Search NASA⌕ Search

SEARCH · Search NASA

Results for “programmable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

Gluon Polarisation in the Nucleon from High Transverse Momentum Hadron Pairs at COMPASS

The main goal of the COMPASS spin physics programme is the measurement of the helicity contribution of the gluons, {delta}G/G, to the nucleon spin. It is determined from the longitudinal spin asymmetry in the scattering of 160 GeV polarised muons off a polarised LiD target. The new analysis and new COMPASS {delta}G/G result obtained from high transverse momentum hadron pairs for Q{sup 2}>1(GeV/c){sup 2} is presented. The weighted method based on a Neural Network approach is discussed. The result of {delta}G/G 0.08{+-}0.10(stat){+-}0.05(syst)disfavors a large positive contribution to the nucleon spin for a gluon momentum fraction around 0.08 and agrees with the previously obtained result from the analysis for the small Q{sup 2} kinematical region (Q{sup 2}<1(GeV/c){sup 2})

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vacuum-compatible pulse selector for free-electron laser

We developed a vacuum-compatible pulse selector for a free-electron laser. A rotating cylinder with eight apertures in a vacuum is driven by a closed-loop stepping motor system through a magnetically coupled rotary feedthrough. A field programmable gate array is used to synchronize the cylinder rotation with a trigger signal of the accelerator at a maximum repetition rate of 60 Hz. We achieved to select specific pulses from a continuous pulse train of the SPring-8 Compact SASE Source.

43 PARTICLE ACCELERATORS↗

Information Theory and Plasma Turbulence

Information theory, applied directly to measured signals, yields new perspectives on, and quantitative knowledge of, the physics of strongly nonlinear and turbulent phenomena in plasmas. It represents a new and productive element of the topical research programmes that use modern techniques to characterise strongly nonlinear signals from plasmas, and that address global plasma behaviour from a complex systems perspective. We here review some pioneering studies of mutual information in solar wind and magnetospheric plasmas, using techniques tested on standard complex systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Status of the ITER IC H and CD System

The ITER Ion Cyclotron Heating and Current Drive system will deliver 20 MW of radio frequency power to the plasma in quasi continuous operation during the different phases of the experimental programme. The system also has to perform conditioning of the tokamak first wall at low power between main plasma discharges. This broad range of requirements imposes a high flexibility and a high availability. The paper highlights the physics and design requirements on the IC system, the main features of its subsystems, the predicted performance, and the current procurement and installation schedule.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experiments on rotamak plasma equilibrium and shape control

A set of magnetic shaping coils and copper rings is installed in cylindrical chamber rotamak to allow for an active equilibrium control in 40 ms plasma discharges. The coils, which are powered by programmable current source, are used to control both the plasma shape and the boundary poloidal magnetic flux. Without the active equilibrium control, the boundary flux drops from its vacuum value of 0.3 mWb to zero after the plasma current is generated. If the coils are activated, the boundary magnetic flux can be sustained within the 0.2-0.3 mWb range, thus keeping the separatrix away from chamber wall during whole period of the shot. The passive copper rings help in eliminating the fast variations of the boundary magnetic flux. The response of rotamak plasma to the active equilibrium control is drastically different in regimes with or without external toroidal field. A model is presented that describes the change in plasma shape, plasma current, and pressure under the effect of active equilibrium coils.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The SuperB Experiment

In these proceedings I briefly introduce the project prior to discussing the physics programme of the SuperB high luminosity e{sup +}e{sup -} collider. By measuring the golden matrix SuperB will be able to elucidate and constrain the nature of physics beyond the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Semi-Empirical Model of X-ray Tube Facility

A semi-empirical model of spectrum of X-ray tube was developed for the radiotherapy facility at the A. I. Burnazyan Federal Medical Biophysical Center for radiobiological experiments. The spectrum calculated by a programme EGSnrc was compared with the spectrum of the model. The results of the spectrum computations showed a good concord with the semi-empirical model. Comparison of the calculations of absorbed doses of the photon radiation in heterogeneous tissue phantoms for photon-capture therapy was done.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

B Physics at the LHC

The LHC is scheduled to start its first physics data taking period later in 2009. Primarily LHCb but also ATLAS and CMS will start a rich B physics programme with the potential of revealing New Physics in the heavy flavour sector. This contribution will cover the prospects for B physics at the LHC with particular emphasis to early measurements. This includes CP violation measurements in B{sub d}{sup 0} and B{sub s}{sup 0} decays, searches for rare decays such as B{sub s}{sup 0}->{mu}{mu}, as well as semileptonic and radiative channels.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Global Event-identifier Module: A distributed digital approach to event-of-interest identification logic for physics experiments

