Search NASA⌕ Search

SEARCH · Search NASA

Results for “methods - statistical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Enhanced photocatalytic degradation of methylene blue: Preparation of TiO{sub 2}/reduced graphene oxide nanocomposites by direct sol-gel and hydrothermal methods

Highlights: • TiO{sub 2}-RGO nanocomposites presented, in all the cases studied, improved photocatalytic properties compared to bare TiO{sub 2}. • An optimal composition, in terms of TiO{sub 2}/RGO ratio was found in both series nanocomposites. • Nanocomposites of sol-gel method presented improved textural properties than those of hydrothermal method. • Optimization in the preparation, needed to obtain materials with finer properties for effective application in environmental. - Abstract: In this study, two different preparation methods of titanium dioxide nanoparticles/reduced graphene oxide nanocomposites were investigated using direct sol-gel method followed by hydrothermal treatment or simple hydrothermal route. A different amount of graphene (1- 20%) was mixed with TiO{sub 2} for both series of samples in order to improve the photocatalytic activity. The influence of the preparation method on the physico-chemical properties was established by different characterization methods and the photocatalytic degradation of methylene blue (MB) under UV light irradiation was used as test reaction. The highest photocatalytic activity was observed for the nanocomposites containing 10 wt% of graphene. The elimination of MB can reach 93% and 82% for the nanocomposites with 10 wt% graphene prepared by the sol-gel and hydrothermal methods, respectively. These photocatalysts are promising for practical application in nanotechnology.

36 MATERIALS SCIENCE↗

Development of a high-throughput method for processing sponge-stick samples to detect viable Bacillus anthracis spores

Since the national validation of the sponge-stick based method for detection of Bacillus anthracis spores in environmental samples, there have not been focused efforts to address the low throughput nature of the method, which processes only one sample at one time. Sample processing remains a serious bottleneck for rapidly analyzing large numbers of samples expected from a biological warfare attack. Therefore, we developed a high-throughput method to simultaneously process multiple sponge-stick samples to be better prepared for rapid response and recovery after wide area anthrax incidents. In this method, sponges are placed in 50 mL tubes containing 25 mL extraction buffer and shaken to release spores, after which the suspension is recovered for analysis. Here, we determined that an additional extraction step, conducted in the same tubes with 10 mL buffer, further increased spore recovery from sponge-stick by approximately 10 %. We determined that orbital shaking and multi-tube vortexing were both more effective than reciprocating shaking for recovering spores. We conducted simultaneous processing of up to 12 sponge-stick samples and demonstrated comparable spore recovery efficiencies to the traditional low-throughput stomacher-based method (approximately 60 % recovery at 10 2 -spore level and 75 % recovery at 10 4 -spore level for both methods in three replicate experiments, P > 0.05 for two-tailed t-tests for each experiment and spore level). We also demonstrated that our high-throughput method could be integrated with Rapid Viability-Polymerase Chain Reaction (RV-PCR) analysis and could detect levels as low as 40 spores per sponge even when challenged by a PCR particulate contaminant.

Anthrax↗

Comparison of gamma-ray spectral analysis methods for thick-walled UF 6 cylinders

Three data analysis methods were compared for gamma ray spectra collected by planar and coaxial high-purity germanium detectors (HPGe) on thick-walled uranium hexafluoride cylinders. The cylinder contents range from natural to low-enriched uranium (4.95% 235 U). Each spectrum was analyzed with the traditional 185.7 keV enrichment meter method, a 185.7/1001 keV ratio method, and the Fixed Energy Response Function Analysis with Multiple Efficiency (FRAM) software that utilizes low- and high-energy gamma rays and X-rays. When results for all cylinders were compared, the enrichment meter method and the 185.7/1001 keV peak ratio method consistently provided the most accurate data for all detector types. The error on the enrichment calculations analyzed with FRAM did not meet the international target value whereas those calculated with the enrichment meter and ratio method did. Enrichments calculated by FRAM were found to skew to higher values on natural uranium and to lower values on low-enriched uranium. FRAM calculated the least-precise enrichments; replicate analyses of single cylinders resulted in 235 U values that varied by as much as 19%. FRAM does have the significant advantages in that it does not require the use of calibration cylinders, infinite thickness criteria are not necessary, and it can be applied to any HPGe detector. Finally, if calibration cylinders are available, the enrichment meter and 185.7/1001 peak ratio are the recommended methods as they are the most accurate and precise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

