Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Feasibility of Using Neural Network Models to Accelerate the Testing of Mechanical Systems

Verification testing is an important aspect of the design process for mechanical mechanisms, and full-scale, full-length life testing is typically used to qualify any new component for use in space. However, as the required life specification is increased, full-length life tests become more costly and lengthen the development time. At the NASA Lewis Research Center, we theorized that neural network systems may be able to model the operation of a mechanical device. If so, the resulting neural network models could simulate long-term mechanical testing with data from a short-term test. This combination of computer modeling and short-term mechanical testing could then be used to verify the reliability of mechanical systems, thereby eliminating the costs associated with long-term testing. Neural network models could also enable designers to predict the performance of mechanisms at the conceptual design stage by entering the critical parameters as input and running the model to predict performance. The purpose of this study was to assess the potential of using neural networks to predict the performance and life of mechanical systems. To do this, we generated a neural network system to model wear obtained from three accelerated testing devices: 1) A pin-on-disk tribometer; 2) A line-contact rub-shoe tribometer; 3) A four-ball tribometer.

Fusaro, Robert L.↗

Characterization and Comparison of Planar and Trench Silicon Carbide (SiC) Power MOSFETs

This paper presents a comprehensive evaluation and experimental comparison of silicon carbide power MOSFETs through double pulse test. First, a universal hardware platform is designed and developed to test power semiconductor devices with various device packages and measuring requirements. Using the developed platform, the static characteristics and switching performance of the two types of SiC MOSFETs (one planar and one trench type) are evaluated under different case temperatures from 25 oC to 175 oC. Based on the evaluation data, a comparison of both SiC MOSFETs is conducted in terms of their on-state resistance, switching loss, and temperature dependent behavior. It is found that the latest trench SiC MOSFETs present similar switching loss while much lower conduction loss compared to existing commercial planar SiC MOSFETs. Moreover, the trench devices show a nearly temperature independent switching loss, which is beneficial to suppress the potential thermal runaway issue under high temperature continuous operation.

double pulse test↗

Impact tests on rubber compression springs for airplane landing gears

The present report gives the results of tests which were made for the purpose of solving the problem of whether diagrams obtained from pressure tests could be conclusive for the determination of the safe impact coefficients. It is first established that the rubber rings adhere firmly to the compression surfaces during deformation. Suggestions are thus obtained for a constructive simplification of the rubber rings. The hysteresis phenomenon is ascribed to external and internal friction forces. A device for falling tests is then described with which the process of shock absorption with rubber rings was tested.

Hohenemser, K↗

Operation of SOI P-Channel Field Effect Transistors, CHT-PMOS30, under Extreme Temperatures

Electronic systems are required to operate under extreme temperatures in NASA planetary exploration and deep space missions. Electronics on-board spacecraft must also tolerate thermal cycling between extreme temperatures. Thermal management means are usually included in today s spacecraft systems to provide adequate temperature for proper operation of the electronics. These measures, which may include heating elements, heat pipes, radiators, etc., however add to the complexity in the design of the system, increases its cost and weight, and affects its performance and reliability. Electronic parts and circuits capable of withstanding and operating under extreme temperatures would reflect in improvement in system s efficiency, reducing cost, and improving overall reliability. Semiconductor chips based on silicon-on-insulator (SOI) technology are designed mainly for high temperature applications and find extensive use in terrestrial well-logging fields. Their inherent design offers advantages over silicon devices in terms of reduced leakage currents, less power consumption, faster switching speeds, and good radiation tolerance. Little is known, however, about their performance at cryogenic temperatures and under wide thermal swings. Experimental investigation on the operation of SOI, N-channel field effect transistors under wide temperature range was reported earlier [1]. This work examines the performance of P-channel devices of these SOI transistors. The electronic part investigated in this work comprised of a Cissoid s CHT-PMOS30, high temperature P-channel MOSFET (metal-oxide semiconductor field-effect transistor) device [2]. This high voltage, medium-power transistor is designed for geothermal well logging applications, aerospace and avionics, and automotive industry, and is specified for operation in the temperature range of -55 C to +225 C. Table I shows some specifications of this transistor [2]. The CHT-PMOS30 device was characterized at various temperatures over the range of -190 C to +225 C in terms of its voltage/current characteristic curves. The test temperatures included +22, -50, -100, -150, -175, -190, +50, +100, +150, +175, +200, and +225 C. Limited thermal cycling testing was also performed on the device. These tests consisted of subjecting the transistor to a total of twelve thermal cycles between -190 C and +225 C. A temperature rate of change of 10 C/min and a soak time at the test temperature of 10 minutes were used throughout this work. Post-cycling measurements were also performed at selected temperatures. In addition, re-start capability at extreme temperatures, i.e. power switched on while the device was soaking for a period of 20 minutes at the test temperatures of -190 C and +225 C, was investigated.