The demands from current data acquisition systems are to acquire data from a large number of detectors (or signals) while providing a high throughput. This can be achieved by having some preprocessing capability in the data acquisition system so that it can identify the events of interest. Precise selection of events with minimal time for identification and preprocessing is an experimental challenge. To address this challenge, we have developed a ''Global Event-identifier Module'' (GEM) on the CAMAC platform, which can flexibly adapt to the experimental requirements and validate an event with minimal time. GEM is a single width CAMAC module capable of operating in a ''distributed'' data acquisition environment where multiple CAMAC crates (each with one GEM module) can be used to collect synchronized data from all the crates. Event-of-interest decision can be made on signals connected to different crates. Inter-GEM communication is via the ubiquitous ethernet (unshielded twisted pair, CAT5) cable. The event of interest is decided within 32 ns (excluding cable delay). Implementation is accomplished using field programmable gate array which enables greater flexibility for algorithm modifications and updates without hardware changes. GEM supports unified, distributed, and multi-strobe data acquisition, enabling higher throughput, with data collection from a large number of signals by selective reads of events of interest as determined by the experimenter while providing timestamped data of each event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modelling Dowel Action of Discrete Reinforcing Bars in Cracked Concrete Structures

Dowel action is one of the component actions for shear force transfer in cracked reinforced concrete. In finite element analysis of concrete structures, the use of discrete representation of reinforcing bars is considered advantageous over the smeared representation due to the relative ease of modelling the bond-slip behaviour. However, there is very limited research on how to simulate the dowel action of discrete reinforcing bars. Herein, a numerical model for dowel action of discrete reinforcing bars crossing cracks in concrete is developed. The model features the derivation of dowel stiffness matrix based on beam-on-elastic-foundation theory and the direct assemblage of dowel stiffness into the concrete element stiffness matrices. The dowel action model is incorporated in a nonlinear finite element programme with secant stiffness formulation. Deep beams tested in the literature are analysed and it is found that the incorporation of dowel action model improves the accuracy of analysis.

42 ENGINEERING↗

Design of microcontroller based system for automation of streak camera

A microcontroller based system has been developed for automation of the S-20 optical streak camera, which is used as a diagnostic tool to measure ultrafast light phenomenon. An 8 bit MCS family microcontroller is employed to generate all control signals for the streak camera. All biasing voltages required for various electrodes of the tubes are generated using dc-to-dc converters. A high voltage ramp signal is generated through a step generator unit followed by an integrator circuit and is applied to the camera's deflecting plates. The slope of the ramp can be changed by varying values of the capacitor and inductor. A programmable digital delay generator has been developed for synchronization of ramp signal with the optical signal. An independent hardwired interlock circuit has been developed for machine safety. A LABVIEW based graphical user interface has been developed which enables the user to program the settings of the camera and capture the image. The image is displayed with intensity profiles along horizontal and vertical axes. The streak camera was calibrated using nanosecond and femtosecond lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Clinical Trials Program at the ESRF Biomedical Beamline ID17: Status and Remaining Steps

For several years the ID17 Biomedical beamline at the ESRF has developed synchrotron radiation therapy preclinical programmes to treat aggressive brain tumours. Two techniques have been developed at the ESRF:a) The Microbeam Radiation Therapy (MRT) using spatially fractionated 'white beam' (energies 50-300 keV) irradiation (beam widths 25-100 {mu}m, spacing between beams 200-400 {mu}m ) with extremely high dose rates (up to about 20 kGy/s) and depositing very high doses (300-1000 Gy) in the targeted tissue.b) The Stereotactic Synchrotron Radiation Therapy (SSRT) using spatially homogeneous monochromatic beam with the energy closely above that of the K-edge of a contrast- or chemotherapeutical agent (iodine, gadolinium, platinum) loaded into the tumour volume for obtaining a dose-enhancement. In 2005 an International review panel of oncology experts has recommended to move to clinical trials on humans in SSRT and on large animals in MRT. The works required for this program were launched in autumn 2007 with constructing a new, dedicated experimental hutch for MRT and a major upgrade of the existing sample-positioning station to a patient-positioning station for SSRT. In parallel, safety systems are developed and progressively implemented and a patient treatment-planning system developed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fabrication and Characterization of Elliptically-Curved, Laterally-Graded Multilayers for Focusing X-ray Polychromator Applications

