Search NASA⌕ Search

SEARCH · Search NASA

Results for “conditional”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

The Role of Lithium Conditioning in Achieving High Performance, Long Pulse H-mode Discharges in the NSTX and EAST Devices

In this paper, the role of lithium wall conditioning on the achievement of high performance, long pulse discharges in the National Spherical Torus Experiment (NSTX) and the Experimental Advanced Superconducting Tokamak (EAST) is documented. Common observations include recycling reduction and elimination of ELMs. In NSTX, lithium conditioning typically resulted in ELM-free operation with impurity accumulation, which was ameliorated e.g. with pulsed 3D fields to trigger controlled ELMs. Active lithium conditioning in EAST discharges has overcome this problem, producing an ELM-free Hmode with controlled density and impurities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Onboard power line conditioning system for an electric or hybrid vehicle

A power line quality conditioning system for a vehicle includes an onboard rechargeable direct current (DC) energy storage system and an onboard electrical system coupled to the energy storage system. The energy storage system provides DC energy to drive an electric traction motor of the vehicle. The electrical system operates in a charging mode such that alternating current (AC) energy from a power grid external to the vehicle is converted to DC energy to charge the DC energy storage system. The electrical system also operates in a vehicle-to-grid power conditioning mode such that DC energy from the DC energy storage system is converted to AC energy to condition an AC voltage of the power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MECHANICAL STRENGTH RESPONSES OF POLED LEAD ZIRCONATE TITANATE UNDER EXTREME ELECTRIC FIELD AND VARIOUS TEMPERATURE CONDITIONS

PZT (lead zirconate titanate), particularly PZT-5A, is used in a variety of critical actuation and sensing systems because of its high Curie temperature and large piezoelectric coefficients. However, PZT is susceptible to mechanical failure. The evaluation of the mechanical strength of the material under the target working conditions is very important. This study presents part of the recent experimental developments in mechanical testing and evaluation of PZT materials at Oak Ridge National Laboratory. Ball-on-ring and four-point bending testing setups were used, with modifications made to account for testing requirements from high-level electric field and elevated temperature. The poled PZT-5A or equivalent material was tested under various specimen and testing conditions. The parameters of the distribution of strengths (characteristic strength and Weibull modulus) are discussed in relation to the testing conditions. Fractographic results based on scanning electron microscopy are also presented and discussed. The related data can serve as input for the design of piezoceramic devices, not only those used in energy systems like fuel injectors in heavy-duty diesel engines, but also those used in structural health monitoring, energy harvesting, and other critical systems in aerospace and civil engineering.

electric field↗

Potential Alternative Lower Global Warming Refrigerants for Air Conditioning in Hot Climates

The earth continues to see record increase in temperatures and extreme weather conditions that is largely driven by anthropogenic emissions of warming gases such as carbon dioxide and other more potent greenhouse gases such as refrigerants. The cooperation of 188 countries in the Conference of the Parties in Paris 2015 (COP21) resulted in an agreement aimed to achieve a legally binding and universal agreement on climate, with the aim of keeping global warming below 2 C. A global phasedown of hydrofluorocarbons (HFCs) can prevent 0.5 C of warming by 2100. However, most of the countries in hot climates are considered as developing countries and as such are still using R-22 (a Hydrochlorofluorocarbon (HCFC)) as the baseline refrigerant and are currently undergoing a phase-out of R-22 which is controlled by current Montreal Protocol to R-410A and other HFC based refrigerants. These HFCs have significantly high Global Warming Potential (GWP) and might not perform as well as R-22 at high ambient temperature conditions. In this paper we present recent results on evaluating the performance of alternative lower GWP refrigerants for R-22 and R-410A for small residential mini-split air conditioners and large commercial packaged units. Results showed that several of the alternatives would provide adequate replacement for R-22 with minor system modification. For the R-410A system, results showed that some of the alternatives were almost drop-in ready with benefit in efficiency and/or capacity. One of the most promising alternatives for R-22 mini-split unit is propane (R-290) as it offers higher efficiency; however it requires compressor and some other minor system modification to maintain capacity and minimize flammability risk. Between the R-410A alternatives, R-32 appears to have a competitive advantage; however at the cost of higher compressor discharge temperature. With respect to the hydrofluoroolefin (HFO) blends, there existed a tradeoff in performance and system design. It was noticed that higher glide refrigerants benefited the most from operating in the larger packaged unit with an evaporator in a multi-row counter-cross configuration. This study suggests that there is a strong potential for using lower GWP refrigerants to design and operate more efficient air conditioning systems in hot climates.

