Search NASA⌕ Search

SEARCH · Search NASA

Results for “impression”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Ultrastable environment control for the NEID spectrometer: design and performance demonstration

Two key areas of emphasis in contemporary experimental exoplanet science are the detailed characterization of transiting terrestrial planets and the search for Earth analog planets to be targeted by future imaging missions. Both of these pursuits are dependent on an order-of-magnitude improvement in the measurement of stellar radial velocities (RV), setting a requirement on single-measurement instrumental uncertainty of order 10 cm∕s. Achieving such extraordinary precision on a high-resolution spectrometer requires thermomechanically stabilizing the instrument to unprecedented levels. We describe the environment control system (ECS) of the NEID spectrometer, which will be commissioned on the 3.5-m WIYN Telescope at Kitt Peak National Observatory in 2019, and has a performance specification of on-sky RV precision <50 cm/s. Because NEID’s optical table and mounts are made from aluminum, which has a high coefficient of thermal expansion, sub-milliKelvin temperature control is especially critical. NEID inherits its ECS from that of the Habitable-Zone Planet Finder (HPF), but with modifications for improved performance and operation near room temperature. Our full-system stability test shows the NEID system exceeds the already impressive performance of HPF, maintaining vacuum pressures below 10(exp −6) Torr and a root mean square (RMS) temperature stability better than 0.4 mK over 30 days. Our ECS design is fully open-source; the design of our temperature-controlled vacuum chamber has already been made public, and here we release the electrical schematics for our custom temperature monitoring and control system.

Paul Robertson↗

Impact of ATD-2 Tools on Human Factors Metrics at Charlotte Douglas International Airport

New decision support tools were introduced at Charlotte Douglas International Airport (CLT) as part of NASA’s Air Traffic Demonstration 2 (ATD-2) project. ATD-2 is based on concepts which enable integrated arrival, departures, and surface (IADS) operations in a metroplex environment. Metrics on environmental benefits from ATD-2’s surface metering at CLT have shown impressive reductions in fuel consumption and CO2 emissions. Questions have remained on 1) the human factors impact of these new ATD-2 tools and surface metering and 2) the users’ perceptions of how these tools affect operations. To address these questions, post-bank surveys were designed for the four types of users of the new tools at CLT: Ramp Controllers, Ramp Managers, Tower Traffic Management Coordinators (TMCs) and Terminal Radar Approach Control (TRACON) TMCs. These surveys were administered during five-day blocks at three different times. Three types of banks were compared: No ATD-2 tool use, ATD-2 tool use, and ATD-2 use plus surface metering. Results indicate that higher workload or decreased situation awareness was not significantly associated with ATD-2 tool use more than no ATD-2 tool use--in fact for many users the opposite was true. Also, acceptability and operational efficiency measures indicate that the users did not perceive that banks with ATD-2 tools were significantly less acceptable or less efficient than banks without ATD-2 tools.

Airspace Technology Demonstration 2↗

Impact of ATD-2 Tools on Human Factor Metrics at Charlotte Douglas International Airport

New decision support tools were introduced at Charlotte Douglas International Airport (CLT) as part of NASA’s Air Traffic Demonstration 2 (ATD-2) project. ATD-2 is based on concepts which enable integrated arrival, departures, and surface (IADS) operations in a metroplex environment. Metrics on environmental benefits from ATD-2’s surface metering at CLT have shown impressive reductions in fuel consumption and CO2 emissions. Questions have remained on 1) the human factors impact of these new ATD-2 tools and surface metering and 2) the users’ perceptions of how these tools affect operations. To address these questions, post-bank surveys were designed for the four types of users of the new tools at CLT: Ramp Controllers, Ramp Managers, Tower Traffic Management Coordinators (TMCs) and Terminal Radar Approach Control (TRACON) TMCs. These surveys were administered during five-day blocks at three different times. Three types of banks were compared: No ATD-2 tool use, ATD-2 tool use, and ATD-2 use plus surface metering. Results indicate that higher workload or decreased situation awareness was not significantly associated with ATD-2 tool use more than no ATD-2 tool use--in fact for many users the opposite was true. Also, acceptability and operational efficiency measures indicate that the users did not perceive that banks with ATD-2 tools were significantly less acceptable or less efficient than banks without ATD-2 tools.

