Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Nucleosynthesis at Strong Magnetization and the Titanium Problem

Ultramagnetized atomic nuclei created in supernova explosions, neutron star mergers, magnetar crusts and heavy ion collisions are considered. It is shown that for field strengths of 0.1–10 teratesla, the linear magnetic response dominates and the Zeeman effect leads to an increase in the binding energy of atomic nuclei with open shells. Considerable increase in a yield of corresponding products of explosive nucleosynthesis is consistent with results of observations. For iron-group nuclei, such a magnetic enhancement of {sup 44}Ti yield also implies a significant increase in the fraction of the main titanium isotope {sup 48}Ti in the chemical composition of galaxies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TLD efficiency calculations for heavy ions: an analytical approach

The use of thermoluminescent dosimeters (TLDs) in heavy charged particles’ dosimetry is limited by their non-linear dose response curve and by their response dependence on the radiation quality. Thus, in order to use TLDs with particle beams, a model that can reproduce the behavior of these detectors under different conditions is needed. Here a new, simple and completely analytical algorithm for the calculation of the relative TL-efficiency depending on the ion charge Z and energy E is presented. In addition, the detector response is evaluated starting from the single ion case, where the computed effectiveness values have been compared with experimental data as well as with predictions from a different method. The main advantage of this approach is that, being fully analytical, it is computationally fast and can be efficiently integrated into treatment planning verification tools. In conclusion, the calculated efficiency values have been then implemented in the treatment planning code TRiP98 and dose calculations on a macroscopic target irradiated with an extended carbon ion field have been performed and verified against experimental data.

43 PARTICLE ACCELERATORS↗

Characterization of the pyroelectric coefficient of a high-temperature sensor

Temperature is one of the most important thermodynamic properties measured and controlled in energy generation systems. To operate the energy system at optimum operating conditions for lower emission and higher efficiency, it is important to measure real-time temperatures. Furthermore, temperature sensing in intense environments is necessary since most sensors in energy systems get exposed to elevated temperatures, corrosive environments, and elevated pressures. One of the solutions for developing harsh environment sensors is to use ceramic materials, especially functional ceramics such as pyroelectrics. Pyroelectric ceramics could be used to develop active sensors for both temperature and pressure due to their capabilities in coupling energy among mechanical, thermal, and electrical domains. In this study, Lithium niobate (LiNbO 3 ) pyroelectric ceramic material was used to develop a temperature sensor for high-temperature applications. LiNbO 3 has high Curie temperature (1210°C) compared to other pyroelectric ceramic materials. A high Curie temperature material is important since the polarization properties of the material break down above the Curie temperature. Hence, the use of a material with a higher Curie temperature, such as LiNbO 3 , makes it promising to be used as a sensing material for high-temperature applications. A study was performed to actively measure the temperature up to 500°C using a pyroelectric ceramic lithium niobate (LiNbO 3 ) as a sensor material. Due to the non-linear pyroelectric response of LiNbO 3 , the temperature-dependent pyroelectric coefficient of LiNbO 3 was measured with a dynamic pyroelectric coefficient technique in temperature ranges up to 500°C. Temperature-dependent pyroelectric coefficient of LiNbO 3 was found to increase from −0.5 × 10 −5 to −3.70 × 10 −5 C/m 2 °C from room temperature to 500°C. The LiNbO 3 sensor was then tested for higher temperature sensing at 220°C, 280°C, 410°C, and 500°C and has shown 4.31%, 2.1%, 0.4%, and 0.6% deviation, respectively, compared with thermocouple measurements.

Sarker, Md Rashedul H.↗

Simple strategy for the simulation of axially symmetric large-area metasurfaces

Metalenses are composed of nanostructures for focusing light and have been widely explored in many exciting applications. However, their expanding dimensions pose simulation challenges. We propose a method to simulate metalenses in a timely manner using vectorial wave and ray tracing models. We sample the metalens’s radial phase gradient and locally approximate the phase profile by a linear phase response. Each sampling point is modeled as a binary blazed grating, employing the chosen nanostructure, to build a transfer function set. The metalens transmission or reflection is then obtained by applying the corresponding transfer function to the incoming field on the regions surrounding each sampling point. Fourier optics is used to calculate the scattered fields under arbitrary illumination for the vectorial wave method, and a Monte Carlo algorithm is used in the ray tracing formalism. We validated our method against finite-difference time domain simulations at 632 nm, and we were able to simulate metalenses larger than 3000 wavelengths in diameter on a personal computer.

