Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Issues And Options For Mirrors Of CXRS And H-alpha ITER Diagnostics

The present status of investigations on the first mirror (FM) problem is discussed on the basis of the last experimental results obtained in modern tokamaks and laboratory devices. Engineering solutions that are necessary for protection of Fms for CXRS and H-alpha diagnostics are considered. Future plans for R and D that has yet to be done are presented. Results of neutron irradiation and heating tests of multilayered dielectric mirrors are given briefly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SOFT-X RAY DIAGNOSTICS AND TREATMENTS FOR FUTURE REAL TIME APPLICATIONS

This paper offers a preliminary review of the present diagnostics and data analysis techniques in the domain of Soft X-ray (SXR) emissions of fusion magnetic plasmas, including a short description of the theoretical background as well. Particular attention is devoted to the wide use of SXR tomography and impurity transport simulation. In their actual form, these techniques are not adequate to future real time applications. For this goal a step forward in the diagnosing and analysis of SXR emissions is required. The following part of the paper is therefore dedicated to the discussion of these improvements. The first one is the SXR tomography optimized for real time applications, like that one developed at Tore Supra (Cadarache, France). Fast 2-D tomographic inversions using different techniques (regularisation of Minimum Fisher, Maximum entropy, Zernicke polynomial expansions), will be optimized to be performed in a few millisecond time scale, crucial for MHD analysis, mode detection and localisation. The other goal to be pursued is the energy resolved imaging, now possible with a gas Micro Pattern Gas Detector with pixel read-out, as recently demonstrated at FTU (Frascati, Italy) and at NSTX (Princeton NJ, US), together with an ad hoc modeling of SXR emissions, compatible with future real time applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time Magnetic Field Pitch Angle Estimation With a Motional Stark Effect Diagnostic Using Kalman Filtering

The real-time amplitude estimation of selective harmonics from an Avalanche Photo Diode (APD) signal of a Motion Stark Effect diagnostic is addressed using a Kalman filter. The proposed technique is shown to be much more robust and provide less noisy estimates than a lock-in amplifier scheme. In addition, the negative impact of Edge Localised Modes (ELMs) is minimized, reducing significantly the biasing in the amplitude estimation and ultimately allowing for the pitch angle estimation in the vicinity of the ELM. The inherent biasing in the amplitude estimation due to the 50Hz modulation in the NBI power grid is also easily circumvented with such a technique, rendering dispensable any further filtering of the data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Steady State Challenge for Soft X-Ray Diagnostics on Wendelstein 7-X Stellarator

The steady state operation of Wendelstein 7-X stellarator presently under construction in Greifswald poses special challenges to the diagnostics development [1, 2]. A critical issue is the heat load on plasma facing components ({approx}500 kW/m{sup 2}) over a long discharge time (up to 30 min), which leads to the necessity of active cooling. As result, the design of the 400 channel soft X-Ray Multi Camera Tomography System (XMCTS) [2, 3] has to cope with dark currents and amplifier drifts due to the heating of active components like photo diodes and in-vessel preamplifiers. In order to allow for a quantitative measurement of dynamic drifts and offsets, a shutter system and blind diodes are considered to compensate these effects. Another important issue is the large amount of data gathered by the XMCT system during long pulse discharges. A fast but less precise online reconstruction is planned, which will give information on the plasma shape and position on a human time scale. The two options under investigation are a Cormack-Inversion method and an approach based on neural networks [4]. Dependent on the available hardware, as much information as possible should be stored for more accurate offline-analysis. An intelligent way of marking interesting data is required. In case that the steady-state storage of all measured data is not feasible, at least this marked data will be stored in high time resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Admissible Crosstalk Limits in a Two Colour Interferometers for Plasma Density Diagnostics. A Reduction Algorithm

