Search NASA⌕ Search

SEARCH · Search NASA

Results for “error fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

The FIELDS Instrument Suite on MMS: Scientific Objectives, Measurements, and Data Products

The FIELDS instrumentation suite on the Magnetospheric Multiscale (MMS) mission provides comprehensive measurements of the full vector magnetic and electric fields in the reconnection regions investigated by MMS, including the dayside magnetopause and the night-side magnetotail acceleration regions out to 25 Re. Six sensors on each of the four MMS spacecraft provide overlapping measurements of these fields with sensitive cross-calibrations both before and after launch. The FIELDS magnetic sensors consist of redundant flux-gate magnetometers (AFG and DFG) over the frequency range from DC to 64 Hz, a search coil magnetometer (SCM) providing AC measurements over the full whistler mode spectrum expected to be seen on MMS, and an Electron Drift Instrument (EDI) that calibrates offsets for the magnetometers. The FIELDS three-axis electric field measurements are provided by two sets of biased double-probe sensors (SDP and ADP) operating in a highly symmetric spacecraft environment to reduce significantly electrostatic errors. These sensors are complemented with the EDI electric measurements that are free from all local spacecraft perturbations. Cross-calibrated vector electric field measurements are thus produced from DC to 100 kHz, well beyond the upper hybrid resonance whose frequency provides an accurate determination of the local electron density. Due to its very large geometric factor, EDI also provides very high time resolution (∼1 ms) ambient electron flux measurements at a few selected energies near 1 keV. This paper provides an overview of the FIELDS suite, its science objectives and measurement requirements, and its performance as verified in calibration and cross-calibration procedures that result in anticipated errors less than 0.1 nT in B and 0.5 mV/m in E. Summaries of data products that result from FIELDS are also described, as well as algorithms for cross-calibration. Details of the design and performance characteristics of AFG/DFG, SCM, ADP, SDP, and EDI are provided in five companion papers.

Electromagnetic field measurements↗

Physics-constrained deep learning of nonlinear normal modes of spatiotemporal fluid flow dynamics

In this study, we present a physics-constrained deep learning method to discover and visualize from data the invariant nonlinear normal modes (NNMs) which contain the spatiotemporal dynamics of the fluid flow potentially containing strong nonlinearity. Specifically, we develop a NNM-physics-constrained convolutional autoencoder (NNM-CNN-AE) integrated with a multi-temporal-step dynamics prediction block to learn the nonlinear modal transformation, the NNMs containing the spatiotemporal dynamics of the flow, and reduced-order reconstruction and long-time future-state prediction of the flow fields, simultaneously. In test cases, we apply the developed method to analyze different flow regimes past a cylinder, including laminar flows with low Reynolds number in transient and steady states (RD = 100) and high Reynolds number flow (RD = 1000), respectively. The results indicate that the identified NNMs are able to reveal the nonlinear spatiotemporal dynamics of these flows, and the NNMs-based reduced-order modeling consistently achieves better accuracy with orders of magnitudes smaller errors in construction and prediction of the nonlinear velocity and vorticity fields, compared to the linear proper orthogonal decomposition (POD) method and the Koopman-constrained-CNN-AE using the same number or dimension of modes. We perform an analysis of the modal energy distribution of NNMs and find that compared to POD modes, the few fundamental NNMs capture a very high level of total energy of the flow, which is advantageous for reduced-order modeling and representation of the complex flows. Finally, we discuss the potentials and limitations of the presented method.

Mechanics↗

Communication: Quantitative multi-site frequency maps for amide I vibrational spectroscopy

An accurate method for predicting the amide I vibrational spectrum of a given protein structure has been sought for many years. Significant progress has been made recently by sampling structures from molecular dynamics simulations and mapping local electrostatic variables onto the frequencies of individual amide bonds. Agreement with experiment, however, has remained largely qualitative. Previously, we used dipeptide fragments and isotope-labeled constructs of the protein G mimic NuG2b as experimental standards for developing and testing amide I frequency maps. Here, we combine these datasets to test different frequency-map models and develop a novel method to produce an optimized four-site potential (4P) map based on the CHARMM27 force field. Together with a charge correction for glycine residues, the optimized map accurately describes both experimental datasets, with average frequency errors of 2–3 cm{sup −1}. This 4P map is shown to be convertible to a three-site field map which provides equivalent performance, highlighting the viability of both field- and potential-based maps for amide I spectral modeling. The use of multiple sampling points for local electrostatics is found to be essential for accurate map performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing Impacts of Waves on Hub-Height Winds off the U.S. West Coast Using Lidar Buoys and Coupled Modeling Approaches

