Source Nuclide Density First-Order and Second-Order Sensitivities in Monte Carlo Codes
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
NeuroCoreX is an open-source codebase that enables the implementation of brain-inspired, energy-efficient neuromorphic computing models on FPGA hardware. Designed to support real-time learning, all-to-all neural connectivity, and flexible network architectures, NeuroCoreX offers a hands-on, accessible platform for exploring biologically inspired models of neural computation. It empowers researchers, students, and developers to implement and experiment with adaptive systems—bringing the power of neuromorphic computing to a broader community through a low-cost, scalable, and reconfigurable framework.
This dataset contains data and code used for the paper "Carbon flux estimates are sensitive to data source: A comparison of field and lab temperature sensitivity data" [DOI COMING SOON]A large literature exists on mechanisms driving soil production of the greenhouse gases CO2 and CH4. Measurements of these gases’ fluxes are often performed using closed-chamber incubations in the laboratory or in situ, i.e., in the field. Although it is common knowledge that measurements obtained through field studies vs. laboratory incubations can diverge because of the vastly different conditions of these environments, few studies have systematically examined these patterns. It is crucial to understand the magnitude and reasons for any differences, as these data are used to parametrize and benchmark ecosystem- to global-scale models, which are then susceptible to the biases of the source data. Here, we specifically examine how greenhouse gas measurements may be influenced by whether the measurement/incubation was conducted in the field vs. laboratory, focusing on CO2 and CH4 measurements. We use Q10 of greenhouse gas flux (temperature sensitivity) for our analyses, because of the ubiquity of this metric in biological and Earth system sciences and its importance to many modeling frameworks. We predicted that laboratory measurements would be less variable, but also less representative of true field conditions. However, there was greater variability in the Q10 values calculated from lab-based measurements of CO2 fluxes, because lab experiments explore extremes rarely seen in situ, and reflect the physical and chemical disturbances occurring during sampling, transport, and incubation. Overall, respiration Q10 values were significantly greater in laboratory incubations (mean = 4.19) than field measurements (mean = 3.05), with strong influences of incubation temperature and climate region/biome. However, this was in part because field measurements typically represent total respiration (Rs), whereas lab incubations typically represent heterotrophic respiration (Rh), making direct comparisons difficult to interpret. Focusing only on Rh-derived Q10, these values showed almost identical distributions across laboratory (n = 1110) and field (n = 581) experiments, providing strong support for using the former as an experimental proxy for the latter, although we caution that geographic biases in the extant data make this conclusion tentative. Due to a smaller sample size of CH4 Q10 data, we were unable to perform a comparable robust analysis, but we expect similar interactions with soil temperature, moisture, and environmental/climatic variables. Our results here suggest the need for more concerted efforts to document and standardize these data, including sample and site metadata. This dataset contains a compressed (.zip) archive of the data and R scripts used for this manuscript. The dataset includes files in .csv format, which can be accessed and processed using MS Excel or R. This archive can also be accessed on GitHub at https://github.com/kaizadp/field_lab_q10 (DOI: 10.5281/zenodo.7106554).
The Pacific Northwest National Laboratory (PNNL) operates a number of multidisciplinary laboratory research facilities for the U. S. Department of Energy and has sampled air chemical emissions from some of these facilities since 1998. The primary purpose of this sampling is to obtain data to compare estimated release fractions to those used for emissions estimates, verifying that methods used to determine compliance with air regulations and permits conservatively predict actual emissions. Sampling is also used to identify and quantify the air toxics emitted during normal working hours and to compare these emissions to compliance limits established by regulatory agencies. Hundreds of samples have been taken from four different multi-purpose laboratories over a 10-year time period. Results from initial sampling campaigns were evaluated and reported by Woodruff, Benar, and McCarthy (2000) who summarized the compliance approach used by PNNL and described sampling and analytical measurements for the first sampling campaigns. Conclusions reported at this time were that none of the measurements of the target compounds exceeded an acceptable source impact level (ASIL) (Washington Administrative Code, Chapter 173-460) even using significant overestimation factors, and that an average release fraction calculated from the data provided reasonable validation of the factor used in compliance assessments. A statistical analysis of the full data set is being conducted to obtain a better understanding of releases from R&D facilities including uncertainties, confidence intervals, and the relationship of release concentrations to chemical inventories or processes. This is intended to be a more in-depth investigation of release fractions with possible development of predictor source term models that include chemical and process properties (e.g. vapor pressure, temperature). One aspect of this analysis is to determine if emissions are significantly different for separate R&D facilities or if there is a commonality so that the data can be analyzed as a single group. The data set from air chemical sampling from 1998 through 2007 was analyzed to identify the chemical signature from each laboratory and determine how this signature differed by sampling location. Sampling locations included stacks from each of the four research facilities and non-stack locations such as lobbies and corridors which represent background concentrations of the volatile organic carbon (VOC) compounds being measured. For this analysis, the chemical signature was defined as the detection proportion of the VOCs analyzed. A simple metric was developed to quantitatively compare the chemical detection proportions from different locations or groups of locations. This metric is useful in comparing the combination of chemicals that have been detected in stack sampling, but not in comparing relative concentrations of those chemicals.
