Search NASA⌕ Search

SEARCH · Search NASA

Results for “digital computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Where Is the Provenance? Ethical Replicability and Reproducibility in GIScience and Its Critical Applications

As replicability and reproducibility (R&R) crises develop within emerging convergent inquiry, ethical use of provenance information is central to the establishment and preservation of trust in critical applications of GIScience and geospatial technologies. Today large volumes of geospatial data are generated at high velocity from satellite sensors and unmanned aircraft systems, citizen sensors, geolocation-based data services, global navigation satellite systems, and so on. The extensive use of these data for applications such as disaster and humanitarian response raises the issue of R&R from competing perspectives of location privacy and geospatial data quality. Although geospatial data can be integrated and linked with contextual information to identify individuals’ movements, steps taken to ensure privacy can complicate the multiuser development of high-quality geospatial workflows. Provenance information as digital records of historical (retrospective) and potential future (prospective) geospatial processes is often overlooked, misunderstood, or inadequately addressed. We explore the relationship between provenance information, location privacy, and geospatial data quality in the context of R&R with a focus on disaster analytics. Here, we argue that in the era of big data and deep learning, GIScientists and associated institutions bear greater responsibility both for geospatial workflow quality and for location privacy. Given vastly heterogenous computational landscapes, we provide practical recommendations for ethically driven provenance and R&R research and development within the GIScience community and beyond.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Latent Twins

Over the past decade, scientific machine learning has transformed the development of mathematical and computational frameworks for analyzing, modeling, and predicting complex systems. From inverse problems to numerical partial differential equations (PDEs), dynamical systems, and model reduction, these advances have pushed the boundaries of what can be simulated. Yet they have often progressed in parallel, with representation learning and algorithmic solution methods evolving largely as separate pipelines. With Latent Twins, we propose a unifying mathematical framework that creates a hidden surrogate in latent space for the underlying equations. Whereas digital twins mirror physical systems in the digital world, Latent Twins mirror mathematical systems in a learned latent space governed by operators. Through this lens, classical modeling, inversion, model reduction, and operator approximation all emerge as special cases of a single principle. We establish the fundamental approximation properties of Latent Twins for both ordinary differential equations (ODEs) and PDEs and demonstrate the framework across three representative settings: (i) canonical ODEs, capturing diverse dynamical regimes; (ii) a PDE benchmark using the shallow-water equations, contrasting Latent Twin simulations with deep operator network and forecasts with a four-dimensional variational method baseline; and (iii) a challenging real-data geopotential reanalysis dataset, reconstructing and forecasting from sparse, noisy observations. Latent Twins provide a compact, interpretable surrogate for solution operators that evaluate across arbitrary time gaps in a single-shot, while remaining compatible with scientific pipelines such as assimilation, control, and uncertainty quantification. Looking forward, this framework offers scalable, theory-grounded surrogates that bridge data-driven representation learning and classical scientific modeling across disciplines.

Latent Twins↗

The effect of averaging adjacent planes for artifact reduction in matrix inversion tomosynthesis

Purpose: Matrix inversion tomosynthesis (MITS) uses linear systems theory and knowledge of the imaging geometry to remove tomographic blur that is present in conventional backprojection tomosynthesis reconstructions, leaving in-plane detail rendered clearly. The use of partial-pixel interpolation during the backprojection process introduces imprecision in the MITS modeling of tomographic blur, and creates low-contrast artifacts in some MITS planes. This paper examines the use of MITS slabs, created by averaging several adjacent MITS planes, as a method for suppressing partial-pixel artifacts. Methods: Human chest tomosynthesis projection data, acquired as part of an IRB-approved pilot study, were used to generate MITS planes, three-plane MITS slabs (MITSa3), five-plane MITS slabs (MITSa5), and seven-plane MITS slabs (MITSa7). These were qualitatively examined for partial-pixel artifacts and the visibility of normal and abnormal anatomy. Additionally, small (5 mm) subtle pulmonary nodules were simulated and digitally superimposed upon human chest tomosynthesis projection images, and their visibility was qualitatively assessed in the different reconstruction techniques. Simulated images of a thin wire were used to generate modulation transfer function (MTF) and slice-sensitivity profile curves for the different MITS and MITS slab techniques, and these were examined for indications of partial-pixel artifacts and frequency response uniformity. Finally, mean-subtracted, exposure-normalized noise power spectra (ENNPS) estimates were computed and compared for MITS and MITS slab reconstructions, generated from 10 sets of tomosynthesis projection data of an acrylic slab. The simulated in-plane MTF response of each technique was also combined with the square root of the ENNPS estimate to yield stochastic signal-to-noise ratio (SNR) information about the different reconstruction techniques. Results: For scan angles of 20 Degree-Sign and 5 mm plane separation, seven MITS planes must be averaged to sufficiently remove partial-pixel artifacts. MITSa7 does appear to subtly reduce the contrast of high-frequency 'edge' information, but the removal of partial-pixel artifacts makes the appearance of low-contrast, fine-detail anatomy even more conspicuous in MITSa7 slices. MITSa7 also appears to render simulated subtle 5 mm pulmonary nodules with greater visibility than MITS alone, in both the open lung and regions overlying the mediastinum. Finally, the MITSa7 technique reduces stochastic image variance, though the in-plane stochastic SNR (for very thin objects which do not span multiple MITS planes) is only improved at spatial frequencies between 0.05 and 0.20 cycles/mm. Conclusions: The MITSa7 method is an improvement over traditional single-plane MITS for thoracic imaging and the pulmonary nodule detection task, and thus the authors plan to use the MITSa7 approach for all future MITS research at the authors' institution.