Given the importance of offshore wind energy development to the U.S. clean energy targets, it is vital to be able to characterize the wind resource in that environment accurately. Toward that end, two Bureau of Ocean Energy Management buoys equipped with Doppler lidar are being maintained by Pacific Northwest National Laboratory on behalf of the Department of Energy and deployed to regions of potential offshore wind development. In addition to standard meteorological and oceanographic measurements, the buoys document the wind profile between about 40 m and 250 m above the sea surface through Doppler lidar retrievals. After a multiyear deployment of two buoys along the U.S. East Coast, the buoys were redeployed to the U.S. West coast from 2020 – 2022 to locations near the Humboldt and Morro Bay lease areas. The buoys provide nearly continuous, multiyear datasets that can be used to evaluate predictions of hub-height (~100 m) wind speed for standard atmospheric models in the region. In the absence of measurements at the study site, offshore wind developers rely on model-based data to assess site conditions. Potential sources of model error in this environment include under-resolution or misrepresentation of coastal topographically forced flows, marine boundary layer dynamics and the evolution of their associated cloud and turbulence fields, the role of upwelling and other currents on surface heat fluxes into the boundary layer, and the impact of wave fields on surface momentum fluxes and thus the wind speed profile. In particular, most predictive models of wind speed do not predict wave fields at all, relying on parameterizations to represent their effects. In thus study, we focus on evaluating the role of wind / wave interactions on modeled hub-height wind speed and error by using the Coupled Ocean–Atmosphere–Wave–Sediment–Transport Modeling System to capture two-way interactions between an atmospheric model (Weather Research and Forecasting (WRF)) and a wave model (WAVEWATCHIII (WW3)) and compare to both stand-alone WRF and one-way coupled WRF / WW3 configurations. Our approach is similar to that used in Gaudet et al. (2022) to evaluate wind / wave coupling over the U.S. East Coast, but applied to the very different environment of the U.S. West Coast. We show examples for two cases, a cold-season frontal case and a warm-season low-level jet case. We find that wind / wave coupling makes little impact on model error for these cases at the location of the lidar buoys, for which other misrepresentations of model physics seems to be responsible for model-observation discrepancies. However, domain-wide evaluations, which also make use of the National Buoy Data Center network, show that a two-way coupling approach is less prone to systematic errors in the hub-height wind field than the one-way coupled approach. WRF resolution of kilometer-scale or less is needed to properly capture the sharp wind speed gradients that can be found along the coastline, and WW3 simulations driven by the downscaled WRF produce better bulk and spectral wave fields when compared to observations. Implications of the results for wind resource characterization are then discussed.

17 WIND ENERGY↗

Search for Pulsations from a Nearby Millisecond Pulsar and Wasilewski 49: Mirror for a Hidden Seyfert 1 Nucleus

