Search NASA⌕ Search

SEARCH · Search NASA

Results for “optimized infrastructure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

Challenge Online Time Series Clustering For Demand Response A Theory to Break the ‘Curse of Dimensionality'

The advent of smart meters and advanced communication infrastructures catalyzes numerous smart grid applications such as dynamic demand response, and paves the way to solve challenging research problems in sustainable energy consumption. The space of solution possibilities are restricted primarily by the huge amount of generated data requiring considerable computational resources and efficient algorithms. To overcome this Big Data challenge, data clustering techniques have been proposed. Current approaches however do not scale in the face of the “increasing dimensionality” problem where a cluster point is represented by the entire customer consumption time series. To overcome this aspect we first rethink the way cluster points are created and designed, and then design an efficient online clustering technique for demand response (DR) in order to analyze high volume, high dimensional energy consumption time series data at scale, and on the fly. Our online algorithm is randomized in nature, and provides optimal performance guarantees in a computationally efficient manner. Unlike prior work we (i) study the consumption properties of the whole population simultaneously rather than developing individual models for each customer separately, claiming it to be a ‘killer’ approach that breaks the “curse of dimensionality” in online time series clustering, and (ii) provide tight performance guarantees in theory to validate our approach. Our insights are driven by the field of sociology, where collective behavior often emerges as the result of individual patterns and lifestyles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Security and Privacy in Cyber-Physical Systems

As you have seen from the previous chapters, cyber-physical systems (CPS) are broadly used across technology and industrial domains. While these systems enable process optimization and efficiency and allow previously impossible functionality, security and privacy are key concerns for their design, development, and operation. CPS have been key components utilized in some of the highest publicized security breaches over the last decade. In this chapter, we will look over the CPS described in the previous chapters from a security perspective. In this chapter, we explain classical information and physical security fundamentals in the context of CPS and contextualize them across application domains. We give examples where the interplay of functionality and diverse communication can introduce unexpected vulnerabilities and produce larger impacts. We will discuss how CPS security and privacy is inherently different from that of pure cyber or physical systems and what may be done to secure these systems, considering their emergent cyber-physical properties. Finally, we will discuss security and privacy implications of merging infrastructural and personal CPS. Our hope is to impart the knowledge of what CPS security and privacy are, why they are important, and explain existing processes and challenges.

Cyber-physical systems↗

Understanding the Hierarchy of Dense Subgraphs in Stationary and Temporally Varying Setting

Graphs are widely used to model relationships in a wide variety of domains such as sociology, bioinformatics, infrastructure, the WWW, to name a few. One of the key observations is that while real-world graphs are often globally sparse, they are locally dense. In other words, the average degree is often quite small (say at most 10 in a million vertex graph), but vertex neighborhoods are often dense. Finding dense subgraphs is a critical aspect of graph mining It has been used for finding communities and spam link farms in web graphs, graph visualization, real-time story identification, DNA motif detection in biological networks, finding correlated genes, epilepsy prediction, finding price value motifs in financial data, graph compression, distance query indexing, and increasing the throughput of social networking site servers. However, most standard formulations of this problem (like clique, quasi-clique, k-densest subgraph) are NP-hard. Furthermore, current dense subgraph finding algorithms usually optimize some objective, and only find a few such subgraphs without providing any structural relations, whereas the goal is rarely to find the "true optimum," but to identify many (if not all) dense substructures, understand their distribution in the graph, and ideally determine relationships among them. In this project, we first aim to devise algorithms and provide 3 implementations with nice visualizations to find the hierarchy between dense subgraphs, and then understand the structure of the hierarchy to gain more insight on the hidden patterns in real-world networks. Another important aspects in graph analysis is the temporal nature of networks. Networks evolve over time and in many applications data arrives at a high velocity, and thus it is important to design algorithms that can process data efficiently. We report three main results towards identifying dense structures in large evolving graphs. First, we will show how the hierarchical connectedness structure can be maintained efficiently, where connectedness is defined by increasing levels of connectivity strength. Next, we present dense structure can be identified in bipartite graphs without building projection graphs. And finally, we present a new method for peeling algorithms This new approach avoids sequential nature of peeling algorithms and is amenable to parallelization, which is crucial for processing high velocity data.