Patterson, Richard↗

DANTi: Detect and Avoid iN The Cockpit

Mid-air collision risk continues to be a concern for manned aircraft operations, especially near busy non-towered airports. The use of Detect and Avoid (DAA) technologies and draft standards developed for unmanned aircraft systems (UAS), either alone or in combination with other collision avoidance technologies, may be useful in mitigating this collision risk for manned aircraft. This paper describes a NASA research effort known as DANTi (DAA iN The Cockpit), including the initial development of the concept of use, a software prototype, and results from initial flight tests conducted with this prototype. The prototype used a single Automatic Dependent Surveillance - Broadcast (ADS-B) traffic sensor and the own aircraft's position, track, heading and air data information, along with NASA-developed DAA software to display traffic alerts and maneuver guidance to manned aircraft pilots on a portable tablet device. Initial flight tests with the prototype showed a successful DANTi proof-of-concept, but also demonstrated that the traffic separation parameter set specified in the RTCA SC-228 Phase I DAA MOPS may generate excessive false alerts during traffic pattern operations. Several parameter sets with smaller separation values were also tested in flight, one of which yielded more timely alerts for the maneuvers tested. Results from this study may further inform future DANTi efforts as well as Phase II DAA MOPS development.

Chamberlain, James↗

Design fabrication and installation of a yaw measuring device

The results of work performed in the development and testing of a yaw measuring device are summarized. A review of the yaw measurement method; and the techniques and hardware needed for its implementation are presented. A description and summary of the tests performed at the U.S. Bureau of Mines Bruceton facility are included. Conclusions are summarized and recommendations for a unit capable of operation in a mine environment are presented.

Source record↗

The Diagnostics of the External Plasma for the Plasma Rocket

The plasma rocket is located at NASA Johnson Space Center. To produce a thrust in space. an inert gas is ionized into a plasma and heated in the linear section of a tokamak fusion device to 1 x 10(exp 4) - 1.16 x 10(exp 6)K(p= 10(exp 10) - 10(exp 14)/cu cm ). The magnetic field used to contain the plasma has a magnitude of 2 - 10k Gauss. The plasma plume has a variable thrust and specific impulse. A high temperature retarding potential analyzer (RPA) is being developed to characterize the plasma in the plume and at the edge of the magnetically contained plasma. The RPA measures the energy and density of ions or electrons entering into its solid angle of collection. An oscilloscope displays the ion flux versus the collected current. All measurements are made relative to the facility ground. A RPA is being developed in a process which involves the investigation of several prototypes. The first prototype has been tested on a thermal plasma. The knowledge gained from its development and testing were applied to the development of a RPA for collimated plasma. The prototypes consist of four equally spaced grids and an ion collector. The outermost grid is a ground. The second grid acts as a bias to repel electrons. The third is a variable v voltage ion suppressor. Grid four (inner grid) acts to repel secondary electrons, being biased equal to the first. Knowledge gained during these two stages are being applied to the development of a high temperature RPA Testing of this device involves the determination of its output parameters. sensitivity, and responses to a wide range of energies and densities. Each grid will be tested individually by changing only its voltage and observing the output from the RPA. To verify that the RPA is providing proper output. it is compared to the output from a Langmuir or Faraday probe.