Bonny K Parke↗

Market Survey 2020: Commercial Clinical Decision Support Systems and Wellness Tools

For long-duration, deep space exploration missions, current methods for managing and supporting crew health and medical conditions will be unsuitable. Communication and data transmission lags will necessitate the use of a sophisticated clinical decision support system (CDSS) that will tailor diagnosis and treatment guidance that is context-sensitive for anticipated astronaut health, wellness, and medical conditions. A variety of clinical decision support (CDS) and wellness tools (WT) are currently available in the commercial market and a broad-brush survey of this market can provide an initial impression of the current state of the art which, in turn, can inform the roadmap of NASA deep space CDSS development and associated requirements. Such a survey was undertaken during the first six months of 2020 using directed convenience sampling to obtain information provided by vendors on their websites; both commercially available CDS and WT (such as those used to track and monitor nutrition, exercise, and sleep) were included. Areas assessed were item type (e.g., software/application, device); primary purpose of the item (e.g., diagnostic support, nutrition tracking); additional purposes (if any); reported features, capabilities, and functionality; setting of use (e.g., inpatient, outpatient); intended user (e.g., clinician, patient); location and sources of data/information used or produced by the item; integration with patient electronic health record (EHR); compliance with interoperability ontologies and standards (e.g., Health Level 7 [HL7], Systematized Nomenclature of Medicine – Clinical Terminology [SNOMED-CT]); and whether the item is knowledge-based (derived from research findings) or non-knowledge-based (derived through artificial intelligence, machine learning, advanced probability and statistics), among others. Ninety-seven (97) vendor websites describing 196 CDS and 73 WT (269 total) were reviewed and coded. The primary purpose of the majority of CDS reviewed is diagnosis or diagnosis/treatment/drug decision support—targeted for clinician use— and the primary purpose of the majority of WT reviewed is the monitoring of different health metrics, most often through the use of a biosensor device (e.g., blood pressure)—targeted for patient use. Very few CDS or WT appear to comply with major international interoperability standards or can be integrated with a patient’s EHR data. None consider contextual factors, such as conditions of the physical environment (e.g., CO2 levels). The majority of CDS and WT reviewed are non-knowledge, cloud- or web-based applications or software. Forty-three (43) major findings were identified and the implications those findings have for NASA will be discussed. Example major findings include: CDS-WT capabilities range from diagnosis to treatment applications, CDS-WT may be wearable or non-wearable and are technologically advanced and only a few CDS-WT tools referenced compliance to ensure interoperability, among other findings. Recommendations will also be offered that will help to address ExMC Gap, Medical-701: Enhance medical capabilities within an exploration medical system.

market survey↗

Applying the System Complexity Metric (SCM)

A fundamental cause of difficulty in larger engineering projects is their inherent complexity. An impression of complexity occurs if a system is simply difficult to understand, so that there is no obvious mental model that correctly predicts its behavior. Higher complexity is usually associated with higher cost and higher failure rate. Complexity is indicated by a system having more and diverse components, multiple interactions and feedback loops, transients and dynamic behavior, and often the emergence of unanticipated failure modes. Identifying and removing these signs of complexity should reduce complexity and improve performance. Here we limit complexity measurement to the number of components and their interactions. A System Complexity Metric (SCM) is defined as equal to the sum of the number of parts in a system, N, plus the sum of the one-way interconnections between them, I. SCM = N + I. The SCM is easily determined by direct inspection of system block diagrams. Previous work found that life support system cost was directly proportional to SCM and that failure rate increased faster than SCM squared. SCM can be used to compare systems or to guide their redesign to reduce cost and failure rate. Carbon dioxide removal systems will be analyzed using SCM, cost, and failure rate.

Harry W Jones↗

LET and Range Characteristics of Proton Recoil Ions in Gallium Nitride (GaN)

A better understanding of the linear energy transfer and the range of proton recoil ions in gallium nitride is necessary to properly evaluate GaN device radiation tolerance. By analyzing the linear energy transfer (LET) and range of recoil heavy ions in GaN we can begin to reproduce the body of knowledge that exists for Si-based devices for this upcoming technology. Although the previous data on older technology has impressive depth and breadth we must be diligent and cautious in the application of these institutional intuitions when applied to emerging technologies such as GaN. As ever increasing materials science advances emerge, a sound methodology for evaluating new technologies must be established in order to apply what we know towards the effort of ensuring radiation tolerance.