Martins, Augusto (ORCID:0000000295546481)↗

Radiation Effects on Mortality from Solid Cancers Other than Lung, Liver, and Bone Cancer in the Mayak Worker Cohort: 1948–2008

Radiation effects on mortality from solid cancers other than lung, liver, and bone cancer in the Mayak worker cohort: 1948–2008. The cohort of Mayak Production Association (PA) workers in Russia offers a unique opportunity to study the effects of prolonged low dose rate external gamma exposures and exposure to plutonium in a working age population. We examined radiation effects on the risk of mortality from solid cancers excluding sites of primary plutonium deposition (lung, liver, and bone surface) among 25,757 workers who were first employed in 1948–1982. During the period 1948–2008, there were 1,825 deaths from cancers other than lung, liver and bone. Using colon dose as a representative external dose, a linear dose response model described the data well. The excess relative risk per Gray for external gamma exposure was 0.16 (95% CI: 0.07 – 0.26) when unadjusted for plutonium exposure and 0.12 (95% CI 0.03 – 0.21) when adjusted for plutonium dose and monitoring status. There was no significant effect modification by sex or attained age. Plutonium exposure was not significantly associated with the group of cancers analyzed after adjusting for monitoring status. Site-specific risks were uncertainly estimated but positive for 13 of the 15 sites evaluated with a statistically significant estimate only for esophageal cancer. Comparison with estimates based on the acute exposures in atomic bomb survivors suggests that the excess relative risk per Gray for prolonged external exposure in Mayak workers may be lower than that for acute exposure but, given the uncertainties, the possibility of equal effects cannot be dismissed.

60 APPLIED LIFE SCIENCES↗

Development of a MEMS dual-axis differential capacitance floating element shear stress sensor

A single-axis MEMS wall shear stress sensor with differential capacitive transduction method is produced. Using a synchronous modulation and demodulation interface circuit, the system is capable of making real time measurements of both mean and fluctuating wall shear stress. A sensitivity of 3.44 mV/Pa is achieved, with linearity in response demonstrated up to testing limit of 2 Pa. Minimum detectable signals of 340 μPa at 100 Hz and 120 μPa at 1 kHz are indicated, with a resonance of 3.5 kHz. Multiple full scale wind tunnel tests are performed, producing spectral measurements of turbulent boundary layers in wind speeds ranging up to 0.5 Ma (18 Pa of mean wall shear stress). The compact packaging allows for minimally invasive installation, and has proven relatively robust over multiple testing events. Temperature sensitivity, likely due to poor CTE matching of packaged materials, is an ongoing concern being addressed. These successes are being directly leveraged into a development plan for a dual-axis wall shear stress sensor, capable of producing true vector estimates at the wall.

47 OTHER INSTRUMENTATION↗

Experimental Evaluation of the Fast-Neutron Passive Collar (FNPC) Performance and Comparison with Scintillation Based Collars

This report describes a new method for the verification of fresh low enrichment uranium (LEU) fuel assemblies that can reduce International Atomic Energy Agency (IAEA) inspection time in the field and be completely independent of operator declared burnable poison content. The passive measurement makes unattended mode operation practical, and thus provides the potential for reducing inspector time in the field for future applications. The new simplified passive neutron measurement uses the 238 U spontaneous fission in LEU fresh fuel rods to self-interrogate the 235 U mass in the neighboring rods. The measured response increases linearly with the increase in the linear density (LD) of 235 U. The relatively high efficiency of the passive neutron detector (24%) provides good statistical precision (~ 2%) for the singles, doubles, and triples counting rates in the thermal-neutron mode. The three observables makes possible multiplicity analysis so that both the 235 U LD and the effective burnable poison content can be determined independent of the operator declarations. This closes the potential diversion path of miss-declaration the burnable poison content. This report presents the detector design, the as-built system, the detector parameter measurements, the calibration, and the assay uncertainty estimates. The calibration measurements were performed using the Los Alamos Laboratory mockup PWR fuel assembly. The measurements were made in both the fastneutron mode (with Cd/Gd metal liners) and the thermal-neutron mode (no Cd/Gd liners).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Low Cost Infrasound Sensor Packages

Sandia National Laboratories has tested and evaluated the performance of the following five models of low-cost infrasound sensors and sensor packages: Camas microphone, Gem Infrasound Logger, InfraBSU sensor, Raspberry Boom, and the Samsung S10 smartphone utilizing the Redvox app. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, self-noise, dynamic range, response, passband, linearity, sensitivity variation due to changes in static pressure and temperature, and sensitivity to vertical acceleration. The infrasound monitoring community has leveraged such sensors and integrated packages in novel ways; better understanding the performance of these units serves the geophysical monitoring community.