Five studies are reported in this final report. The recently discovered 5.3 ms pulsar J1012+5307 at a distance of 520 pc is in an area of the sky which is particularly deficient in absorbing gas. The column density along the line of sight is less than 7.5 x 10(exp 19) CM(exp -2) which facilitates soft X-ray observations. Halpern reported a possible ROSAT Position Sensitive Proportional Counter (PSPC) detection of the pulsar in a serendipitous, off-axis observation. We have now confirmed the X-ray emission of PSR J1012+,5307 in a 23 ksec observation with the ROSAT High Resolution Imager (HRI). A point source is detected within 3" of the radio position. Its count rate of 1.6 +/- 0.3 x 10(exp -3) s(exp -1) corresponds to an unabsorbed 0. 1-2.4 keV flux of 6.4 x 10(exp -14) ergs cm(exp -2) s(exp -1), similar to that reported previously. This counts-to-flux conversion is valid for N(sub H) = 5 x 10(exp 19) cm(exp -2), and either a power-law spectrum of photon index 2.5 or a blackbody of kT = 0.1 keV. The implied X-ray luminosity of 2.0 x 10(exp 30) ergs s(exp -1) is 5 X 10(exp -4) of the pulsar's spin-down power dot-E, and similar to that of the nearest millisecond pulsar J0437-4715, which is nearly a twin of J1012+5307 in P dot-E. We subjected the 37 photons (and 13 background counts) within the source region to a pulsar search, but no evidence for pulsation was found. The pulsar apparently emits over a large fraction of its rotation cycle, and the absence of sharp modulation can be taken as evidence for surface thermal emission, as is favored for PSR J0437-4715, rather than magnetospheric X-ray emission which is apparent in the sharp pulses of the much more energetic millisecond pulsar B1821-24. A further test of this interpretation will be made with a longer ROSAT observation, which will increase the number of photons collected by a factor of 5, and permit a more sensitive examination of the light curve for modulation due to emission from heated polar caps. If found, such modulation will be further evidence that surface reheating by the impact of particles accelerated along open fiel;d lines operates in these approximately 10(exp -9) year old pulsars. In a second study, a new AM Her star serendipitously in a 25 day observation was detected with the EUVE satellite. A coherent period of 85.82 min is present in the EUVE Deep Survey imager light curve of this source. A spectroscopic optical identification is made with a 19th magnitude blue star that has H and He emission lines, and broad cyclotron humps typical of a magnetic cataclysmic variable. A lower limit to the polar magnetic field of 50 MG is estimated from the spacing of the cyclotron harmonics. EUVE J0425.6-5714 is also detected in archival ROSAT HRI observations spanning two months, and its stable and highly structured light curve permits us to fit a coherent ephemeris linking the ROSAT and EUVE data over a 1.3 yr gap. The derived period is 85.82107 +/- 0.00020 min, and the ephemeris should be accurate to 0.1 cycles until the year 2005. A narrow but partial X-ray eclipse suggests that this object belongs to the group of AM Her stars whose viewing geometry is such that the accretion stream periodically occults the soft X-ray emitting accretion spot on the surface of the white dwarf. A non-detection of hard X-rays from ASCA observations that are contemporaneous with the ROSAT HRI shows that the soft X-rays must dominate by at least an order of magnitude, which is consistent with a known trend among AM Her stars with large magnetic field. This object should not be confused with the Seyfert galaxy IH 0419-577 (= LB 1727), another X-ray/EUV source which lies only 3'95 away, and was the principal target of these monitoring observations. In a third report; the identity of the persistent high-energy (> 100 MeV) gamma-ray sources in the Galaxy, still largely a mystery is investigated. The second installment of the EGRET (2EG) lists a total of 128 sources, of which 51 are likely or possibly identified with AGNs, five with rotation-powered pulsars, and one is the LMC. There are 71 unidentified sources, of which 33, or almost half, lie in the narrow band of absolute value of b < 10 degrees along the Galactic plane. This excess of low-latitude sources must, therefore, constitute a Galactic population that is either similar to the already identified gamma-ray pulsars, or an entirely new class of gamma-ray emitters associated with the disk population. We are continuing our program, begun in A06, that is aimed at intermediate-latitude sources, arguing that X-ray detection of them is the most plausible method of identifying the Galactic population. The sources at high latitude must statistically be mostly AGNS, and are more straightforwardly identified through radio and optical means. For the fourth report, identification of the EGRET Source the identity of the persistent, high-energy gamma-ray sources in the Galactic plane is a mystery. The most likely scenario is a population of middle-aged pulsars, many of which could be radio quiet like Geminga. We have an ongoing program of ROSAT, VLA, and optical observations of selected EGRET error circles at intermediate Galactic latitude. For one of these fields, at (l, b) = (106 degrees, +3), our complete census of X-ray and radio sources, reveals a remarkable association between a radio shell with unique properties, and a complete census of X-ray and radio sources reveals a remarkable association between a radio shell with unique properties, and a compact X-ray source. Further observations are needed to determine whether or not this source has a hard X-ray spectrum like that of other gamma ray pulsars and, ideally, to find its pulsations. A fifth report reviews, Wasilewski 49, an interacting pair of Seyfert galaxies at z = 0.063, one of which contains a hidden Seyfert I nucleus as evidenced by broad wings on its Balmer lines.

