Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Net Metering and Market Feedback Loops: Exploring the Impact of Retail Rate Design on Distributed PV Deployment

The substantial increase in deployment of customer-sited solar photovoltaics (PV) in the United States has been driven by a combination of steeply declining costs, financing innovations, and supportive policies. Among those supportive policies is net metering, which in most states effectively allows customers to receive compensation for distributed PV generation at the full retail electricity price. The current design of retail electricity rates and the presence of net metering have elicited concerns that the possible under-recovery of fixed utility costs from PV system owners may lead to a feedback loop of increasing retail prices that accelerate PV adoption and further rate increases. However, a separate and opposing feedback loop could offset this effect: increased PV deployment may lead to a shift in the timing of peak-period electricity prices that could reduce the bill savings received under net metering where time-varying retail electricity rates are used, thereby dampening further PV adoption. In this paper, we examine the impacts of these two competing feedback dynamics on U.S. distributed PV deployment through 2050 for both residential and commercial customers, across states. Our results indicate that, at the aggregate national level, the two feedback effects nearly offset one another and therefore produce a modest net effect, although their magnitude and direction vary by customer segment and by state. We also model aggregate PV deployment trends under various rate designs and net-metering rules, accounting for feedback dynamics. Our results demonstrate that future adoption of distributed PV is highly sensitive to retail rate structures. Whereas flat, time-invariant rates with net metering lead to higher aggregate national deployment levels than the current mix of rate structures (+5% in 2050), rate structures with higher monthly fixed customer charges or PV compensation at levels lower than the full retail rate can dramatically erode aggregate customer adoption of PV (from -14% to -61%, depending on the design). Moving towards time-varying rates, on the other hand, may accelerate near- and medium-term deployment (through 2030), but is found to slow adoption in the longer term (-22% in 2050).

14 SOLAR ENERGY↗

Flow and Heat Transfer Tests in New Loop at 2757 kPa (400 psi)

A helium flow and heat transfer experiment has been designed for the new helium flow loop facility at LANL. This new facility is centered on an Aerzen GM 12.4 Root’s blower, selected for operation at higher pressure, up to 2757 kPa, and mass flow rate, up to 400 g/s. This replaces the previous Tuthill PD plus 3206 blower and loop limited to 2067 kPa (300 psi) and 100 g/s. The resistively heated test piece is comprised of 7 electric heaters with embedded thermocouples. The plant design for the Mo100 to Mo99 targets requires sharp bends and geometry changes in the helium flow tube immediately before and after the target. An idealized fully developed flow configuration with straight entry and exit will be tested and compared with an option that employs rectangular tubing to make the bend at a radius consistent with and practical for the actual plant design. The current plant design, with circular tubing and a sudden contraction to rectangular just prior to target entrance, will also be tested. This requires some modification of the test piece, as described in the report.

42 ENGINEERING↗

PDCI Wide-Area Damping Control: PSLF Simulations of the 2016 Open and Closed Loop Test Plan

To demonstrate and validate the performance of the wide-are a damping control system, the project plans to conduct closed-loop tests on the PDCI in summer/fall 2016. A test plan details the open and closed loop tests to be conducted on the P DCI using the wide-area damping control system. To ensure the appropriate level of preparedness, simulations were performed in order to predict and evaluate any possible unsafe operations before hardware experiments are attempted. This report contains the result s from these simulations using the power system dynamics software PSLF (Power System Load Flow, trademark of GE). The simulations use the WECC (Western Electricity Coordinating Council) 2016 light summer and heavy summer base cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Closed Loop Short Rotation Woody Biomass Energy Crops

