast breeder reactor operated from 1969 to 1972 with experiments designed to measure Doppler reactivity feedback in a wide temperature range from around 350 °F to temperatures approaching the melting point of mixed oxide fuel of around 5000 °F, providing valuable data for code validations. Co-supported by the Department of Energy (DOE) Fast Reactor Program (FRP) and the DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, the SEFOR benchmark project focused on using the experimental data to validate numerical tools that are used in industry and academia to design and license sodium-cooled fast reactors (SFRs). By the end of FY-25, substantial progress was achieved in the SEFOR benchmark study. A variety of numerical tools commonly used for modeling SFRs were applied to develop models for SEFOR core configurations I-D, I-E, I-I, and I-J. These included Monte Carlo codes such as MCNP, Serpent, and Shift; deterministic codes such as the legacy Argonne Reactor Computation (ARC) suite and the high-fidelity NEAMS code Griffin; and the system analysis code SAS4A/SASSYS-1 (SAS). Using these models, both SEFOR zero-power experiments and power-ascending tests were successfully simulated. Comparisons were performed against experimental measurements of core criticalities, reflector worth, kinetics parameters (Λ/βeff), isothermal reactivity feedback (from 350 °F to 760 °F at zero power), and power-ascending reactivity feedback (as power increased from 0.4 MW to 17 MW). In general, these comparisons demonstrated very good agreement between numerical results and experimental data. In Fiscal Year 26 (FY-26), the SEFOR benchmark project will continue to address the modeling issues identified in FY-25. Effort will focus on the simulation of reactivity insertion transients in SEFOR core II using the ARC/SAS model. Future work will also focus on incorporating BISON into the SEFOR core modeling process to enable the first Multiphysics simulations of the isothermal tests based on the MOOSE framework.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Heavy flavour dynamics in event-by-event viscous hydrodynamic backgrounds

We investigate the effects of (2+1)d event-by-event fluctuating hydrodynamic backgrounds on the nuclear modification factor and momentum anisotropies of heavy-flavor mesons. Using the state-of-the-art D and B mesons modular simulation code (the so-called DAB-mod), updated recently with heavy-light quark coalescence, we perform a systematic comparison of different transport equations, including two energy loss models and a relativistic Langevin model with two drag parametrizations. We present the resulting D 0 meson R AA , v 2 and v 3 , using the multiparticle cumulant method, in Pb-Pb collisions at $\sqrt{s_{\rm NN}}=5.02$ and compare them to the latest experimental data. We investigate the $v_2\{4\}/v_2\{2\}$ ratio as a function of centrality for different initial conditions (MCKLN vs. Trento) and different system geometries and sizes (coming from Pb-Pb collisions at $\sqrt{s_{\rm NN}}=5.02$, spherical and prolate Xe-Xe collisions at $\sqrt{s_{\rm NN}}=5.44$ TeV).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Single Synonymous Variant (c.354G>A [p.P118P]) in ADAMTS13 Confers Enhanced Specific Activity

Synonymous variants within coding regions may influence protein expression and function. We have previously reported increased protein expression levels ex vivo (~120% in comparison to wild-type) from a synonymous polymorphism variant, c.354G>A [p.P118P], of the ADAMTS13 gene, encoding a plasma protease responsible for von Willebrand Factor (VWF) degradation. In the current study, we investigated the potential mechanism(s) behind the increased protein expression levels from this variant and its effect on ADAMTS13 physico-chemical properties. Cell-free assays showed enhanced translation of the c.354G>A variant and the analysis of codon usage characteristics suggested that introduction of the frequently used codon/codon pair(s) may have been potentially responsible for this effect. Limited proteolysis, however, showed no substantial influence of altered translation on protein conformation. Analysis of post-translational modifications also showed no notable differences but identified three previously unreported glycosylation markers. Despite these similarities, p.P118P variant unexpectedly showed higher specific activity. Structural analysis using modeled interactions indicated that subtle conformational changes arising from altered translation kinetics could affect interactions between an exosite of ADAMTS13 and VWF resulting in altered specific activity. This report highlights how a single synonymous nucleotide variation can impact cellular expression and specific activity in the absence of measurable impact on protein structure.