Karr, Gerald R.↗

Multiple degree-of-freedom force and moment measurement for static propulsion testing using magnetic suspension technology

Innovative Information Systems (IIS), Inc. is in the process of designing and fabricating a high bandwidth force and moment measuring device (i.e. the Magnetic Thruster Test Stand). This device will use active magnetic suspension to allow direct measurements of the forces and torques generated by the rocket engines of the missile under test. The principle of operation of the Magnetic Thruster Test Stand (MTTS) is based on the ability to perform very precise, high bandwidth force and position measurements on an object suspended in a magnetic field. This ability exists due to the fact that the digital servo control mechanism that performs the magnetic suspension uses high bandwidth (10 kHz) position data (via an eddy-current proximity sensor) to determine the amount of force required to maintain stable suspension at a particular point. This force is converted into required electromagnet coil current, which is then output to a current amplifier driving the coils. A discussion of how the coil current and magnetic gap distance (the distance between the electromagnet and the object being suspended) is used to determine the forces being applied from the suspended assembly is presented.

Stuart, Keith↗

Improved perceptual-motor performance measurement system

Battery of tests determines the primary dimensions of perceptual-motor performance. Eighteen basic measures range from simple tests to sophisticated electronic devices. Improved system has one unit for the subject containing test display and response elements, and one for the experimenter where test setups, programming, and scoring are accomplished.

Parker, J. F., Jr.↗

TPGITF user's manual

The primary purpose of TPG interface (TPGITF) software is to create test patterns, according to a mathematical model, for a real device. In order for the device actually to be tested or to be accurately simulated, a means is required to transform the TPGITF generated test into forms acceptable as input to logic test equipment or to a software logic simulator. The MACRODATA-200 Logic Test System and the LOGSIM logic simulator are the particular systems supported by the TPGITF software. A description is presented of the TPGITF software processor. It is assumed that the reader is familiar with the TPG, LOGSIM, and TOIL systems. Flow charts are given.

Pitts, E. R.↗

Next Generation Exercise Device (NGED): Advancing Exercise Capabilities for Future Space Missions Through Biomechanical Modeling

BACKGROUND As space exploration extends to long-duration missions on the Moon and Mars, maintaining astronaut health and fitness becomes increasingly critical. The Next Generation Exercise Device (NGED), developed and tested by the HumanWorks Lab in NASA Johnson Space Center's (JSC) Software, Robotics, and Simulation Division, aims to address this challenge through innovative approaches. This study presents the development and evaluation of an NGED system, focusing on its adaptability to various mission scenarios, including prospective use in a Lunar Pressurized Rover (LPR). Central to this project is the application of biomechanical modeling to optimize exercise efficacy and safety in microgravity and partial gravity environments. The project is a collaborative effort with the Human Health and Performance group at Johnson Space Center, ensuring a comprehensive approach to astronaut well-being that integrates biomechanical principles with practical exercise solutions. The NGED represents the next generation of exercise capabilities for missions in space, on the Moon and Mars, with a specific focus on applications such as the LPR. METHODS AND RESULTS Data collection for NGED development was conducted with two motor-driven Beyond Power Voltra I [1] systems and a custom test structure to allow placement of the cable-based devices on the ground, at shoulder height, and overhead. The collection was performed in JSC’s Prototype Immersive Technology (PIT) Lab, utilizing an OptiTrack motion capture system and AMTI force platform, to enable detailed biomechanical analysis via OpenSim [2,3]. Motion capture data were collected for three subjects representing different body types and statures. The marker set used was an enhanced version of the full-body Plug-in Gait marker set [4], with additional markers strategically placed for the primary objective of informing exercise volume requirements. Subjects performed a series of 17 exercises, carefully selected to engage various muscle groups, including novel spaceflight exercises such as skiing (ergometer style), lateral pulldowns, wood chops, triceps extensions, and flies, with load variations ranging from 10 to 90 pounds to maintain kinematic form. This comprehensive approach allowed for a thorough evaluation of the NGED's performance across a wide range of motions and loads. The biomechanical modeling and analysis were conducted using a modified OpenSim Full Body Rajagopal Model [4,5] and also scaled to the maximum and minimum anthropometry provided in NASA-STD-3001 [6]. Volumetric convex hulls were generated based on model marker trajectories and aggregated into geometric assemblies. These can be placed in models of vehicle designs to assess fit to protect for exercise as well as to adapt NGED exercise to fit available space. Preliminary findings from the collection indicate that the NGED prototype demonstrates significant adaptability across varying user anthropometrics and exercise types. The device showed consistent performance in load-bearing exercises, with subjects able to perform exercises effectively while maintaining proper biomechanical form. CONCLUSION NGED represents a forward-looking advancement in exercise capabilities for future space missions. In the future, this system can be used to capture valuable metrics (e.g., isometric mid-thigh pull for force output measurements, assessments of postural muscle strength, overall isometric strength). Its versatility in accommodating various exercises and user physiques, coupled with the ability to provide targeted biomechanical loading, makes it a promising approach for maintaining astronaut health during long-duration missions to the Moon and Mars. Future work will focus on refining the NGED based on initial biomechanical findings, leveraging the detailed insights provided by motion capture and analysis techniques. Particular emphasis will be placed on optimizing its use within the confined spaces of a LPR and other space habitats. This work contributes significantly to NASA's goals of supporting human health and performance in deep space exploration, paving the way for sustainable long-term presence beyond Low Earth Orbit through advanced, biomechanically-informed exercise solutions.

