Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Photovoltaic module and module arrays

A photovoltaic (PV) module including a PV device and a frame, The PV device has a PV laminate defining a perimeter and a major plane. The frame is assembled to and encases the laminate perimeter, and includes leading, trailing, and side frame members, and an arm that forms a support face opposite the laminate. The support face is adapted for placement against a horizontal installation surface, to support and orient the laminate in a non-parallel or tilted arrangement. Upon final assembly, the laminate and the frame combine to define a unitary structure. The frame can orient the laminate at an angle in the range of 3.degree.-7.degree. from horizontal, and can be entirely formed of a polymeric material. Optionally, the arm incorporates integral feature(s) that facilitate interconnection with corresponding features of a second, identically formed PV module.

14 SOLAR ENERGY↗

Cooled grating array spectrometer for 0.6-5 microns

A grating spectrometer, designed to illuminate an array of 122 InSb photodiodes with minimum aberrations and maximum speed, has been constructed. The instrument will be used on the 5 meter Hale telescope at Palomar Observatory, and is easily adaptable to telescopes of various focal ratios. A resolving power of 100-1000 can be obtained at wavelengths between 0.6 microns and 5 microns with remotely interchangeable gratings. The spectrometer is sufficiently compact to fit on the 8-inch work surface of a commercially available dewar, and uses simple on-axis spherical and paraboloidal optical elements. The camera mirror produces an f/2.5 beam which, with the 0.2 mm detectors, allows a 3-in. focal-plane aperture on the 5 meter telescope. All rays fall within a 100 microns blur circle at all points along the array. Distortions have been corrected with a tilted field flattening lens in front of the detector.

Nordholt, J. E.↗

Morphological changes in the NGC 6251 jet

The giant radio galaxy NGC 6251 is a particularly good object for observational tests of relativistic jet models. Due to its high declination and approximately 0.5 Jy radio nucleus, high-quality Very Long Baseline Interferometry (VLBI) images of the central regions of the source can be made with northern hemisphere arrays. In addition, the large-scale radio morphology strongly suggests that the radio axis lies close to the plane of the sky, so Doppler boosting should be less extreme than in the core-dominated superluminal sources. Earlier 18 cm VLBI observations of NGC 6251 revealed an unexpectedly large jet/counterjet brightness ratio and small transverse motion of a feature in the parsec-scale jet. These early results are difficult to reconcile with the simplest symmetric relativistic jet models. In this paper we present a third-epoch 18 cm VLBI image of the parsec-scale radio jet in NGC 6251, and compare jet morphology over a 5 year time span. The jet shows a minor brightness peak at nearly the same distance from the core as the '25 mas knot' seen in the first- and second-epoch VLBI images. This feature is much less pronounced in the third epoch, and a relatively bright, new knot has appeared approximately 12 mas from the core. If this new component had a constant brightness during the 5 years separating the first and third observing epochs, then it must have moved away from the core with an apparent speed of at least 1.2c (compared with an upper limit of 0.23c for motion of the 25 mas knot). However, we cannot yet rule out a local brightening of the inner jet in favor of a new moving component. We determine a lower limit for the jet/couterjet brightness ratio of 100:1 within 6 mas of the core. We also present a new Very Large Array (VLA) image of the kpc-scale jet with 3 sec resolution, made from data obtained during the VLBI observations. The rate of decrease in jet surface brightness from parsec to kiloparsec scales is similar to jets in known superluminal radio sources.