Hunt, Ryan↗

Distributed resonance self-shielding using the equivalence principle

This paper presents an extension of the equivalence principle to allow distributed resonance self-shielding in a multi-region fuel configuration. Rational expansion of fuel-to-fuel collision probability is applied in order to establish equivalence between the actual fuel configuration and a homogeneous mixture of hydrogen and resonant absorber, which is a commonly used model to calculate library tables of resonance integrals. The main steps in derivation are given along with the basic physics assumptions on which the presented approach relies. The method has been implemented in the lattice code WIMS-AECL and routinely used for calculation of CANDU-type reactor lattices. Its capabilities are illustrated by comparison of WIMS-AECL and MCNP results of {sup 238}U resonance capture in a CANDU lattice cell. In order to determine optimal rational expansion of fuel-to-fuel collision probability, the calculations were carried out by varying the number of rational terms from 1 to 6. The results show that 4 terms are sufficient. The further increase of the number of terms affects the computing time, while the impact on accuracy is negligible. To illustrate the convergence of the results, the fuel subdivision is gradually refined varying the number of fuel pin subdivisions from 1 to 32 equal-area annuli. The results show very good agreement with the reference MCNP calculation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a dynamic simulation mode in Serpent 2 Monte Carlo code

This paper presents a dynamic neutron transport mode, currently being implemented in the Serpent 2 Monte Carlo code for the purpose of simulating short reactivity transients with temperature feedback. The transport routine is introduced and validated by comparison to MCNP5 calculations. The method is also tested in combination with an internal temperature feedback module, which forms the inner part of a multi-physics coupling scheme in Serpent 2. The demo case for the coupled calculation is a reactivity-initiated accident (RIA) in PWR fuel. (authors)

97 MATHEMATICS AND COMPUTING↗

Thermal-hydraulic performance of a high-temperature zigzag-channel printed circuit heat exchanger - 18563

Advanced nuclear reactors, such as high-temperature gas-cooled reactors (HTGRs) from the Generation IV nuclear systems, are designed with the capability of delivering high-pressure, high-temperature helium to power conversion units for electricity generation and industrial plants for process heat applications. The efficiency of the electricity generation and process heat applications of HTGRs is critically dependent upon an intermediate heat exchanger (IHX), which is a key component in transferring thermal energy from the primary coolant to a secondary coolant. Printed circuit heat exchangers (PCHEs) are promising to be employed in HTGR designs due to their capability for high-temperature, high-pressure applications and compactness. In the current study, a laboratory-scale zigzag-channel PCHE was fabricated and its heat transfer and pressure drop characteristics were investigated experimentally in a high-temperature helium test facility (HTHF). A commercial computational fluid dynamics (CFD) code, STARCCM+, was used to simulate the thermal-hydraulic performance of the fabricated PCHE with a simplified geometry model. Comparisons showed some differences between experimental data available for the zigzag-channel PCHE and the numerical results. Local thermal-hydraulic performance analyses indicated that fully-developed flow conditions and periodic changes were not observed, which could be attributed to the temperature variations along the flow channels, resulting in large fluid property variations. In addition, the effects of sharp-edged or rounded zigzag channel geometry were numerically evaluated. The use of rounded corners at each bend of the channels is recommended since this method can reduce the pressure drop on both the hot and cold sides of the heat exchanger while maintaining similar heat transfer capabilities. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of the MCNPX-PoliMi Code to Design a Fast-Neutron Multiplicity Counter

Many safeguards measurement systems used at nuclear facilities, both domestically and internationally, rely on He-3 detectors and well established mathematical equations to interpret coincidence and multiplicity-type measurements for verifying quantities of special nuclear material. Due to resource shortages alternatives to these existing He-3 based systems are being sought. Work is also underway to broaden the capabilities of these types of measurement systems in order to improve current multiplicity analysis techniques. As a part of a Material Protection, Accounting, and Control Technology (MPACT) project within the U.S. Department of Energy's Fuel Cycle Technology Program we are designing a fast-neutron multiplicity counter with organic liquid scintillators to quantify important quantities such as plutonium mass. We are also examining the potential benefits of using fast-neutron detectors for multiplicity analysis of advanced fuels in comparison with He-3 detectors and testing the performance of such designs. The designs are being developed and optimized using the MCNPX-PoliMi transport code to study detector response. In the full paper, we will discuss validation measurements used to justify the use of the MCNPX-PoliMi code paired with the MPPost multiplicity routine to design a fast neutron multiplicity counter with liquid scintillators. This multiplicity counter will be designed with the end goal of safeguarding advanced nuclear fuels. With improved timing qualities associated with liquid scintillation detectors, we can design a system that is less limited by nuclear materials of high activities. Initial testing of the designed system with nuclear fuels will take place at Idaho National Laboratory in a later stage of this collaboration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupled full core neutron transport/CFD simulations of pressurized water reactors