CRC Development LLC is pursuing commercialization of shrub willow crops to evaluate and confirm estimates of yield, harvesting, transportation and renewable energy conversion costs and to provide a diverse resource in its supply portfolio.The goal of Closed Loop Short Rotation Woody Biomass Energy Crops is supply expansion in Central New York to facilitate the commercialization of willow biomass crops as part of the mix of woody biomass feedstocks for bioenergy and bioproducts. CRC Development LLC established the first commercial willow biomass plantation acreage in North America was established on the Tug Hill in the spring of 2006 and expanded in 2007. This was the first 230- acres toward the goal of 10,000 regional acres. This project replaces some 2007-drought damaged acreage and installs a total of 630-acre new planting acres in order to demonstrate to regional agricultural producers and rural land-owners the economic vitality of closed loop short rotation woody biomass energy crops when deployed commercially in order to motivate new grower entry into the market-place. The willow biomass will directly help stabilize the fuel supply for the Lyonsdale Biomass facility, which produces 19 MWe of power and exports 15,000 pph of process steam to Burrows Paper. This project will also provide feedstock to The Biorefinery in New York for the manufacture of renewable, CO2-neutral liquid transportation fuels, chemicals and polymers. This project helps end dependency on imported fossil fuels, adds to region economic and environmental vitality and contributes to national security through improved energy independence.

09 BIOMASS FUELS↗

Numerical simulation of a full-loop circulating fluidized bed under different operating conditions

Both experimental and computational studies of the fluidization of high-density polyethylene (HDPE) particles in a small-scale full-loop circulating fluidized bed are conducted. Experimental measurements of pressure drop are taken at different locations along the bed. The solids circulation rate is measured with an advanced Particle Image Velocimetry (PIV) technique. The bed height of the quasi-static region in the standpipe is also measured. Comparative numerical simulations are performed with a Computational Fluid Dynamics solver utilizing a Discrete Element Method (CFD-DEM). This paper reports a detailed and direct comparison between CFD-DEM results and experimental data for realistic gas-solid fluidization in a full-loop circulating fluidized bed system. The comparison reveals good agreement with respect to system component pressure drop and inventory height in the standpipe. In addition, the effect of different drag laws applied within the CFD simulation is examined and compared with experimental results.

01 COAL, LIGNITE, AND PEAT↗

Resistively Heated Target Tests Using Helium Flow Loop

A helium flow and heat transfer experiment has been conducted using the helium flow loop facility at the Los Alamos National Laboratory. In order to replicate the helium cooled Mo-100 plant design disks during beam heating, an array of resistive heaters were placed within the helium flow loop, and cooled via helium. The resistively heated test piece is comprised of seven ceramic electric heaters with embedded thermocouples allowing temperature measurements of each heater.Computation fluid dynamic (CFD) simulations and analysis from theory are compared to the experiment results in order to have predictable capabilities for future experiments.

42 ENGINEERING↗

Integrating guiding center motion in loop space

The purpose of this report is to demonstrate how the slow motion of loops coincides with GC dynamics and to report of Python implementation of loop space integrator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of a Versatile Experimental Salt Irradiation Loop (VESIL) inside the Advanced Test Reactor

A Versatile Experimental Salt Irradiation Loop (VESIL) is under investigation at Idaho National Laboratory. An initial feasibility study was conducted for potential deployment inside the Advanced Test Reactor (ATR). Historical salt-irradiation tests are reviewed and summarized in this report. The study also surveys available instrumentation for this type of application and identifies key design and testing requirements. Neutronic analysis was performed in different ATR position for various salt candidates using MCNP6 and ORIGEN-6.2. The results indicate that both the B and I-positions are suitable for VESIL. The B-position allows for accelerated testing in light of its higher flux, but its smaller volume may be detrimental for a flowing loop. The O-position flux level was found to be insufficient for the purposes of this experiment; it is not recommended. In all the different salt candidates investigated, both the B and I-positions are found to able to reach adequate burnup conditions that are representative of the operating conditions inside proposed molten-salt reactor concepts.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Coal-fueled Pressurized Chemical Looping Combustion with a Spouting Fluidized Bed

