Development of Novel Method for Rapid Extract of Radionuclides from Solution using Polymer Ligand Film [Dissertation]

Accurate and fast determination of the activity of radionuclides in a sample is critical for nuclear forensics and emergency response. Radioanalytical techniques are well established for radionuclides measurement, however, they are slow and labor intensive, requiring extensive radiochemical separations and purification prior to analysis. With these limitations of current methods, there is great interest for a new technique to rapidly process samples. This dissertation describes a new analyte extraction medium called Polymer Ligand Film (PLF) developed to rapidly extract radionuclides. Polymer Ligand Film is a polymer medium with ligands incorporated in its matrix that selectively and rapidly extract analytes from a solution. The main focus of the new technique is to shorten and simplify the procedure necessary to chemically isolate radionuclides for determination by alpha spectrometry or beta counting.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel tri-modal defect structure in Nb-doped MOCVD YBa2Cu3O7: A paradigm for pinning landscape control

Immobilization of vortices, or flux pinning, is both an enduring scientific issue and one of the most important problems in optimizing high temperature superconductors (HTS) for commercial use. Here, we demonstrate a practical approach to the creation of a multi-modal flux pinning landscape in YBa2Cu3O7 (YBCO) films employing an industrially scalable metal organic chemical vapor deposition technique. Through controlled additions of Nb, we have achieved a novel distribution of crystallographic defects that immobilize (pin) vortices in the YBCO matrix. That is, with only the addition of a single dopant element, a tri-modal defect structure that threads through the YBCO matrix laterally (parallel to the ab planes of YBCO), vertically (parallel to the YBCO c-axis), and isotropically in the form of random spherical defects is induced. For optimally doped samples, the influence of these multi-modal nanocrystalline defect structures on the flux pinning properties manifests itself as a superior improvement in the critical current density (Jc) for all magnetic field orientations. The results demonstrate the possibility of achieving an ideal flux pinning landscape (from an orientation and strength viewpoint), which permits the design of HTS wires with fully-tuneable properties by processes suitable for large-scale manufacturing.

Aytug, Tolga↗

A Monte Carlo Technique to Estimate Emissions from R&D Facilities

The Pacific Northwest National Laboratory (PNNL) operates multidisciplinary laboratory Research and Development (R&D) facilities for the U. S. Department of Energy and sampled air chemical emissions from some of these facilities from 1998 until 2008. Although sampling was not required for environmental compliance, PNNL conducted sampling to provide data to compare estimated release fractions to those used for emissions estimates and to verify that methods used to determine compliance with air regulations and permits conservatively predict actual emissions. Sampling also identifies and quantifies air toxics emitted to compare with compliance limits established by the State. The sampling data provides a unique opportunity to quantify emissions and investigate factors potentially impacting emissions. Previous work using this data set include a paper by Woodruff, Benar, and McCarthy1 who summarized the compliance approach used by PNNL and described sampling and analytical measurements for the first sampling campaigns. Conclusions reported in the paper were that none of the measurements of the target compounds exceeded a State acceptable source impact level (ASIL)2 even using significant overestimation factors, and that an average release fraction calculated from the data provided reasonable validation of the factor used in compliance assessments. Other reports using the data include the following: • A metric was developed by Ballinger, Duchsherer, and Metoyer3 to compare chemical signatures. The analysis found similarities in chemical signatures from three of the buildings but a markedly different signature from the fourth building. • A method was developed and used on the data to rank the chemical compounds that present the greatest risk to a potential downstream receptor and to determine whether the sampling parameters and detection limits provided sufficient resolution to verify compliance at potential receptor locations.4 • The stack data from one of the buildings was analyzed using a statistical technique called Positive Matrix Factorization (PMF) to identify the number and composition of major contributing sources to measured stack concentrations.5 In this analysis, a method is described that uses a Monte Carlo technique to produce a distribution of emission estimates from the measured data. The method is applied to one of the chemicals previously identified as more significant than others using the ranking process.4 Variations on the method are investigated and compared to determine their effects on the emission estimates.