Recently as part of the CASL project, a capability to perform 3D whole-core coupled neutron transport and computational fluid dynamics (CFD) calculations was demonstrated. This work uses the 2D/1D transport code DeCART and the commercial CFD code STAR-CCM+. It builds on previous CASL work demonstrating coupling for smaller spatial domains. The coupling methodology is described along with the problem simulated and results are presented for fresh hot full power conditions. An additional comparison is made to an equivalent model that uses lower order T/H feedback to assess the importance and cost of high fidelity feedback to the neutronics problem. A simulation of a quarter core Combustion Engineering (CE) PWR core was performed with the coupled codes using a Fixed Point Gauss-Seidel iteration technique. The total approximate calculation requirements are nearly 10,000 CPU hours and 1 TB of memory. The problem took 6 coupled iterations to converge. The CFD coupled model and low order T/H feedback model compared well for global solution parameters, with a difference in the critical boron concentration and average outlet temperature of 14 ppm B and 0.94 deg. C, respectively. Differences in the power distribution were more significant with maximum relative differences in the core-wide pin peaking factor (Fq) of 5.37% and average relative differences in flat flux region power of 11.54%. Future work will focus on analyzing problems more relevant to CASL using models with less approximations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Predicting deviations in ex-core detector response in Krsko NPP during an earthquake with Monte-Carlo neutron transport methods

To study the response of ex-core detectors during an earthquake, an approach using Monte Carlo code MCNP was developed. As a first step to predict the response of the ex-core detectors a detailed MCNP model of the Krsko reactor core was created. A detailed MCNP core model was used to calculate 3D power distributions inside the core. Calculated power distributions were verified by comparison to the CORD-2 calculations, which is currently used for core design calculation verification of the Krsko nuclear power plant. Due to the outside the core position of the neutron detectors, the hybrid code ADVANTG is used to generate weight windows to speed up neutron transport outside the reactor core. To be able to use ADVANTG, fixed neutron source had to be reconstructed from the criticality core calculation. It was found that the power range ex-core detector movement has a negligible effect on the value of the thermal neutron flux at the active part of the detector. However, the 5 cm radial movement of the intermediate-range detector leads to 7 % - 8 % change in thermal neutron flux within the active intermediate-range detector region. The analysis continued with the evaluation of the effect of core barrel movement on the ex-core detector response. It was determined that the 2 mm core barrel radial oscillation can lead to ∼ 4% change in thermal neutron flux within the active detector region. It was evaluated that reactor core movement inside the baffle can lead up to ∼ 1.9% and ∼ 1.3% deviation in power-range and intermediate-range detector signal respectively. Analysis showed that the mechanical movement of ex-core neutron detectors could not explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-203: Comparison of a Commercial MRI-Linear Accelerator Based Monte Carlo Dose Calculation Algorithm and Geant4

Purpose: An MRI-linear accelerator is currently being developed by the vendor Elekta™. The treatment planning system that will be used to model dose for this unit uses a Monte Carlo dose calculation algorithm, GPUMCD, that allows for the application of a magnetic field. We tested this radiation transport code against an independent Monte-Carlo toolkit Geant4 (v.4.10.01) both with and without the magnetic field applied. Methods: The setup comprised a 6 MeV mono-energetic photon beam emerging from a point source impinging on a homogeneous water phantom at 100 cm SSD. The comparisons were drawn from the percentage depth doses (PDD) for three different field sizes (1.5 x 1.5 cm{sup 2}, 5 x 5 cm{sup 2}, 10 x 10 cm{sup 2}) and dose profiles at various depths. A 1.5 T magnetic field was applied perpendicular to the direction of the beam. The transport thresholds were kept the same for both codes. Results: All of the normalized PDDs and profiles agreed within ± 1 %. In the presence of the magnetic field, PDDs rise more quickly reducing the depth of maximum dose. Near the beam exit point in the phantom a hot spot is created due to the electron return effect. This effect is more pronounced for the larger field sizes. Profiles selected parallel to the external field show no effect, however, the ones selected perpendicular to the direction of the applied magnetic field are shifted towards the direction of the Lorentz force applied by the magnetic field on the secondary electrons. It is observed that these profiles are not symmetric which indicates a lateral build up of the dose. Conclusion: There is a good general agreement between the PDDs/profiles calculated by both algorithms thus far. We are proceeding towards clinically relevant comparisons in a heterogeneous phantom for polyenergetic beams. Funding for this work has been provided by Elekta.

