Search NASA⌕ Search

SEARCH · Search NASA

Results for “replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,351 records · Page 75

HFE 7100 Compatibility with Orbiter Materials

Chlorofluorocarbon (CFC) 113 is currently specified as the precision cleaning and verification fluid for orbiter materials. The production ban of CFC 113, an ozone-depleting chlorofluorocarbon, has resulted in a search for a replacement cleaning fluid. Recently, the 3M Company announced the manufacture of a new class of cleaning fluids, hydrofluoroethers. The first in this class of cleaning fluids is HFE 7100, perfluorobutyl methyl ether. This cleaning fluid has been submitted for consideration as a replacement for CFC 113. One of the requirements of the certification process for a replacement cleaning fluid is compatibility testing. The Johnson Space Center (JSC) Materials and Manufacturing Division has requested that NASA JSC White Sands Test Facility perform the compatibility testing with HFE 7100 on selected orbiter materials. Most of the materials selected for testing were previously evaluated for compatibility with CFC 113. Some of the materials are new additions to the orbiter or were not available when the compatibility testing was performed with CFC 113. These materials were evaluated with both cleaning fluids and the results were used to compare the response to the cleaning fluid and to satisfy the certification process requirements. It was found that HFE 7100 is generally compatible with the materials tested.

Chlorofluorocarbon↗

Improving the Fire Weather Index System for Peatlands Using Peat-Specific Hydrological Input Data

The Canadian Fire Weather Index (FWI) system, even though originally developed and calibrated for an upland Jack pine forest, is used globally to estimate fire danger for any fire environment. However, for some environments, such as peatlands, the applicability of the FWI in its current form, is often questioned. In this study, we replaced the original moisture codes of the FWI with hydrological estimates resulting from the assimilation of satellite-based L-band passive microwave observations into a peatland-specific land surface model. In a conservative approach that maintains the integrity of the original FWI structure, the distributions of the hydrological estimates were first matched to those of the corresponding original moisture codes before replacement. The resulting adapted FWI, hereafter called FWIpeat, was evaluated using satellite-based information on fire presence over boreal peatlands from 2010 through 2018. Adapting the FWI with model- and satellite-based hydrological information was found to be beneficial in estimating fire danger, especially when replacing the deeper moisture codes of the FWI. For late-season fires, further adaptations of the fine fuel moisture code show even more improvement due to the fact that late-season fires are more hydrologically driven. The proposed FWIpeat should enable improved monitoring of fire risk in boreal peatlands.

Canadian Fire Weather Index↗

Lessons Learned from Astrobee Operations on the International Space Station

Since its launch in 2019, NASA has been operating three Astrobee free-flying robots providing an autonomous and adaptable research platform aboard the International Space Station (ISS). These robots have not only facilitated a myriad of national and international research endeavors in microgravity but have also served as a STEM outreach platform for student competitions aboard the ISS. Amidst its extensive operational tenure, spanning over five years and exceeding 1200 hours of cumulative free-flyer operation as of April 2024, the Astrobee robots have encountered software and hardware anomalies. Despite its inherent design for on-orbit repair or replacement, certain anomalies have proven to be complex, necessitating remote resolution via software and firmware updates or, in extreme cases, hardware replacements or the return of faulty units to NASA's ground facilities for repair. Such challenges underscore the delicate balance between the autonomous functionality of Astrobee and the occasional need for human intervention to maintain optimal performance. One recurring point of failure identified during Astrobee's operational lifespan has been the SD card, a critical component utilized by the different Astrobee processors and the Dock Station. The occurrence of SD card anomalies, both on orbit and within ground units, has provided invaluable insights into the improvement of Astrobee's systems and mitigation to future faults. This presentation will focus on four key areas: 1. Overview of Faults and Anomalies: A comprehensive examination of the diverse array of faults and anomalies encountered by Astrobee and its associated systems both in orbit and on the ground. From software glitches to hardware malfunctions, this section provides insights into the challenges faced during Astrobee's operational tenure. 2. Resolution Processes and Procedures: An in-depth discussion of the methodologies and procedures implemented to resolve the encountered anomalies. This includes remote troubleshooting, software patches, firmware updates, and, when necessary, the logistics involved in hardware replacements or down-massing for repair. 3. Implementation of Software Updates and Hardware Upgrades: A detailed exploration of the strategies employed to mitigate the risk of recurring anomalies through the implementation of software updates and hardware upgrades. This section highlights the iterative nature of Astrobee's development, emphasizing the continuous pursuit of robustness and reliability. 4. Lessons Learned and Future Directions: Reflecting on the insights gained from addressing anomalies, this section examines the lessons learned and outlines future directions for enhancing Astrobee's robustness and resilience. It underscores the iterative nature of space exploration and the importance of adaptability and continuous improvement in the pursuit of scientific discovery. Through a nuanced examination of Astrobee's operational challenges and the strategies employed to overcome them, this presentation sheds light on the complexities of operating autonomous robotic systems in the ISS environment. It underscores NASA's commitment to pushing the boundaries of exploration and innovation while navigating the inherent challenges of space exploration.