97 MATHEMATICS AND COMPUTING↗

Performance Evaluation for a Modular, Scalable Passive Cooling System in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected passive, modular localized cooling solution provided by vendor 4. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a passive, modular, scalable liquid cooling system in this study. The scope is to quantify energy performance of the modular cooling unit corresponding to various server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lunar Outpost Life Support Architecture Study Based on a High Mobility Exploration Scenario

As scenarios for lunar surface exploration and habitation continue to evolve within NASA s Constellation program, so must studies of optimal life support system architectures and technologies. This paper presents results of a life support architecture study based on a 2009 NASA scenario known as Scenario 12. Scenario 12 represents a consolidation of ideas from earlier NASA scenarios and includes an outpost near the Lunar South Pole comprised of three larger fixed surface elements and four attached pressurized rovers. The scenario places a high emphasis on surface mobility, with planning assuming that all four crewmembers spend roughly 50% of the time away from the outpost on 3-14 day excursions in two of the pressurized rovers. Some of the larger elements can also be mobilized for longer duration excursions. This emphasis on mobility poses a significant challenge for a regenerative life support system in terms of cost-effective waste collection and resource recovery across multiple elements, including rovers with very constrained infrastructure resources. The current study considers pressurized rovers as part of a distributed outpost life support architecture in both stand-alone and integrated configurations. A range of architectures are examined reflecting different levels of closure and distributed functionality. Different lander propellant scavenging options are also considered involving either initial conversion of residual oxygen and hydrogen propellants to water or initial direct oxygen scavenging. Monte Carlo simulations are used to assess the sensitivity of results to volatile high-impact mission variables, including the quantity of residual lander propellants available for scavenging, the fraction of crew time away from the outpost on excursions, total extravehicular activity hours, and habitat leakage. Architectures are evaluated by estimating surpluses or deficits of water and oxygen per 180-day mission and differences in fixed and 10-year-total equivalent system mass (ESM) relative to a reference case. Results are presented based on current assumptions for Scenario 12 and based on Monte Carlo simulations with assumed probability distributions for the high-impact mission variables. The calculated probability of no water or oxygen resupply from Monte Carlo simulations provides a quantitative measure of system robustness that can be used for cost/benefit analyses to identify leading architecture candidates. Areas of technology improvement that are likely to have a significant impact are also suggested.

Lange, Kevin E.↗

Analyzing SCM Grid Benefits from Electric Transportation [Slides]

Increasing adoption of EVs and expanding unmanaged charging loads could increase the cost of transportation energy due to increasing load variability and shrinking infrastructure capacity. The actual cost of transportation energy, such as charging an EV, depends on several factors including energy costs, charging infrastructure costs, and applicable grid upgrades. Based on studies from past DOE projects; RECHARGE, DirectXFC, FUSE and 21st Century Truck Partnership (21CTP) the EV-CENTS project will develop a transportation energy cost metric to better quantify these factors and provide a framework for assessing the value potential of new technology solutions, such as smart charge management (SCM), which could reduce these costs for all stakeholders. The initial assessment will focus on the cost of charging, which will vary across vehicle classes such as light-duty vehicles (LDV) or medium and heavy-duty vehicles (MHDV), as well as across different vocations resulting in many different use cases for this metric. Cost of charging results will be developed for each use case in both uncontrolled and controlled scenarios to understand the value potential of different SCM objective functions and their ability to optimize the cost of energy and delay or eliminate the need for electrical upgrades.