60 APPLIED LIFE SCIENCES↗

T2-weighted four dimensional magnetic resonance imaging with result-driven phase sorting

Purpose: T2-weighted MRI provides excellent tumor-to-tissue contrast for target volume delineation in radiation therapy treatment planning. This study aims at developing a novel T2-weighted retrospective four dimensional magnetic resonance imaging (4D-MRI) phase sorting technique for imaging organ/tumor respiratory motion. Methods: A 2D fast T2-weighted half-Fourier acquisition single-shot turbo spin-echo MR sequence was used for image acquisition of 4D-MRI, with a frame rate of 2–3 frames/s. Respiratory motion was measured using an external breathing monitoring device. A phase sorting method was developed to sort the images by their corresponding respiratory phases. Besides, a result-driven strategy was applied to effectively utilize redundant images in the case when multiple images were allocated to a bin. This strategy, selecting the image with minimal amplitude error, will generate the most representative 4D-MRI. Since we are using a different image acquisition mode for 4D imaging (the sequential image acquisition scheme) with the conventionally used cine or helical image acquisition scheme, the 4D dataset sufficient condition was not obviously and directly predictable. An important challenge of the proposed technique was to determine the number of repeated scans (N{sub R}) required to obtain sufficient phase information at each slice position. To tackle this challenge, the authors first conducted computer simulations using real-time position management respiratory signals of the 29 cancer patients under an IRB-approved retrospective study to derive the relationships between N{sub R} and the following factors: number of slices (N{sub S}), number of 4D-MRI respiratory bins (N{sub B}), and starting phase at image acquisition (P{sub 0}). To validate the authors’ technique, 4D-MRI acquisition and reconstruction were simulated on a 4D digital extended cardiac-torso (XCAT) human phantom using simulation derived parameters. Twelve healthy volunteers were involved in an IRB-approved study to investigate the feasibility of this technique. Results: 4D data acquisition completeness (C{sub p}) increases as NR increases in an inverse-exponential fashion (C{sub p} = 100 − 99 × exp(−0.18 × N{sub R}), when N{sub B} = 6, fitted using 29 patients’ data). The N{sub R} required for 4D-MRI reconstruction (defined as achieving 95% completeness, C{sub p} = 95%, N{sub R} = N{sub R,95}) is proportional to N{sub B} (N{sub R,95} ∼ 2.86 × N{sub B}, r = 1.0), but independent of N{sub S} and P{sub 0}. Simulated XCAT 4D-MRI showed a clear pattern of respiratory motion. Tumor motion trajectories measured on 4D-MRI were comparable to the average input signal, with a mean relative amplitude error of 2.7% ± 2.9%. Reconstructed 4D-MRI for healthy volunteers illustrated clear respiratory motion on three orthogonal planes, with minimal image artifacts. The artifacts were presumably caused by breathing irregularity and incompleteness of data acquisition (95% acquired only). The mean relative amplitude error between critical structure trajectory and average breathing curve for 12 healthy volunteers is 2.5 ± 0.3 mm in superior–inferior direction. Conclusions: A novel T2-weighted retrospective phase sorting 4D-MRI technique has been developed and successfully applied on digital phantom and healthy volunteers.