252 Cf yield calibration method for nuclear material accountancy and safeguards practitioners

Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the continuous dilatometer method of silicon carbide thermometry for passive irradiation temperature determination

Silicon carbide (SiC) is a primary candidate for passive irradiation temperature monitoring, and continuous dilatometry (CD) has been proposed as the key method for extracting irradiation temperatures from SiC thermometry samples. The CD method was evaluated to determine the sensitivity of the technique to the analysis procedure, as well as its accuracy and precision. Analysis found that the CD method had a ±20 °C sensitivity to the algorithm used to determine the irradiation temperatures. Comparison of the CD method with the continuous length change method for SiC thermometry showed CD is a more viable method of extracting irradiation temperatures. In conclusion, a comparison of irradiation temperatures determined by CD with those from active thermocouple measurements further validated the CD method for accurately and precisely determining irradiation temperatures in materials test reactor irradiations.

36 MATERIALS SCIENCE↗

High precision tests of QCD without scale or scheme ambiguities: The 40th anniversary of the Brodsky–Lepage–Mackenzie method

A key issue in making precise predictions in QCD is the uncertainty in setting the renormalization scale μ r and thus determining the correct values of the QCD running coupling α s (μ r ) at each order in the perturbative expansion of a QCD observable. It has often been conventional to simply set the renormalization scale to the typical scale of the process Q and vary it in the range μ r $\in$ [Q/2, 2Q] in order to estimate the theoretical error. This is the practice of Conventional Scale Setting (CSS). The resulting CSS prediction will however depend on the theorist’s choice of renormalization scheme and the resulting pQCD series will diverge factorially. It will also disagree with renormalization scale setting used in QED and electroweak theory thus precluding grand unification. A solution to the renormalization scale-setting problem is offered by the Principle of Maximum Conformality (PMC), which provides a systematic way to eliminate the renormalization scale-and-scheme dependence in perturbative calculations. The PMC method has rigorous theoretical foundations, it satisfies Renormalization Group Invariance (RGI) and preserves all self-consistency conditions derived from the renormalization group. The PMC cancels the renormalon growth, reduces to the Gell-Mann–Low scheme in the N c → 0 Abelian limit and leads to scale- and scheme-invariant results. The PMC has now been successfully applied to many high-energy processes. In this article we summarize recent developments and results in solving the renormalization scale and scheme ambiguities in perturbative QCD. In particular, we present a recently developed method the PMC ∞ and its applications, comparing the results with CSS. The method preserves the property of renormalizable SU(N)/U(1) gauge theories defined as Intrinsic Conformality (iCF). This property underlies the scale invariance of physical observables and leads to a remarkably efficient method to solve the conventional renormalization scale ambiguity at every order in pQCD. This new method reflects the underlying conformal properties displayed by pQCD at NNLO, eliminates the scheme dependence of pQCD predictions and is consistent with the general properties of the PMC. A new method to identify conformal and β-terms, which can be applied either to numerical or to theoretical calculations is also shown. We present results for the thrust and C-parameter distributions in e + e - annihilation showing errors and comparison with the CSS. We also show results for a recent innovative comparison between the CSS and the PMC ∞ applied to the thrust distribution investigating both the QCD conformal window and the QED N c → 0 limit. In order to determine the thrust distribution along the entire renormalization group flow from the highest energies to zero energy, we consider the number of flavors near the upper boundary of the conformal window. In this flavor-number regime the theory develops a perturbative infrared interacting fixed point. These results show that PMC ∞ leads to higher precision and introduces new interesting features in the PMC. In fact, this method preserves with continuity the position of the peak, showing perfect agreement with the experimental data already at NNLO. We also show a detailed comparison of the PMC ∞ with the other PMC approaches: the multi-scale-setting approach (PMCm) and the single-scale-setting approach (PMCs) by comparing their predictions for three important fully integrated quantities R e+e- , R$_Τ$ and Γ (H→$b\bar{b}$) up to the four-loop accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Cluster-based Method to Map Urban Area from DMSP/OLS Nightlights