Halpern, Jules P.↗

Simulations of Recovery of Time-Varying Gravity from DECIGO Pathfinder

We simulated time-varying Earth's gravity field recovered from DPF to evaluate an impact of DPF and future satellite gradiometry mission on earth science. From hydrological water movement data and orbit information, gravity gradients to be measured at altitude about ~500km were generated. Errors caused by atmospheric and oceanic variations and instrumental noise were added. Monthly gravity fields were estimated solving normal equations between spherical harmonic coefficients and simulated gravity gradient data. Simulation results show that DPF likely provides monthly hydrological water storage change with spatial scale between 400 and 1000km. Sensitivities to large scale estimates depends on long-term stability of gravity gradient measurement, and errors in short scale estimates are caused by instrumental noise and imperfections in atmospheric and ocean model. With acceleration noise level is lower than ~5 x 10(exp -14) [m/s2/sqrtHz] at frequency higher than 3mHz, water storage changes at limited small basins will be provided by DPF. To monitor continental scale hydrological water movement, noise level must be lower than ~5 x 10(exp -14) [m/s2/sqrtHz] at frequency higher than 1mHz.

Hasegawa, Takashi↗

Characterization of the onboard imaging unit for the first clinical magnetic resonance image guided radiation therapy system

Purpose: To characterize the performance of the onboard imaging unit for the first clinical magnetic resonance image guided radiation therapy (MR-IGRT) system. Methods: The imaging performance characterization included four components: ACR (the American College of Radiology) phantom test, spatial integrity, coil signal to noise ratio (SNR) and uniformity, and magnetic field homogeneity. The ACR phantom test was performed in accordance with the ACR phantom test guidance. The spatial integrity test was evaluated using a 40.8 × 40.8 × 40.8 cm{sup 3} spatial integrity phantom. MR and computed tomography (CT) images of the phantom were acquired and coregistered. Objects were identified around the surfaces of 20 and 35 cm diameters of spherical volume (DSVs) on both the MR and CT images. Geometric distortion was quantified using deviation in object location between the MR and CT images. The coil SNR test was performed according to the national electrical manufacturers association (NEMA) standards MS-1 and MS-9. The magnetic field homogeneity test was measured using field camera and spectral peak methods. Results: For the ACR tests, the slice position error was less than 0.10 cm, the slice thickness error was less than 0.05 cm, the resolved high-contrast spatial resolution was 0.09 cm, the resolved low-contrast spokes were more than 25, the image intensity uniformity was above 93%, and the percentage ghosting was less than 0.22%. All were within the ACR recommended specifications. The maximum geometric distortions within the 20 and 35 cm DSVs were 0.10 and 0.18 cm for high spatial resolution three-dimensional images and 0.08 and 0.20 cm for high temporal resolution two dimensional cine images based on the distance-to-phantom-center method. The average SNR was 12.0 for the body coil, 42.9 for the combined torso coil, and 44.0 for the combined head and neck coil. Magnetic field homogeneities at gantry angles of 0°, 30°, 60°, 90°, and 120° were 23.55, 20.43, 18.76, 19.11, and 22.22 ppm, respectively, using the field camera method over the 45 cm DSV. Conclusions: The onboard imaging unit of the first commercial MR-IGRT system meets ACR, NEMA, and vendor specifications.

60 APPLIED LIFE SCIENCES↗

Analysis and correction of errors in nanoscale particle tracking using the Single-pixel interior filling function (SPIFF) algorithm

Particle tracking, which is an essential tool in many fields of scientific research, uses algorithms that retrieve the centroid of tracked particles with sub-pixel accuracy. However, images in which the particles occupy a small number of pixels on the detector, are in close proximity to other particles or suffer from background noise, show a systematic error in which the particle sub-pixel positions are biased towards the center of the pixel. This “pixel locking” effect greatly reduces particle tracking accuracy. In this report, we demonstrate the severity of these errors by tracking experimental (and simulated) imaging data of optically trapped silver nanoparticles and single fluorescent proteins. We show that errors in interparticle separation, angle and mean square displacement are significantly reduced by applying the corrective Single-Pixel Interior Filling Function (SPIFF) algorithm. Our work demonstrates the potential ubiquity of such errors and the general applicability of SPIFF correction to many experimental fields.