The goal of this final project report is to comprehensively summarize the work conducted on project DE-FE0025098. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UKy-CAER) (Recipient) has developed a coal-based combined cycle integrated with a pressurized chemical looping combustion (PCLC) technology to achieve high plant efficiency while capturing CO 2 at low cost. The project involved the design, fabrication, commissioning, parametric testing, and performance validation of the spouted bed approach as coal feeding to narrow the major near-term technical gaps that impede the application of PCLC into solid fuel and scale-up. Specifically, UKy-CAER provided detailed front-end design of a 50 kWth PCLC facility, produced approximately 500 lbs of oxygen carrier (OC) from industrial by-product, Red Mud in addition to commercially available ilmenite, and completed a 70+ hour-long experimental campaign to evaluate the coal feed system and performance and flexibility of the 50 kWth facility with various coal, operating pressures, fluidization agent, and OCs. Project results verified UKy-CAER’s proposed approach to address the major technical gaps of solid-fueled PCLC technology which includes: (1) cost-effective materials for OCs with high reactivity, cyclic capacity, chemical stability, and high resistance to agglomeration with coal ash; (2) fast reaction rates during solid-solid chemical looping combustion (CLC) for reduction of the OC inventory and reactor size; (3) simple and effective ash separation from binary mixtures of the OCs and solid fuel ash; (4) spouting bed coal feeding to suppress OC agglomeration in the reducer resulting from the initial coal devolatilization step, coal tar formation; and (5) pollutant removal to avoid sulfur accumulation in the system or their emission into the hot spent air stream which could result in a second train for SOx removal and potentially cause failure of the flue gas turbine blade. UKy-CAER’s economical cycling material and novel spouted bed reducer configuration shows promise, as summarized in this report, as an effective means for improved plant efficiency with reduced process complexity.

01 COAL, LIGNITE, AND PEAT↗

Diamagnetic Loop Testing on DARHT-I

Diamagnetic loops (DML) can be used as a noninvasive method for measurements of beam size in electron beam accelerators that use solenoidal magnetic transport. The loop fundamentally measures the magnetic flux excluded by a diamagnetic object. A comprehensive theory relates the rms beam radius to the excluded flux measured by the DML. We have built, and calibrated a DML apparatus. Recently, this DML has been used to measure the size of the electron beam near the final focus of the DARHT-I flash-radiography accelerator. Results are in agreement with beam transport code predictions. In this article, we review and summarize the construction, calibration, and electron-beam testing of this DML.

43 PARTICLE ACCELERATORS↗

Optimized Test Section for Helium Flow Loop Experiment

Phase 3 of this project uses the knowledge and techniques gained from Phase 1 and Phase 2. The first outcome of Phase 3 is a new test section which can be manufactured and tested in the Helium Flow Loop Experiment to verify the results of the optimization study. The second outcome of Phase 3 is analyzing the features of this design and determining its performance under simulated TBM conditions: heat flux, pressure, mass flow rate, one-sided and volumetric heating. This will be accomplished by first using the results from the Phase 1 analyses and then applying the optimization strategy from Phase This phase uses the STAR-CCM+ Design Manager tool to apply the optimization strategy to the Helium Flow Loop Experiment (HFLE). The optimization algorithm used by the Design Manager tool is Simultaneous Hybrid Exploration that is Robust, Progressive, and Adaptive (SHERPA search algorithm). In addition to demonstrating the optimization features, a simple parameter sweep is also included in this phase. This report details the applied single objective optimization.

42 ENGINEERING↗

Human-in-the-loop Sensing and Control for Commercial Building Energy Efficiency and Occupant Comfort