We have developed a novel X-ray multilayer working as a focusing polychromator. A multilayer mirror enables independent designs of the focal length and the spectral dispersion, and much higher throughput than the curved crystal. Our ion beam sputtering deposition apparatus has a speed programmable shuttering system for control of the lateral thickness gradient. A SiC/C and three V/C multilayers were deposited on each 150 mm long Si wafers. Period thicknesses are tuned to the designed energy of 5-12 keV, 12-19 keV, 19-26 keV and 26-33 keV, respectively. Four multilayers were clamped to form a 600 mm long 5-33 keV range elliptic mirror on a shaped Cu base plate. The focal length is 700 mm, which is large enough for setups around the sample position. The energy calibration was performed at BL-15C of the Photon Factory based on absorption edges of metal foils, which was in good agreement with the period thickness measured by a laboratory X-ray diffractometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The New ESRF Multilayer Facility: Progress and Perspectives

In view of the increasing need for high quality multilayer based x-ray optics the ESRF decided to upgrade its multilayer facility. During the last years a new deposition system was designed, installed, and commissioned. Since 2008 the new laboratory is operational and has produced its first optical elements for ESRF beamlines. The deposition system is based on magnetron sputtering and can cover optical surfaces up to 1000x150 mm{sup 2} with uniform or graded coatings. Four cathodes allow the use of conducting, insulating, and ferromagnetic target materials. This work will provide an overview on the machine conception and its overall performance, including a comparison with the formerly used system. It will be complemented by first fabrication results and perspectives for future projects in the framework of the ESRF Upgrade Programme.

43 PARTICLE ACCELERATORS↗

Recent developments of the JET far-infrared interferometer-polarimeter diagnostic

The far-infrared diagnostic provides essential internal measurements of the plasma density and magnetic field topology (q-profile via Faraday rotation angle) in real-time. The diagnostic capabilities have recently been extended in a number of key areas. Fast interferometer data, with 10 {mu}s time resolution, and a new MATLAB code have allowed improved analysis of the evolution of density profiles during fast events such as vertical plasma displacements, edge localized mode, pellet fuelling, and disruptions. Using the polarimeter measurements in real-time, a new calibration procedure has been developed based on a propagation code using the Mueller matrix formalism. A further major upgrade of the system is presently underway: adding a second color laser to the vertical channels and implementing a new phase counter based on analog zero crossing and field-programmable gate array boards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchronization of Thomson scattering measurements on MAST using an FPGA based ''Smart'' trigger unit

The MAST Thomson scattering diagnostic has recently been upgraded to make electron density and temperature measurements at 130 points across the 1.5 m diameter of the plasma. The new system is able to take 240 measurements per second using eight Nd:YAG lasers, each running at 30 Hz. The exact firing time of these lasers is adjusted with 100 ns precision using a field programmable gate array based trigger unit. Trigger pulses are produced to fire the lamps of all lasers and the Q switches with the appropriate delay depending on the warm-up status. The lasers may be fired in rapid bursts so as to achieve a high temporal resolution over eight points separated down to the microsecond level. This trigger unit receives optical trigger events and signals from external sources, allowing the trigger sequences to be resynchronized to the start of the plasma pulse and further events during the shot such as the entry of a fuelling pellet or randomly occurring plasma events. This resynchronization of the laser firing sequence allows accurate and reproducible measurements of fast plasma phenomena.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lattice investigation of nucleon structure at light quark masses

Lattice simulations of hadronic structure are now reaching a level where they are able to not only complement, but also provide guidance to current and forthcoming experimental programmes at, e.g. Jefferson Lab, COMPASS/CERN and FAIR/GSI. By considering new simulations at low quark masses and on large volumes, we review the recent progress that has been made in this exciting area by the QCDSF/UKQCD collaboration. In particular, results obtained close to the physical point for several quantities, including electromagnetic form factors and moments of ordinary parton distribution functions, show some indication of approaching their phenomenological values.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis and improvements of fringe jump corrections by electronics on the JET tokamak far infrared interferometer

For the Tore Supra interferometer phase measurements, an electronics had been developed electronics using field programmable gate array processors. The embedded algorithm can correct the fringe jumps. For comparison, the electronics ran at JET during the 2009 campaign. The first analysis concluded that the electronics was not correcting all the fringe jumps. An analysis of the failures led to improvements in the algorithm, which was tested during the rest of the campaign. In this article, we evaluate the increases in the performance. From the analysis of the remaining faults, further improvements are discussed for designing future boards that are foreseen for JET using the second wavelength and the Cotton-Mouton effect information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