gallium nitride (GaN)↗

Using the System Complexity Metric (SCM) to Compare CO2 Removal Systems

A fundamental cause of difficulty in large engineering projects is their inherent complexity. An impression of complexity occurs if a system is simply difficult to understand, where there is no obvious mental model that correctly predicts its behavior. Higher system complexity is usually associated with higher cost and higher failure rate. Complexity is perceived if a system has many diverse components, multiple interactions and feedback loops, transients and dynamic behavior, and unanticipated failure modes. Identifying and removing these signs of complexity should improve performance and reduce the cost and failure rate. Complexity can be directly measured by the number of components and their interactions. The System Complexity Metric (SCM) is defined as the sum of the number of parts in a system, N, plus the number of the one-way interconnections between them, I. SCM = N + I. The SCM is easily determined by direct inspection of the system block diagram. SCM can be used to compare systems and to guide their redesign to reduce cost and failure rate. Carbon dioxide removal systems are analyzed using SCM, cost, and failure rate. As in previous work, cost is directly proportional to SCM and that failure rate increases as a power of SCM for large differences in SCM. The SCM ranking of carbon dioxide removal systems is the same as their ranking in detailed analysis and practice.

Harry W. Jones↗

ELEET- Formulating a Multi-Element, Inter-agency Error Budget for Robust Earth Entry of Returned Mars Samples

The operational segment of a potential Mars Sample Return campaign could end with final delivery of the Earth Entry System to the surface of Earth, punctuating an impressive international collaboration on multiple flight elements over many years. A comprehensive error budget approach is presented to characterize the high-dimensional technical challenge of this concept, including inputs from interdisciplinary stakeholders. Effects considered include interplanetary navigation, spacecraft attitude and maneuver control, and entry environment, culminating in figures of merit such as landing range accuracy. Broad tradespace exploration confirms some intuitions while challenging others, and a set of solutions are identified that are mutually agreeable to NASA and ESA.

Lobbia, Marcus↗

Using the System Complexity Metric (SCM) to Compare CO2 Reduction Systems

A fundamental cause of difficulty in large engineering projects is their inherent complexity. An impression of complexity occurs if a system is simply difficult to understand, where there is no obvious mental model that correctly predicts its behavior. Higher system complexity is usually associated with higher cost and higher failure rate. Complexity is perceived if a system has many diverse components, multiple interactions and feedback loops, transients and dynamic behavior, and unanticipated failure modes. Identifying and removing these signs of complexity should improve performance and reduce the cost and failure rate. Complexity can be directly measured by the number of components and their interactions. The System Complexity Metric (SCM) is defined as the sum of the number of parts in a system, N, plus the number of the one-way interconnections between them, I. SCM = N + I. The SCM is easily determined by direct inspection of the system block diagram. SCM can be used to compare systems and to guide their redesign to reduce cost and failure rate. Carbon dioxide reduction systems are analyzed using SCM, cost, and failure rate. As in previous work, cost is directly proportional to SCM and that failure rate increases as a power of SCM for large differences in SCM. The SCM ranking of carbon dioxide reduction systems is the same as their ranking in detailed analysis and practice.

Harry W. Jones↗

The System Complexity Metric (SCM) Explains Systems Design and is Correlated with Cost and Failure Rate

The human short term memory span and working capacity is limited to three to five items, especially if they are organized complex “chunks” of information. The impression of complexity occurs when a system is simply difficult to understand, where there is no apparent pattern to predict its behavior. Hierarchical systems design can reduce perceived complexity and increase the amount of information that can be managed. The SCM was developed to measure complexity and help compare proposed overall system architectures before detailed design information is available. The SCM is defined as the sum of the number of major nodes, N, in the system block diagram plus the number of one-way interactions, I, between the nodes. SCM = N + I. SCM’s are easily determined by direct inspection of high-level block diagrams of life support systems. Axiomatic design develops a hierarchy of subsystem requirements and designs together in a top-down, back-and-forth process. A coupling matrix is used to control the relationships between the subsystem functions and design concepts. Axiomatic design can improve system design by decoupling requirements and designs. Axiomatic design was applied to the planning of a closed life support system, similar to that used on the International Space Station. A materially open as opposed to a closed system design was created by removing the interconnections required to close the system. The open system had the same number of designed subsystems as the closed system, but it had many fewer interconnections and its SCM was lower by about half. The costs were estimated and the MTBF (Mean Time Before Failure) tabulated for open and closed space life support systems. The estimated costs were linearly proportional to SCM for the wide variations of SCM in life support, but small differences may not be significant. The flight and preflight MTBF’s both declined exponentially with increasing MTBF, faster than MTBF-2, even though the preflight estimated MTBF’s were about ten times higher than the flight MTBF’s.