Most of the existing heating, ventilation and air conditioning (HVAC) systems in commercial buildings operate in a conservative manner by assuming maximum occupancy in each room during pre-specified periods of the week, leading to significant energy being wasted as rooms are over-conditioned compared to the actual requirements of the occupants. Though critical, our understanding of occupancy patterns and thermal comfort needs of the occupants in commercial buildings is lacking and it is well known that both of these quantities are stochastic and time-varying, thus requiring sensing solutions to estimate them. This project had the goal of designing, implementing and evaluating a hardware and software solution to ameliorate this challenge. In particular, a depth camera (one whose pixels reveal distance from the camera as opposed to color values) placed on doorways is used to detect entrance and exit events from thermal zones in the building, and thereby estimate their occupancy levels. This information is then fed to a novel control algorithm that can, through interactions with the HVAC system, learn how to provide control inputs that maximize comfort and minimize energy waste. The resulting system represents a significant improvement over existing controllers for commercial HVAC systems and allowed us to improve our understanding of the design of future human-in-the-loop control solutions. For this solution to be feasible, the project had target metrics for its performance and cost. In particular, entrance and exit events for occupants moving about the building would need to be detected with an accuracy higher than 97%; and the resulting control inputs derived from this information would need to lead to approximately 10% energy savings compared to a schedule-based controller. Furthermore, regarding the final hardware design, the project had a target bill of materials (BOM) cost for the sensing solution of less than US$200 per unit while using less than 25W of power on average. All of these target metrics were met or exceeded by our final proposed solution. We performed evaluations by deploying the system in over 20 rooms of different types across 6 commercial buildings in Pittsburgh, PA over the course of three years, and performing targeted controlled experiments to test its performance along the different metrics. The human-in-the-loop control solutions (both hardware and software) developed through this project are expected to lead to significant improvements in the comfort and energy efficiency of HVAC systems used in commercial buildings. The insights we developed through the project pave the way to HVAC systems that can condition interior spaces according to their real-time utilization and the thermal comfort needs of the occupants, thereby reducing energy use. They also open up a new learning-based way of configuring HVAC controllers without having to manually fine-tune them for each building. These innovations can significantly increase the adoption of novel control solutions by the industry and thereby save resources and reduce costs of operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Correcting Diamagnetic-Loop Measurements for Beam Corkscrew Motion

Diamagnetic loops (DML) are used as a non-invasive method for measurements of beam size in electron beam accelerators that use solenoidal magnetic transport. The loop fundamentally measures the magnetic flux excluded by a diamagnetic object. One of the sources of background in these measurements is the flux produced by a straight filamentary current that is offset from the axis and tilted in the plane orthogonal to the offset. This was only a small effect in our experiments, because the beam was steered to be centered on average at the DML. However, we devoted some time to understanding and quantifying the effect, and we recount that effort in this report.

43 PARTICLE ACCELERATORS↗

Biomass Gasification for Chemicals Production Using Chemical Looping Techniques (Final Report)

The Ohio State University (OSU) is investigating the Biomass to Syngas (BTS) chemical looping technology to produce syngas for chemical production applications from biomass under US Department of Energy (DOE) Award #DE-EE0007530. The BTS process aligns with the programmatic area of interest of “Conversion, via biological, thermal, catalytic or chemical means, of acceptable feedstocks into advanced biofuels and/or biobased products including intermediate and end-use products”. Compared to conventional biomass gasification processes, the BTS process eliminates the need for air separation units and tar reforming reactors, which leads to energy efficiency improvement and capital cost reduction. The overall objective is to ascertain the potential of biomass gasification based on the chemical looping technique through mitigation of the possible techno-economic challenges in the steps of scale up for commercialization. The scope of work consists of 1) designing, constructing and operating a 10 kWth commercially scalable sub-pilot BTS system and; 2) completing a comprehensive techno-economic analysis (TEA) of the BTS process using methanol production as an example. Over the course of the project, the project team completed the design, fabrication, and operation of a 10 kWth sub-pilot scale test unit for the BTS process. Corn cob and wood pellets were successfully tested in the unit for high purity syngas generation in extended test campaigns that totals over 200 hours. Syngas purity (H2 and CO) of >70% was achieved with a CH 4 concentration of <6%. The H 2 /CO ratio was greater than 1.8. A comprehensive techno-economic analysis was performed to compare the BTS process and a reference indirectly heated gasification process for methanol synthesis. The result, updated with experimental results for BTS process performance, shows a methanol required selling price (MSP) of $\$ $1.15/gal, compared to $1.28/gal for the reference case.

