Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Method for use of hydraulically or electrically controlled solenoids under failed on conditions

A method to operate a clutch device in an electro-mechanical transmission mechanically-operatively coupled to an internal combustion engine and at least one electric machine includes, in response to a failure condition detected within a flow control device configured to facilitate flow of hydraulic fluid for operating the clutch device, selectively preventing the flow of hydraulic fluid from entering the flow control device and feeding the clutch device. Synchronization of the clutch device is initiated when the clutch device is intended for activation, and only if the clutch device is synchronized, the flow of hydraulic fluid is selectively permitted to enter the flow control device to activate the clutch device.

42 ENGINEERING↗

Low-speed inducers for cryogenic upper-stage engines

Two-phase, low-speed hydrogen and oxygen inducers driven by electric motors and applicable to the tug engine were designed and constructed. The oxygen inducer was tested in liquid and two-phase oxygen. Its head and flow performance were approximately as designed, and it was able to accelerate to full speed in 3 seconds and produce its design flow and head. The analysis of the two-phase data indicated that the inducer was able to pump with vapor volume fractions in excess of 60 percent. The pump met all of its requirements (duration of runs and number of starts) to demonstrate its mechanical integrity.

Bissell, W. R.↗

Turbine Electrified Energy Management (TEEM) For Enabling More Efficient Engine Designs

NASA is investing in Electrified Aircraft Propulsion (EAP) research as part of an effort to assist industry in meeting the future needs of a global aviation market. The integration of electric machines into traditional turbine-based propulsion provides opportunities to change system architectures effecting radical improvements in propulsive efficiency. However, less consideration has been afforded to the utilization of these electrical machines to improve the thermal efficiency and performance of the gas turbine engine. Noting this deficit, a novel operability concept is proposed and is referred to as Turbine Electrified Energy Management (TEEM). The concept is a transient control technology that supplements the main fuel control for the suppression of the natural off-design dynamics associated with changes in engine operating state. Here the electric machines, used as engine actuators during the transient, add or extract torque from the engine shafts to maintain the speed-flow characteristics of steady-state design operation. This greatly reduces the need to maintain transient stall margin stack in the compressors, among other potential benefits. This paper demonstrates the feasibility of the concept in dynamic simulation using a Numerical Propulsion System Simulation (NPSS) engine model of a NASA hybrid electric propulsion concept known as the Parallel Hybrid Electric Turbofan (hFan).

Culley, Dennis E.↗

Evaluating an Eco-Cooperative Automated Control System

The paper evaluates an Eco-Cooperative Automated Control (Eco-CAC) system on a large-scale network considering a combination of internal combustion engine vehicles (ICEVs), hybrid electric vehicles (HEVs), and battery-only electric vehicles (BEVs) in a microscopic traffic simulation environment. We used a novel integrated control system that: (1) routes ICEVs, HEVs, and BEVs in a fuel/energy-efficient manner; (2) selects vehicle speeds based on anticipated traffic network evolution; (3) minimizes vehicle fuel/energy consumption near signalized intersections; and (4) intelligently modulates the longitudinal motion of vehicles along freeways within a cooperative platoon to minimize fuel/energy consumption. The study tested the system using the INTEGRATION software on the Los Angeles (LA), U.S., downtown network for three different demand levels: no congestion, mild congestion, and heavy congestion. The results demonstrated that the Eco-CAC system effectively reduces vehicle fuel and energy consumption, travel time, total delay, and stopped delay in heavily congested conditions. However, different vehicle compositions produced different results. In particular, the maximum energy consumption savings for BEVs (36.9%) for a current vehicle composition occurred at a 10% market penetration rate (MPR) of connected automated vehicles (CAVs) in mild congestion, while the maximum savings for a future vehicle composition (35.5%) occurred at a 50% CAV MPR in no congestion. The system reduced fuel consumption for ICEVs and HEVs by up to 5.4% and 6.3% at a 25% CAV MPR in heavy congestion for current and future vehicle compositions, respectively. However, the system increased total fuel consumption by up to 4.6% at a 50% CAV MPR in no congestion for a current vehicle composition. The study demonstrates that the effectiveness of the Eco-CAC system depends on traffic conditions, including congestion level, network configuration, CAV MPR, and vehicle composition.

Engineering↗

Medium-Duty Delivery Truck Integrated Bidirectional Wireless Power Transfer System With Grid and Stationary Energy Storage System Connectivity

Electric vehicles (EVs) can provide power to the grid or buildings similar to distributed energy resources (DER) for energy balancing applications or optimizing the operation of the microgrids in harmony with the other DER assets. This article presents the operating modes of a bidirectional wireless power transfer (WPT) system designed for a medium-duty package delivery vehicle. The WPT system designed for this study can transfer 20 kW of power across 11 in of air gap using custom-designed double-D (DD) couplers with LCC–LCC tuning networks. The proposed system utilizes a 480-V three-phase grid connection, a plug-in hybrid delivery truck with bidirectional WPT, and a stationary energy storage system (SESS) that can be connected to the primary-side dc link. Due to the differences in primary and secondary dc bus voltages, and considering the voltage of the SESS, asymmetric voltage gains were used in the system. Sensitivity analyses of this system with respect to these voltage levels are presented. Five different operating modes of the grid, SESS, and the EV battery are investigated with experimental results. Control algorithms are described for grid-to-vehicle (G2V) and vehicle-to-grid (V2G) operating modes. A bidirectional WPT system is operated with a power factor of 0.99 on the grid side in every operating mode. The EV battery was charged with 20.3 kW with an overall efficiency of 93.02% in the G2V operating mode. Finally, in the V2G operating mode, the WPT system provided 12.82 kW of power back to the grid with an overall efficiency of 89.08%.