60 APPLIED LIFE SCIENCES↗

Measurement Uncertainty in One-of-a-kind Experiments

A golden standard in science is to repeat an experimental measurement multiple times and calculate the measured value with experimental uncertainty by following well developed statistical procedures. For various reasons – cost, technical difficulty, international treaties, ethics of dealing with human or animal subjects, ecology - many important experiments and observations can not be repeated. Astronomy, earthquakes, hurricanes produce data from one-of-a-kind events. When information is not available in any other way, it should not be dismissed as qualitative, anecdotal evidence only. Analyzed in a mathematically rigorous way, it produces quantitative experimental data. Analysis of data from one-of-a-kind event differs from analysis of repeated experiments’ data. For repeated experiments, the experimental error includes a range of true values generated by repetitions of the experiment, and measurement uncertainty caused by detectors. They are independent. Repetitions of any experiment, as similar as achievable, always have built-in differences resulting in a range of the true values rather than in a single value. Measurement uncertainty depends on the measurement system only. Digital measurements have very small uncertainty, frequently smaller than the range of true experimental values resulting from built-in differences in the experiment repetitions. When data from one–of–a kind experiment are analyzed, only the measurement uncertainty can be reported.

42 ENGINEERING↗

Using Information Automation and Human Technology Integration to Implement Integrated Operations for Nuclear

The purpose of the research effort described in this report is to develop and demonstrate an approach to the design and implementation of advanced, automated systems intended to increase operational efficiencies at nuclear power plants. In particular, we describe methods for considering human-technology integration (HTI) issues throughout the various phases of system design, test, and implementation and how these considerations help promote effective design. This research project will develop planning tools and comprehensive guidance on how HTI principles and methods, in combination with information automation technologies, can enable effective data integration and coordination for full nuclear plant modernization. Specifically, this research project will develop an approach to automate the mapping of data from plant systems and processes to application needs, thereby significantly reducing the amount of human workload currently required for the execution of these tasks. In addition to developing an automated solution as a replacement for these tasks, this research will also analyze digitalization’s effectiveness in reducing operational costs of compliance related activities. Compliance activities are estimated to account for as much as 50% of operations and maintenance (i.e., non-fuel and non-capital) costs of plant operation.

97 MATHEMATICS AND COMPUTING↗

An operation verification strategy against network attack of DCS in nuclear power plant - 323

Digital Instrumentation and control (I and C) system serves as the 'senses and nervous system' of a nuclear power plant (NPP). It plays an important role in the safe and economic operation in the NPPs. Digital I and C system has a series of advantages compared with analogue ones, but the introduction of the operation system platform, the application software, and the network communication structure are causing security risk to the power plant. Different kinds of procedures have already been adopted against these risks such as the communication isolation, but the security attacks still occur from time to time in the industrial fields around the world. This paper presents two computer security methods based on the thought of software verification and validation with step-by-step operation identification. First, three scenarios of security attack are proposed according to the structure of a distributed control system (DCS). Then a method with two network bypasses and a security computer are adopted to obtain the operation commands, the actuation signal, and the operation feedback in case of the first two scenarios by identifying the consistency of the obtained data. Furthermore, the method is optimized by combining the operation procedure and the camera shot to identify the anomaly of the information flow, thus to improve the effectiveness against the computer security issues. In the end, the influence and feasibility of this method is discussed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Estimating pediatric entrance skin dose from digital radiography examination using DICOM metadata: A quality assurance tool

Purpose: To develop an automated methodology to estimate patient examination dose in digital radiography (DR) imaging using DICOM metadata as a quality assurance (QA) tool. Methods: Patient examination and demographical information were gathered from metadata analysis of DICOM header data. The x-ray system radiation output (i.e., air KERMA) was characterized for all filter combinations used for patient examinations. Average patient thicknesses were measured for head, chest, abdomen, knees, and hands using volumetric images from CT. Backscatter factors (BSFs) were calculated from examination kVp. Patient entrance skin air KERMA (ESAK) was calculated by (1) looking up examination technique factors taken from DICOM header metadata (i.e., kVp and mA s) to derive an air KERMA (k{sub air}) value based on an x-ray characteristic radiation output curve; (2) scaling k{sub air} with a BSF value; and (3) correcting k{sub air} for patient thickness. Finally, patient entrance skin dose (ESD) was calculated by multiplying a mass–energy attenuation coefficient ratio by ESAK. Patient ESD calculations were computed for common DR examinations at our institution: dual view chest, anteroposterior (AP) abdomen, lateral (LAT) skull, dual view knee, and bone age (left hand only) examinations. Results: ESD was calculated for a total of 3794 patients; mean age was 11 ± 8 yr (range: 2 months to 55 yr). The mean ESD range was 0.19–0.42 mGy for dual view chest, 0.28–1.2 mGy for AP abdomen, 0.18–0.65 mGy for LAT view skull, 0.15–0.63 mGy for dual view knee, and 0.10–0.12 mGy for bone age (left hand) examinations. Conclusions: A methodology combining DICOM header metadata and basic x-ray tube characterization curves was demonstrated. In a regulatory era where patient dose reporting has become increasingly in demand, this methodology will allow a knowledgeable user the means to establish an automatable dose reporting program for DR and perform patient dose related QA testing for digital x-ray imaging.