System Complexity Metric (SCM)↗

Toward Design Assurance of Machine-Learning Airborne Systems

In recent years, Artificial Intelligence (AI) systems, enabled by Machine Learning (ML)technology, have demonstrated impressive progress and provides historic opportunities for the aviation industry. However, several key aspects of ML technology are not compatible with existing design assurance standards and make certification problematic. In this paper, we present a case study of a visual system with a Deep Neural Network (DNN) intended to detect and identify airport runway signs. Different use cases and variants of this system exhibit different levels of criticality ranging from design assurance level (DAL) D to B. We use the case study to illustrate the challenges of certification according to the current standards, such asDO-178C. We present the system design, data generation, training, and verification in detail and describe how the design assurance objectives can be met for a DAL D variant of the system. We also discuss gaps and potential approaches for the higher design assurance levels.

Avionics↗

INTEGRAL reloaded: Spacecraft, instruments and ground system

The European Space Agency’s INTErnational Gamma-Ray Astrophysics Laboratory (ESA/INTEGRAL) was launched aboard a Proton-DM2 rocket on 17 October 2002 at 06:41 CEST, from Baikonur in Kazakhstan. Since then, INTEGRAL has been providing long, uninterrupted observations (up to about 47 h, or 170 ksec, per satellite orbit of 2.7 days) with a large field-of-view (FOV, fully coded: 100 deg), millisecond time resolution, keV energy resolution, polarization measurements, as well as additional wavelength coverage at optical wavelengths. This is realized by two main instruments in the 15 keV to 10 MeV energy range, the spectrometer SPI (spectral resolution 3 keV at 1.8 MeV) and the imager IBIS (angular resolution: 12 arcmin FWHM), complemented by X-ray (JEM-X; 3–35 keV) and optical (OMC; Johnson V-band) monitor instruments. All instruments are co-aligned to simultaneously observe the target region. A particle radiation monitor (IREM) measures charged particle fluxes near the spacecraft. The Anti-coincidence subsystems of the main instruments, built to reduce the background, are also very efficient all-sky γ-ray detectors, which provide virtually omni-directional monitoring above ~75 keV. Besides the long, scheduled observations, INTEGRAL can rapidly (within a couple of hours) re-point and conduct Target of Opportunity (ToO) observations on a large variety of sources. INTEGRAL observations and their scientific results have been building an impressive legacy: The discovery of currently more than 600 new high-energy sources; the first-ever direct detection of (56)Ni and (56)Co radio-active decay lines from a Type Ia supernova; spectroscopy of isotopes from galactic nucleo-synthesis sources; new insights on enigmatic positron annihilation in the Galactic bulge and disk; and pioneering gamma-ray polarization studies. INTEGRAL is also a successful actor in the new multi-messenger astronomy introduced by non-electromagnetic signals from gravitational waves and from neutrinos: INTEGRAL found the first prompt electromagnetic radiation in coincidence with a binary neutron star merger. Up to now more than 1750 scientific papers based on INTEGRAL data have been published in refereed journals. In this paper, we will give a comprehensive update of the satellite status after more than 18 years of operations in a harsh space environment, and an account of the successful Ground Segment.

Erik Kuulkers↗

Swarm Mentality: Toward Automatic Swarm State Awareness with Runtime Verification

Cyber-Physical Systems (CPSs) already exhibit impressive performance in all areas of human life, and swarms of CPSs promise to increase their capabilities even further. However, to effectively utilize CPS swarms their complexity of operation has to scale sub-linearly with the number of swarm members. Presenting the swarm to an operator as a single entity almost eliminates the additional per-member overhead entirely. To operate a swarm as one entity, and/or to increase the swarm’s autonomy, the operator and the swarm members need to reason and communicate at the same level of abstraction, i.e. the swarm needs a sense of “self.” Therefore, we require the ability to specify whole swarm properties yet monitor them at the member level. We examine one architecture for achieving this awareness by: 1) Defining a taxonomy for comparing techniques that synthesize this belief-state 2) Propose use of the Runtime Verification formal method to fill this role 3) Present preliminary designs for extending and embedding such a system in the Distributed Spacecraft Autonomy architecture to generate per-member monitors from swarm level specification.