42 ENGINEERING↗

Genomic stability in response to high versus low linear energy transfer radiation in Arabidopsis thaliana

Low linear energy transfer (LET) gamma rays and high LET HZE (high atomic weight, high energy) particles act as powerful mutagens in both plants and animals. DNA damage generated by HZE particles is more densely clustered than that generated by gamma rays. To understand the genetic requirements for resistance to high versus low LET radiation, a series of Arabidopsis thaliana mutants were exposed to either 1GeV Fe nuclei or gamma radiation. A comparison of effects on the germination and subsequent growth of seedlings led us to conclude that the relative biological effectiveness (RBE) of the two types of radiation (HZE versus gamma) are roughly 3:1. Similarly, in wild-type lines, loss of somatic heterozygosity was induced at an RBE of about a 2:1 (HZE versus gamma). Checkpoint and repair defects, as expected, enhanced sensitivity to both agents. The “replication fork” checkpoint, governed by ATR, played a slightly more important role in resistance to HZE-induced mutagenesis than in resistance to gamma induced mutagenesis.

59 BASIC BIOLOGICAL SCIENCES↗

Rapid detection of Ebola virus with a reagent-free, point-of-care biosensor

Surface acoustic wave (SAW) sensors can rapidly detect Ebola antigens at the point-of-care without the need for added reagents, sample processing, or specialized personnel. This preliminary study demonstrates SAW biosensor detection of the Ebola virus in a concentration-dependent manner. The detection limit with this methodology is below the average level of viremia detected on the first day of symptoms by PCR. We observe a log-linear sensor response for highly fragmented Ebola viral particles, with a detection limit corresponding to 1.9 × 10⁴ PFU/mL prior to virus inactivation. We predict greatly improved sensitivity for intact, infectious Ebola virus. This point-of-care methodology has the potential to detect Ebola viremia prior to symptom onset, greatly enabling infection control and rapid treatment. This biosensor platform is powered by disposable AA batteries and can be rapidly adapted to detect other emerging diseases in austere conditions.

60 APPLIED LIFE SCIENCES↗

A Passive Magnetoelastic Radiation Sensor

A passive gamma detection technology, consisting of a fielded sensor and a separate analysis system, is described. The sensor is a small cylinder, about 2.5 mm in diameter and 15 mm in length. It requires no onboard power sources or physical connections for power or data transfer, and retains its cumulative response to radiation. The sensor consists of an amorphous magnetoelastic wire held in a longitudinally-stressed state by a radiation-sensitive material. When the radiation-sensitive material is subjected to gamma radiation, it mechanically degrades, relaxing the stress on the wire and lowering the wire’s magnetic permeability. The changes in permeability are observed by switching the magnetic domains in the wire and measuring the reduction in the Faraday voltage as the stress is diminished. The analysis package is built around an excitation-detection coil set and can communicate wirelessly with the sensor through a metallic or nonmetallic barrier at distances up to about 25 mm. The sensor response is linear up to a dose of at least 7 kGy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Stochastic Gause Predator-Prey model: Noise-induced extinctions and invariance

We consider the Gause predator-prey with general bounded or sub‑linear functional responses, – which includes those of Holling types Ⅰ–Ⅳ. – and multiplicative Gaussian noise. In contrast to previous studies, the prey in our model follows logistic dynamics while the predator's population is solely regulated by consumption of the prey. To ensure well-posedeness, we derive explicit Lyapunov‐type criteria ensuring global positivity and moment boundedness of solutions. We find conditions for noise‑induced extinctions, proving that stochasticity can drive either population to collapse even when the deterministic analogue predicts stable coexistence. In the case when the predator becomes extinct, we establish a limiting distribution for the predator's population. Last, for functional responses of Holling type Ⅰ, we provide sufficient conditions on the intensity of the noise for the existence and uniqueness of a stationary distribution.

Gause model↗

Mechanical property of solithane 113

Models to study failure under stress of Solithane 113 and set of equations for stress, strain, and energy responses of linear viscoelastic systems for wide spectrum of load inputs

ENERGY EQUATION↗

Blackbody cavity radiometer has rapid response

Fast response, spectrally linear standard detector in the form of a blackbody cavity radiometer calibrates rapidly responding photodetectors against a calibrated standard detector. A power amplifier with maximum available gain reduces error signal without stability loss. It may be used as a blackbody radiator by manipulation of the bridge variable arm.

Haley, F. C.↗

Accurate digital technique simulates flight control system

Fast, accurate technique for simulating the Saturn Flight Control System was devised. The technique is simple to implement and can be readily substituted for slower or less accurate techniques. This technique can be applied to a large class of problems that require a rapid accurate calculation of the response of linear differential equations to a continuous input.

Hays, J. R.↗