Laboratory, air chemical emissions, volatile organ↗

DISSOLUTION OF NEPTUNIUM OXIDE RESIDUES

This report describes the development of a dissolution flowsheet for neptunium (Np) oxide (NpO{sub 2}) residues (i.e., various NpO{sub 2} sources, HB-Line glovebox sweepings, and Savannah River National Laboratory (SRNL) thermogravimetric analysis samples). Samples of each type of materials proposed for processing were dissolved in a closed laboratory apparatus and the rate and total quantity of off-gas were measured. Samples of the off-gas were also analyzed. The quantity and type of solids remaining (when visible) were determined after post-dissolution filtration of the solution. Recommended conditions for dissolution of the NpO{sub 2} residues are: Solution Matrix and Loading: {approx}50 g Np/L (750 g Np in 15 L of dissolver solution), using 8 M nitric acid (HNO{sub 3}), 0.025 M potassium fluoride (KF) at greater than 100 C for at least 3 hours. Off-gas: Analysis of the off-gas indicated nitric oxide (NO), nitrogen dioxide (NO{sub 2}) and nitrous oxide (N{sub 2}O) as the only identified components. No hydrogen (H{sub 2}) was detected. The molar ratio of off-gas produced per mole of Np dissolved ranged from 0.25 to 0.4 moles of gas per mole of Np dissolved. A peak off-gas rate of {approx}0.1 scfm/kg bulk oxide was observed. Residual Solids: Pure NpO{sub 2} dissolved with little or no residue with the proposed flowsheet but the NpCo and both sweepings samples left visible solid residue after dissolution. For the NpCo and Part II Sweepings samples the residue amounted to {approx}1% of the initial material, but for the Part I Sweepings sample, the residue amounted to {approx}8 % of the initial material. These residues contained primarily aluminum (Al) and silicon (Si) compounds that did not completely dissolve under the flowsheet conditions. The residues from both sweepings samples contained minor amounts of plutonium (Pu) particles. Overall, the undissolved Np and Pu particles in the residues were a very small fraction of the total solids.

08 HYDROGEN↗

Measurements of single top quark production cross sections and |V tb | in pp̄ collisions at √s=1.96 TeV

We present measurements of production cross sections of single top quarks in pp̄ collisions at √s=1.96 TeV in a data sample corresponding to an integrated luminosity of 5.4 fb⁻¹ collected by the D0 detector at the Fermilab Tevatron Collider. We select events with an isolated electron or muon, an imbalance in transverse energy, and two, three, or four jets, with one or two of them containing a bottom hadron. We obtain an inclusive cross section of σ(pp̄→tb+X,tqb+X)=3.43± 0.73 0.74 pb and use it to extract the CKM matrix element 0.79<|V tb |≤1 at the 95% C.L. We also measure σ(pp̄→tb+X)=0.68±0.380.35 pb and σ(pp̄→tqb+X)=2.86± 0.69 0.63 pb when assuming, respectively, tqb and tb production rates as predicted by the standard model.

Abazov, V. M.↗

SU-F-J-158: Respiratory Motion Resolved, Self-Gated 4D-MRI Using Rotating Cartesian K-Space Sampling

Purpose: Dynamic MRI has been used to quantify respiratory motion of abdominal organs in radiation treatment planning. Many existing 4D-MRI methods based on 2D acquisitions suffer from limited slice resolution and additional stitching artifacts when evaluated in 3D{sup 1}. To address these issues, we developed a 4D-MRI (3D dynamic) technique with true 3D k-space encoding and respiratory motion self-gating. Methods: The 3D k-space was acquired using a Rotating Cartesian K-space (ROCK) pattern, where the Cartesian grid was reordered in a quasi-spiral fashion with each spiral arm rotated using golden angle{sup 2}. Each quasi-spiral arm started with the k-space center-line, which were used as self-gating{sup 3} signal for respiratory motion estimation. The acquired k-space data was then binned into 8 respiratory phases and the golden angle ensures a near-uniform k-space sampling in each phase. Finally, dynamic 3D images were reconstructed using the ESPIRiT technique{sup 4}. 4D-MRI was performed on 6 healthy volunteers, using the following parameters (bSSFP, Fat-Sat, TE/TR=2ms/4ms, matrix size=500×350×120, resolution=1×1×1.2mm, TA=5min, 8 respiratory phases). Supplemental 2D real-time images were acquired in 9 different planes. Dynamic locations of the diaphragm dome and left kidney were measured from both 4D and 2D images. The same protocol was also performed on a MRI-compatible motion phantom where the motion was programmed with different amplitude (10–30mm) and frequency (3–10/min). Results: High resolution 4D-MRI were obtained successfully in 5 minutes. Quantitative motion measurements from 4D-MRI agree with the ones from 2D CINE (<5% error). The 4D images are free of the stitching artifacts and their near-isotropic resolution facilitates 3D visualization and segmentation of abdominal organs such as the liver, kidney and pancreas. Conclusion: Our preliminary studies demonstrated a novel ROCK 4D-MRI technique with true 3D k-space encoding and respiratory motion self-gating. The technique leads to high-resolution and artifacts-free 4D images for improved abdominal organ motion studies. K.S acknowledges funding support from NIH R01CA188300.