Science & Technology - Other Topics↗

Accuracy of electromagnetic tracking with a prototype field generator in an interventional OR setting

Purpose: The authors have studied the accuracy and robustness of a prototype electromagnetic window field generator (WFG) in an interventional radiology suite with a robotic C-arm. The overall purpose is the development of guidance systems combining real-time imaging with tracking of flexible instruments for bronchoscopy, laparoscopic ultrasound, endoluminal surgery, endovascular therapy, and spinal surgery. Methods: The WFG has a torus shape, which facilitates x-ray imaging through its centre. The authors compared the performance of the WFG to that of a standard field generator (SFG) under the influence of the C-arm. Both accuracy and robustness measurements were performed with the C-arm in different positions and poses. Results: The system was deemed robust for both field generators, but the accuracy was notably influenced as the C-arm was moved into the electromagnetic field. The SFG provided a smaller root-mean-square position error but was more influenced by the C-arm than the WFG. The WFG also produced smaller maximum and variance of the error. Conclusions: Electromagnetic (EM) tracking with the new WFG during C-arm based fluoroscopy guidance seems to be a step forward, and with a correction scheme implemented it should be feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-404: Dosimetric Advantages of Flattening Free Beams to Prone Accelerated Partial Breast Irradiation

Purpose: Prone accelerated partial breast irradiation (APBI) results in dose reduction to the heart and lung. Flattening filter free beams (FFF) reduce out of field dose due to the reduced scatter from the removal of the flattening filter and reduce the buildup region. The aim of this work is to evaluate the dosimetric advantages of FFF beams to prone APBI target coverage and reduction in dose to organs at risk. Methods: Fifteen clinical prone APBI cases using flattened photon beams were retrospectively re-planned in Eclipse-TPS using FFF beams. FFF plans were designed to provide equivalent target coverage with similar hotspots using the same field arrangements, resulting in comparable target DVHs. Both plans were transferred to a prone breast phantom and delivered on Varian-Edge-Linac. GafChromic-film was placed in the coronal plane of the phantom, partially overlapping the treatment field and extending into OARs to compare dose profiles from both plans. Results: FFF plans were comparable to the clinical plans with maximum doses of (108.3±2.3)% and (109.2±2.4)% and mean doses of (104.5±1.0)% and (104.6±1.2)%, respectively. Similar mean dose doses to the heart and contralateral lungs were observed from both plans, whereas the mean dose to the contra-lateral breast was (2.79±1.18) cGy and (2.86±1.40) cGy for FFF and clinical plans respectively. However for both plans the error between calculated and measured doses at 4 cm from the field edge was 10%. Conclusion: The results showed that FFF beams in prone APBI provide dosimetrically equivalent target coverage and improved coverage in superficial target due to softer energy spectra. Film analysis showed that the TPS underestimates dose outside field edges for both cases. The FFF measured plans showed less dose outside the beam that might reduce the probability of secondary cancers in the contralateral breast.

60 APPLIED LIFE SCIENCES↗

On-Board Imaging Validation of Optically Guided Stereotactic Radiosurgery Positioning System for Conventionally Fractionated Radiotherapy for Paranasal Sinus and Skull Base Cancer

Purpose: To evaluate the positioning accuracy of an optical positioning system for stereotactic radiosurgery in a pilot experience of optically guided, conventionally fractionated, radiotherapy for paranasal sinus and skull base tumors. Methods and Materials: Before each daily radiotherapy session, the positioning of 28 patients was set up using an optical positioning system. After this initial setup, the patients underwent standard on-board imaging that included daily orthogonal kilovoltage images and weekly cone beam computed tomography scans. Daily translational shifts were made after comparing the on-board images with the treatment planning computed tomography scans. These daily translational shifts represented the daily positional error in the optical tracking system and were recorded during the treatment course. For 13 patients treated with smaller fields, a three-degree of freedom (3DOF) head positioner was used for more accurate setup. Results: The mean positional error for the optically guided system in patients with and without the 3DOF head positioner was 1.4 {+-} 1.1 mm and 3.9 {+-} 1.6 mm, respectively (p <.0001). The mean positional error drifted 0.11 mm/wk upward during the treatment course for patients using the 3DOF head positioner (p = .057). No positional drift was observed in the patients without the 3DOF head positioner. Conclusion: Our initial clinical experience with optically guided head-and-neck fractionated radiotherapy was promising and demonstrated clinical feasibility. The optically guided setup was especially useful when used in conjunction with the 3DOF head positioner and when it was recalibrated to the shifts using the weekly portal images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geometric and dosimetric accuracy of dynamic tumor-tracking conformal arc irradiation with a gimbaled x-ray head