Mid Infrared (10,6 {mu}m CO{sub 2} laser lines) interferometers as a plasma density diagnostic must use two-colour systems with superposed interferometers beams at different wavelengths in order to cope with mechanical vibrations and drifts. They require a highly precise phase difference measurement where all sources of error must be reduced. One of these is the cross-talk between the signals which creates nonlinear spurious periodic mixing products. The reason may be either optical or electrical crosstalk both resulting in similar perturbations of the measurement. In the TJII interferometer a post-processing algorithm is used to reduce the crosstalk in the data. This post-processing procedure is not appropriate for very long pulses, as it is the case for in new tokamak (ITER) or stellarator (W7-X) projects. In both cases an on-line reduction process is required or--even better--the unwanted signal components must be reduced in the system itself CO{sub 2} laser interferometers which as the second wavelength use the CO laser line (5,3 {mu}m), may apply a single common detector sensitive to both wavelengths and separate the corresponding IF signals by appropriate bandpass filters. This reduces complexity of the optical arrangement and avoids a possible source of vibration induced phase noise as both signals share the same beam path. To avoid cross talk in this arrangement filtering must be appropriate. In this paper we present calculations to define the limits of crosstalk for a desired plasma density precision. A crosstalk reduction algorithm has been developed and is applied to experimental results from TJ-II pulses. Results from a single detector arrangement as under investigation for the CO{sub 2}/CO laser interferometer developed for W7-X are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved intensity of ArXXVII resonance line for plasma diagnostics during high pressure gas injection

Paper describes simulations of time-resolved intensity of ArXVII-lines during high pressure gas injection in tokamak. Model consists of two parts: MHD part and CR part. MHD part is based on energy balance equations with special attention to generation of fast electrons and radiation losses. Time-dependent CR part calculates the distribution of Ar0-ArXIX and population of the levels in plasma with opacity effect and diagnostic admixture before injection.The results of calculations of plasma parameters (n{sub e}, n{sub i}, T{sub e}, T{sub i}, radiation peak) are in good agreement with experiments on DIII-D. Calculated time-resolved intensity of w-line (ArXVII) shows high sensitivity to plasma parameters during injection. Presented approach might become an efficient way to understand physics of gas penetration and dissipation of plasma energy within gas injection. Experiment might be carried out using X-ray spectrometer for T{sub i} measurements from Doppler broadening.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Negative Ion Based Heating and Diagnostic Neutral Beams for ITER

To meet the requirements of the four operating and one start-up scenarios foreseen in the International Tokamak Experimental Reactor (ITER) a flexible heating mix will be required, which has to include a reliable contribution from neutral beams. The current baseline of ITER foresees 2 Heating Neutral Beam (HNB) systems based on negative ion technology, each operating at 1 MeV 40 A D{sup -} ions, and each capable of delivering up to 16.7 MW of D deg. to the ITER plasma. A 3rd HNB injector is foreseen as an upgrade option. In addition a dedicated Diagnostic Neutral Beam (DNB) injecting 100 keV 60 A of negative hydrogen ions will be available for charge exchange resonant spectroscopy (CXRS). The significant R and D effort necessary to meet the design requirements will be provided in the Neutral Beam Test Facility (NBTF), which is to be constructed in Padua, Italy. This paper gives an overview of the current status of the neutral beam (NB) systems and the chosen configuration. The ongoing integration effort into the ITER plant is highlighted and open interface issues are identified. It is shown how installation and maintenance logistics has influenced the design. ITER operating scenarios are briefly discussed, including start-up and commissioning. For example it is now envisaged to have a low current hydrogen phase of ITER operations, essentially for commissioning of the many auxiliary systems used on ITER. The low current limits the achievable plasma density, and hence the NB energy due to shine through limitations. Therefore a possible reconfiguration of the auxiliary heating systems is now being discussed. Other NB related issues identified by the ongoing design review process are emphasized and possible impact on the implementations of the HNB and DNB systems is indicated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unfolding core asymmetries with x-ray emission images in symmetry diagnostic experiments