60 APPLIED LIFE SCIENCES↗

Control And Optimization Modular Modeling Application For Nuclear Deployment

The purpose of the COMMAND code is to provide a flexible, scalable tool for use in developing, integrating, and testing the technologies necessary for achieving autonomous operations of advanced nuclear reactors. The code enables users to efficiently implement custom simulations and experiments by combining key methods from different software modules. These modules are focused on: modeling and simulation tools, such as nuclear simulation tools used for high-fidelity modeling (e.g., Reactor Excursion and Leak Analysis Program [RELAP5-3D] and Monte Carlo N-Particle [MCNP]); machine learning and optimization tools (e.g., anomaly detection and data-driven modeling techniques); advanced control in its digital, high-performance, and supervisory control forms (e.g., proportional integral derivative (PID) control and model predictive control (MPC); and integration with hardware through industrial communication protocols. To ensure flexibility and scalability, COMMAND was designed to be both modular—the software “pieces” all inherit from generic building blocks and can be combined and connected to create complicated simulations—and high performing—designed for parallel processing, enabling simulations and experiments to take advantage of multi-core computers, servers, and nodes. The code is written in the Python programming language due to the language's popularity, active community, and open-source and cross-platform nature. Maintaining consistency with other simulation tools used within the nuclear energy community, users implement simulations and experiments through text input files, which define components, parameters, connections, etc., through lines of text. Given that COMMAND is written in Python, these input files are native Python scripts, and so use the standard Python structure and formatting. This also enables users to take advantage of Python's extensive package library to develop custom capabilities for their specific use cases.

Faber, Jacob [Idaho National Laboratory (INL), Ida↗

Computed Tomography Scanning and Petrophysical Measurements of the Lively Grove #1 Well Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from the Lively Grove #1 Well (API 121892494700), drilled near Marissa, Washington County, Illinois. Core from the well was obtained as part of the Illinois Storage Corridor’s Carbon Storage Assurance Facility Enterprise (CarbonSAFE) project (DE FE0031892). The primary impetus of this work was to capture a detailed digital representation of the core from the Lively Grove #1 Well. The collaboration between the U.S. Department of Energy’s (DOE) NETL and the Illinois State Geological Survey (ISGS) enables other research entities to access information about this potential carbon storage location and Cambro-Ordovician Storage Complex formations of the Illinois Basin. The resultant datasets are presented in this report and can be accessed from NETL’s Energy Data eXchange (EDX) online system. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with the medical CT scanner-acquired images. Imaging with the NETL medical CT scanner was performed on entire cores. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), gamma density, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for potential future analysis. Higher-resolution industrial and micro-CT images were acquired from selected zones along the depth of the core to visualize the structure in higher detail. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; with the resulting macro- and micro-descriptions relevant to many subsurface energy related examinations traditionally performed at NETL.

54 ENVIRONMENTAL SCIENCES↗

CDS Re Mix

CDS (Change Detection Systems) is a mechanism for rapid visual analysis using complex image alignment algorithms. CDS is controlled with a simple interface that has been designed for use for anyone that can operate a digital camera. A challenge of complex industrial systems like nuclear power plants is to accurately identify changes in systems, structures and components that may critically impact the operation of the facility. CDS can provide a means of early intervention before the issues evolve into safety and production challenges.