Accurate information of urban areas at regional and global scales is important for both the science and policy-making communities. The Defense Meteorological Satellite Program/Operational Linescan System (DMSP/OLS) nighttime stable light data (NTL) provide a potential way to map urban area and its dynamics economically and timely. In this study, we developed a cluster-based method to estimate the optimal thresholds and map urban extents from the DMSP/OLS NTL data in five major steps, including data preprocessing, urban cluster segmentation, logistic model development, threshold estimation, and urban extent delineation. Different from previous fixed threshold method with over- and under-estimation issues, in our method the optimal thresholds are estimated based on cluster size and overall nightlight magnitude in the cluster, and they vary with clusters. Two large countries of United States and China with different urbanization patterns were selected to map urban extents using the proposed method. The result indicates that the urbanized area occupies about 2% of total land area in the US ranging from lower than 0.5% to higher than 10% at the state level, and less than 1% in China, ranging from lower than 0.1% to about 5% at the province level with some municipalities as high as 10%. The derived thresholds and urban extents were evaluated using high-resolution land cover data at the cluster and regional levels. It was found that our method can map urban area in both countries efficiently and accurately. Compared to previous threshold techniques, our method reduces the over- and under-estimation issues, when mapping urban extent over a large area. More important, our method shows its potential to map global urban extents and temporal dynamics using the DMSP/OLS NTL data in a timely, cost-effective way.

Cities↗

Harmonizing solar induced fluorescence across spatial scales, instruments, and extraction methods using proximal and airborne remote sensing: A multi-scale study in a soybean field

Solar-induced chlorophyll fluorescence (SIF) has been widely used to track vegetation photosynthesis at different scales ranging from in-situ measurements to satellite products. Airborne platforms sample SIF data at a spatial scale intermediate between in-situ and satellite, matching that of ground measurement (e.g. flux tower footprints and other field sampling), enabling us to explore causes of SIF variation and validate satellite-based SIF products. However, harmonizing SIF across sensors and platforms (correcting for systematic errors to yield a consistent, comparable SIF product) is challenging because SIF can be retrieved in different absorption windows, with different instruments and methods complicating the comparison between different observational levels (i.e., ground, airborne, satellites) and between sites equipped with different instruments with varying optical properties (spectral resolution and sampling intervals, spatial resolution). Additionally, the spatial and temporal variability of atmospheric properties can influence the retrieval of the weak SIF signal. Because of these complications, direct comparisons of airborne and ground SIF across scales are rarely attempted. Here, in this study, we combined airborne SIF data with simultaneous ‘ground truth’ data collected by stationary and mobile platforms in a soybean field in Nebraska, USA. In this effort, we tested several SIF extraction methods, including Fraunhofer Line Discrimination (FLD), improved Fraunhofer Line Discrimination (iFLD), Spectral Fitting Method (SFM), SpecFit, and a Singular Vector Decomposition (SVD) method. The SpecFit method was sensitive to the 715–740 nm water bands and removing the water bands in the fitting process yielded better agreement between the airborne and ground SIF spectra. Accurate estimation of the ground level downwelling irradiance obtained by ground measurements over a calibration target improved agreement between airborne and ground SIF retrievals at the O 2 A band, and allowed us to derive a SIF dataset with improved agreement across platforms and sampling scales. This experimental approach provided a method for generating comparable SIF signals across instruments, methods and platforms, which is critical to understanding the SIF-GPP relationship at different scales and to cross-validate the diversity of platforms used for satellite products calibration and validation.