Astrobee↗

Lessons Learned from Astrobee Operations on the International Space Station

Since its launch in 2019, NASA has been operating three Astrobee free-flying robots providing an autonomous and adaptable research platform aboard the International Space Station (ISS). These robots have not only facilitated a myriad of national and international research endeavors in microgravity but have also served as a STEM outreach platform for student competitions aboard the ISS. Amidst its extensive operational tenure, spanning over five years and exceeding 1200 hours of cumulative free-flyer operation as of April 2024, the Astrobee robots have encountered software and hardware anomalies. Despite its inherent design for on-orbit repair or replacement, certain anomalies have proven to be complex, necessitating remote resolution via software and firmware updates or, in extreme cases, hardware replacements or the return of faulty units to NASA's ground facilities for repair. Such challenges underscore the delicate balance between the autonomous functionality of Astrobee and the occasional need for human intervention to maintain optimal performance. One recurring point of failure identified during Astrobee's operational lifespan has been the SD card, a critical component utilized by the different Astrobee processors and the Dock Station. The occurrence of SD card anomalies, both on orbit and within ground units, has provided invaluable insights into the improvement of Astrobee's systems and mitigation to future faults. This presentation will focus on four key areas: 1. Overview of Faults and Anomalies: A comprehensive examination of the diverse array of faults and anomalies encountered by Astrobee and its associated systems both in orbit and on the ground. From software glitches to hardware malfunctions, this section provides insights into the challenges faced during Astrobee's operational tenure. 2. Resolution Processes and Procedures: An in-depth discussion of the methodologies and procedures implemented to resolve the encountered anomalies. This includes remote troubleshooting, software patches, firmware updates, and, when necessary, the logistics involved in hardware replacements or down-massing for repair. 3. Implementation of Software Updates and Hardware Upgrades: A detailed exploration of the strategies employed to mitigate the risk of recurring anomalies through the implementation of software updates and hardware upgrades. This section highlights the iterative nature of Astrobee's development, emphasizing the continuous pursuit of robustness and reliability. 4. Lessons Learned and Future Directions: Reflecting on the insights gained from addressing anomalies, this section examines the lessons learned and outlines future directions for enhancing Astrobee's robustness and resilience. It underscores the iterative nature of space exploration and the importance of adaptability and continuous improvement in the pursuit of scientific discovery. Through a nuanced examination of Astrobee's operational challenges and the strategies employed to overcome them, this presentation sheds light on the complexities of operating autonomous robotic systems in the ISS environment. It underscores NASA's commitment to pushing the boundaries of exploration and innovation while navigating the inherent challenges of space exploration.

Astrobee↗

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

ECLSS↗

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

Toilet↗

The crystal structure of TrxA(CACA): Insights into the formation of a [2Fe-2S] iron-sulfur cluster in an Escherichia coli thioredoxin mutant

Escherichia coli thioredoxin is a small monomeric protein that reduces disulfide bonds in cytoplasmic proteins. Two cysteine residues present in a conserved CGPC motif are essential for this activity. Recently, we identified mutations of this motif that changed thioredoxin into a homodimer bridged by a [2Fe-2S] iron-sulfur cluster. When exported to the periplasm, these thioredoxin mutants could restore disulfide bond formation in strains lacking the entire periplasmic oxidative pathway. Essential for the assembly of the iron-sulfur was an additional cysteine that replaced the proline at position three of the CGPC motif. We solved the crystalline structure at 2.3 {angstrom} for one of these variants, TrxA(CACA). The mutant protein crystallized as a dimer in which the iron-sulfur cluster is replaced by two intermolecular disulfide bonds. The catalytic site, which forms the dimer interface, crystallized in two different conformations. In one of them, the replacement of the CGPC motif by CACA has a dramatic effect on the structure and causes the unraveling of an extended {alpha}-helix. In both conformations, the second cysteine residue of the CACA motif is surface-exposed, which contrasts with wildtype thioredoxin where the second cysteine of the CXXC motif is buried. This exposure of a pair of vicinal cysteine residues apparently allows thioredoxin to acquire an iron-sulfur cofactor at its active site, and thus a new activity and mechanism of action.