60 APPLIED LIFE SCIENCES↗

Infrared photoluminescence from GeSi nanocrystals embedded in a germanium–silicate matrix

We investigate the structural and optical properties of GeO/SiO{sub 2} multilayers obtained by evaporation of GeO{sub 2} and SiO{sub 2} powders under ultrahigh vacuum conditions on Si(001) substrates. Both Raman and infrared absorption spectroscopy measurements indicate the formation of GeSi nanocrystals after postgrowth annealing at 800°C. High-resolution transmission electron microscopy characterizations show that the average size of the nanocrystals is about 5 nm. For samples containing GeSi nanocrystals, photoluminescence is observed at 14 K in the spectral range 1500–1600 nm. The temperature dependence of the photoluminescence is studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sources of Li isotope bias during SIMS analysis of standard glasses

The 7 Li/ 6 Li ratios in fourteen USGS, MPI-DING, and NIST glass reference materials (RMs) were analyzed by LG-SIMS to assess compositional matrix effects, evaluate RM δ 7 Li homogeneity, and calculate the useful yield of lithium in silicate glasses. The analyzed RMs cover a range of SiO 2 contents from 45.5 to 75.6% (komatiite to rhyolite), the largest compositional range yet evaluated for δ 7 Li matrix effects. We observe a matrix-induced bias (matrix effect) of up to 18‰ over the studied range that linearly correlates with SiO 2 content, demonstrating that SiO 2 content is a critical factor that must be considered when using silicate glasses to standardize for silicate samples of unknown δ 7 Li composition. All RMs were found to be sufficiently reproducible to aid in standardization of variable SiO 2 contents and appear isotopically homogeneous at the precision of our measurements. Lithium ionizes very efficiently in these RMs, with measurable yields >5% in all fused-rock RMs and >15% in low SiO 2 fused-rock RMs measured at high beam intensities. Finally, fused-rock RMs ionize lithium 2-3x more efficiently than synthetic glass RMs, which may be related to differences in major oxide chemistry and the reduced nature of the synthetic glasses relative to their fused counterparts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Constraining primordial non-Gaussianity with DESI 2024 LRG and QSO samples

We analyse the large-scale clustering of the Luminous Red Galaxy (LRG) and Quasar (QSO) sample from the first data release (DR1) of the Dark Energy Spectroscopic Instrument (DESI). In particular, we constrain the primordial non-Gaussianity (PNG) parameter f NL loc via the large-scale scale-dependent bias in the power spectrum using 1,631,716 LRGs (0.6 < z < 1.1) and 1,189,129 QSOs (0.8 < z < 3.1). This new measurement takes advantage of the enormous statistical power at large scales of DESI DR1 data, surpassing the latest data release (DR16) of the extended Baryon Oscillation Spectroscopic Survey (eBOSS). For the first time in this kind of analysis, we use a blinding procedure to mitigate the risk of confirmation bias in our results. We improve the model of the radial integral constraint proposing an innovative technique allowing the correction through the window matrix convolution. We also carefully test the mitigation of the dependence of the target selection on the photometry qualities by incorporating an angular integral constraint contribution to the window function, and validate our methodology with the blinded data. Finally, combining the two samples, we measure f NL loc = -3.6 -9.1 +9.0 at 68% confidence, where we assume the universality relation for the LRG sample and a recent merger model for the QSO sample about the response of bias to primordial non-Gaussianity. Adopting the universality relation for the PNG bias in the QSO analysis leads to f NL loc = 3.5 -7.4 +10.7 at 68% confidence. Due to restricted selection in the LRG sample, the inclusion of the LRGs allows for 10% improvement. This measurement is the most precise determination of primordial non-Gaussianity using large-scale structure to date, surpassing the latest result from eBOSS by a factor of 2.3.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards High-Resolution Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass Spectrometry Coupled to Shear Force Microscopy