54 ENVIRONMENTAL SCIENCES↗

An Evaluation of Least-Squares Fitting Methods in XAFS Spectroscopy: Iron-Based SBA-15 Catalyst Formations

A detailed comparison has been made of determinations by {sup 57}Fe M{umlt o}ssbauer spectroscopy and four different XAFS spectroscopic methods of %Fe as hematite and ferrihydrite in 11 iron-based SBA-15 catalyst formulations. The four XAFS methods consisted of least-squares fitting of iron XANES, d(XANES)/dE, and EXAFS (k{sup 3}chi and k{sup 2}chi) spectra to the corresponding standard spectra of hematite and ferrihydrite. The comparison showed that, for this particular application, the EXAFS methods were superior to the XANES methods in reproducing the results of the benchmark M{umlt o}ssbauer method in large part because the EXAFS spectra of the two iron-oxide standards were much less correlated than the corresponding XANES spectra. Furthermore, the EXAFS and M{umlt o}ssbauer results could be made completely consistent by inclusion of a factor of 1.3 {+-} 0.05 for the ratio of the M{umlt o}ssbauer recoilless fraction of hematite relative to that of ferrihydrite at room temperature (293 K). This difference in recoilless fraction is attributed to the nanoparticle nature of the ferrihydrite compared to the bulk nature of the hematite. Also discussed are possible alternative non-least-squares XAFS methods for determining the iron speciation in this application as well as criteria for deciding whether or not least-squares XANES methods should be applied for the determination of element speciation in unknown materials.

59 BASIC BIOLOGICAL SCIENCES↗

On the effectiveness in implementing a waste-management-plan method in construction

The increasing awareness of waste management concerns from construction and demolition waste has led to the development of waste management as an important function of construction project management. The Hong Kong government started employing the implementation of a waste-management-plan (WMP) method for all construction projects in 2003. During the trial period, the government received different version of feedback from the industry. It also came out that detailed descriptions of waste management procedures in the WMP method largely affect the productivity of companies. This paper investigates the effectiveness of the existing implementation of the WMP method in the Hong Kong construction industry. A questionnaire survey and structured interviews were conducted. The result showed that 'Propose methods for on-site reuse of materials' and 'Propose methods for reducing waste' are the main benefits gained from the implementation of the WMP method. However, 'Low financial incentive' and 'Increase in overhead cost' are considered as the major difficulties in the implementation. From that, 'Use of prefabricated building components' is considered as the major effective measure to encourage the implementation of the WMP method.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Benchmarking Concentration and Extraction Methods for Wastewater-Based Surveillance of Eight Human Respiratory Viruses: Implications for Rapid Application to Novel Pathogens

To provide early warning and support a rapid response to a novel virus through wastewater surveillance, it would be ideal to understand in advance which concentration and extraction methods are likely to be effective for dPCR-based methods, depending on virus characteristics. In this study, we spiked raw wastewater samples with eight human respiratory viruses and processed them with four methods that concentrate and/or extract nucleic acids from both liquid and solid fractions (Promega, Nanotrap, and InnovaPrep) or only the solid fraction of wastewater (Solids). Our findings provide encouraging evidence that all four methods combined with dPCR could detect an emerging virus in wastewater, although they differed in sensitivity. The pattern of recovery efficiency for adenoviruses, coronaviruses, and influenza A viruses was consistent across methods, with Promega producing higher median recovery efficiencies, while distinct patterns were observed for coxsackieviruses. We also normalized the concentration data with two endogenous fecal indicators, PMMoV and Carjivirus (formerly crAssphage). We found that normalization could reduce method-associated differences if the indicator exhibited a recovery pattern similar to that of the target virus. These findings can guide the selection of concentration and extraction methods for wastewater monitoring based on the properties of target viruses, thus enhancing pandemic preparedness.