Purpose: The Vero4DRT system has the capability for dynamic tumor-tracking (DTT) stereotactic irradiation using a unique gimbaled x-ray head. The purposes of this study were to develop DTT conformal arc irradiation and to estimate its geometric and dosimetric accuracy. Methods: The gimbaled x-ray head, supported on an O-ring gantry, was moved in the pan and tilt directions during O-ring gantry rotation. To evaluate the mechanical accuracy, the gimbaled x-ray head was moved during the gantry rotating according to input command signals without a target tracking, and a machine log analysis was performed. The difference between a command and a measured position was calculated as mechanical error. To evaluate beam-positioning accuracy, a moving phantom, which had a steel ball fixed at the center, was driven based on a sinusoidal wave (amplitude [A]: 20 mm, time period [T]: 4 s), a patient breathing motion with a regular pattern (A: 16 mm, average T: 4.5 s), and an irregular pattern (A: 7.2–23.0 mm, T: 2.3–10.0 s), and irradiated with DTT during gantry rotation. The beam-positioning error was evaluated as the difference between the centroid position of the irradiated field and the steel ball on images from an electronic portal imaging device. For dosimetric accuracy, dose distributions in static and moving targets were evaluated with DTT conformal arc irradiation. Results: The root mean squares (RMSs) of the mechanical error were up to 0.11 mm for pan motion and up to 0.14 mm for tilt motion. The RMSs of the beam-positioning error were within 0.23 mm for each pattern. The dose distribution in a moving phantom with tracking arc irradiation was in good agreement with that in static conditions. Conclusions: The gimbal positional accuracy was not degraded by gantry motion. As in the case of a fixed port, the Vero4DRT system showed adequate accuracy of DTT conformal arc irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An improved model for the Earth's gravity field

An improved model for the Earth's gravity field, TEG-1, was determined using data sets from fourteen satellites, spanning the inclination ranges from 15 to 115 deg, and global surface gravity anomaly data. The satellite measurements include laser ranging data, Doppler range-rate data, and satellite-to-ocean radar altimeter data measurements, which include the direct height measurement and the differenced measurements at ground track crossings (crossover measurements). Also determined was another gravity field model, TEG-1S, which included all the data sets in TEG-1 with the exception of direct altimeter data. The effort has included an intense scrutiny of the gravity field solution methodology. The estimated parameters included geopotential coefficients complete to degree and order 50 with selected higher order coefficients, ocean and solid Earth tide parameters, Doppler tracking station coordinates and the quasi-stationary sea surface topography. Extensive error analysis and calibration of the formal covariance matrix indicate that the gravity field model is a significant improvement over previous models and can be used for general applications in geodesy.

Tapley, B. D.↗

Spectral radiance errors in remote sensing ground studies due to nearby objects

Attention is given to the error that can occur in all radiometric measurements owing to the presence of nearby objects. When a researcher positions himself on the side of a target point opposite the sun, his body gives rise to two erroneous effects. First, it blocks a portion of the incoming diffuse sky radiance to the target point, and second, it reflects incoming diffuse and direct solar irradiance and ground exitance onto the target point. It is noted that the same phenomenon occurs for any nearby object, whether it be a field truck, a building structure, or a row of trees. This error deriving from nearby objects is often not recognized by researchers or is considered insignificant with no knowledge of its magnitude. The approach taken here is to mathematically model the radiant transfers that take place between the global irradiance, panel, or scene and the object and to report the magnitude of this error for various solar zenith angles, wavelengths, size and distances of objects (steradian blockage), and spectral reflectances of the scene and object. The scene, object, and panel are assumed to be Lambertian, and the object is always located on the side of the target point opposite the sun.

Kimes, D. S.↗

Ensemble Simulations of the 2012 July 12 Coronal Mass Ejection with the Constant-turn Flux Rope Model

Flux-rope-based magnetohydrodynamic modeling of coronal mass ejections (CMEs) is a promising tool for prediction of the CME arrival time and magnetic field at Earth. In this work, we introduce a constant-turn flux rope model and use it to simulate the 2012 July 12 16:48 CME in the inner heliosphere. We constrain the initial parameters of this CME using the graduated cylindrical shell (GCS) model and the reconnected flux in posteruption arcades. We correctly reproduce all the magnetic field components of the CME at Earth, with an arrival time error of approximately 1 hr. We further estimate the average subjective uncertainties in the GCS fittings by comparing the GCS parameters of 56 CMEs reported in multiple studies and catalogs. We determined that the GCS estimates of the CME latitude, longitude, tilt, and speed have average uncertainties of 5°.74, 11°.23, 24°.71, and 11.4%, respectively. Using these, we have created 77 ensemble members for the 2012 July 12 CME. We found that 55% of our ensemble members correctly reproduce the sign of the magnetic field components at Earth. We also determined that the uncertainties in GCS fitting can widen the CME arrival time prediction window to about 12 hr for the 2012 July 12 CME. On investigating the forecast accuracy introduced by the uncertainties in individual GCS parameters, we conclude that the half-angle and aspect ratio have little impact on the predicted magnetic field of the 2012 July 12 CME, whereas the uncertainties in longitude and tilt can introduce relatively large spread in the magnetic field predicted at Earth.