25 ENERGY STORAGE↗

Tail-mounted engine Architecture and Design for the Subsonic Single Aft Engine Electrofan Aircraft

This paper describes the turbofan engine architecture for SUbsonic Single Aft eNgine (SUSAN) Electrofan is, a transformative concept hybrid electric aircraft. SUSAN has a single tail-mounted turbofan engine that produces a portion of the requires thrust and drives a 20MW electric generator which in turn provides the power to the 16 electric propulsors located on the wing responsible for producing the remainder of the required thrust. The atypical operation of the turbofan due to the large levels of power extraction from the low pressure turbine (LPT) is described here. This paper investigates the most efficient engine architecture to enable this unique operation, as well as exploring natural gas as an alternative fuel for SUSAN.

EAP↗

A method of increasing the sensitivity of protection from single-phase short-circuits to ground in the 6 - 10 kV network

A method of increasing the sensitivity of protection from single-phase short-circuits to ground by acting on the signal with brief dummy grounding of the neutral is described. After determining the damage, the neutral is again grounded through a high resistance and an arc-quenching reactor. An increase in the protection sensitivity is thereby obtained, the damage detection time is shortened, and the probability of the single-phase short-circuit to ground converting into double and multipoint earth faults is reduced.

42 ENGINEERING↗

The effectiveness of using the calculated braking current for longitudinal differential protection of 110 - 750 kV shunt reactors

The use of the function of effective current braking of the longitudinal differential protection of shunt reactors to offset current surges, which enables the sensitivity of differential protection to be increased when there are short circuits with low damage currents, is considered. It is shown that the use of the calculated braking characteristic enables the reliability of offset protection from transients to be increased when the reactor is connected, which is accompanied by the flow of asymmetric currents containing an aperiodic component.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Limitation of Transient Recovery Voltage When Using Shunt Reactors in 110 – 220 kV Networks

In design practice there often arises the problem of assessing the feasibility of installing shunt reactors (SR) when observing conditions of the occurrence of admissible transient recovery voltages at circuit breaker contacts during switching action. A simplified design methodology for this purpose is proposed for calculating the defining parameters of the SR connection circuit, making it possible to define the feasibility of its use in the analyzed circuit.

42 ENGINEERING↗

Analysis of the Trip of a High-Power Turbine-Generator of a Nuclear Power Plant Upon Damage of the Stator Winding Insulation According to Data of Monitoring and Modeling

The operating conditions of a turbine-generator with the stator winding short-circuited to the frame are analyzed. The features of the shape of the zero-sequence voltage during arcing in the damaged gap are described. The operation of the relay protection in these conditions is analyzed. The real oscillograms of the subsequent suppression of the rotor field are theoretically justified. It is shown that improving the thyristor excitation system is necessary and possible.

42 ENGINEERING↗

Analysis of Transient Recovery Voltage at the Terminals of Breakers Using Current-Limiting Reactors

Current-limiting reactors (CLR) are known to have a significant effect on transition processes during short circuits (SC) leading to excesses beyond the permissible values of the transient recovery voltage (TRV) at the terminals of breakers for short-circuit currents, which in turn can lead to failure of the breakers. It is shown that the traditional (generally accepted) method for calculating transient recovery voltages based on using a circuit with the reactor replaced by lumped parameters is not suitable for magnetized CLR, and in the case of uncontrolled CLR can yield erroneous results. It is argued that there is a need to account for the distribution of the winding parameters of current-limiting reactors in calculations of the TRV at the contacts of breakers as they interrupt short circuits and relevant analytic expressions are derived.

42 ENGINEERING↗

Conductive overbraid of continuous fiber thermoplastic composite tows

Here, to meet the increasing demand for lightweight materials with multifunctional capabilities, a new high-rate manufacturing method and material system, referred to as M-TOW ® (multifunctional-tow) is introduced. Overbraiding is used to incorporate highly conductive wire onto the continuous fiber reinforced tow (M-TOW ® ), offering a solution for integrating thermal and electrical conductivity into hybrid-molded composite structures. The conductivity performance of different wire configurations are compared before and after forming the M TOW ® , measuring electrical conductivities up to 5.5 x 10 5 S / cm and thermal conductivities up to 21 W / mK. Results conclude that the integration of conductive wires into thermoplastic preforms is a viable means of expanding the functionality of lightweight, high strength composite structures.