Alternative Refrigerants↗

Experimental Study on Portable Air-Conditioning System with Enhanced PCM Condenser

A portable personal air-conditioning system with a vapor compression cycle (VCC), electrical battery, and thermal battery is an attractive option for localized cooling as compared with stationary air-conditioning systems. A phase change material (PCM) can be used for storing waste heat from the VCC condenser, thereby acting as a thermal battery. In the PCM condenser, copper tubes are submerged in the PCM container. Due to the low thermal conductivity of pure PCM, the overall heat transfer coefficient of the PCM condenser is limited resulting in high VCC condensing pressure and thus, low VCC coefficient of performance (COP). Therefore, it is necessary to improve VCC system performances by applying heat transfer augmentation in PCM. In this work, a portable air-conditioning system with heat transfer enhanced PCM that stores heat from condenser during VCC operation and is regenerated by a thermosyphon operation is proposed. The system also includes a receiver to address the charge difference between the thermosyphon and the VCC operation. The paper experimentally studies the effects of the following three types of enhanced PCM condensers on the system performance: (1) copper mesh enhanced PCM with helically coiled copper tube branches and large refrigerant distribution headers (CMPHX), (2) graphite matrix enhanced PCM with straight copper tube branches and small headers (GMPHX1), and (3) graphite matrix enhanced PCM with straight copper tube branches and large headers (GMPHX2). Results show that this system operates properly and effectively during both VCC and PCM regeneration operations. The system can provide four hours of continuous cooling, and the PCM can be fully regenerated after 7.4 hours by thermosyphon operation. The comparisons of three PCM condensers indicate that the system with GMPHX2 performs the best with the average VCC COP of 4.7. The VCC system with CMPHX has an average COP of 4.2, and GMPHX1 has an average COP of 3.1. GMPHX2 has the best heat transfer enhancement with an overall heat transfer coefficient of 632.1 W∙m-2∙K-1, which is more than twice of GMPHX1 and five times of CMPHX. Moreover, GMPHX2 can achieve more uniform refrigerant flows and PCM temperature distributions than GMPHX1. This leads to the higher utilization ratio of PCM latent heat. CMPHX is the second best but needs larger heat transfer surface area and inner volume as well as more refrigerant charge. In conclusion, the system design with GMPHX2 is recommended due to its small refrigerant charge, high VCC COP, and the use of good heat transfer enhancement material.

Qiao, Yiyuan↗

The importance of reference conditions in assessing effects of bioenergy wood pellets produced in the southeastern United States

Documenting reference conditions is essential when assessing the effects of industrial wood pellet production. Reference conditions describe what is expected to occur in the absence of pellet production. Forests in the southeastern United States (SE US) are under pressure from development and other disturbances. Thus, reference conditions need to consider the alternate fates of the biomass used for pellets and the role international pellet markets can play to support retention of land in forests and good forest management practices that reduce risks of pest outbreaks, wildfires, and other disturbances.

09 BIOMASS FUELS↗

HEP Software Foundation Community White Paper Working Group – Conditions Data

To produce the best physics results, high energy physics experiments require access to calibration and other non-event data during event data processing. These conditions data are typically stored in databases that provide versioning functionality, allowing physicists to make improvements while simultaneously guaranteeing the reproducibility of their results. With the increased complexity of modern experiments, and the evolution of computing models that demand large scale access to conditions data, the solutions for managing this access have evolved over time. In this white paper we give an overview of the conditions data access problem, present convergence on a common solution and present some considerations for the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Influence of Ink Formulation and Drying Conditions on Ionomer Distribution in High-Performance Roll-to-Roll-Coated Gas-Diffusion Electrodes