A novel inversion technique is proposed to unfold core asymmetries at the source with x-ray emission images, which were obtained from imploded surrogate capsules in symmetry diagnostic experiments. The axisymmetrical core emission can be expanded as a Fourier series, with Legendre polynomials and spherical Bessel functions as bases concerned with polar angle and radius, respectively. A least-squares estimator is employed to obtain the unknown coefficients from its two-dimensional image data. The unfolded Legendre coefficients can be further used to test modeling of drive asymmetries in hohlraums. This technique is also demonstrated with a proof-of-principle experiment performed on the Shenguang II laser facility [L. Zunqi et al., Chin. J. Lasers B10, 6 (2001)].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heat flow diagnostics for helicon plasmas

We present experimental studies of power balance in an argon helicon discharge. An infrared camera measures the heating of the dielectric tube containing a helicon discharge based on measurement of temperature profiles of the tube surface before and after a rf pulse. Using this diagnostic, we have measured surface heating trends at a variety of operating conditions on two helicon systems: the 10 kW VASIMR VX-50 experiment and the University of Texas at Austin 1 kW helicon experiment. Power losses downstream from the antenna are measured using thermocouples and probes. The heating of the dielectric tube increases with decreasing magnetic fields, higher gas flow rates, and higher molecular mass of the gas. These preliminary results suggest that cross-field particle diffusion contributes a significant proportion of the energy flux to the wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multipoint Thomson scattering diagnostic for the Madison Symmetric Torus reversed-field pinch

The multipoint Thomson scattering diagnostic on the Madison Symmetric Torus (MST) is now fully operational with 21 spatial points, which cover the entire minor radius. Four full electron temperature profiles can be obtained during each MST discharge, with a variable delay between each profile. This system overcomes challenges that arise from the unique machine design, location, and plasma characteristics of MST. The machine design limits the maximum porthole diameter to 11.4 cm, requiring a compact, re-entrant, seven element lens for scattered light collection. Limited space near MST necessitates a long beam path for the two Nd:YAG lasers requiring a remote beam line adjustment system to suppress drift in the beam position due to thermal expansion of the building. Due to the remote location of the laser head, substantial design effort was put into the creation of a set of safety interlocks for the laser system. The dynamic nature of MST plasmas and the wide range of operating space require a versatile scattered light detection system consisting of filter polychromators with temperature controlled avalanche photodiode detectors. We also implement an insertable integrating sphere, which travels along the laser beam path through the vacuum vessel, for the alignment of both the fiber optics and the lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The NSTX fast-ion D-alpha diagnostic

A new diagnostic, aimed at energy-resolved measurements of the spatial and temporal dynamics of fast ions in NSTX plasmas, is described. It is based on active charge-exchange recombination spectroscopy. The fast-ion signal is inferred from light emitted in the wavelength range of the D{sub {alpha}} line by fast ions recombining with an injected neutral beam. Two complementary systems are operational. The first system, based on a spectrometer coupled to a charge coupled device detector, has 16 channels with space, time, and energy resolution of 5 cm, 10 ms, and 10 keV, respectively. The second system monitors the energy-integrated fast-ion signal on time scales of {approx}20 {mu}s at three different radii. Signals are measured by a multianode photomultiplier tube. For both systems, each channel includes two paired views, intercepting and missing the neutral beam for a direct subtraction of the background signal not associated with fast ions. Examples of signals from the 2008 NSTX run are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new fast-ion D{sub {alpha}} diagnostic for DIII-D

The fast-ion D{sub {alpha}} (FIDA) technique is a charge-exchange recombination spectroscopy measurement that exploits the large Doppler shift of Balmer-alpha light from energetic hydrogenic atoms to infer the fast-ion density. Operational experience with the first dedicated FIDA diagnostic on DIII-D is guiding the design of the second-generation instrument. In the first instrument, dynamic changes in background light associated with plasma instabilities usually dominate measurement uncertainties. Accordingly, the design of the new instrument minimizes scattering of cold D{sub {alpha}} light while monitoring its level. The first instrument uses a vertical view to avoid bright interference from the injected-neutral beams. The sightline of the new instrument includes a toroidal component but only measures blueshifted fast-ion light that is Doppler shifted away from the redshifted light of the injected neutrals. The new views are more sensitive to fast ions that circulate in the direction of the plasma current and less sensitive to the trapped-ion and countercirculating populations. Details of the design criteria and solutions are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Forward modeling of JET polarimetry diagnostic