We report the serendipitous discovery of HSC J142449−005322, a double source plane lens system in the Hyper Suprime-Cam Subaru Strategic Program. We dub the system Eye of Horus. The lens galaxy is a very massive early-type galaxy with stellar mass of ∼7×10{sup 11} M{sub ⊙} located at z{sub L}=0.795. The system exhibits two arcs/rings with clearly different colors, including several knots. We have performed spectroscopic follow-up observations of the system with FIRE on Magellan. The outer ring is confirmed at z{sub S2}=1.988 with multiple emission lines, while the inner arc and counterimage is confirmed at z{sub S1}=1.302. This makes it the first double source plane system with spectroscopic redshifts of both sources. Interestingly, redshifts of two of the knots embedded in the outer ring are found to be offset by Δz=0.002 from the other knots, suggesting that the outer ring consists of at least two distinct components in the source plane. We perform lens modeling with two independent codes and successfully reproduce the main features of the system. However, two of the lensed sources separated by ∼0.7 arcsec cannot be reproduced by a smooth potential, and the addition of substructure to the lens potential is required to reproduce them. Higher-resolution imaging of the system will help decipher the origin of this lensing feature and potentially detect the substructure.
Purpose: High dose-rate (HDR) brachytherapy is currently performed with {sup 192}Ir sources, and {sup 60}Co has returned recently into clinical use as a source for this kind of cancer treatment. Both radionuclides have mean photon energies high enough to require specific shielded treatment rooms. In recent years, {sup 169}Yb has been explored as an alternative for HDR-brachytherapy implants. Although it has mean photon energy lower than {sup 192}Ir, it still requires extensive shielding to deliver treatment. An alternative radionuclide for brachytherapy is {sup 170}Tm (Z=69) because it has three physical properties adequate for clinical practice: (a) 128.6 day half-life, (b) high specific activity, and (c) mean photon energy of 66.39 keV. The main drawback of this radionuclide is the low photon yield (six photons per 100 electrons emitted). The purpose of this work is to study the dosimetric characteristics of this radionuclide for potential use in HDR-brachytherapy. Methods: The authors have assumed a theoretical {sup 170}Tm cylindrical source encapsulated with stainless steel and typical dimensions taken from the currently available HDR {sup 192}Ir brachytherapy sources. The dose-rate distribution was calculated for this source using the GEANT4 Monte Carlo (MC) code considering both photon and electron {sup 170}Tm spectra. The AAPM TG-43 U1 brachytherapy dosimetry parameters were derived. To study general properties of {sup 170}Tm encapsulated sources, spherical sources encapsulated with stainless steel and platinum were also studied. Moreover, the influence of small variations in the active core and capsule dimensions on the dosimetric characteristics was assessed. Treatment times required for a {sup 170}Tm source were compared to those for {sup 192}Ir and {sup 169}Yb for the same contained activity. Results: Due to the energetic beta spectrum and the large electron yield, the bremsstrahlung contribution to the dose was of the same order of magnitude as from the emitted gammas and characteristic x rays. Moreover, the electron spectrum contribution to the dose was significant up to 4 mm from the source center compared to the photon contribution. The dose-rate constant {Lambda} of the cylindrical source was 1.23 cGy h{sup -1} U{sup -1}. The behavior of the radial dose function showed promise for applications in brachytherapy. Due to the electron spectrum, the anisotropy was large for r<6 mm. Variations in manufacturing tolerances did not significantly influence the final dosimetry data when expressed in cGy h{sup -1} U{sup -1}. For typical capsule dimensions, maximum reference dose rates of about 0.2, 10, and 2 Gy min{sup -1} would then be obtained for {sup 170}Tm, {sup 192}Ir, and {sup 169}Yb, respectively, resulting in treatment times greater than those for HDR {sup 192}Ir brachytherapy. Conclusions: The dosimetric characteristics of source designs exploiting the low photon energy of {sup 170}Tm were studied for potential application in HDR-brachytherapy. Dose-rate distributions were obtained for cylindrical and simplified spherical {sup 170}Tm source designs (stainless steel and platinum capsule materials) using MC calculations. Despite the high activity of {sup 170}Tm, calculated treatment times were much longer than for {sup 192}Ir.