Biological and medical sciences↗

Assessment of Different Discrete Particle Methods Ability To Predict Gas-Particle Flow in a Small-Scale Fluidized Bed

Several discrete particle methods exist in the open literature to simulate fluidized bed systems, such as discrete element method (DEM), time driven hard sphere (TDHS), coarse-grained particle method (CGPM), coarse grained hard sphere (CGHS), and multi-phase particle-in-cell (MP-PIC). These different approaches usually solve the fluid phase in a Eulerian fixed frame of reference and the particle phase using the Lagrangian method. The first difference between these models lies in tracking either real particles or lumped parcels. The second difference is in the treatment of particle-particle interactions: by calculating collision forces (DEM and CGPM), using momentum conservation laws (TDHS and CGHS), or based on particle stress model (MP-PIC). These major model differences lead to a wide range of results accuracy and computation speed. However, these models have never been compared directly using the same experimental dataset. In this research, a small-scale fluidized bed is simulated with these methods using the same open-source code MFIX. The results indicate that modeling the particle-particle collision by TDHS increases the computation speed while maintaining good accuracy. Also, lumping few particles in a parcel increases the computation speed with little loss in accuracy. However, modeling particle-particle interactions with solids stress leads to a big loss in accuracy with a little increase in computation speed. The MP-PIC method predicts an unphysical particle-particle overlap, which results in incorrect voidage distribution and incorrect overall bed hydrodynamics. Based on this study, we recommend using the CGHS method for fluidized bed simulations due to its computational speed that rivals that of MPPIC while maintaining a much better accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward a QUBO-Based Density Matrix Electronic Structure Method

Density matrix electronic structure theory is used in many quantum chemistry methods to “alleviate” the computational cost that arises from directly using wave functions. Although density matrix based methods are computationally more efficient than wave function based methods, significant computational effort is involved. Because the Schrödinger equation needs to be solved as an eigenvalue problem, the time-to-solution scales cubically with the system size in mean-field type approaches such as Hartree–Fock and density functional theory and is solved as many times in order to reach charge or field self-consistency. We hereby propose and study a method to compute the density matrix by using a quadratic unconstrained binary optimization (QUBO) solver. This method could be useful to solve the problem with quantum computers and, more specifically, quantum annealers. Our proposed approach is based on a direct construction of the density matrix using a QUBO eigensolver. We explore the main parameters of the algorithm focusing on precision and efficiency. We show that, while direct construction of the density matrix using a QUBO formulation is possible, the efficiency and precision have room for improvement. Moreover, calculations performed with quantum annealing on D-Wave’s new Advantage quantum computer are compared with results obtained with classical simulated annealing, further highlighting some problems of the proposed method. Finally, we also suggest alternative methods that could lead to a more efficient QUBO-based density matrix construction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Effective Fragment Molecular Orbital Method: Achieving High Scalability and Accuracy for Large Systems