33 ADVANCED PROPULSION SYSTEMS↗

Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Monitoring solid metal structures with a nervous system embedded with ultrasonic 3D printing

Active and regular monitoring of structural components is a critical safety precaution, particularly as it concerns infrastructure, aerospace, industry, and many other applications. Solutions for effective structural health monitoring need to be able to probe surface and bulk properties using durable and low-power engineering. Towards these ends it is possible to build smarter, highly networked, and secure materials in order to enable remote real-time material sensing with a lesser-known form of 3D printing, ultrasonic consolidation (UC). This approach harnesses sound waves to weld metal layers in a low temperature process that does not damage sensors and electronics as they are embedded into a solid metal structure. This makes UC perfectly suited for designing solid metal parts with active embedded sensing components. However, the process parameters, material influences and mechanical factors that result in high-quality UC metal components are difficult to control or are loosely understood. The use of trial-and-error optimization during fabrication represents the chief hurdle between its current state of use and its potential to transform rapid prototyping and manufacturing of high-impact technologies (e.g., metal smart structures, wearable sensors, lab-on-a-chip, etc.). In this paper we will describe how embedded sensors may be used for in situ process monitoring and optimization. We will also discuss efforts towards standardizing UC welding for similar and dissimilar metal bonding and for embedding active sensors that can be used to create smart structures that will enable long-term structural health monitoring and other high impact applications.

Suter, Jonathan D.↗

Issue Paper: Electricity System Adequacy - Challenges Facing the Nuclear Power Industry

One in a series of Issue Papers addressing Electricity System Adequacy, this report focuses on Challenges Facing the Nuclear Power Industry. Early proclamations of a nuclear renaissance yield to predictions of the industry's decline, while proposed carbon regulations offer potential optimism to use nuclear as a clean energy source. Yet, nuclear plants are currently 'at-risk' of early retirement (for economic reasons) due to electricity market design issues and competition with low priced natural gas. Concerns are identified as baseload generation shifts from coal and nuclear to increasing natural gas and renewables which may impact on the reliability of the power system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants' input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 1. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable overhead cooling system. The system was tested in a hot/cold aisle environment without separation, or containment or the hot or cold aisles. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 2. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable pair of chilled water cooling modules that were tested in a hot/cold aisle environment with hot aisle containment. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hanford Direct Feed Low Activity Waste Program Throughput Optimization Through Modeling - 18587

The Direct Feed Low Activity Waste (DFLAW) program at Hanford allows for the early treatment of tank wastes years earlier than previously planned. Operational Research (OR) modeling is being used to provide invaluable insight into how complex and integrated processes will operate. The DFLAW OR models are used to help optimize the design and operation of the integrated system. The DFLAW OR models include the processes and real-life complexities involved in the day-to-day operation of the systems and equipment, and can predict key performance characteristics including throughput, mission timescale, equipment and labor utilization, lag storage and capacity requirements. The DFLAW OR models also have the in-built capability to simulate random events such as equipment failures. Adding random variability to models introduces a real-life element to model results. For example, OR modeling breakdown analysis of equipment failure and restoration times may inform specific improvements to a design and plant operation, including areas where the provision of spare (duty/standby) equipment would prove beneficial; the optimum number and capacity of lag storage tanks (for waste intermediate storage, reagents, etc.); operational issues, including scheduling constraints, labor resource constraints, effect of shift schedules (e.g. days only, extended shifts, 24/7),, maintenance strategies, including planned maintenance, equipment upgrades, on-hand spare part stockholding, etc. At Hanford, standalone OR models to date, have been used to help identify key operational issues and improve the design and operation of individual systems within the Tank Farms, Low Activity Waste Pretreatment System (LAWPS), Low Activity Waste (LAW) Vitrification and Effluent Management Facility (EMF) and Integrated Disposal Facility (IDF), logistics and infrastructure, 222-S laboratory [References 1 and 2] including: - Identification of critical spares including transfer pumps; - Underpin size and number of lag storage tanks to maintain continuous LAW feed to the LAW melters; - Underpin sample turnaround times at the 222-S Laboratory (e.g. feed prequalification and evaporator campaign samples) and determine how targets can be achieved without impacting waste feed delivery to LAWPS and the LAW Vitrification Facility; - Determine operational strategy required at IDF including shift schedules and sizes and the number of ILAW transporters that can support DFLAW throughput; - Identification of lag storage management strategies for glass formers, reagents, other consumables due to delivery distance and delays due to bad weather; and - Truck delivery badging needs to support 24/7 operation and management of shift in/out times required to reduce congestion. An Integrated DFLAW OR model has been developed and combines the standalone OR models such that integrated throughput and availability can be assessed from a program perspective. The Integrated OR model will provide a more detailed understanding of the interactions between Tank Farms, LAWPS, LAW VIT and IDF such that key bottleneck areas can be identified and ensure improvements are focused. Examples of future improvements that may be considered include identification of critical spare parts, required on-site maintenance capabilities, shift scheduling, and craft and labor availability. The methods, results and insights derived by DFLAW OR modeling efforts are expected to provide useful applications to other projects that involve combinations of mechanical handling, chemical processing, waste treatment/packaging or environmental remediation operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reinventing CEMENT: Carbonation-Enabled Mineralization to Engender Novel Technology