C Wang↗

Oak Ridge 25URC Tandem Accelerator 2008 SNEAP Lab Report

During FY 2008, the 25URC operated for slightly over 3,000 research hours. The radioactive species {sup 80}Ge and {sup 17,18}F accounted for 763 of these hours. This included an experiment using {sup 17}F which was only possible due to an improvement of a factor of 50 in beam intensity over our previous facility record. Twenty stable beam species were provided this year. Operation for the experimental program was at terminal potentials from 2.02 to 23.8 MV. Approximately 200 hours of conditioning were done to return the machine to operation after tank openings. There were six tank openings during the year: three scheduled for general maintenance and three unscheduled. Two of the unscheduled openings were required to correct shorting rod issues and the other was to reestablish communication with one of the major dead sections. On July 28, an event happened that caused all accelerators at the Holifield Radioactive Ion Beam Facility (HRIBF) to suspend operation. At approximately 8 AM on that Monday, during operations with approximately 12 {micro}A of 50-MeV protons on a uranium carbide target, delivering neutron-rich {sup 81}Zn beam to the new Low-energy Radioactive Ion Beam Spectroscopy Station (LeRIBSS), a radiological control technician (RCT) reported higher than normal radiation levels just outside the shield door to the IRIS1 vault (the room in which RIBs are produced at HRIBF). The measured dose rate equivalent was 4 mrem/hr. The presence of radiological contamination on the floor just outside the shield door was subsequently noted, as was the possible presence of airborne radioactivity. These observations were reported to facility management. Accelerators were put in standby immediately and the building evacuated. The event was subsequently declared a laboratory operational emergency. Parts of the building were cleared for reentry to collect belongings on Monday afternoon. The entire building was cleared for reoccupation on Tuesday morning after a detailed radiological survey found no contamination outside the shielded vaults. No decontamination was required. No individual received any detectable radiological dose as a result of this event. The 25URC tandem accelerator was given permission to resume operation with stable beams in early September, but radioactive ion production is still not allowed. Subsequent analysis indicated a release that consisted entirely of noble gasses (Xe and Kr isotopes). We believe we have identified two unrelated failures, one associated with the HVAC system and the other with the roughing system exhaust which accounts for both the escape of noble gasses into the IRIS1 vault and their migration outside the vault. An investigation team report is expected by October 24. At that time, corrective actions will be determined and the path to future radioactive ion beam production will be known. The break from operations allowed a few upgrades to be implemented. The most notable was the installation and commissioning of a SNICS ion source purchased from National Electrostatics Corporation (NEC). The SNICS replaced the old Alton/Aarhus source that we have used for many years. An ANU style gas cathode holder was purchased also but has not yet been implemented. The first beams have been produced by the source and the biggest problem encountered was reducing the beam for very low current experiments. A new power supply for the injection magnet was installed during this period also. Radioactive ion beam (RIB) development at the High Power Target Laboratory (HPTL) has been delayed this year while installing the platforms, conduits and equipment for the second Injector for Radioactive Ion Species (IRIS2) which is co-located with the HPTL facility. Therefore, the majority of development activities have been performed at the two off-line ion source test facilities (ISTF1 and ISTF2) and the On-Line Test Facility (OLTF). Both test facilities have been developing systems which will eventually be used with IRIS2. Two new tunable Ti:Sapphire lasers have been ordered for continuing development of an ion source based on laser ionization using all solid-state lasers. When these are delivered, we will have a complete laser system. The other ion source test facility is continuing development of a negative-ion cooler for beam purification using photodetachment. This process has been demonstrated to work well in three systems so far (removing Co from Ni, removing S from Cl, and removing O from F). The original ion cooler has been modified to allow for use on the IRIS2 platform. Testing of this modified device is starting now. The OLTF has been used to test new types of uranium carbide targets for the electron beam plasma source (which are used for neutron-rich RIB campaigns) and to test a novel ion source which may result in purified beams of radioactive strontium isotopes.