SAND2025-03757O Prime VI is a distribution-of-disease outbreak model calibration code based on variational inference. It accompanies a publication for submission to Statistics in Medicine journal, and the code will be maintained for open-source use on Sandia's GitLab. The software provides methods for calibrating an epidemiological model to measured case-count data for a multitude of correlated spatial regions. The code solves a Bayesian inverse problem for model calibration where the posterior over-model parameters are approximated through a custom implementation of variational inference. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.
The study of x-ray induced rapid heating and the resulting material responses - (thermomechanical shock (TMS) and thermo-structural response (TSR)) - is important to our understanding of material behavior in extreme environments. A series of high conversion efficiency (XRCE) x-ray sources have been developed for the NIF laser facility ranging in fluence and spectral content. In conjunction with source development, we have developed a new XTRRA (X-ray Transport and Radiation Response Analysis) test cassette to hold a set of samples, each at equal distance from target chamber center (TCC) where the x-ray source is placed. Design and performance details of the x-ray sources is discussed elsewhere. Here, we describe the development and use of this TMS XTRRA test cassette. The XTRRA test cassette is a snout mounted on a NIF Diagnostic Instrument Manipulator (DIM) designed to position six samples equidistant from the x-ray source to assure uniform irradiation of all samples. Photon Displacement interferometry (PDI) is used to measure the displacement of the rear surface of each sample resulting from x-ray exposure on the front of the sample. This will help determine the x-ray generated impulse on the sample. The samples are retrieved from the snout after the shot for inspection and post-shot analysis including the measurement of sample ablated mass and engineering tests examining changes in the material structure. The data from experiments are compared to predictions from LLNL’s ASC codes and used to inform models implemented in these codes. Thus, XRCE x-ray sources with the XTRRA snout at the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory [1,2] provide the ability to expose a broad range of material samples directly to high x-ray fluence, measure shock transits, and recover the sample for further analysis post-shot.
The study of x-ray induced rapid heating and the resulting material responses - (thermomechanical shock (TMS) and thermo-structural response (TSR)) - is important to our understanding of material behavior in extreme environments. A series of high conversion efficiency (XRCE) x-ray sources have been developed for the NIF laser facility ranging in fluence and spectral content. In conjunction with source development, we have developed a new XTRRA (X-ray Transport and Radiation Response Analysis) test cassette to hold a set of samples, each at equal distance from target chamber center (TCC) where the x-ray source is placed. Design and performance details of the x-ray sources is discussed elsewhere. Here, we describe the development and use of this TMS XTRRA test cassette. The XTRRA test cassette is a snout mounted on a NIF Diagnostic Instrument Manipulator (DIM) designed to position six samples equidistant from the x-ray source to assure uniform irradiation of all samples. Photon Displacement interferometry (PDI) is used to measure the displacement of the rear surface of each sample resulting from x-ray exposure on the front of the sample. This will help determine the x-ray generated impulse on the sample. The samples are retrieved from the snout after the shot for inspection and post-shot analysis including the measurement of sample ablated mass and engineering tests examining changes in the material structure. The data from experiments are compared to predictions from LLNL’s ASC codes and used to inform models implemented in these codes. Thus, XRCE x-ray sources with the XTRRA snout at the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory provide the ability to expose a broad range of material samples directly to high x-ray fluence, measure shock transits, and recover the sample for further analysis post-shot.