Constant mode ambient mass spectrometry imaging (MSI) of tissue sections with high lateral resolution of better than 10 μm was performed by combining shear force microscopy with nanospray desorption electrospray ionization (nano-DESI). Shear force microscopy enabled precise control of the distance between the sample and nano-DESI probe during MSI experiments and provided information on sample topography. Proof-of-concept experiments were performed using lung and brain tissue sections representing spongy and dense tissues, respectively. Topography images obtained using shear force microscopy were comparable to the results obtained using contact profilometry over the same region of the tissue section. Variations in tissue height were found to be dependent on the tissue type and were in the range of 0–5 μm for lung tissue and 0–3 μm for brain tissue sections. Ion images of phospholipids obtained in this study are in good agreement with literature data. Normalization of nano-DESI MSI images to the signal of the internal standard added to the extraction solvent allowed us to construct high-resolution ion images free of matrix effects. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing Solids in Residual Wastes from Single-Shell Tanks at the Hanford Site.

Solid-phase characterization methods have been used in an ongoing study of residual wastes (i.e., waste remaining after final retrieval operations) from underground single-shell storage tanks 241-C-103, 241 C 106, 241-C-202, 241-C-203, and 241-S-112 at the U.S. Department of Energy’s Hanford Site in Washington State. The results of studies completed to date show variability in the compositions of those residual wastes and the compositions, morphologies, and crystallinities of the individual phases that make up these wastes. These differences undoubtedly result from the various waste types stored and transferred into and out of each tank and the different sluicing and retrieval operations used for waste retrieval. The studies indicate that these residual wastes are chemically-complex assemblages of crystalline and amorphous solids that contain contaminants as discrete phases and/or coprecipitated within oxide/hydroxide phases. Depending on the specific tank, various solids (e.g., gibbsite; böhmite; dawsonite; cancrinite; Fe oxides/hydroxides such as hematite, goethite, and maghemite; rhodochrosite; lindbergite; whewellite; nitratine; and numerous amorphous or poorly crystalline phases) have been identified by X-ray diffraction and scanning electron microscopy/energy dispersive X-ray spectroscopy in residual wastes studied to date. The studies also show that contact of residual wastes with Ca(OH)2- and CaCO3-saturated aqueous solutions, which were used as surrogates for the compositions of pore-fluid leachants derived from young and aged cements, respectively, may alter the composition of solid phases present in the contacted wastes. Iron oxides/hydroxides have been identified in all residual wastes studied to date. They occur in these wastes as discrete particles, particles intergrown within a matrix of other phases, and surface coatings on other particles or particle aggregates. These Fe oxides/hydroxides typically contain trace concentrations of other transition metals, such Cr, Mn, Ni, Pb, and/or U. Recent analyses of residual waste from 241-C-103 have revealed the presence of Tc-containing Fe oxide/hydroxide particles, which is believed to be the first direct evidence of Tc in solid phases in actual samples of Hanford pre-final retrieval tank waste or post-final retrieval residual waste. The presence of mineralized coatings, such as Fe oxides/hydroxides or reaction products precipitated from contact with cement pore fluids, on contaminant-containing particles could decrease their rate of dissolution, thereby delaying the release of contaminants until the coatings dissolve sufficiently to expose the underlying matrix to infiltrating pore fluids. Certain key cross-cutting geochemical processes and solid phase characteristics important to contaminant waste release are becoming evident, now that residual wastes have been studied from several single-shell tanks. As more residual tank wastes are characterized in terms of composition and contaminant release, it is anticipated that common characteristics with respect to the type of wastes stored in the tanks will become evident. This may allow the grouping of tanks into general categories with certain common chemical features and contaminant release characteristics - an important goal because complete characterization of residual wastes from all 149 single-shell storage tanks is not practical. Additionally, information garnered from residual waste characterization activities can be used to optimize future waste retrieval operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stress field analysis in a stony meteorite under thermal fatigue and mechanical loadings