43 PARTICLE ACCELERATORS↗

Development of Modeling Approaches for Nuclear Thermal Propulsion Test Facilities

High efficiency of rocket propul-sion systems is essential for humanity to venture be-yond the moon. Nuclear Thermal Propulsion (NTP) is a promising alternative to conventional chemical rock-ets with relatively high thrust and twice the efficiency of the Space Shuttle Main Engine. NASA is in the pro-cess of developing a new NTP engine, and is evaluat-ing ground test facility concepts that allow for the thor-ough testing of NTP devices. NTP engine exhaust, hot gaseous hydrogen, is nominally expected to be free of radioactive byproducts from the nuclear reactor; how-ever, it has the potential to be contaminated due to off-nominal engine reactor performance. Several options are being investigated to mitigate this hazard potential with one option in particular that completely contains the engine exhaust during engine test operations. The exhaust products are subsequently disposed of between engine tests. For this concept (see Figure 1), oxygen is injected into the high-temperature hydrogen exhaust that reacts to produce steam, excess oxygen and any trace amounts of radioactive noble gases released by off-nominal NTP engine reactor performance. Water is injected to condense the potentially contaminated steam into water. This water and the gaseous oxygen (GO2) are subsequently passed to a containment area where the water and GO2 are separated into separate containment tanks.

Jones, Daniel R.↗

Digital image profilers for detecting faint sources which have bright companions, phase 2

A breadboard image profiling system developed for the first phase of this project demonstrated the potential for detecting extremely faint optical sources in the presence of light companions. Experimental data derived from laboratory testing of the device supports the theory that image profilers of this type may approach the theoretical limit imposed by photon statistics. The objective of Phase 2 of this program is the development of a ground-based multichannel image profiling system capable of detecting faint stellar objects slightly displaced from brighter stars. We have finalized the multichannel image profiling system and attempted three field tests.

Morris, Elena↗

Diamond dose rate detector testing at KURRI- A joint UK-Japan research project - 17126

Measurements of radiation dose rates in highly active environments, such as nuclear plant decommissioning or following a nuclear disaster, is challenging due to the extreme environments encountered and restricted access. Therefore, novel radiation detector technology is required to address these challenges. One such example of a radiation detection material is diamond, as it is able to withstand and measure high radiation intensities, is chemically inert and formable into extremely small, sensitive detectors. These detectors generate small currents when exposed to radiation, and if the radiation levels are high enough this can be measured. Testing of such detectors is not possible in routine laboratories due to the requirement to have high active radiation sources. However, through a new collaboration formed through the University of Bristol- Kyoto University bilateral symposia such facilities are accessible for UK researchers at Kyoto University Research Reactor Institute. This paper presents an overview of the collaborative research project, the accessible facilities for device manufacture and testing and some early results from radiation testing of diamond detectors at KURRI. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-G-204-08: Optimized Digital Radiographic Technique for Lost Surgical Devices/Needle Identification