The RESRAD-BUILD computer code models radionuclide release and transport in indoor environments and performs pathway analyses to evaluate the potential radiological dose and risk incurred by an individual who works or lives in a building contaminated with radioactive material or housing radioactively contaminated furniture or equipment. The code provides four geometries to characterize a radiation source: point, line, area, and volume, in which radionuclides are homogeneously distributed. Radionuclides contained in a source are considered to be released to the indoor air due to various processes including erosion (mechanically or weathering), diffusion (for tritium and radon in a volume source), or emanation (radon in a point, line, or area source). The release can proceed through different time phases with different rates. In RESRAD-BUILD Version 4.0, a dynamic ventilation model is implemented to simulate the fate and transport of source material particles and radionuclides after their releases. This dynamic ventilation model considers (1) air exchange between rooms in the building and between the rooms and the outdoor environment, (2) deposition from air to floor, (3) resuspension from the floor to the air, and (4) periodical vacuuming that reduces the floor deposition. The fate and transport modeling provides estimates of radionuclide concentrations in the source, in the air, and on the floor at different times, which are then integrated over the exposure duration for the calculation of radiation doses and cancer risks. A single run of the RESRAD-BUILD code can model a building with up to 9 rooms, 10 sources, and 10 receptors. The potential radiation dose and cancer risk incurred by each receptor are calculated for seven exposure pathways: (1) external radiation directly from the sources (accounting for shielding), (2) external radiation from radioactive particles deposited on the floors, (3) external radiation from airborne radionuclides, (4) inhalation of airborne radionuclides, (5) inhalation of radon and radon progenies, (6) inadvertent ingestion of radioactive particles directly from the source, and (7) ingestion of radioactive particles deposited on the floors. Various exposure scenarios can be modeled with RESRAD-BUILD, including but are not limited to, office worker, renovation worker, decontamination worker, building visitor, and resident. Both deterministic and probabilistic analyses can be performed to obtain results in both text reports and graphic displays.
SENSMG is a tool for calculating the first-order sensitivities of reaction-rate ratios, k eff , and α in critical problems and reaction-rate ratios, reaction rates, and leakage in fixed-source problems to multigroup cross sections, isotope densities, material mass densities, and interface locations using the PARTISN multigroup discrete-ordinates code by implementing Generalized Perturbation Theory. SENSMG can be used for one-dimensional spherical and slab (r) and two-dimensional cylindrical (r-z) geometries. For fixed-source (leakage) problems, SENSMG relies on the MISC and/or SOURCES4C codes to compute neutron source rate densities from spontaneous fission and (α,n) sources. SENSMG is a combination of Python and Fortran and was developed under Linux. This computer code abstract describes all user inputs, the input file, and output files. Furthermore, this computer code abstract describes how SENSMG can be modified to support different computer platforms, PARTISN versions, or cross-section availability. Several verification problems are presented in which SENSMG results are compared with MCNP6, SCALE6.2, and direct perturbations (central differences).
MCNP is a Monte Carlo radiation transport code that has been under development for over half a century. Over the last decade, the development team of a high-energy offshoot of MCNP, called MCNPX, has implemented several physics and algorithm improvements important for modeling galactic cosmic-ray (GCR) interactions with matter. In this presentation, we discuss the latest of these improvements, a new Cosmic-Source option, that has been implemented in MCNP6.
A new open source multi-GPU 2D flood model called TRITON is presented in this work. The model solves the 2D shallow water equations with source terms using a time-explicit first order upwind scheme based on an Augmented Roe's solver that incorporates a careful estimation of bed strengths and a local implicit formulation of friction terms. Here, the scheme is demonstrated to be first order accurate, robust and able to solve for flows under various conditions. TRITON is implemented such that the model effectively utilizes heterogeneous architectures, from single to multiple CPUs and GPUs. Different test cases are shown to illustrate the capabilities and performance of the model, showing promising runtimes for large spatial and temporal scales when leveraging the computer power of GPUs. Under this hardware configuration, communication and input/output subroutines may impact the scalability. The code is developed under an open source license and can be freely downloaded in https://code.ornl.gov/hydro/triton.