To enable mass production of fuel cell membrane electrode assemblies (MEAs) catalyst layers production will require continuous roll-to-roll (R2R) coating processes. Gas diffusion electrodes (GDEs) are advantageous for mass production because the catalyst layer can be directely coated on the microporous layer of the gas diffusion media without the need for a decal-transfer process. It is known that the water-to-alcohol ratio in the catalyst ink influences the interactions of the ionomer with the catalyst leading to different distributions of ionomer in spray-coated catalyst layers. It is also known that during drying of colloidal mixtures, like fuel cell inks, factors such as drying rate, particle size, and agglomeration influence how the materials distribute themselves throughout the thickness of the dired film. Thus far there have only been limited studies to understand how process conditions such as ink formulation and drying temperature influence the distribution of ionomer and catalyst coated using scalable methods. This understanding is especially important for GDEs since it is known that having a sufficient amount of ionomer at the catalyst layer-membrane interface is critical for high performance. In this study we have focused on determining how the ratio of water to 1-propanol in the catalyst ink ink and drying temperature influence the distribution of ionomer throughout the thickness of the catalyst layer. Using a combination of Kelvin probe and x-ray photoelectron spectroscopy we show that an ionomer-rich surface is promoted by a higher drying rate and a water-rich catalyst ink. In contrast, a 1-propanol catalyst ink leads to a lower concentration of ionomer on the top surface. Using x-ray computed tomography, we are able to characterize the ionomer distribution throughout the thickness of the layer. We find that, in addition to promoting an ionomer-rich top surface, water-rich inks lead to a more homogenous distribution of ionomer, whereas a 1-propanol-rich ink leads to a more irregular distribution. It is found that MEA performance is improved by selecting conditions and ink formulations that promote ionomer enrichment at the top surface to facilitate a good interface with the membrane. MEAs prepared with a 75 wt% water catalyst ink with a 0.9 I/C have equivalent performance to spray-coated GDEs. Critically, these R2R-coated GDEs do not need an additional ionomer overlayer like the spray-coated GDEs do, reducing the number of processing steps in a manufacturing setting. This work shows that with the appropriate selection of materials, ink formulation, and processing conditions gas-diffusion electrodes are a viable pathway for fuel cell manufacturing.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Systems and methods for randomized, packet-based power management of conditionally-controlled loads and bi-directional distributed energy storage systems

The present disclosure provides a distributed and anonymous approach to demand response of an electricity system. The approach conceptualizes energy consumption and production of distributed-energy resources (DERs) via discrete energy packets that are coordinated by a cyber computing entity that grants or denies energy packet requests from the DERs. The approach leverages a condition of a DER, which is particularly useful for (1) thermostatically-controlled loads, (2) non-thermostatic conditionally-controlled loads, and (3) bi-directional distributed energy storage systems. In a first aspect of the present approach, each DER independently requests the authority to switch on for a fixed amount of time (i.e., packet duration). The coordinator determines whether to grant or deny each request based electric grid and/or energy or power market conditions. In a second aspect, bi-directional DERs, such as distributed-energy storage systems (DESSs) are further able to request to supply energy to the grid.

Frolik, Jeff↗

Electrochemical corrosion under controlled redox conditions

A method for predicting corrosion rates of a material during service conditions is provided, the method having the steps of determining a first phase composition of the material; exposing the material to service conditions chemical environment; applying an electrical potential to the exposed material to represent the solution redox; identifying ranges of the applied potential that correspond to different corrosion behaviors of the material; quantifying current and surface electrical properties during corrosion; and determining a second phase composition of the material to identify corroded phases. Also provided is a method for determining radionuclide source terms, the method having the steps of supplying a multiphase metallic waste containing the radionuclides; immersing the waste in a solution representing repository chemistry conditions; and oxidizing the immersed waste for a period of time and at particular imposed voltages representing solution redox values to establish a steady current representing corrosion rate of the waste.