Jones, Dayton L.↗

ICESat Spacecraft Pointing Support Study Grant

The Geodetic Laser Altimeter System (GLAS) mission is designed to measure changes in the elevations of the polar ice sheets. The ICESat satellite will carry the GLAS altimeter, and will have a nominal orbit altitude of 600 km and orbit inclination of 94deg. The groundtrack repeat period is 182 days and will be maintained to less than 1 km at the equator via routine orbit adjustments. Science requirements for the GLAS mission demand that the laser altimeter be pointed to within 50 meters of a predetermined reference groundtrack. As the actual ICESat groundtrack drifts away from the reference groundtrack, the attitude must be controlled such that the altimeter boresight is pointed, crosstrack, at the reference groundtrack. This orientation may be described by a rotation, theta, about the instantaneous geodetic local horizontal direction vector, which lies in the orbit plane and is oriented in the direction of motion of the satellite. The attitude is further complicated by requirements related to thermal and power considerations for various instruments, spacecraft components, and solar array orientation. In order to keep battery temperatures within the specified operating range, and maintain near normal pointing of the solar array with respect to the sunline direction vector as the orbit precesses relative to the sun, the satellite will be oriented in one of four fixed yaw modes. Each of these yaw modes depends upon the angle between the orbit plane and the sunline direction vector; this angle is designated Beta'. Table 1 shows the satellite yaw angle, Psi, for a given Beta' range. The angle Psi represents a rotation about the satellite z-axis, which points in the geodetic nadir direction; for Psi = 0deg the satellite x-axis points in the direction of motion.

Source record↗

The influence of diffusion temperature on the structural, optical and magnetic properties of manganese-doped zinc oxysulfide thin films

We investigated the structural, optical and magnetic properties of Mn-doped zinc oxysulfide films. Zn(O,S) films were deposited by a spray pyrolysis method on glass substrate. A thin Mn layer evaporated on these films served as the source for the diffusion doping. The XRD pattern of undoped films revealed the presence of two wurtzite phases corresponding to ZnS and ZnO with a strong preferred orientation along the ZnS (0 0 2) hexagonal plane direction. SEM showed a similar surface morphology for the undoped and Mn-doped films, displaying regular arrays of hexagonal micro-rods perpendicular to the substrate. The optical transmission measurements showed that both undoped and Mn diffusion-doped films had a low average transmittance less than about 10%. The gap energy is decreased from 3.42 to 3.33 eV upon annealing at 400 deg. C. Photoluminescence studies at 300 K show that the incorporation of manganese leads to a decrease of deep level band intensity compared to undoped sample. Clear ferromagnetic loops were observed for the Mn-doped Zn(O,S) films, which might be due to the presence of point defects. - Graphical abstract: M-H variation of Mn diffusion-doped Zn(O,S) thin films measured at 300 K. Highlights: > Zinc oxysulfide thin films fabricated by spray pyrolysis and doped with Mn. > Regular arrays of hexagonal micro-rods perpendicular to the substrate. > Optical transmission measurements showed that both undoped and Mn diffusion-doped films had a low average transmittance less than about 10%. > Magnetic measurements show that Mn-doped zinc oxysulfide thin films exhibit a ferromagnetism behavior at room temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multipolar second harmonic generation in a symmetric nonlinear metamaterial

Optical nonlinearities are intimately related to the spatial symmetry of the nonlinear media. For example, the second order susceptibility vanishes for centrosymmetric materials under the dipole approximation. The latter concept has been naturally extended to the metamaterials’ realm, sometimes leading to the (erroneous) hypothesis that second harmonic (SH) generation is negligible in highly symmetric meta-atoms. In this work we aim to show that such symmetric meta-atoms can radiate SH light efficiently. In particular, we investigate in-plane centrosymmetric meta-atom designs where the approximation for meta-atoms breaks down. In a periodic array this building block allows us to control the directionality of the SH radiation. We conclude by showing that the use of symmetry considerations alone allows for the manipulation of the nonlinear multipolar response of a meta-atom, resulting in e.g. dipolar, quadrupolar, or multipolar emission on demand. This is because the size of the meta-atom is comparable with the free-space wavelength, thus invalidating the dipolar approximation for meta-atoms.

36 MATERIALS SCIENCE↗

Dual curved photonic crystal ring resonator based channel drop filter using two-dimensional photonic crystal structure

In this paper channel drop filter (CDF) is designed using dual curved photonic crystal ring resonator (PCRR). The photonic band gap (PBG) is calculated by plane wave expansion (PWE) method and the photonic crystal (PhC) based on two dimensional (2D) square lattice periodic arrays of silicon (Si) rods in air structure have been investigated using finite difference time domain (FDTD) method. The number of rods in Z and X directions is 21 and 20 respectively with lattice constant 0.540 nm and rod radius r = 0.1 µm. The channel drop filter has been optimized for telecommunication wavelengths λ = 1.591 µm with refractive indices 3.533. In the designed structure further analysis is also done by changing whole rods refractive index and it has been observed that this filter may be used for filtering several other channels also. The designed structure is useful for CWDM systems. This device may serve as a key component in photonic integrated circuits. The device is ultra compact with the overall size around 123 µm{sup 2}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IMAGING DISK DISTORTION OF BE BINARY SYSTEM {delta} SCORPII NEAR PERIASTRON