3-dimensional reinforcement↗

AgSb(S{sub x}Se{sub 1−x}){sub 2} thin films for solar cell applications

Highlights: ► AgSb(S{sub x}Se{sub 1−x}){sub 2} thin films were formed by heating Na{sub 2}SeSO{sub 3} dipped Sb{sub 2}S{sub 3}/Ag layers. ► S/Se ratio was varied by changing the dipping time in Na{sub 2}SeSO{sub 3} solution. ► Characterized the films using XRD, XPS, SEM, Optical and electrical measurements. ► Band gap engineering of 1−1.1 eV for x = 0.51 and 0.52 respectively. ► PV Glass/FTO/CdS/AgSb(S{sub x}Se{sub 1−x}){sub 2}/C were prepared showing V{sub oc} = 410 mV, J{sub sc} = 5.7 mA/cm{sup 2}. - Abstract: Silver antimony sulfoselenide (AgSb(S{sub x}Se{sub 1−x}){sub 2}) thin films were prepared by heating glass/Sb{sub 2}S{sub 3}/Ag layers after selenization using sodium selenosulphate solution. First, Sb{sub 2}S{sub 3} thin films were deposited on glass substrates from a chemical bath containing SbCl{sub 3} and Na{sub 2}S{sub 2}O{sub 3}. Then Ag thin films were thermally evaporated onto glass/Sb{sub 2}S{sub 3}, followed by selenization by dipping in an acidic solution of Na{sub 2}SeSO{sub 3}. The duration of selenium dipping was varied as 30 min and 2 h. The heating condition was at 350 °C for 1 h in vacuum. Analysis of X-ray diffraction pattern of the thin films formed after heating showed the formation of AgSb(S{sub x}Se{sub 1−x}){sub 2}. Morphology and elemental analysis were done by scanning electron microscopy and energy dispersive X-ray detection. Depth profile of composition of the thin films was performed by X-ray Photoelectron Spectroscopy. The spectral study showed the presence of Ag, Sb, S, and Se, and the corresponding binding energy analysis confirmed the formation of AgSb(S{sub x}Se{sub 1−x}){sub 2}. Photovoltaic structures (PV) were prepared using AgSb(S{sub x}Se{sub 1−x}){sub 2} thin films as absorber and CdS thin films as window layers on FTO coated glass substrates. The PV structures were heated at 60–80 °C in air for 1 h to improve ohmic contact. Analysis of J–V characteristics of the PV structures showed V{sub oc} from 230 to 490 mV and J{sub sc} 0.28 to 5.70 mA/cm{sup 2}, under illumination of AM1.5 radiation using a solar simulator.

36 MATERIALS SCIENCE↗

Field-Driven Simulations to Probe the Impact of Ionic Correlations on Solution Transport Coefficients in Binary, Ternary, and Reciprocal Quaternary Aqueous Electrolytes

Ionic correlations play a critical role in governing transport properties of mixed-salt aqueous electrolyte solutions, yet their quantitative characterization remains challenging, particularly for multicomponent aqueous systems. Here, we develop a general nonequilibrium molecular dynamics framework to efficiently compute Onsager transport coefficients and ionic correlations in mixed-salt aqueous solutions. Using field-driven simulations, we obtain accurate Onsager matrices for LiCl/ KCl, KCl/KBr, and LiBr/KCl electrolyte solutions with significantly reduced computational cost relative to equilibrium Green−Kubo methods. The framework enables direct assessment of how attractive cation−anion and repulsive like-ion interactions contribute to conductivity and salt diffusivity across compositions. While static ion pairing exhibits strong composition dependence, dynamic ion correlations remain nearly invariant, leading to constant deviations from Nernst−Einstein predictions. These results highlight the disconnect between static ion association and dynamic transport correlations, and they establish a transferable approach for analyzing ion transport in complex electrolyte environments relevant to separation processes and electrochemical systems.

36 MATERIALS SCIENCE↗

Elucidating Mass Transport Regimes in Gas Diffusion Electrodes for CO 2 Electroreduction

Gas diffusion electrodes (GDEs) have shown promising performance for the electrochemical reduction of CO 2 (CO 2 R). In this study, a resolved, pore scale model of electrochemical reduction of CO 2 within a liquid-filled catalyst layer is developed. Three CO 2 mass transport regimes are identified in which the CO 2 penetration depth is controlled by CO 2 consumption in the electrolyte, CO 2 conversion along the solid-electrolyte double-phase boundaries (DPBs), and CO 2 conversion concentrated around the gas–solid–electrolyte triple-phase boundaries (TPBs). While it is possible for CO 2 R to be localized around the TPBs, in systems with submicron pore radii operating at <1 A cm –2 CO 2 R will be distributed across the DPBs within the catalyst layer. This validates the assumption of pore-scale uniformity implicit in popular, volume-averaged GDE models. Overall, the CO 2 conversion efficiency depends strongly on the governing mass transport regime, and operational-phase diagrams are constructed to guide the catalyst layer design.

10 SYNTHETIC FUELS↗