The effective fragment molecular orbital (EFMO) method has been developed to predict the total energy of a very large molecular system accurately (with respect to the underlying quantum mechanical method) and efficiently by taking advantage of the locality of strong chemical interactions and employing a two-level hierarchical parallelism. The accuracy of the EFMO method is partly attributed to the accurate and robust intermolecular interaction prediction between distant fragments, in particular, the many-body polarization and dispersion effects, which require the generation of static and dynamic polarizability tensors by solving the coupled perturbed Hartree–Fock (CPHF) and time-dependent HF (TDHF) equations, respectively. Solving the CPHF and TDHF equations is the main EFMO computational bottleneck due to the inefficient (serial) and I/O-intensive implementation of the CPHF and TDHF solvers. In this work, the efficiency and scalability of the EFMO method are significantly improved with a new CPU memory-based implementation for solving the CPHF and TDHF equations that are parallelized by either message passing interface (MPI) or hybrid MPI/OpenMP. Here, the accuracy of the EFMO method is demonstrated for both covalently bonded systems and noncovalently bound molecular clusters by systematically examining the effects of basis sets and a key distance-related cutoff parameter, R cut . R cut determines whether a fragment pair (dimer) is treated by the chosen ab initio method or calculated using the effective fragment potential (EFP) method (separated dimers). Decreasing the value of Rcut increases the number of separated (EFP) dimers, thereby decreasing the computational effort. It is demonstrated that excellent accuracy (<1 kcal/mol error per fragment) can be achieved when using a sufficiently large basis set with diffuse functions coupled with a small R cut value. With the new parallel implementation, the total EFMO wall time is substantially reduced, especially with a high number of MPI ranks. Given a sufficient workload, nearly ideal strong scaling is achieved for the CPHF and TDHF parts of the calculation. For the first time, EFMO calculations with the inclusion of long-range polarization and dispersion interactions on a hydrated mesoporous silica nanoparticle with explicit water solvent molecules (more than 15k atoms) are achieved on a massively parallel supercomputer using nearly 1000 physical nodes. In addition, EFMO calculations on the carbinolamine formation step of an amine-catalyzed aldol reaction at the nanoscale with explicit solvent effects are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Effect of Synthetic Method and Annealing Temperature on Metal Site Preference in Al 1-x Ga x FeO 3

Magnetoelectric materials couple both magnetic and electronic properties, making them attractive for use in multifunctional devices. The magnetoelectric AFeO 3 compounds (Pna2 1 ; A = Al, Ga) have received attention as the properties of the system depend on composition as well as the synthetic method used. Al 1–x Ga x FeO 3 (0 ≤ x ≤ 1) was synthesized by the sol–gel and coprecipitation methods and studied by X-ray absorption near-edge spectroscopy (XANES). Al L 2,3⁻ , Ga K-, and Fe K-edge XANES spectra were collected to examine how the average metal coordination number (CN) changes with the synthetic method. Al and Fe were found to prefer octahedral sites, while Ga prefers the tetrahedral site. It was found that composition played a larger role in determining site occupancies than synthetic method. Samples made by the sol–gel or ceramic methods (reported previously; Walker, J. D. S.; Grosvenor, A. P. J. Solid State Chem. 2013, 197, 147–153) showed smaller spectral changes than samples made via the coprecipitation method. This is attributed to greater ion mobility in samples synthesized via coprecipitation as the reactants do not have a long-range polymeric or oxide network during synthesis like samples synthesized via the sol–gel or ceramic method. Increasing annealing temperature increases the average coordination number of Al, and to a lesser extent Ga, while the average coordination number of Fe decreases. This study indicates that greater disorder is observed when the Al 1–x Ga x FeO 3 compounds have high Al content, and when annealed at higher temperatures.

Walker, James D.S.↗

Effectiveness of CID, HCD, and ETD with FT MS/MS for Degradomic-Peptidomic Analysis: Comparison of Peptide Identification Methods