The highly eccentric Be binary system {delta} Sco reached periastron during early 2011 July, when the distance between the primary and secondary was a few times the size of the primary disk in the H band. This opened a window of opportunity to study how the gaseous disks around Be stars respond to gravitational disturbance. We first refine the binary parameters with the best orbital phase coverage data from the Navy Precision Optical Interferometer. Then we present the first imaging results of the disk after the periastron, based on seven nights of five telescope observations with the MIRC combiner at the CHARA array. We found that the disk was inclined 27.{sup 0}6 {+-} 6.{sup 0}0 from the plane of the sky, had a half-light radius of 0.49 mas (2.2 stellar radii), and consistently contributed 71.4% {+-} 2.7% of the total flux in the H band from night to night, suggesting no ongoing transfer of material into the disk during the periastron. The new estimation of the periastron passage is UT 2011 July 3 07:00 {+-} 4:30. Re-analysis of archival VLTI-AMBER interferometry data allowed us to determine the rotation direction of the primary disk, constraining it to be inclined either {approx}119 Degree-Sign or {approx}171 Degree-Sign relative to the orbital plane of the binary system. We also detect inner disk asymmetries that could be explained by spot-like emission with a few percent of the disk total flux moving in Keplerian orbits, although we lack sufficient angular resolution to be sure of this interpretation and cannot yet rule out spiral density waves or other more complicated geometries.

79 ASTRONOMY AND ASTROPHYSICS↗

Fano resonances in magnetic metamaterials

We study the scattering of magnetoinductive plane waves by internal (external) capacitive (inductive) defects coupled to a one-dimensional split-ring resonator array. We examine a number of simple defect configurations where Fano resonances occur and study the behavior of the transmission coefficient as a function of the controllable external parameters. We find that for embedded capacitive defects, the addition of a small amount of coupling to second neighbors is necessary for the occurrence of Fano resonance. For external inductive defects, Fano resonances are commonplace, and they can be tuned by changing the relative orientation or distance between the defect and the SSR array.

36 MATERIALS SCIENCE↗

Experimental investigation of the response of an a-Si EPID to an unflattened photon beam from an Elekta Precise linear accelerator

The characteristics of an Elekta amorphous silicon (a-Si) electronic portal imaging device (EPID) in response to a 6 MV photon beam generated without a flattening filter, an unflattened beam, have been determined. The characteristics were then compared to those for a conventional photon beam generated with a flattening filter in the beam, a flattened beam, in order to determine the suitability of an a-Si EPID for transit dosimetry. The response of the EPID to the unflattened beam increased by 7.3% compared to the flattened beam, and copper buildup of 3 mm reduces the variation in the EPID response over air gaps ranging from 60 to 40 cm to within 2.5%. The scattering properties of the EPID with changing field size for the unflattened beam agree with those measured for a flattened beam to within 2%. Due to the minimal variation in the energy spectrum of the unflattened beam with the distance from the central axis, it was expected and experimentally found that the profile shape of the unflattened beam changes minimally with increasing phantom thickness. For an unflattened beam, EPID measured profiles with and without a phantom in the beam agree to within 2% using confidence limits. The difference between EPID and ionization chamber profiles measured at a depth of 5 cm in water is reduced compared to a flattened beam and remains unchanged with increasing phantom thickness. A difference of 4% was found between EPID profiles and the corresponding profiles measured with an ionization chamber measured in water over a range of phantom thickness. A calibration procedure was developed to convert EPID images to the equivalent absolute dose in water, at the EPID plane. A gamma evaluation was performed comparing the calibrated EPID images to dose measured with an ionization chamber array for rectangular fields and an IMRT segment. The fields were situated on axis and at 5 cm off axis with and without a 25 cm thick phantom in the beam. The gamma evaluation criteria of 3% and 3 mm were met within the field, for all fields examined. This study concludes that a-Si EPIDs are suitable dosimeters for IMRT treatments using unflattened photon beams with the advantage that the characteristics of the unflattened beam result in a reduction in the number of measurements necessary to calibrate an a-Si EPID as a transit dosimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prompt-delayed $\gamma$-ray spectroscopy with AGATA, EXOGAM and VAMOS++