60 APPLIED LIFE SCIENCES↗

Quantitative Real-Time Fluoroscopy Analysis on Measurement of the Hepatic Arterial Flow During Transcatheter Arterial Chemoembolization of Hepatocellular Carcinoma: Comparison with Quantitative Digital Subtraction Angiography Analysis

PurposeTo quantify the arterial flow change during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) using digital subtraction angiography, quantitative color-coding analysis (d-QCA), and real-time subtraction fluoroscopy QCA (f-QCA).Materials and MethodsThis prospective study enrolled 20 consecutive patients with HCC who had undergone TACE via a subsegmental approach between February 2014 and April 2015. The TACE endpoint was a sluggish antegrade tumor-feeding arterial flow. d-QCA and f-QCA were used for determining the relative maximal density time (rT{sub max}) of the selected arteries. The rT{sub max} of the selected arteries was analyzed in d-QCA and f-QCA before and after TACE, and its correlation in both analyses was evaluated.ResultsThe pre- and post-TACE rT{sub max} of the embolized segmental artery in d-QCA and f-QCA were 1.59 ± 0.81 and 2.97 ± 1.80 s (P < 0.001) and 1.44 ± 0.52 and 2.28 ± 1.02 s (P < 0.01), respectively. The rT{sub max} of the proximal hepatic artery did not significantly change during TACE in d-QCA and f-QCA. The Spearman correlation coefficients of the pre- and post-TACE rT{sub max} of the embolized segmental artery between d-QCA and f-QCA were 0.46 (P < 0.05) and 0.80 (P < 0.001). Radiation doses in one series of d-QCA and f-QCA were 140.7 ± 51.5 milligray (mGy) and 2.5 ± 0.7 mGy, respectively.Conclusionsf-QCA can quantify arterial flow changes with a higher temporal resolution and lower radiation dose. Flow quantification of the embolized segmental artery using f-QCA and d-QCA is highly correlated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling the formation of Sedan Crater using the FLAG and HOSS codes

Numerical modeling of explosion crater formation requires accounting for complex physical processes. Numerical validation of explosion cratering is an important step in modeling and requires experimental data for comparison. Models using discrete elements and continuum models have both benefits and drawbacks to their approaches. In this work, we consider both an arbitrary Lagrangian–Eulerian (ALE) hydrocode and a finite discrete element method (FDEM) approach to modeling the formation of the Sedan crater, the largest human-made crater in the United States. The Sedan crater formed from an underground nuclear detonation in the Nevada desert as part of Project Plowshare. Our models show that the continuum approach of the hydrocode matched well compared to early test time prior to the mound rupture and subsequent fireball venting, when most of the alluvium exhibited fluid behavior. Our FDEM approach matched the final crater dimensions well, after material had settled back into the crater, when material strength and solid mechanics play key roles. Our work shows how leveraging the benefits of multiple numerical approaches can lead to better understanding of complex physical problems, especially problems with limited experimental data. By using a continuum approach to early-time hydrodynamics and an FDEM approach to later-time solid mechanics, we can better understand the different physical regimes of explosion crater formation.