Talwinder Singh↗

Gravity field determination for Mars Observer

Mars Observer will be the first near circular, low altitude and short-periodic orbiter of Mars. From previous Mars orbiters, such as Mariner 9 and Vikings 1 and 2, a large gravitational oblateness and in general a gravity field ten times stronger than the earth's field have been determined. Because of these, the gravity field will dominate the evolution of the spacecraft's orbital motion and is the principal error source for reconstructing the spacecraft's motion. Thus a gravity calibration (GC) period has been established prior to the mapping phase in order to refine the gravitational field model. This paper describes the plan being made by Navigation to implement the GC strategy. By analyzing simulated Doppler data acquired during the seven day GC period, we give (1) the expected improvement in the gravity field model and (2) the resulting improvement in reconstructed spacecraft orbital motion. In addition, we have developed a strategy for converging the GC gravity model.

Esposito, Pasquale B.↗

Pressure Measurements Using an Airborne Differential Absorption Lidar: Analysis of the Systematic Error Sources - Part 1

Remote airborne measurements of the vertical and horizontal structure of the atmospheric pressure field in the lower troposphere are made with an oxygen differential absorption lidar (DIAL). A detailed analysis of this measurement technique is provided which includes corrections for imprecise knowledge of the detector background level, the oxygen absorption fine parameters, and variations in the laser output energy. In addition, we analyze other possible sources of systematic errors including spectral effects related to aerosol and molecular scattering interference by rotational Raman scattering and interference by isotopic oxygen fines.

Flamant, Cyrille N.↗

Model of Procedure Usage – Results from a Qualitative Study to Inform Design of Computer-Based Procedures

The nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. As a step toward the goal of improving procedure use performance, researchers, together with the nuclear industry, have been looking at replacing the current paper-based procedures with computer-based procedure systems. The concept of computer-based procedures is not new by any means; however most research has focused on procedures used in the main control room. Procedures reviewed in these efforts are mainly emergency operating procedures and normal operating procedures. Based on lessons learned for these previous efforts we are now exploring a more unknown application for computer based procedures - field procedures, i.e. procedures used by nuclear equipment operators and maintenance technicians. The Idaho National Laboratory, the Institute for Energy Technology, and participants from the U.S. commercial nuclear industry are collaborating in an applied research effort with the objective of developing requirements and specifications for a computer-based procedure system to be used by field operators. The goal is to identify the types of human errors that can be mitigated by using computer-based procedures and how to best design the computer-based procedures to do this. The underlying philosophy in the research effort is “Stop – Start – Continue”, i.e. what features from the use of paper-based procedures should we not incorporate (Stop), what should we keep (Continue), and what new features or work processes should be added (Start). One step in identifying the Stop – Start – Continue was to conduct a baseline study where affordances related to the current usage of paper-based procedures were identified. The purpose of the study was to develop a model of paper based procedure use which will help to identify desirable features for computer based procedure prototypes. Affordances such as note taking, markups, sharing procedures between fellow coworkers, the use of multiple procedures at once, etc. were considered. The model describes which affordances associated with paper based procedures should be transferred to computer-based procedures as well as what features should not be incorporated. The model also provides a means to identify what new features not present in paper based procedures need to be added to the computer-based procedures to further enhance performance. The next step is to use the requirements and specifications to develop concepts and prototypes of computer-based procedures. User tests and other data collection efforts will be conducted to ensure that the real issues with field procedures and their usage are being addressed and solved in the best manner possible. This paper describes the baseline study, the construction of the model of procedure use, and the requirements and specifications for computer-based procedures that were developed based on the model. It also addresses how the model and the insights gained from it were used to develop concepts and prototypes for computer based procedures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