36 MATERIALS SCIENCE↗

Performing process migration with allreduce operations

Compute nodes perform allreduce operations that swap processes at nodes. A first allreduce operation generates a first result and uses a first process from a first compute node, a second process from a second compute node, and zeros from other compute nodes. The first compute node replaces the first process with the first result. A second allreduce operation generates a second result and uses the first result from the first compute node, the second process from the second compute node, and zeros from others. The second compute node replaces the second process with the second result, which is the first process. A third allreduce operation generates a third result and uses the first result from first compute node, the second result from the second compute node, and zeros from others. The first compute node replaces the first result with the third result, which is the second process.

Archer, Charles Jens↗

LANSCE Drift Tube Linac Water Control System Refurbishment

There are several refurbishment projects underway at the Los Alamos National Laboratory LANSCE linear accelerator. Systems involved are: RF, water cooling, networks, diagnostics, timing, controls, etc. The Drift Tube Linac (DTL) portion of the accelerator consists of four DTL tanks, each with three independent water control systems. The systems are about 40 years old, use outdated and non-replaceable equipment and NIM bin control modules, are beyond their design life and provide unstable temperature control. Insufficient instrumentation and documentation further complicate efforts at maintaining system performance. Detailed design of the replacement cooling systems is currently in progress. Previous design experience on the SNS accelerator water cooling systems will be leveraged, see the SNS DTL FDR. Plans call for replacement of water piping, manifolds, pumps, valves, mix tanks, instrumentation (flow, pressure and temperature) and control system hardware and software. This presentation will focus on the control system design with specific attention on planned use of the National Instruments Compact RIO platform with the Experimental Physics and Industrial Control system (EPICS) software toolkit.

Accelerator Design, Technology, and Operations↗

Efficient algorithm for generating spectra using line-by-lne methods

A method is presented for efficient generation of spectra using line-by-line approaches. The only approximation is replacing the line shape function with an interpolation procedure, which makes the method independent of the line profile functional form. The resulting computational savings for large number of lines is proportional to the number of frequency points in the spectral range. Therefore, for large-scale problems the method can provide speedups of two orders of magnitude or more. A method was presented to generate line-by-line spectra efficiently. The first step was to replace the explicit calculation of the profile by the Newton divided-differences interpolating polynomial. The second step is to accumulate the lines effectively reducing their number to the number of frequency points. The final step is recognizing the resulting expression as a convolution and amenable to FFT methods. The reduction in computational effort for a configuration-to-configuration transition array with large number of lines is proportional to the number of frequency points. The method involves no approximations except for replacing the explicit profile evaluation by interpolation. Specifically, the line accumulation and convolution are exact given the interpolation procedure. Furthermore, the interpolation makes the method independent of the line profile functional form contrary to other schemes using FFT methods to generate line-by-line spectra but relying on the analytic form of the profile Fourier transform. Finally, the method relies on a uniform frequency mesh. For non-uniform frequency meshes, however, the method can be applied by using a suitable temporary uniform mesh and the results interpolated onto the final mesh with little additional cost.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Productivity Techniques and Quality Aspects in the Criticality Safety Evaluation of Y-12 Type-B Fissile Material Packages

The inventory of certified Type-B fissile material packages consists of ten performance-based packages for offsite transportation purposes, serving transportation programs at the Y-12 National Security Complex. The containment vessels range from 5 to 19 in. in diameter and from 17 to 58 in. in height. The drum assembly external to the containment vessel ranges from 18 to 34 in. in diameter and from 26 to 71 in. in height. The weight of the packaging (drum assembly and containment vessel) ranges from 239 to 1550 lb. The older DT-nn series of Cellotex-based packages are being phased-out and replaced by a new generation of Kaolite-based ('Y-12 patented insulation') packages capable of withstanding the dynamic crush test 10 CFR 71.73(c)(2). Three replacement packages are in various stages of development; two are in use. The U.S. Department of Transportation (DOT) 6M specification package, which does not conform to the U.S. Nuclear Regulatory Commission requirements for Type-B packages, is no longer authorized for service on public roads. The ES-3100 shipping package is an example of a Kaolite-based Type-B fissile material package developed as a replacement package for the DOT 6M. With expanded utility, the ES-3100 is designed and licensed for transporting highly enriched uranium and plutonium materials on public roads. The ES-3100 provides added capability for air transport of up to 7-kg quantities of uranium material. This paper presents the productivity techniques and quality aspects in the criticality safety evaluation of Y-12 packages using the ES-3100 as an example.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Secure Video Surveillance System (SVSS) for unannounced safeguards inspections.