97 MATHEMATICS AND COMPUTING↗

Self Configuring Digital Twin for Optimizing E-Waste Recycling

Electronic waste recycling industry needs a decision support tool for optimizing their processes to become cost competitive. We developed a software called CMAT, Comprehensive Manufacturing Assessment Tool. The aim of CMAT is to provide the e-waste recycling companies with a fully customizable decision support framework that analyzes the optimal supply chain configurations. The software optimizes the logistics operations, helps to identify the best recycling process configuration, and generates valuable insights regarding the economic performance of different categories of e-waste. The ultimate purpose of the tool is to assist the users developing a digital twin of their processes and to provide insights on questions pertinent to the e-waste recycling industry including how to increase efficiency and reduce costs, energy consumption, and greenhouse gas emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A study of adhesive bonding in metal–metal, metal–CFRP, and CFRP–CFRP material combinations under shear deformation: Fracture morphologies and damage mechanisms

Safe design of adhesive joining in multi-materials in engineered structures requires the accumulation of numerous experimental data on the failure behavior of various adhesively-bonded material combinations under different loading conditions. The deep understanding of mechanical performance, fracturing morphologies, and main damage mechanisms is also quintessential for accelerating the development of proper physics-based and multi-scale models for assisting the design. Towards this goal, this work presents a comprehensive characterization of the failure behavior of adhesively-bonded metal–metal, metal–CFRP, and CFRP–CFRP material combinations under global shear deformation via single lap shear testing. Thanks to a synergistic combination of measurement methods by using Digital Imaging Correlation (DIC) and 3D optical profilometry, adhesive features on the adherend after failure were quantified and the main progressive damage mechanisms were identified. The characterization performed in this work provides quantitative data that contributes to a better understanding of shear failure in adhesive bonding across different bi-material combinations. Finally, the obtained results have practical implications, including the potential to enhance adhesive bonding design, identify failure causes in adhesive joints, and develop or validate computational models capable of capturing the observed behavior in various adhesively-bonded materials under global shear deformation.

36 MATERIALS SCIENCE↗

Improved proton computed tomography by dual modality image reconstruction

Purpose: Proton computed tomography (CT) is a promising image modality for improving the stopping power estimates and dose calculations for particle therapy. However, the finite range of about 33 cm of water of most commercial proton therapy systems limits the sites that can be scanned from a full 360° rotation. In this paper the authors propose a method to overcome the problem using a dual modality reconstruction (DMR) combining the proton data with a cone-beam x-ray prior. Methods: A Catphan 600 phantom was scanned using a cone beam x-ray CT scanner. A digital replica of the phantom was created in the Monte Carlo code Geant4 and a 360° proton CT scan was simulated, storing the entrance and exit position and momentum vector of every proton. Proton CT images were reconstructed using a varying number of angles from the scan. The proton CT images were reconstructed using a constrained nonlinear conjugate gradient algorithm, minimizing total variation and the x-ray CT prior while remaining consistent with the proton projection data. The proton histories were reconstructed along curved cubic-spline paths. Results: The spatial resolution of the cone beam CT prior was retained for the fully sampled case and the 90° interval case, with the MTF = 0.5 (modulation transfer function) ranging from 5.22 to 5.65 linepairs/cm. In the 45° interval case, the MTF = 0.5 dropped to 3.91 linepairs/cm For the fully sampled DMR, the maximal root mean square (RMS) error was 0.006 in units of relative stopping power. For the limited angle cases the maximal RMS error was 0.18, an almost five-fold improvement over the cone beam CT estimate. Conclusions: Dual modality reconstruction yields the high spatial resolution of cone beam x-ray CT while maintaining the improved stopping power estimation of proton CT. In the case of limited angles, the use of prior image proton CT greatly improves the resolution and stopping power estimate, but does not fully achieve the quality of a 360° proton CT scan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A HPC Theory-Guided Machine Learning Cyberinfrastructure for Communicating Hydrometeorological Data Across Scales

High-resolution predictions of hydrometeorological variables are critical for supporting hydropower generation decisions and flood control at hydroelectric power plants. Traditional climate and hydrologic models rely on the numerical simulation of detailed physical processes. Therefore, running these simulations is time-, labor-, and computation-intensive. Improving the spatial and temporal resolution in these modeling outputs could lead to cubic increases in both the simulation time and computational demands, rendering high-resolution hydrometeorological predictions expensive and impractical. Many past studies apply the super resolution (SR) technique to downscale climate models using deep learners. However, deep learners are deemed “black-boxes,” as their derivation processes from low-resolution outputs to high-resolution outputs are often hidden. Their results are difficult for domain scientists to interpret and validate. Thus, there is a need for an exploratory machine learning approach that can partially integrate domain-specific theory and knowledge into the data-driven mapping process between simulation outputs of different spatial scales. The domain-specific theory and knowledge can be incorporated into the data model through an inductive approach in which process-related environmental variables are used and analyzed as key drivers (i.e., environmental surrogates) to reflect the complex physical processes. Many of these variables, such as land use land cover, soil types, topography, digital elevation, air temperature, and various watershed characteristics, can be directly measured through sensors or remote sensing techniques. Additionally, SR applications that can downscale hydrological and hydrodynamics models to efficiently produce high-resolution (1 m) flood depth grids are still rare. Since the flood depth grid can be used to support critical decisions for flood control operation at hydroelectric power plants, it is crucial to enable an SR-based capability for interpolating high-resolution flood inundation maps.