Cement is the most important building material used in civil infrastructure but it is extremely energy intensive to produce. We developed novel ways to make cements at low temperatures by mimicking the chemistry of the calcium silicate mineral pseudowollastonite. Pseudowollastonite is interesting because when it is exposed to hot (90-150oC), alkaline conditions with CO2 and water it reacts to form mineral phases that are much stronger than commercial cements. The resulting phases are also much more resistant to acid attack and have lower permeability, which will make them last longer. Many of the mineral phases in our cements are similar to those that exist in ancient Roman cements that have lasted thousands of years. Our objective was to understand how waste materials from industrial processes (such as power production, municipal solid waste treatment, or power plants) can be used to replicate the conditions that give pseudowollastonite cement its remarkable properties. We worked to optimize our formulations and incorporate the cements into concrete blends that the industry can test and consider using in different applications. Our cements could be used in pre-cast cement structural elements, which makes up nearly 20% of the total cement market and is growing rapidly. This work supports ARPA-E program objectives to significantly improve the industrial efficiency of materials production.

36 MATERIALS SCIENCE↗

Acrylonitrile-butadiene-lignin thermoplastic rubber adhesive for enhanced metal-to-metal joining

With the growing requirement for lightweight structural materials in automotive, aerospace, and infrastructure applications, multi-material joints made with adhesive have attracted intense research interest. Commercial thermoset adhesives are one-time cures, and difficult to disassemble the bonded components for repair and recycling. Our prior work with a thermoplastic acrylonitrile-butadiene-lignin rubber (ABL) addresses this sustainability/recycling challenge, but the adhesive exhibits deficient joining strength compared to standard thermosets. Here, we modify the ABL matrix by loading particulate fillers to enhance its modulus and toughness. Further, the goal is to manufacture a cure-free thermoplastic adhesive system with a simple dispensing protocol and characteristic ductility combined with a high yield stress for improved shear strength of a bonded joint. Fumed silica (FS) and epoxidized glass spheres (EGS) were used as fillers in the ABL to promote the dispersion of lignin particles that tailored the functionalities and free energy components of the adhesive surface. With optimal loading of FS (5 wt%) and EGS (30 wt%) in the ABL adhesive matrix, the lap-shear strength of the bonded aluminum joint was elevated by 128%, compared to the neat ABL, reaching 21 MPa, which is 90% of the performance of a commercial epoxy-based adhesive.