Purpose: Small surgical devices and needles are used in many surgical procedures. Conventionally, an x-ray film is taken to identify missing devices/needles if post procedure count is incorrect. There is no data to indicate smallest surgical devices/needles that can be identified with digital radiography (DR), and its optimized acquisition technique. Methods: In this study, the DR equipment used is a Canon RadPro mobile with CXDI-70c wireless DR plate, and the same DR plate on a fixed Siemens Multix unit. Small surgical devices and needles tested include Rubber Shod, Bulldog, Fogarty Hydrogrip, and needles with sizes 3-0 C-T1 through 8-0 BV175-6. They are imaged with PMMA block phantoms with thickness of 2–8 inch, and an abdomen phantom. Various DR techniques are used. Images are reviewed on the portable x-ray acquisition display, a clinical workstation, and a diagnostic workstation. Results: all small surgical devices and needles are visible in portable DR images with 2–8 inch of PMMA. However, when they are imaged with the abdomen phantom plus 2 inch of PMMA, needles smaller than 9.3 mm length can not be visualized at the optimized technique of 81 kV and 16 mAs. There is no significant difference in visualization with various techniques, or between mobile and fixed radiography unit. However, there is noticeable difference in visualizing the smallest needle on a diagnostic reading workstation compared to the acquisition display on a portable x-ray unit. Conclusion: DR images should be reviewed on a diagnostic reading workstation. Using optimized DR techniques, the smallest needle that can be identified on all phantom studies is 9.3 mm. Sample DR images of various small surgical devices/needles available on diagnostic workstation for comparison may improve their identification. Further in vivo study is needed to confirm the optimized digital radiography technique for identification of lost small surgical devices and needles.

60 APPLIED LIFE SCIENCES↗

Optical to optical interface device

The development, fabrication, and testing of a preliminary model of an optical-to-optical (noncoherent-to-coherent) interface device for use in coherent optical parallel processing systems are described. The developed device demonstrates a capability for accepting as an input a scene illuminated by a noncoherent radiation source and providing as an output a coherent light beam spatially modulated to represent the original noncoherent scene. The converter device developed under this contract employs a Pockels readout optical modulator (PROM). This is a photosensitive electro-optic element which can sense and electrostatically store optical images. The stored images can be simultaneously or subsequently readout optically by utilizing the electrostatic storage pattern to control an electro-optic light modulating property of the PROM. The readout process is parallel as no scanning mechanism is required. The PROM provides the functions of optical image sensing, modulation, and storage in a single active material.

Oliver, D. S.↗

Performance characterization of a segmented anode arcjet thruster

A modular, 1 to 2 kW class arcjet thruster incorporating a segmented anode/nozzle was operated on a thrust stand to obtain performance characteristics of the device and further study its operating characteristics under a number of experimental conditions. The nozzle was composed of five axial conducting segments isolated from one another by boron nitride spacers. The electrical configuration allowed the current delivered to the arcjet to be collected at any combination of segments. Both the current collected by each segment, and the potential difference between the cathode and each segment were monitored throughout the test period. As in previous tests a similar device, current appeared to attach diffusely in the anode when all of the segments were allowed to conduct. Improvements to the device allowed long term (4 to 8 hour) operation at steady-state and operating characteristics were repeatable over extended periods. Performance characteristics indicated that the segmented anode reasonably simulates the behavior of solid anodes of similar geometry. Current distribution depended on flow rate as the arc attachment moved downstream in the nozzle with increases in the mass flow rate. The current level had little effect on current distribution on the anode segments. Thrust measurements indicated that the current distribution in the nozzle did not significantly affect performance of the device.

Curran, Francis M.↗