13 HYDRO ENERGY↗

Comparison of maximal Rubidium-82 activities for myocardial blood flow quantification between digital and conventional PET systems

Background: PET-based myocardial blood flow (MBF) quantification can be inaccurate when using high tracer activities. Our aim was to derive the maximal Rubidium-82 activity for MBF assessment using a new digital PET system and compare the results with conventional analog systems. Methods: 1.8 GBq Rubidium-82 was injected into the cardiac insert of an anthropomorphic torso phantom. Data were acquired for 10 min using an Ingenuity TF (Philips Healthcare), Discovery 690 (D690, GE Healthcare), and digital PET prototype system (Philips Healthcare). The dynamic ranges, defined as the maximal measured activity in the reconstructed images deviating < 10% from the true present activity, were determined in all scans. Results: The dynamic ranges were 312 MBq for Ingenuity TF, 650 MBq for D690, and 654 MBq for digital PET prototype. Conclusions: The maximal Rb-82 activity for MBF assessment using digital PET prototype is higher than that for its analog counterpart (Ingenuity TF), but seems comparable to the D690.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extraction of Hydrological Proximity Measures from DEMs using Parallel Processing

Land surface topography is one of the most important terrain properties which impact hydrological, geomorphological, and ecological processes active on a landscape. In our previous efforts to develop a soil depth model based upon topographic and land cover variables, we extracted a set of hydrological proximity measures (HPMs) from a Digital Elevation Model (DEM) as potential explanatory variables for soil depth. These HPMs may also have other, more general modeling applicability in hydrology, geomorphology and ecology, and so are described here from a general perspective. The HPMs we derived are variations of the distance up to ridge points (cells with no incoming flow) and variations of the distance down to stream points (cells with a contributing area greater than a threshold), following the flow path. These HPMs were computed using the D-infinity flow model that apportions flow between adjacent neighbors based on the direction of steepest downward slope on the eight triangular facets constructed in a 3 x 3 grid cell window using the center cell and each pair of adjacent neighboring grid cells in turn. The D-infinity model typically results in multiple flow paths between 2 points on the topography, with the result that distances may be computed as the minimum, maximum or average of the individual flow paths. In addition, each of the HPMs, are calculated vertically, horizontally, and along the land surface. Previously, these HPMs were calculated using recursive serial algorithms which suffered from stack overflow problems when used to process large datasets, limiting the size of DEMs that could be analyzed using that method to approximately 7000 x 7000 cells. To overcome this limitation, we developed a message passing interface (MPI) parallel approach for calculating these HPMs. The parallel algorithms of the HPMs spatially partition the input grid into stripes which are each assigned to separate processes for computation. Each of those processes then uses a queue data structure to order the processing of cells so that each cell is visited only once and the cross-process communications that are a standard part of MPI are handled in an efficient manner. This parallel approach allows analysis of much larger DEMs as compared to the serial recursive algorithms. In this paper, we present the definitions of the HPMs, the serial and parallel algorithms used in their extraction and their potential applications in hydrology, geomorphology and ecology.

54 ENVIRONMENTAL SCIENCES↗

X-ray computed tomography-based porosity analysis: Algorithms and application for porous woody biomass

The properties of lignocellulosic biomass, such as bulk physical, thermal, and mechanical properties, as well as the mobility of enzymes or catalysts, are largely affected by porosity, pore structures, and pore size distribution. While X-ray computed tomography (CT) has been introduced to effectively produce 3D volumetric images of material microstructure, a quantitative porosity analysis from the 3D images has never been done. This work introduces a first-of-its-kind X-ray CT-based quantitative porosity analysis method and applies the developed toolkit to characterize the internal porosity distribution of loblolly pine. A sample loblolly pine chip was scanned by a nano-resolution X-ray CT system and digitally reconstructed after a sequence of image processing operations. Here, a comprehensive porosity analysis was then performed to quantify the envelope porosity, the spatial distribution of local porosity, and the directional porosity. Solutions to the various challenges in image processing, porosity calculation, and large data handling are provided.

42 ENGINEERING↗