Gattu, Vineeth Kumar↗

Real-time Data Analytics for Condition Monitoring of Complex Industrial Systems

Modern industrial systems are now fitted with several sensors for condition monitoring. This is advantageous because these sensors can provide mass amounts of data that have the potential for aiding in tasks such as fault detection, diagnosis, and prognostics. However, the information valuable for performing these tasks is often clouded in noise and must be mined from high-dimensional data structures. Therefore, this dissertation presents a data analytics framework for performing these condition monitoring tasks using high-dimensional data. Demonstrations of this framework are detailed for challenges related to power generation systems in automobiles, power plants, and aircraft engines. These implementations leverage data collected from state-of-the-art, industry class test-rigs. Results indicate the ability of this framework to develop effective methodologies for condition monitoring of complex systems.

Peters, Benjamin↗

Apparatus and system for controlling power to an air conditioning compressor for a vehicle

A climate control system for vehicles includes an internal combustion engine that may be coupled to selectively power a first motor generator, and an air conditioning compressor that may be selectively powered by one or both of the first motor generator and a second motor generator, or by the internal combustion engine. The system may include a rechargeable battery, and a vehicle controller having a vehicle state circuit structured to determine a vehicle operating condition value and a state-of-charge value of the rechargeable battery, and a coupling determination circuit structured to provide an internal combustion engine-first motor generator coupling command in response to the vehicle operating condition value and the state-of-charge value. In response to the internal combustion engine-first motor generator coupling command being provided as coupled, the internal combustion engine may power the first motor generator.

Kumar, Mahesh Madurai↗

Di-, tri-, tetranuclear clusters and polymeric cadmium compounds: Syntheses, structures and fluorescent properties with various linking fashions and high stability of orotates under the condition of strong bases

Assembly reactions of orotic acid (H{sub 3}dtpc ) and CdCl{sub 2}.2.5H{sub 2}O or CdSO{sub 4}.8H{sub 2}O yielded four new cadmium compounds {l_brace}[Cd(H{sub 2}dtpc)(phen)(H{sub 2}O){sub 2}].(H{sub 2}dtpc).4H{sub 2}O{r_brace}{sub 2} (1: solution reaction, pH=4-5, in addition of phen), [Cd{sub 3}(dtpc){sub 2}(phen){sub 5}].13H{sub 2}O (2: hydrothermal reaction, initial pH=14, final pH=7.5), [Cd(Hdtpc)(H{sub 2}O){sub 3}]{sub 4} (3: solution reaction, initial pH=6.5, final pH=6.0), {l_brace}[Cd(Hdtpc)(phen)(H{sub 2}O)].H{sub 2}O{r_brace}{sub n} (4: hydrothermal reaction, initial pH=8; final pH=6.5), respectively. Compounds 1-4 have been characterized by IR, thermogravimetric analyses (TGA), photoluminescence analyses, single-crystal and powder X-ray diffraction (PXRD). Compound 1 is a binuclear, 2 is a trinuclear, 3 is a tetranuclear structure, and 4 possesses one-dimensional chain framework, respectively, in which the orotate ligands show seven different linking fashions in 1-4. The orotate ligands as trivalence anions are observed in the formation of orotate-compounds, in which the orotates show high stability under the extreme condition of strong basic solution, high temperature and pressure. - Graphical abstract: Assembly of orotic acid and Cd(II) salts result in four new compounds under different reaction conditions, the compounds possess strong photoluminescence emissions and high thermal stability. Highlights: > Four Cd-compounds were prepared from orotic acid under different crystallization systems. > The orotates as trivalence anions displayed high stability under extremely conditions. > The orotates displayed various connection modes in the compounds. > The strong photoluminescence emissions have been observed in the compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of a proteus lattice representative of a burnt and fresh fuel interface at power conditions in light water reactors