Here, a new experimental setup to measure prompt-delayed γ-ray coincidences from isotopically identified fission fragments, over a wide time range of 100ns-200μ s, is presented. The fission fragments were isotopically identified, on an event-by-event basis, using the VAMOS++ large acceptance spectrometer. The prompt γ rays emitted at the target position and corresponding delayed γ rays emitted at the focal plane of the spectrometer were detected using, respectively, thirty two crystals of the AGATA γ-ray tracking array and seven EXOGAM HPGe Clover detectors. Finally, fission fragments produced in fusion and transfer-induced fission reactions, using a 238 U beam at an energy of 6.2 MeV/u impinging on a 9 Be target, were used to characterize and qualify the performance of the detection system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-mass Star Formation in the Outer Scutum–Centaurus Arm

The Outer Scutum–Centaurus (OSC) spiral arm is the most distant molecular spiral arm in the Milky Way, but until recently little was known about this structure. Discovered by Dame and Thaddeus, the OSC lies ∼15 kpc from the Galactic Center. Due to the Galactic warp, it rises to nearly 4° above the Galactic Plane in the first Galactic quadrant, leaving it unsampled by most Galactic plane surveys. Here we observe H ii region candidates spatially coincident with the OSC using the Very Large Array to image radio continuum emission from 65 targets and the Green Bank Telescope to search for ammonia and water maser emission from 75 targets. This sample, drawn from the Wide-field Infrared Survey Explorer Catalog of Galactic H ii Regions, represents every H ii region candidate near the longitude–latitude (ℓ,b) locus of the OSC. Coupled with their characteristic mid-infrared morphologies, detection of radio continuum emission strongly suggests that a target is a bona fide H ii region. Detections of associated ammonia or water maser emission allow us to derive a kinematic distance and determine if the velocity of the region is consistent with that of the OSC. Nearly 60% of the observed sources were detected in radio continuum, and more than 20% have ammonia or water maser detections. The velocities of these sources mainly place them beyond the Solar orbit. These very distant high-mass stars have stellar spectral types as early as O4. We associate high-mass star formation at 2 new locations with the OSC, increasing the total number of detected H ii regions in the OSC to 12.

79 ASTRONOMY AND ASTROPHYSICS↗

Coupling mechanism of gain-guided integrated semiconductor laser arrays

It is shown that a gain-guided laser array couples via propagating fields rather than the evanescent mode coupling typically responsible for directional coupling in passive (directional couplers) and active (laser array) devices. It is shown that these phase-locked modes exhibit an interference pattern, in the junction plane, which arises from the curvature of the phase fronts of optical fields of the interacting lasers. The experimental results are interpreted with the aid of a simple theoretical model, and the effect of the observed mode pattern on the coupling of gain-guided lasers is discussed.

Kapon, E.↗

Passive Element Shapes Antenna Radiation Pattern

Parasitic waveguide element suppresses ground-reflected multipath radiation. Small section of waveguide placed in front of phased-array antenna operating at 850 MHz modifies radiation field by reducing power density parallel to and below ground plane without significantly affecting primary radiation at angles greater than 20 degrees above horizontal. Acts as parasitic radiator that shifts phase of portion of wavefront by approximately 180 degrees, causing partial cancellation in ground plane, thereby reducing radiation intensity in that direction by about 10 dB. Produces corresponding reduction in multipath radiation scattered from ground. Waveguide technique also used to decouple two nearby antennas.

Bonebright, M. E.↗

Gain enhancement of microstrip antennas with overlaying parasitic directors

An experimental study of gain enhancement in microstrip antennas using identical parasitic patch directors is reported. The results indicate that, with two overlying parasitic directors, the gain of a rectangular microstrip antenna is enhanced from 4.7 dB to 10.6 dB, while the 3 dB beamwidth is reduced from 103 deg to 30 deg for the E-plane and from 70 deg to 35 deg for the H-plane. The three-layer electromagnetically coupled patch antenna exhibits similar antenna characteristics to those of the Yagi array, with over 120 dB gain and with about 1 percent bandwidth.