The Secure Video Surveillance System (SVSS) is a collaborative effort between the U.S. Department of Energy (DOE), Sandia National Laboratories (SNL), and the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC). The joint project addresses specific requirements of redundant surveillance systems installed in two South American nuclear facilities as a tool to support unannounced inspections conducted by ABACC and the International Atomic Energy Agency (IAEA). The surveillance covers the critical time (as much as a few hours) between the notification of an inspection and the access of inspectors to the location in facility where surveillance equipment is installed. ABACC and the IAEA currently use the EURATOM Multiple Optical Surveillance System (EMOSS). This outdated system is no longer available or supported by the manufacturer. The current EMOSS system has met the project objective; however, the lack of available replacement parts and system support has made this system unsustainable and has increased the risk of an inoperable system. A new system that utilizes current technology and is maintainable is required to replace the aging EMOSS system. ABACC intends to replace one of the existing ABACC EMOSS systems by the Secure Video Surveillance System. SVSS utilizes commercial off-the shelf (COTS) technologies for all individual components. Sandia National Laboratories supported the system design for SVSS to meet Safeguards requirements, i.e. tamper indication, data authentication, etc. The SVSS consists of two video surveillance cameras linked securely to a data collection unit. The collection unit is capable of retaining historical surveillance data for at least three hours with picture intervals as short as 1sec. Images in .jpg format are available to inspectors using various software review tools. SNL has delivered two SVSS systems for test and evaluation at the ABACC Safeguards Laboratory. An additional 'proto-type' system remains at SNL for software and hardware testing. This paper will describe the capabilities of the new surveillance system, application and requirements, and the design approach.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Upgrade fo the CMS Hadron Outer Calorimeter with SIPMs

The CMS Hadron Outer Calorimeter (HO) is undergoing an upgrade to replace the existing photodetectors (HPDs) with SIPMs. The chosen device is the Hamamatsu 3 x 3mm 50 {mu}m pitch MPPC. The system has been developed to be a 'drop-in' replacement of the HPDs. A complete control system of bias voltage generation, leakage current monitoring, temperature monitoring, and temperature control using solid state Peltier coolers has been developed and tested. 108 channels of the system have been installed into CMS and operated for more than 2 years. The complete system of about 2200 channels is in production and will be installed in the next LHC long shutdown scheduled for 2013. The CMS central calorimeter consists of a detector inside the solenoidal magnet, HB, and a component outside the magnet, the Outer Hadron Calorimeter, HO [1]. The HO is installed inside the magnet flux return yoke and provides for typically 3{lambda} of additional absorber to the calorimetric measurement. The outer calorimeter is composed of one or more layers of scintillator with wavelength shifting fiber readout into photodetectors. Figure 1 (a) shows the schematic layout of the calorimeters in CMS and shows the location of the HO scintillator layers. The front end electronics are placed inside the CMS detector, close to the scintillators. Figure 1(b) shows a photograph of the scintillators. Note the four wavelength shifting fibers per tile. The tile size creates a projective tower with the HB. Currently the photodetector used is the HPD but for performance and operational reasons it is desired to upgrade these with SIPMs. The CMS HCAL group has developed a drop-in replacement for the HPD using SIPMs. SIPMs are very suitable for this application because of several factors: The radiation levels are modest with a lifetime expected fluence of less than 5*10{sup 11} neutrons (E > 100 KeV) per cm{sup 2}. The energy flux into HO is small, the rate of larger energy depositions is low, and the required dynamic range is modest. The HO is in the return magnetic field of up to 2KG and the photodetector needs to operate in that environment. Finally, the available physical volume for the photodetectors is small.