The research program LIFE (Large-scale Irradiated Fuel Experiment) between PSI and Swissnuclear has been started in 2006 to study the interaction between large sets of burnt and fresh fuel pins in conditions representative of power light water reactors. Reactor physics parameters such as flux ratios and reaction rate distributions ({sup 235}U and {sup 238}U fissions and {sup 238}U capture) are calculated to estimate an appropriate arrangement of burnt and fresh fuel pins within the central element of the test zone of the zero-power research reactor PROTEUS. The arrangement should minimize the number of burnt fuel pins to ease fuel handling and reduce costs, whilst guaranteeing that the neutron spectrum in both burnt and fresh fuel regions and at their interface is representative of a large uniform array of burnt and fresh pins in the same moderation conditions. First results are encouraging, showing that the burnt/fresh fuel interface is well represented with a 6 x 6 bundle of burnt pins. The second part of the project involves the use of TSUNAMI, CASMO-4E and DAKOTA to perform parametric and optimization studies on the PROTEUS lattice by varying its pitch (P) and fraction of D{sub 2}O in moderator (F{sub D2O}) to be as representative as possible of a power light water reactor core at hot full power conditions at beginning of cycle (BOC). The parameters P and F{sub D2O} that best represent a PWR at BOC are 1.36 cm and 5% respectively. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Challenges and Successes in Measuring Aerosol Concentrations at Prototypic Spray Conditions Encountered at the Hanford Waste Treatment and Immobilization Plant - 13327

To date, majority of the work done on measuring aerosol releases from failure of process piping was done using simple Newtonian fluids and small engineered-nozzles that do not accurately represent the fluids and breaches postulated during accident analysis at the Hanford Waste Treatment and Immobilization Plant (WTP). In addition, the majority of the work conducted in this area relies on in-spray measurements that neglect the effect of splatter and do not yield any information regarding aerosol generation rates from this additional mechanism. In order to estimate aerosol generation rates as well as reduce the uncertainties in estimating the aerosol release fractions over a broad range of breaches, fluid properties and operating conditions encountered at the WTP, the Pacific Northwest National Laboratory (PNNL) has designed, commissioned, and tested two experimental test stands. The first test stand, referred to as the large-scale test stand, was designed specifically to measure aerosol concentrations and release fractions under prototypic conditions of flow and pressure for a range of breaches postulated in the hazard analysis for 0.076 m (3-inch) process pipes. However, the size of the large-scale test stand, anticipated fluid loss during a breach, experimental risks, and costs associated with hazardous chemical simulant testing limited the large-scale test stand utility to water and a few non-hazardous physical simulants that did not fully span the particle size and rheological properties of the fluids encountered at the WTP. Overcoming these limitations and extending the range of simulants used, required designing and building a smaller test stand, which was installed and operated in a fume hood. This paper presents some of the features of both test stands, the experimental challenges encountered, and successes in measuring aerosol concentration in both test stands over a range of test conditions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results from Evaluation of Representative ASME AG-1 Section FK Radial Flow Dimple Pleated HEPA Filters Under Elevated Conditions - 12002

The American Society of Mechanical Engineers (ASME) has recently added Section FK establishing requirements for radial flow HEPA filters to the Code on Nuclear Air and Gas Treatment (AG-1). Section FK filters are expected to be a major element in the HEPA filtration systems across the US Department of Energy (DOE) complex. Radial flow filters have been used in Europe for some time, however a limited amount of performance evaluation data exists with respect to these new AG-1 Section FK units. In consultation with a technical working group, the Institute for Clean Energy Technology (ICET) at Mississippi State University (MSU)has evaluated a series of representative AG-1 Section FK dimple pleated radial flow HEPA filters. The effects of elevated relative humidity and temperature conditions on these filters are particularly concerning. Results from the evaluation of Section FK filters under ambient conditions have been presented at the 2011 waste management conference. Additions to the previous test stand to enable high temperature and high humidity testing, a review of the equipment used, the steps taken to characterize the new additions, and the filter test results are presented in this study. Test filters were evaluated at a volumetric flow rate of 56.6 m{sup 3}/min (2000 cfm) and were challenged under ambient conditions with Alumina, Al(OH){sub 3}, until reaching a differential pressure of 1 kPa (4 in. w.c.), at which time the filters were tested, unchallenged with aerosol, at 54 deg. C (130 deg. F) for approximately 1 hour. At the end of that hour water was sprayed near the heat source to maximize vaporization exposing the filter to an elevated relative humidity up to 95%. Collected data include differential pressure, temperature, relative humidity, and volumetric flow rate versus time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparative study of glow discharge wall conditioning using H{sub 2} and Ar-H{sub 2} gas mixture of ADITYA Tokamak vacuum vessel