A micromechanical approach relying on 3D image-based finite element (FE) models, together with experimental testing, is employed to investigate the stress distribution in an L6 ordinary chondrite's microstructure subjected to thermal and mechanical loadings. An in-situ X-ray micro-computed tomography (micro-CT) setup capable of applying thermal and mechanical loads shed light on crack initiation mechanisms in chondrite samples. Micro-CT images were further used to reconstruct realistic microstructural models of the samples, which were transformed into FE models using an automated non-iterative mesh generation algorithm. FE approximation of stress fields showed that under mechanical loads, the stress often concentrates in matrix-particle interfacial regions with higher curvatures. Furthermore, this could result in the nucleation and eventually propagation of cracks in such regions. However, when the thermal cycling takes place, the stress concentrates more uniformly along with particle interfaces, resulting in their debonding from the surrounding matrix. Both observations were verified by experimental data obtained from in-situ micro-CT imaging.

36 MATERIALS SCIENCE↗

The involvement of regulated in development and DNA damage response 1 (REDD1) in the pathogenesis of intervertebral disc degeneration

Regulated in development and DNA damage response 1 (REDD1) is an evolutionarily conserved, ubiquitous protein that responds to various cell stresses. Studies have proved REDD1 is involved in many diseases, such as osteoarthritis and cancer. The present study aimed to investigate the potential role of REDD1 in the pathogenesis of intervertebral disc degeneration (IDD). Analysis of clinical tissue samples showed REDD1 expression was up-regulated during IDD and was correlated with the grade of disc degeneration. Overexpression of REDD1 in normal human nucleus pulposus (NP) cells resulted in extracellular matrix (ECM) degeneration. Further, we investigated the function of REDD1 using a serum deprivation-induced IDD vitro model and found that REDD1 was up-regulated in a temporal manner. However, hypoxia abolished this increase through down-regulation of NF-κB. Knockdown of REDD1 or NF-κB by si-RNA significantly rescued ECM from degeneration both in normoxia and hypoxia. In addition, NF-κB/REDD1 mediated the protection of hypoxia from serum deprivation-induced apoptosis and autophagy in NP cells. These results suggest that REDD1 might play a pivotal role in IDD pathogenesis, thereby potentially providing a new therapeutic target for IDD treatment.

60 APPLIED LIFE SCIENCES↗

Time-Domain Simulations of Transient Species in Experimentally Relevant Environments

Simulating the spectroscopic properties of short-lived thermal and photochemical reaction intermediates and products is a challenging task, as these species often feature atypical molecular and electronic structures. The complex environments in which such species typically reside in practice add further complexity to the problem. Herein, we tackle this problem in silico using ab initio molecular dynamics (AIMD) simulations, employing iso-CHBr3, namely H(Br)C-Br-Br, as a prototypical system. This species was chosen because it features both a non-conventional C-Br-Br bonding pattern, as well as a strong dependence of its spectral features on the local environment in which it resides, as illustrated in recent experimental reports. The spectroscopic properties of iso-CHBr3 were measured by several groups that captured this transient intermediate in the photochemistry of CHBr3 in the gas phase, in rare gas matrices at 5K, and in solution under ambient laboratory conditions. We simulate the UV-Vis and IR spectra of iso-CHBr3 in all three media, including a Ne cluster (64 atoms) and a methylcyclohexane cage (14 solvent molecules) representative of the matrix isolated and solvated species. We exclusively perform fully quantum mechanical static and dynamic simulations. By comparing our condensed phase simulations to their experimental analogues, we stress the importance of (i) conformational sampling, even at cryogenic temperatures, and (ii) using a fully quantum mechanical description of both solute and bath to properly account for the experimental observables.