36 MATERIALS SCIENCE↗

MULTI-PARAMETRIC STUDY OF RISING 3D BUOYANT FLUX TUBES IN AN ADIABATIC STRATIFICATION USING AMR

We study the buoyant rise of magnetic flux tubes embedded in an adiabatic stratification using two-and three-dimensional, magnetohydrodynamic simulations. We analyze the dependence of the tube evolution on the field line twist and on the curvature of the tube axis in different diffusion regimes. To be able to achieve a comparatively high spatial resolution we use the FLASH code, which has a built-in Adaptive Mesh Refinement (AMR) capability. Our 3D experiments reach Reynolds numbers that permit a reasonable comparison of the results with those of previous 2D simulations. When the experiments are run without AMR, hence with a comparatively large diffusivity, the amount of longitudinal magnetic flux retained inside the tube increases with the curvature of the tube axis. However, when a low-diffusion regime is reached by using the AMR algorithms, the magnetic twist is able to prevent the splitting of the magnetic loop into vortex tubes and the loop curvature does not play any significant role. We detect the generation of vorticity in the main body of the tube of opposite sign on the opposite sides of the apex. This is a consequence of the inhomogeneity of the azimuthal component of the field on the flux surfaces. The lift force associated with this global vorticity makes the flanks of the tube move away from their initial vertical plane in an antisymmetric fashion. The trajectories have an oscillatory motion superimposed, due to the shedding of vortex rolls to the wake, which creates a Von Karman street.

79 ASTRONOMY AND ASTROPHYSICS↗

A verification study of fatigue-based methods in API RP 1183 for estimating fatigue life of pipeline dents

Pipeline dents are mechanical damage caused by a third party in buried pipelines during construction or maintenance repair. Dents are recognized as a leading cause of pipeline failures for both liquid and gas transmission lines, and their assessment and management are critical to pipeline integrity. To meet the industry need, American Institute of Petroleum (API) in 2020 published a recommended practice (RP) 1183 – Assessment and Management of Pipeline Dents. This API code provides the pipeline industry “standard methods” for evaluating severity and fatigue life of pipeline dents with a single peak. This paper performed an initial verification study of fatigue-based methods prescribed in API RP 1183 for estimating fatigue life of pipeline dents. A brief review was first given to the dent fatigue-based methods, including three dent screening methods for estimating dent fatigue life in Sections 7.4.1, 7.4.2, and 7.4.3 of API 1183 and one dent assessment method for predicting fatigue life in Section 8.3.4. In order to verify these fatigue life prediction methods, a set of “standard examples” of dents provided in Annexes A.1 to A.5 of API RP 1183 were utilized in this study to calculate fatigue life, to determine restraint condition, and to evaluate both screening and assessment methods for single-peak dents. Through detailed calculations and comparisons, this study confirmed some specifications of API RP 1183, but also found some self-inconsistences and errors existing in this new API code. Furthermore, this includes the self-inconsistences between three screening methods and the self-inconsistence between the screening and assessment methods. On this basis, recommendations were made on how the operators should use API RP 1183, and what actions API should take to improve this code.

42 ENGINEERING↗

Comparison of Modeled to Measured Spectra using MCNP and GADRAS to Benchmark and Contrast Modeling Limitations

The desire to improve nuclear material detection through portal monitors and other low resolution detectors has led to interest in benchmarking the performance of radiation transport codes. These codes can be used to generate a variety and quantity of spectra that may be cost prohibitive to measure directly. Particular characteristics of typical detection scenarios were isolated to compare the performance of radiation transport codes to laboratory experiments. These benchmark experiments were performed to validate simulations in a number of key areas. These experiments included high areal density configurations in both one- and three-dimensional configurations. In addition, off-angle measurements were conducted to investigate the impact of detector response assumptions on complex geometries, for example where an unknown source is not physically collocated with an apparent hot spot. Furthermore, by examining both simple shielding and backscatter configurations, isolation of the scatter emanating from the object and environmental background scatter contributions to the spectra could be elucidated. A series of experiments were performed in which the order of shielding layers and the thickness were evaluated to examine the ability of the simulations to address these variables. Experiments with increasing thickness of polyethylene around a neutron source also allows for examinations of the ability of the transport simulations to properly model n,γ reactions. Finally, depleted uranium (DU) measurements have more complicated spectra than the cobalt-60 and consequently allow for investigations into the ability of transport simulations to model self-shielding. In each case, the results of the experiments were compared to MCNP simulations to judge the performance of the code, as was done previously with GADRAS 18.7.9 simulations [7]. All of the benchmark measurements were taken with a liquid nitrogen cooled 140% high purity germanium (HPGe) detector with a bismuth collimator that had the front tin filter removed. The measurement location and detector configuration were subsequently used for all experimental configurations. The remainder of this report details the experimental measurements, Section 2 and the MCNP model, Section 3. Comparisons between the experimental results and MCNP-generated spectra are performed, Section 4. Section 5 compares the results obtained with MCNP with the previously reported results obtained with GADRAS [2]. Finally, Section 6 presents the conclusions.

61 RADIATION PROTECTION AND DOSIMETRY↗