We report on use of an Orbitrap Velos mass spectrometer for comparison of fragmentation methods namely CID-, HCD-, and ETD for FT MS/MS analysis of human blood plasma peptidomic peptides. The peptidomic peptides were able to be identified from CID, HCD, and ETD spectra on specific confidence levels (e.g., 1% false discovery rate) with use of conventional SEQUEST database search software, and the number of identified peptides was increased by ~50% using accurate fragments (e.g., with mass tolerance of 0.05Da) in comparison with traditional moderate accuracy fragments (e.g., with 1 Da mass tolerance) for database search. However, the peptide datasets identified with such decoy search strategy were found to be varied by ~25% in the dataset size and ~20% in the dataset content with type of decoy database and precursor mass tolerances used for database search. CID was evaluated as the largest contributor to the identified peptide datasets, and HCD, and ETD provided ~20% and ~22% respectively additional peptides with accurate fragments for peptide identification, in contrast to ~25% and ~13% respectively with use of moderate accuracy fragments. When long (typically ≥7 amino acids) sequences were used for identification of peptides from the previously published UStags and de novo sequencing methods, HCD was evaluated as the largest contributor, and CID and ETD provided ~26% and ~8% respectively additional peptides from the UStags method and ~26% and ~6% respectively additional peptides from the de novo sequencing method. The peptide datasets identified with the UStags method were little influenced by the decoy database and mass tolerance and 98-99% peptide overlaps could be achieved between these datasets. CID, HCD, and ETD contributed their identifications of various charge state peptides in the m/z range highly overlapped and complementary implementation of CID, HCD, and ETD should be applied to maximize the number of peptides identified. Finally, the investigation presented in this work suggests that selection of fragmentation methods benefits significantly from a careful match with data analysis method applied for identification of peptides and the analysis throughput desired for various purposes of peptidomic-degradomic analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Physics-Informed Neural Network Method for Forward and Backward Advection-Dispersion Equations

Advection-dispersion equations (ADEs) are commonly used to describe transport phenomena in porous media. Even though mature discretization-based numerical methods for ADEs exist, some challenges still remain, especially when it comes to solving advection-dominated forward ADEs and diffusion-dominated backward ADEs. The latter problem usually arises in the source identification context and leads to numerically unstable grid-based solutions that require a form of regularization or should be treated as an inverse problem that is computationally more expensive because it requires solving the forward problem multiple times. In this study, we propose a discretization-free approach based on the physics-informed neural network (PINN) method for solving coupled ADE and Darcy flow equations with space-dependent hydraulic conductivity. In this approach, the hydraulic conductivity, hydraulic head, and concentration fields are approximated with deep neural networks (DNNs). We assume that the conductivity field is given by its values on a grid, and we use these values to train the conductivity DNN. The head and concentration DNNs are trained by minimizing the residuals of the flow equation and ADE and using the initial and boundary conditions as additional constraints. The PINN method is applied to one- and two-dimensional forward ADE problems, where its performance for various P\'{e}clet numbers ($Pe$) is compared with the analytical and numerical solutions. We find that the PINN method is accurate with errors of less than 1\% and outperforms some conventional discretization-based methods for $Pe$ larger that 100. Next, we demonstrate that the PINN method remains accurate for the backward ADEs, with the relative errors in most cases staying under 5\% compared to the reference concentration field. Finally, we show that when available, the concentration measurements can be easily incorporated in the PINN method and significantly improve (by more than 50\% in the considered cases) the accuracy of the PINN solution of the backward ADE.

He, Qizhi↗

Spanning the Gap From Bulk to Bin: A Novel Spectral Microphysics Method

Microphysics methods for climate models and numerical weather prediction typically track one, two, or three moments of a droplet size distribution for various categories of liquid, ice, and aerosol. Such methods rely on conversion parameters between these categories, which introduces uncertainty into predictions. While higher-fidelity options such as bin and Lagrangian schemes exist, they require too many degrees of freedom for climate modeling applications and introduce numerical challenges. Here we introduce a flexible spectral microphysics method based on collocation of basis functions. This method generalizes to a linear bulk scheme when using few basis functions and to a smoothed bin scheme with more degrees of freedom. Tested in an idealized box setting, the method improves spectral accuracy for droplet collision-coalescence and may eliminate the need for precipitation autoconversion rates required by bulk methods; furthermore, it generalizes well to multimodal distributions with less complexity than a bin method. The potential to extend this collocation representation to multiple hydrometeor classes suggests a path forward to unify liquid, ice, and aerosol microphysics in a single, flexible, computational framework for climate modeling.

54 ENVIRONMENTAL SCIENCES↗