Environmental Molecular Sciences Laboratory↗

Polysiloxane Scintillators for Efficient Neutron and Gamma-Ray Pulse Shape Discrimination

Plastic scintillators based on thermoplastics, such as polystyrene and poly(vinyl toluene) (PVT), are capable of neutron and γ radiation detection via pulse shape discrimination (PSD) when overdoped with select fluorescent molecules. This class of plastic scintillator has been extensively studied but is limited to applications suitable for thermoplastics. For applications requiring flexibility, scintillators composed of elastomers, such as polysiloxanes, offer an alternative to PVT scintillators. Polysiloxane scintillators are inherently flexible and have a short processing time on the order of 3 h in air and equivalent or better detection capability at reduced doping concentration (<5 wt %). This work presents polysiloxane-based scintillators, containing only 1–5 wt % of 2,5 diphenyl-oxazole (PPO) or 9,9-dimethyl-2-phenyl-9H-fluorene (PhF) as primary dopants and 9,9-dimethyl-2,7-distyryl-9H-fluorene (SFS) as a wavelength shifter. A 5 wt % PPO polysiloxane sample had improved neutron and gamma ray PSD and comparable light yield than EJ-299-33 tested under the same conditions, i.e., figure of merit (FoM) of 1.33 ± 0.03 at 450 keV ee and light yield of 94% relative to EJ-299-33. The 5 wt % PhF-polysiloxane sample had a higher light yield, 144% of EJ-299-33 but lower FoM under the same conditions (FoM of 1.09 ± 0.03). Furthermore, this work highlights the potential of polysiloxanes as a matrix for PSD capable plastic scintillators.

36 MATERIALS SCIENCE↗

Focused ion beam processing of organic crystal (TMTSF){sub 2}PF{sub 6}. A combined conducting probe atomic force microscopy and secondary ion mass spectrometry study

We study the behavior of the organic material (TMTSF){sub 2}PF{sub 6} (TMTSF: tetramethyl tetraselena fulvalene) under focused Ga{sup +} ion beam impact using conducting probe atomic force microscopy (CP-AFM) and secondary ion mass spectrometry. The (TMTSF){sub 2}PF{sub 6} crystals are exposed to a 25 keV focused ion beam with the sample native surface both perpendicular and slightly tilted to the incident beam axis, where drastically different etching effects are observed. Moreover, very large ion implantation depth, as compared to conventional substrates, is obtained when the sample surface is set perpendicular to the beam axis, while the implantation depth is much smaller at the tilted angle. This phenomenon is discussed in relation with the sample structure anisotropy. Finally, the transport property modifications of the impact areas are investigated by CP-AFM and discussed in relation with both the crystalline structure and the polarizability of the matrix.

36 MATERIALS SCIENCE↗

Thermally oxidized formation of new Ge dots over as-grown Ge dots in the Si capping layer

A Si-capped Ge quantum dot sample was self-assembly grown via Stranski-Krastanov mode in a molecular beam epitaxy system with the Si capping layer deposited at 300 deg. C. After annealing the sample in an oxygen atmosphere at 1000 deg. C, a structure, namely two layers of quantum dots, was formed with the newly formed Ge-rich quantum dots embedded in the oxidized matrix with the position accurately located upon the as-grown quantum dots. It has been found that the formation of such nanostructures strongly depends upon the growth temperature and oxygen atmosphere. A growth mechanism was proposed to explain the formation of the nanostructure based on the Ge diffusion from the as-grown quantum dots, Ge segregation from the growing oxide, and subsequent migration/agglomeration.

36 MATERIALS SCIENCE↗

Evaluating the presence of porosity in Brazilian archaeological pottery associating x-radiography and PIXE

X-Radiography technique has been used effectively for decades to evaluate and identify differences in homogeneities in samples. It is a simple, fast and non-destructive technique that provides a view of internal structure helping investigating manufacturing details of archaeological ceramics. Characteristics of the paste used in the matrix composition can be derived using PIXE technique through the determination of the major elemental composition allowing the calculation of its expected density. Combining this information with x-ray images is possible to check for differences in the average density of material indicating the presence of homogeneously distributed porosity or temper. The present work evaluates the porosity in a set of native Brazilian pottery sherds that were collected in the Aldeia Lalima archaeological site, located at Mato Grosso do Sul State.

36 MATERIALS SCIENCE↗