43 PARTICLE ACCELERATORS↗

US Veteran Gets a Facelift

Idaho National Laboratory's Advanced Test Reactor (ATR) has received replacement instrumentation and control systems - the process distributed control system (DCS) and the console display system (CDS), which included a replacement annunciator subsystem. The new systems offer the latest software and technology advancements, ensuring the availability of the reactor for future energy research. ATR, a pressurized, light water moderated 250 MW materials test reactor, became operational in 1965. In the early 1990s, after nearly thirty years of analogue/pneumatic controls, the laboratory upgraded ATR to digital-based instrumentation and control systems. By 2007, the equipment and technology used in these digital systems were reaching the end of their lifecycle. The systems component failure rates were on a rise, while vendor support and parts availability were declining. With current projections and plans for operating ATR into 2040, modernization of the reactor's infrastructure is necessary to maintain reliability and efficiency. As a result, the Idaho National Laboratory and the U.S. Department of Energy (DOE) invested more than $13 million in a four-year project to replace ATR's instrumentation and control systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ALTERNATIVES TO HELIUM-3 FOR NEUTRON MULTIPLICITY DETECTORS

Collaboration between the Pacific Northwest National Laboratory (PNNL) and the Los Alamos National Laboratory (LANL) is underway to evaluate neutron detection technologies that might replace the high-pressure helium (3He) tubes currently used in neutron multiplicity counter for safeguards applications. The current stockpile of 3He is diminishing and alternatives are needed for a variety of neutron detection applications including multiplicity counters. The first phase of this investigation uses a series of Monte Carlo calculations to simulate the performance of an existing neutron multiplicity counter configuration by replacing the 3He tubes in a model for that counter with candidate alternative technologies. These alternative technologies are initially placed in approximately the same configuration as the 3He tubes to establish a reference level of performance against the 3He-based system. After these reference-level results are established, the configurations of the alternative models will be further modified for performance optimization. The 3He model for these simulations is the one used by LANL to develop and benchmark the Epithermal Neutron Multiplicity Counter (ENMC) detector, as documented by H.O. Menlove, et al. in the 2004 LANL report LA-14088. The alternative technologies being evaluated are the boron-tri-fluoride-filled proportional tubes, boron-lined tubes, and lithium coated materials previously tested as possible replacements in portal monitor screening applications, as documented by R.T. Kouzes, et al. in the 2010 PNNL report PNNL-72544 and NIM A 623 (2010) 1035–1045. The models and methods used for these comparative calculations will be described and preliminary results shown

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

25 Years Of Environmental Remediation In The General Separations Area Of The Savannah River Site: Lessons Learned About What Worked And What Did Not Work In Soil And Groundwater Cleanup