Low temperature glow discharge wall conditioning (GDC) using H{sub 2} gas is effective in reduction of oxygen and carbon (low-Z) contain impurities on near surface region of vessel wall. The high retention of hydrogen in vessel wall/components due to long operation of H{sub 2} GDC increases hydrogen out-gassing during tokamak operation and affects the production of high temperature plasma. The hydrogen retention can be reduced using inert gas GDC by sputter cleaning for short duration. But in that case the out-gassing rate of inert gas increases, that again impairs the plasma performance. To overcome above problems, the GDC with hydrogen-inert gas mixture can be used for better removal of C and O surface contaminants and low hydrogen retention in surface. In ADITYA tokamak, H{sub 2}-GDC is carried out regularly after plasma operation, while the GDC with argon-hydrogen (Ar-H{sub 2}) mixture has been experimentally tested to observe the reduction of oxygen and carbon impurities along with low hydrogen retention. In Ar-H{sub 2} GDC, the reason being the formation of ArH{sup +} hydride ions, which has quite long life and more energy compared to H{sub 2}{sup +} ions formed in H{sub 2} GDC for breaking the bond of wall molecules. A systematic comparative study of H{sub 2} GDC and Ar-H{sub 2} Mixture GDC by changing the mixture ratio has been carried out in ADITYA tokamak. The relative levels of oxygen and carbon contain impurities have been measured using residual gas analyzer in both GDC's. We have observed a substantial reduction in oxygen and carbon impurities with a significant improvement in wall condition with Ar-H{sub 2} GDC compared to the H{sub 2} GDC. The effect of wall conditioning by Ar-H{sub 2} GDC on the performance of high temperature plasma operation will be presented in this paper. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Seismic and LOCA safety testing and analysis program for Westinghouse PWR fuel under end of life conditions

The NRC issued Information Notice - IN 2012-09 in June 2012 which challenges approved assumptions based on the beginning of life (BOL) conditions in seismic and LOCA analysis. Westinghouse manufactures a variety of PWR fuel designs, including 14*14, 15*15, 16*16 and 17*17 array, also different fuel lengths from 12 feet to 14 feet. The fuels are supplied to the cores designed by Westinghouse and Combustion Engineering, and other cores around world. To address IN 2012-09 efficiently and economically, Westinghouse and PWR Owner Groups launched a testing and analysis program funded by PWROG. The program planed testing and analysis matrices based on types of fuel designs. The testing plan includes grid crush tests, fuel assembly mechanical tests and flowing water damping tests. Applying modelling technique, the program will reduce the number of test and cost. The ultimate goal of the program is to generate fuel assembly EOL models for all fuel designs manufactured by Westinghouse and to be ready for any plant specific seismic and LOCA analysis to address NRC IN for EOL effect. The phase I of PWROG for EOL conditions has been completed and several conclusions are obtained. First, the gapped grids reduce grid dynamic stiffness, local impact stiffness and crush strength. Also, due to gapped grids, both the fuel assembly natural frequency and stiffness are reduced. Secondly, applying higher fuel assembly damping due to the flowing water effect can significantly reduce fuel assembly impact forces. However, during a seismic event the reactor coolant pumps may trip resulting in a coast-down. As such, reduced flow rates that occur during the pump coast-down must be considered. Thirdly, the analytical model representation of a reactor core adequately characterizes the core response under seismic and LOCA excitations. Static and dynamic structural test results of a fuel assembly compared with analytical predictions indicate that the fuel assembly lateral and axial structural behavior can be fully determined with finite element models. Fourthly, analyses for EOL fuel assemblies under seismic and LOCA loads demonstrate EOL effect and flowing water damping effect. With flowing water damping benefit, significant margin can be recovered for fuel assemblies with EOL conditions and under seismic loads.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