An analytical Bayesian inversion of the JET interferometry line integrated densities into density profiles and associated uncertainty information, is demonstrated. These are used, with a detailed model of plasma polarimetry, to predict the rotation and ellipticity for the JET polarimeter. This includes the lateral channels, for over 45,000 time points over 1313 JET pulses. Good agreement with measured values is shown for a number of channels. For the remaining channels, the requirement of a more detailed model of the diagnostic is demonstrated. A commonly used approximation for the Cotton-Mouton effect on the lateral channels is also evaluated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new diagnostic of the plasma density profile near the edge transport barrier from measurements of the radial profile of the H{sub {alpha}} line intensity

An edge transport barrier is now one of the most important subjects of controlled fusion research. The edge transport barrier is located in the plasma region where hydrogen atoms readily penetrate, so the intensity of the H{sub {alpha}} (D{sub {alpha}}) line is high enough. A new diagnostic method uses the well-known property of hydrogen atoms that the ratio of the ionization rate S{sub i} to the excitation rate S{sub v} for the H{sub {alpha}} line is nearly constant over a wide range of plasma temperatures and densities. An expression has been derived that relates the radial profiles of the plasma density and H{sub {alpha}} intensity. The use of charge coupled device detectors makes it possible to measure the radial profile of H{sub {alpha}} line intensity with a resolution {approx}0.1 cm; a high intensity of the H{sub {alpha}} line ensures a high time resolution {approx}1 ms. A high resolution is thus achieved for the density profile calculated from the H{sub {alpha}} intensity profile. The method was tested when studying the plasma density profile in the region of edge transport barrier in the L-2M stellarator. It has been shown that the density gradient varies during the barrier formation and that a fine structure of the density profile correlates with a character of the plasma transport near resonance magnetic flux surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact, accurate description of diagnostic neutral beam propagation and attenuation in a high temperature plasma for charge exchange recombination spectroscopy analysis

Charge exchange recombination spectroscopy on Alcator C-Mod relies on the use of the diagnostic neutral beam injector as a source of neutral particles which penetrate deep into the plasma. It employs the emission resulting from the interaction of the beam atoms with fully ionized impurity ions. To interpret the emission from a given point in the plasma as the density of emitting impurity ions, the density of beam atoms must be known. Here, an analysis of beam propagation is described which yields the beam density profile throughout the beam trajectory from the neutral beam injector to the core of the plasma. The analysis includes the effects of beam formation, attenuation in the neutral gas surrounding the plasma, and attenuation in the plasma. In the course of this work, a numerical simulation and an analytical approximation for beam divergence are developed. The description is made sufficiently compact to yield accurate results in a time consistent with between-shot analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A pulse-burst laser system for a high-repetition-rate Thomson scattering diagnostic

A ''pulse-burst'' laser system is being constructed for addition to the Thomson scattering diagnostic on the Madison Symmetric Torus (MST) reversed-field pinch. This laser is designed to produce a burst of up to 200 approximately 1 J Q-switched pulses at repetition frequencies 5-250 kHz. This laser system will operate at 1064 nm and is a master oscillator, power amplifier. The master oscillator is a compact diode-pumped Nd:YVO{sub 4} laser, intermediate amplifier stages are flashlamp-pumped Nd:YAG, and final stages will be flashlamp-pumped Nd:glass (silicate). Variable pulse width drive (0.3-20 ms) of the flashlamps is accomplished by insulated-gate bipolar transistor switching of large electrolytic capacitor banks. The burst train of laser pulses will enable the study of electron temperature (T{sub e}) and electron density (n{sub e}) dynamics in a single MST shot, and with ensembling, will enable correlation of T{sub e} and n{sub e} fluctuations with other fluctuating quantities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