Argonne National Laboratory (ANL) of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have cooperated on the development, design, and construction of a neutron source facility. The facility was constructed at Kharkov, Ukraine and its commissioning process is underway. The facility has an electron accelerator driven subcritical assembly. The electron beam power is 100 kW using 100 MeV electrons. Tungsten or natural uranium is the target material for generating neutrons driving the subcritical assembly. The subcritical assembly is composed of WWR-M2 Russian fuel assemblies with U-235 enrichment of 19.7 wt%, surrounded by beryllium reflector assembles and graphite blocks. The water coolant operates at room temperature during normal operation, when the facility is operating at full power using 100-KW electron beam power. The passive safety features of the facility are discussed in in this study. Monte Carlo computer code MCNPX was utilized in the analyses with ENDF/B VII.0 nuclear data library.
The results of simulations of extragalactic propagation of ultra-high energy cosmic rays (UHECRs) have intrinsic uncertainties due to poorly known physical quantities and approximations used in the codes. We quantify the uncertainties in the simulated UHECR spectrum and composition due to different models of extragalactic background light (EBL), different photodisintegration setups, approximations concerning photopion production and the use of different simulation codes. We discuss the results for several representative source scenarios with proton, nitrogen or iron at injection. For this purpose we used SimProp and CRPropa, two publicly available codes for Monte Carlo simulations of UHECR propagation. CRPropa is a detailed and extensive simulation code, while SimProp aims to achieve acceptable results using a simpler code. We show that especially the choices for the EBL model and the photodisintegration setup can have a considerable impact on the simulated UHECR spectrum and composition.
This report describes different methodologies to calculate the effective neutron multiplication factor of subcritical assemblies by processing the neutron detector signals using MATLAB scripts. The subcritical assembly can be driven either by a spontaneous fission neutron source (e.g. californium) or by a neutron source generated from the interactions of accelerated particles with target materials. In the latter case, when the particle accelerator operates in a pulsed mode, the signals are typically stored into two files. One file contains the time when neutron reactions occur and the other contains the times when the neutron pulses start. In both files, the time is given by an integer representing the number of time bins since the start of the counting. These signal files are used to construct the neutron count distribution from a single neutron pulse. The built-in functions of MATLAB are used to calculate the effective neutron multiplication factor through the application of the prompt decay fitting or the area method to the neutron count distribution. If the subcritical assembly is driven by a spontaneous fission neutron source, then the effective multiplication factor can be evaluated either using the prompt neutron decay constant obtained from Rossi or Feynman distributions or the Modified Source Multiplication (MSM) method.
HFBTHO is a physics computer code that is used to model the structure of the nucleus. It is an implementation of the nuclear energy Density Functional Theory (DFT), where the energy of the nucleus is obtained by integration over space of some phenomenological energy density, which is itself a functional of the neutron and proton densities. In HFBTHO, the energy density derives either from the zero-range Dkyrme or the finite-range Gogny effective two-body interaction between nucleons. Nuclear superfluidity is treated at the Hartree-Fock-Bogoliubov (HFB) approximation, and axial-symmetry of the nuclear shape is assumed. This version is the 3rd release of the program; the two previous versions were published in Computer Physics Communications [1,2]. The previous version was released at LLNL under GPL 3 Open Source License and was given release code LLNL-CODE-573953.
Purpose: The formalism recommended by Task Group 60 (TG-60) of the American Association of Physicists in Medicine (AAPM) is applicable for {beta} sources. Radioactive biocompatible and biodegradable {sup 153}Sm glass seed without encapsulation is a {beta}{sup -} emitter radionuclide with a short half-life and delivers a high dose rate to the tumor in the millimeter range. This study presents the results of Monte Carlo calculations of the dosimetric parameters for the {sup 153}Sm brachytherapy source. Methods: Version 5 of the (MCNP) Monte Carlo radiation transport code was used to calculate two-dimensional dose distributions around the source. The dosimetric parameters of AAPM TG-60 recommendations including the reference dose rate, the radial dose function, the anisotropy function, and the one-dimensional anisotropy function were obtained. Results: The dose rate value at the reference point was estimated to be 9.21{+-}0.6 cGy h{sup -1} {mu}Ci{sup -1}. Due to the low energy beta emitted from {sup 153}Sm sources, the dose fall-off profile is sharper than the other beta emitter sources. The calculated dosimetric parameters in this study are compared to several beta and photon emitting seeds. Conclusions: The results show the advantage of the {sup 153}Sm source in comparison with the other sources because of the rapid dose fall-off of beta ray and high dose rate at the short distances of the seed. The results would be helpful in the development of the radioactive implants using {sup 153}Sm seeds for the brachytherapy treatment.