The Savannah River Site (SRS) is owned and administered by the US Department of Energy (DOE). SRS covers an area of approximately 900 square kilometers. The General Separation Area (GSA) is located roughly in the center of the SRS and includes: radioactive material chemical separations facilities, radioactive waste tank farms, a variety of radioactive seepage basins, and the radioactive waste burial grounds. Radioactive wastes were disposed in the GSA from the mid-1950s through the mid-1990s. Radioactive operations at the F Canyon began in 1954; radioactive operations at H Canyon began in 1955. Waste water disposition to the F and H Seepage Basins began soon after operations started in the canyons. The Old Radioactive Waste Burial Ground (ORWBG) began operations in 1952 to manage solid waste that could be radioactive from all the site operations, and ceased receiving waste in 1972. The Mixed Waste Management Facility (MWMF) and Low Level Radioactive Waste Disposal Facility (LLRWDF) received radioactive solid waste from 1969 until 1995. Environmental legislation enacted in the 1970s, 1980s, and 1990s led to changes in waste management and environmental cleanup practices at SRS. The US Congress passed the Clean Air Act in 1970, and the Clean Water Act in 1972; the Resource Conservation and Recovery Act (RCRA) was enacted in 1976; the Comprehensive Environmental Response Compensation, and Liability Act (CERCLA) was enacted by Congress in 1980; the Federal Facilities Compliance Act (FFCA) was signed into law in 1992. Environmental remediation at the SRS essentially began with a 1987 Settlement Agreement between the SRS and the State of South Carolina (under the South Carolina Department of Health and Environmental Control - SCDHEC), which recognized linkage between many SRS waste management facilities and RCRA. The SRS manages several of the larger groundwater remedial activities under RCRA for facilities recognized early on as environmental problems. All subsequent environmental remediation projects tend to be managed under tri-party agreement (DOE, Environmental Protection Agency, and SCDHEC) through the Federal Facilities Agreement. During 25 years of environmental remediation SRS has stabilized and capped seepage basins, and consolidated and capped waste units and burial grounds in the GSA. Groundwater activities include: pump and treat systems in the groundwater, installation of deep subsurface barrier systems to manage groundwater flow, in situ chemical treatments in the groundwater, and captured contaminated groundwater discharges at the surface for management in a forest irrigation system. Over the last 25 years concentrations of contaminants in the aquifers beneath the GSA and in surface water streams in the GSA have dropped significantly. Closure of 65 waste sites and 4 RCRA facilities has been successfully accomplished. Wastes have been successfully isolated in place beneath a variety of caps and cover systems. Environmental clean-up has progressed to the stage where most of the work involves monitoring, optimization, and maintenance of existing remedial systems. Many lessons have been learned in the process. Geotextile covers outperform low permeability clay caps, especially with respect to the amount of repairs required to upkeep the drainage layers as the caps age. Passive, enhanced natural processes to address groundwater contamination are much more cost effective than pump and treat systems. SRS operated two very large pump and treat systems at the F and H Seepage Basins to attempt to limit the release of tritium to Fourmile Branch, a tributary of the Savannah River. The systems were designed to extract contaminated acidic groundwater, remove all contamination except tritium (not possible to remove the tritium from the water), and inject the tritiated groundwater up-gradient of the source area and the plume. The concept was to increase the travel time of the injected water for radioactive decay of the tritium. The two systems were found to be non-effective and potentially mobilizing more contamination. SRS invested approximately $50 million in construction and approximately $100 million in 6 years of operation. The H Seepage Basin pump and treat system was replaced by a series of subsurface barriers that alters the groundwater velocity; the F Seepage Basin pump and treat system was replaced by subsurface barriers forming a funnel and gate augmented by chemical treatment within the gates. These replacement systems are mostly passive and cost approximately $13 million to construct, and have reduced the tritium flux to Fourmile Branch, in these plumes, by over 70%. SRS manages non-acidic tritiated groundwater releases to Fourmile Branch from the southwest plume of the MWMF with a forest irrigation system. Tritiated water is captured with a sheetpile dam below the springs that caused releases to Fourmile Branch. Water from the irrigation pond is pumped to a filter plant prior to irrigation of approximately 26 hectares of mixed forest and developing pine plantation. SRS has almost achieved a 70% reduction in tritium flux to the Branch from this plume. The system cost approximately $5 million to construct with operation cost of approximately $500K per year. In conclusion, many lessons have been learned in 25 years of relatively aggressive remedial activities in the GSA. Geotextile covers outperform low permeability clay caps, especially with respect to the amount of repairs required to upkeep the drainage layers as the caps age. Passive, enhanced natural processes to address groundwater contamination are much more cost effective than pump and treat systems. In water management situations with non-accumulative contaminants (tritium, VOCs, etc.) irrigation in a forest setting can be very effective.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interior and Exterior Low-E Storm Window Installation

Until recently, energy-efficient window retrofit options have largely been limited to repair or replacement; leaving the homeowner to decide between affordability and deeper energy savings. A new and improved low-e storm window boasts a combination of curb appeal and energy efficiency, all for a fraction of the cost of window replacement. A recent whole-home experiment performed by PNNL suggests that attaching low-e storm windows can result in as much energy savings replacing the windows.

99 GENERAL AND MISCELLANEOUS↗

Omics Tools

The Omics Tools package provides several small trivial tools for work in genomics. This single portable package, the “omics.jar” file, is a toolbox that works in any Java-based environment, including PCs, Macs, and supercomputers. The number of tools is expected to grow. One tool (called cmsearch.hadoop or cmsearch.local), calls the external cmsearch program to predict non-coding RNA in a genome. The cmsearch program is part of the third-party Infernal package. Omics Tools does not contain Infernal. Infernal may be installed separately. The cmsearch.hadoop subtool requires Apache Hadoop and runs on a supercomputer, though cmsearch.local does not and runs on a server. Omics Tools does not contain Hadoop. Hadoop mat be installed separartely The other tools (cmgbk, cmgff, fastats, pal, randgrp, randgrpr, randsub) do not interface with third-party tools. Omics Tools is written in Java and Scala programming languages. Invoking the “help” command shows currently available tools, as shown below: schaumbe@gpint06:~/proj/omics$ java -jar omics.jar help Known commands are: cmgbk : compare cmsearch and GenBank Infernal hits cmgff : compare hits among two GFF (version 3) files cmsearch.hadoop : find Infernal hits in a genome, on your supercomputer cmsearch.local : find Infernal hits in a genome, on your workstation fastats : FASTA stats, e.g. # bases, GC content pal : stem-loop motif detection by palindromic sequence search (code stub) randgrp : random subsample without replacement, of groups randgrpr : random subsample with replacement, of groups (fast) randsub : random subsample without replacement, of file lines For more help regarding a particular command, use: java -jar omics.jar command help Usage: java -jar omics.jar command args

Schaumberg, Andrew↗