Lee, R. Q.↗

Electric Field Induced Interfacial Instabilities

The study of the interface in a charge-free, critical and near-critical binary fluid in the presence of an externally applied electric field is presented. At sufficiently large fields, the interface between the two phases of the binary fluid should become unstable and exhibit an undulation with a predefined wavelength on the order of the capillary length. As the critical point is approached, this wavelength is reduced, potentially approaching length-scales such as the correlation length or critical nucleation radius. At this point the critical properties of the system may be affected. In this paper, the flat interface of a marginally polar binary fluid mixture is stressed by a perpendicular alternating electric field and the resulting instability is characterized by the critical electric field E(sub c) and the pattern observed. The character of the surface dynamics at the onset of instability is found to be strongly dependent on the frequency f of the field applied. The plot of E(sub c) vs. f for a fixed temperature shows a sigmoidal shape, whose low and high frequency limits are well described by a power-law relationship, E(sub c) = epsilon(exp zeta) with zeta = 0.35 and zeta = 0.08, respectively. The low-limit exponent compares well with the value zeta = 4 for a system of conducting and non-conducting fluids. On the other hand, the high-limit exponent coincides with what was first predicted by Onuki. The instability manifests itself as the conducting phase penetrates the non-conducting phase. As the frequency increases, the shape of the pattern changes from an array of bifurcating strings to an array of column-like (or rod-like) protrusions, each of which spans the space between the plane interface and one of the electrodes. For an extremely high frequency, the disturbance quickly grows into a parabolic cone pointing toward the upper plate. As a result, the interface itself changes its shape from that of a plane to that of a high sloping pyramid.

Kusner, Robert E.↗

Spitzer Space Telescope: Focal Plane Survey Final Report: IRAC - Appendix B:

This final report summarizes the results and accuracies of the Spitzer Space Telescope focal plane survey. Accuracies achieved are compared to the focal plane survey calibration requirements put forth in the SIRTF IOC-SV Mission Plan [14] and pre-flight predictions made in [2]. The results of this focal plane survey are presently being used to support in-flight precision pointing, precision incremental offsets, IRS peakup array calibration, and ground pointing reconstruction...

kalman filtering↗

NASA Tech Briefs, July 2012

Topics covered include: Instrument Suite for Vertical Characterization of the Ionosphere-Thermosphere System; Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure; Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments; Determining Performance Acceptability of Electrochemical Oxygen Sensors; Versatile Controller for Infrared Lamp and Heater Arrays; High-Speed Scanning Interferometer Using CMOS Image Sensor and FPGA Based on Multifrequency Phase-Tracking Detection; Ultra-Low-Power MEMS Selective Gas Sensors; Compact Receiver Front Ends for Submillimeter-Wave Applications; Dynamically Reconfigurable Systolic Array Accelerator; Blocking Losses With a Photon Counter; Motion-Capture-Enabled Software for Gestural Control of 3D Mod; Orbit Software Suite; CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW); Trajectory Software With Upper Atmosphere Model; ALSSAT Version 6.0; Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms; Demonstration of Minimally Machined Honeycomb Silicon Carbide Mirrors; Polyimide Aerogel Thin Films; Nanoengineered Thermal Materials Based on Carbon Nanotube Array Composites; Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass; Robust Tensioned Kevlar Suspension Design; Focal Plane Alignment Utilizing Optical CMM; Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass; Virtual Ultrasound Guidance for Inexperienced Operators; Beat-to-Beat Blood Pressure Monitor; Non-Contact Conductivity Measurement for Automated Sample Processing Systems; An MSK Radar Waveform; Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures; Method to Remove Particulate Matter from Dusty Gases at Low Pressures; Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile; Measurement Via Optical Near-Nulling and Subaperture Stitching; 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System; Airborne Hyperspectral Imaging System; Heat Shield Employing Cured Thermal Protection Material Blocks Bonded in a Large-Cell Honeycomb Matrix; and Asymmetric Supercapacitor for Long-Duration Power Storage.

Source record↗