Runtime Verification↗

Megafires in a Warming World: What Wildfire Risk Factors Led to California’s Largest Recorded Wildfire

Massive wildfires and extreme fire behavior are becoming more frequent across the westernUnited States, creating a need to better understand how megafire behavior will evolve in our warmingworld. Here, the fire spread model Prometheus is used to simulate the initial explosive growth ofthe 2020 August Complex, which occurred in northern California (CA) mixed conifer forests. Hightemperatures, low relative humidity, and daytime southerly winds were all highly correlated withextreme rates of modeled spread. Fine fuels reached very dry levels, which accelerated simulationgrowth and heightened fire heat release (HR). Model sensitivity tests indicate that fire growth andHR are most sensitive to aridity and fuel moisture content. Despite the impressive early observedgrowth of the fire, shifting the simulation ignition to a very dry September 2020 heatwave predicted a>50% increase in growth and HR, as well as increased nighttime fire activity. Detailed model analysesof how extreme fire behavior develops can help fire personnel prepare for problematic ignitions.

Kevin Varga↗

GRX-810: NASA High Temperature Alloy Development for Additive Manufacturing

High-entropy alloys, and by extension, medium entropy alloys are an exciting new class of materials due to their impressive mechanical properties, especially at cryogenic and elevated temperatures. In this study, a novel oxide dispersion strengthened (ODS) NiCoCr-based alloy is presented which exhibits exceptional high temperature properties compared to conventional wrought superalloys. This new ODS alloy, GRX-810, leverages additive manufacturing to disperse nanoscale Y2O3 particles throughout the microstructure without the use of resource intensive processing steps, such as mechanical alloying. Microstructural and mechanical characterization confirms the successful incorporation and dispersion of nano-scale oxides throughout the build volume. As a result, this recently discovered processing route presents a new alloy design and production path that is synergistic between additive manufacturing and dispersion strengthening, possibly enabling a new generation of high-performance alloys.

Tim Smith↗

Henrich Focke —Inventor of the First Successful Helicopter

In 1924, Henrich Focke, Georg Wulf and Dr. Werner Naumann started Focke-Wulf Flugzeugbau GmbH (Focke-Wulf Aircraft Manufacturing Ltd.). Focke-Wulf constructed Juan de la Cierva’s C.19 and C.30 Autogiros under license from 1930 until 1937. This led Focke to design the first successful and fully controllable helicopter, the Fw-61. Model tests in his wind tunnel supported the configuration and in 1932 Focke proposed a helicopter project to the ministry with drawings and calculations, which was granted in that same year. Impressed with the success of the Fw-61, the German Air Ministry suggested that Focke establish a new company dedicated to helicopter development and issued him a requirement for an improved design, capable of carrying a 700 kg (1,500 lbs) payload. Focke and Gerd Achgelis (a test pilot) partnered to establish the Focke–Achgelis company in 1938. The Fw-61 became the Fa-61. Historically, Henrich Focke and his Focke-Achgelis company must surely be considered as the developer of the world’s first successful helicopter. They began development of the Focke Wulf company’s Model Fw-61 helicopter, which had a side-by-side rotor system, in 1932. First flight was achieved on June 26, 1936 with test pilot Ewald Rohlfs at the controls. With the Fw-61’s flight demonstrated success, Professor Focke went on to present three early papers: 1. Das Trag- und Hubschrauberproblem (Autogyro and Helicopter Problems), November 1937 2. Forschung und Entwicklung der Drehflügelflugzeuge (Research and Development of Rotating Wing Aircraft), April 1942 3. Fortschritte des Hubschraubers (Progress of the Helicopter), October 1943 The first paper was also published by the German Museum (Munich) in 1938 and it was translated into English on the order of the Ministry of Aircraft Production by J. Helledoren as R.T.P No. 2128 at the end of 1937. The other two reports, however, appear not to have been translated during or after World War II and thus are made public here – probably for the first time. Translations of the three Focke papers are provided in this report. A careful translation from German to English of the papers has been made. Many of original photos have been recovered from the German Museum (Munich). In several cases, the original graphs have been redrawn to enhance each paper’s technical value. The editors have added footnotes where appropriate. The editors consider Focke’s papers to be of such immense technical and historical value that they deserve wide distribution to the rotorcraft industry. Finally, the editors believe that readers of the many technical points Henrich Focke makes about his development program will see that Focke’s program anticipated even today’s best rotorcraft industry efforts.

Inventor↗

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