08 HYDROGEN↗

Third Harmonic Generator Optics Loop Transportation and Handling

The National Ignition Facility (NIF) uses crystal optics made from Potassium Di-Hydrogen Phosphate (KDP) for frequency conversion, changing the fundamental wavelength of 1053 nm to the third harmonic at 351 nm. The crystal optics are manufactured at a vendor and shipped to Lawrence Livermore National Laboratory (LLNL) where they are measured, mitigated, cleaned, coated, and placed into line replaceable units (LRUs) in the Optics Processing Facility (OPF) clean room and transported to the NIF where they are stored under Nitrogen purge until they are installed in the beamline. The KDP crystal optics are sensitive to humidity and temperature, so they are stored under Nitrogen purge providing a clean and dry environment. The sensitivity to the environment and the brittle nature of the crystals makes transportation and handling (T&H) challenging. Coupled with challenges in holding the crystal optics in the LRU to not distort the optic, there is a balance between T&H and fixturing the optic in the laser system. The purpose of the LRU is to make the optics interchangeable allowing for a relatively quick interchange. Kinematic mounts and ceramic frames aid in making this possible. Optics in the NIF that are frequently changed out have an established recycle loop. The loop for an optic can be complex depending on the amount of processing and rework necessary. Some optics can’t be reconditioned so they are replaced with new optics.

47 OTHER INSTRUMENTATION↗

Molten Salt Loop Testing of Sensors and Off-Gas Components: FY23 progress

The Liquid Salt Test Loop (LSTL) at the US Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL) was developed to demonstrate technology for high-temperature fluoride salt systems (Figure 1). The LSTL is primarily constructed using Inconel 600 alloy and operates at temperatures of up to 700°C. The facility is loaded with 165 kg of LiF-NaF-KF salt (FLiNaK). This salt provides a relevant test environment for de-risking technology while avoiding the costs and hazards associated with beryllium-based or uranium-bearing salts. FLiNaK is also an advantageous salt for the secondary side of molten salt reactors. The facility’s major components include a centrifugal pump for salt circulation, an air-based heat exchanger to reject heat, a suite of instrumentation, and trace heating to prevent salt freezing. Additional heating is available through an induction heater rated at 200 kW. The relatively large heating and cooling capability enables the formation of a temperature gradient across the loop (i.e., a hot and a cold side), which is important for chemistry and corrosion studies. The LSTL is a unique US capability for high-temperature molten halide salt testing. Although some efforts are underway at universities, the LSTL’s scale, co-located purification system, and relatively large power differentiates it from other testing systems. Furthermore, unlike efforts within industry, access to the DOE-supported facility and communication of results, which are generally disseminated publicly, result in a broad significance in the molten salt reactor community.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Puck Loop Seal (Final Project Technical Report)

Sandia National Laboratories (SNL) is advancing technical capabilities used in passive loop seals. The “Puck” seal used a set of International Atomic Energy Agency (IAEA) requirements for new passive loop seals published in 2020 as a design guide. The seal is based on an oxygen-sensitive inner mixture encased in an oxygen-impermeable shell, is monolithic rather than two-part, incorporates self-capturing wire features, contains colored water beads and bubbles formed during processing as unique identifiers (UIDs), and visually indicates tamper (whether from seal body penetration or from seal wire removal) by irreversibly changing the seal body from multi-colored to black. This paper will provide details on the design, development, and testing of Puck seal prototypes.

42 ENGINEERING↗

Technoeconomic Analysis of a Direct Air Capture System Utilizing a Looped CaCO3/Ca(OH)2 Process

This presentation reports preliminary results from a screening level techno-economic analysis of a looped CaCO3/Ca(OH)2 direct air capture process. Preliminary results reveal that the looped CaCO3/Ca(OH)2 process may be cost competitive with solvent- and sorbent-based DAC technologies. Results from a detailed sensitivity analysis revealing multiple avenues for system optimization and cost reduction are presented.

Homsy, Sally↗