36 MATERIALS SCIENCE↗

IEEE PES GM Poster - Cyber-Informed Engineering Approach to Mitigating BESS Supply Chain Concerns

Battery energy storage systems (BESS) are increasingly important to meet the needs of grid resilience and reliability. BESS provide critical grid services, maintaining stability of the grid with increased variable conditions. However, there are significant geopolitical and security concerns regarding their operation in critical infrastructure, due to lack of a domestic supply chain and prevalence of foreign entity of concern (FEOC) components in BESS and associated inverter-based resources. The supply chain challenge is dually exacerbated by a lack of alternative suppliers who can meet the economic targets for energy delivery and a potentially adversarial supply chain. Solutions are needed to secure components, addressing mixed layers of risk and engineering controls. This paper presents a specific application of Cyber-Informed Engineering (CIE) principles for BESS and recommends an alternative strategy to blocking the supply chain, ensuring that grid modernization targets can be met despite lack of a validated or secure supply chain. This study focuses on the United State (U.S.) use case, but the process can be applied globally to address supply chain security challenges. CIE practices represent the next step in functional assurance and risk mitigation, ensuring optimal resource allocation and enhancing security measures to safeguard the future of energy in the U.S. and beyond.

25 - ENERGY STORAGE↗

Optimization of tomographic reconstruction workflows on geographically distributed resources

New technological advancements in synchrotron light sources enable data acquisitions at unprecedented levels. This emergent trend affects not only the size of the generated data but also the need for larger computational resources. Although beamline scientists and users have access to local computational resources, these are typically limited and can result in extended execution times. Applications that are based on iterative processing as in tomographic reconstruction methods require high-performance compute clusters for timely analysis of data. Here, time-sensitive analysis and processing of Advanced Photon Source data on geographically distributed resources are focused on. Two main challenges are considered: (i) modeling of the performance of tomographic reconstruction workflows and (ii) transparent execution of these workflows on distributed resources. For the former, three main stages are considered: (i) data transfer between storage and computational resources, (i) wait/queue time of reconstruction jobs at compute resources, and (iii) computation of reconstruction tasks. These performance models allow evaluation and estimation of the execution time of any given iterative tomographic reconstruction workflow that runs on geographically distributed resources. For the latter challenge, a workflow management system is built, which can automate the execution of workflows and minimize the user interaction with the underlying infrastructure. The system utilizes Globus to perform secure and efficient data transfer operations. The proposed models and the workflow management system are evaluated by using three high-performance computing and two storage resources, all of which are geographically distributed. Workflows were created with different computational requirements using two compute-intensive tomographic reconstruction algorithms. Experimental evaluation shows that the proposed models and system can be used for selecting the optimum resources, which in turn can provide up to 3.13× speedup (on experimented resources). Furthermore, the error rates of the models range between 2.1 and 23.3% (considering workflow execution times), where the accuracy of the model estimations increases with higher computational demands in reconstruction tasks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Oak ridge national laboratory automated clean chemistry for bulk analysis of environmental swipe samples

To shorten the lengthy and costly manual chemical purification procedures, sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment. This addresses a serious need in the nuclear safeguards community to debottleneck the separation of U and Pu in environmental samples—currently performed by overburdened chemists—with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc., the prepFAST-MC2 was designed based on current COTS equipment that was modified for U/Pu separations utilizing Eichrom™ TEVA and UTEVA resins. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined column calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. The reproducibility of the automated system was tested with samples containing 30 ng U and 15 pg Pu, which were separated in a series with alternating reagent blanks. These experiments showed very good washout of both the resin and the sample from the columns as evidenced by low blank values. Analysis of the major and minor isotope ratios for U and Pu provided values well within data quality limits for the International Atomic Energy Agency. Additionally, system process blanks spiked with 233U and 244Pu tracers were separated using the automated system after it was moved outside of a clean room and yielded levels equivalent to clean room blanks, confirming that the system can produce high quality results without the need for expensive clean room infrastructure. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced costs by limiting personnel hours dedicated to the chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